Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.5 LAccepted-AOC FRIENDS COLONY STREET A DHANGU ROAD PATHANKOT 145001 PB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L1 | Accepted-AOC Reasonable | |
| 2 | L2₹17.4 L+₹98,842 (6.01%)Rejected-Finance 99 MODEL TOWN PATHANKOT 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L2 | Rejected-Finance Being Other than L1 | |
| 3 | L3₹17.6 L+₹1.2 L (7.08%)Rejected-Finance | L3 | Rejected-Finance Being Other than L1 | |
| 4 | L4₹17.7 L+₹1.3 L (7.61%)Rejected-Finance SHIVAJI NAGAR GALI NO 1 DHANGU ROAD MODEL TOWN PATHANKOT 145001 PB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L4 | Rejected-Finance Being Other than L1 | |
| 5 | L5₹18.5 L+₹2.0 L (12.2%)Rejected-Finance I 910 JAHANGIR PURI NEAR BY ANAND MAYA HOSPITAL NORTH WEST DELHI DELHI 110033 UDYAM DL 06 0040830 | NORTH DELHI | DELHI | 110033 | L5 | Rejected-Finance Being Other than L1 |
Tender Value
₹32.5 L
EMD Value
₹65,000
Closing Date
25 Jun 2020, 6:00 pmClosed
GE (AF) PATHANKOT
GE (AF) PATHANKOT-145001
REPAIR/ REPLACEMENT AND MAINT OF LT UG CABLES, LT OH LINES, BUS BAR AND DG SET AT TECHNICAL AREA AT AFS PATHANKOT
2020_MES_329934_2
GE/ PAF-58/ 2019-20
Open Tender
Support/Maintenance Service
Item Rate
270 days
GE (AF) PATHANKOT
As per NIT
8 documents required · 8 mandatory
₹500
GE (AF) PATHANKOT
₹65,000
Yes
27 Aug 2020
6 Jun 2020
27 Jun 2020
6 Jun 2020
25 Jun 2020
19 Jun 2020
Amount
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m deep and getting out in any type of soil for laying of cable complete all as specified and directed by Engineer-in-charge.
All as per srl item No 1 above but exc 1.5 m in depth and not exc 3.00 mtr deep complete all as specified and directed by Engineer-in-charge.
Returning filling in (soil) including spreading levelling, watering and well ramming in layers not exc 25cm thickcomplete all as specified and directed by Engineer-in-charge.
Removal of excavated soil to a distance n.exc 50 m and depositing where directed at a level not exc 1.5 mtr above the ground level/starting point compalete all as specified and directed.
Sand cushioning to the under ground electric cable complete all as specified considering 19.75 of SSR part -I complete all as specified and directed by Engineer -in-charge.
Sub Class 'B' brick covering protection to the eletric cable laid dry flat transversally along the length of cable on sand cushioning with width equal to length of brick complete all as specified and directed by Engineer-in-charge.
Reuse old Sub Class 'B' brick covering protection to the eletric cable laid dry flat transversally along the length of cable on sand cushioning with width equal to length of brick complete all as specified and directed by Engineer-in-charge. Note : Excavatgion earth work protection pipe brick protection and sand cushioning etc shall be measured and paid for separately.
Relaying only LT cable or passing through pipe 1100 volts grade heavey duty cable with PVC insulated multistand alumn conductor of size 6 to 185 Sqmm 2/3.5 core,armoured with galvanized steel strip or wire complete all as specified and directed by Engineer-in-charge.
Supply laying and testing cable XLPE insulated screended PVC bedded , galvanised steel strip armoured, electric power cables (heavy cable ) with stranded aluminium conductor , 1100 Volts grade of size 3.5 core 120Sqmm complete all as specified and directed by Engineer-in-charge.
Supply laying and testing cable XLPE insulated screended PVC bedded , galvanised steel strip armoured, electric power cables (heavy cable ) with stranded aluminium conductor , 1100 Volts grade of size 3.5 core 95 Sqmm complete all as specified and directed by Engineer-in-charge.
Supply laying and testing cable XLPE insulated screended PVC bedded , galvanised steel strip armoured, electric power cables (heavy cable ) with stranded aluminium conductor , 1100 Volts grade of size 3.5 core 50 Sqmm complete all as specified and directed by Engineer-in-charge.
Supply laying and testing cable XLPE insulated screended PVC bedded , galvanised steel strip armoured, electric power cables (heavy cable ) with stranded aluminium conductor , 1100 Volts grade of size 3.5 core 35 Sqmm complete all as specified and directed by Engineer-in-charge.
Supply laying and testing cable XLPE insulated screended PVC bedded , galvanised steel strip armoured, electric power cables (heavy cable ) with stranded aluminium conductor , 1100 Volts grade of size 2 core 25 Sqmm complete all as specified and directed by Engineer-in-charge.
Supply laying and testing cable XLPE insulated screended PVC bedded , galvanised steel strip armoured, electric power cables (heavy cable ) with stranded aluminium conductor , 1100 Volts grade of size 2 core 16 Sqmm complete all as specified and directed by Engineer-in-charge.
Supply laying and testing cable PVC insulated screended PVC bedded , galvanised steel strip armoured, electric power cables (heavy cable ) with stranded aluminium conductor , 1100 Volts grade of size 1 core 630 Sqmm complete all as specified and directed by Engineer-in-charge.
Supply and laying or fixing or passing through pipe, 1100 V grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape arourmed in service connection of size 16 Sqmm 2 core multi stranded conductor complete all as specified and directed by Engineer-in-charge.
Supply laying and testing cable XLPE insulated screended PVC bedded , galvanised steel strip armoured, electric power cables (heavy cable ) with stranded aluminium conductor , 1100 Volts grade of size 3.5 core 240 Sqmm complete all as specified and directed by Engineer-in-charge.
PCC 1:4:8 type D2 using 40mm graded stone aggregate as mass concrete for surfacing under GOD switches and LT panels complete all as specified and directed by Engineer-in-charge.
Supply and fix cable jointing kit for 11 KV grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size70-95 Sq mm 3 core complete all as specified and directed by Engineer-in-charge.
Supply and fix LT cable jointing kit for 1100 V grade cable for end joint heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured Aluminium conductor cable of size 16-70 Sq mm 3.5 core complete all as specified and directed by Engineer-in-charge.
Supply and fixLT cable jointing kit for 1100 V grade cable for end joint heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured Aluminium conductor cable of size 95-240 Sq mm 3.5 core complete all as specified and directed by Engineer-in-charge.
Supply and fix LT cable jointing kit for 1100 V grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured Aluminium conductor cable of size 16-70 Sq mm 3.5 core complete all as specified and directed by Engineer-in-charge.
Supply and fix LT cable jointing kit for 1100 V grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured Aluminium conductor cable of size 95-240 Sq mm 3.5 core complete all as specified and directed by Engineer-in-charge.
Removal of vegetation/undergroth/bushes in the premises of E/M installation (DG Set / 2Pole/4poe structure/ transformer) by using mechanicl bush cutter where deemed necessary and cleaning the creepers growing on fencing of the installation once in a month and removal of waste vegetation to nearest dustbin or location as decided with periodicity of once in a month complete all as specified and directed by Engr-In-Charge. (Note any T&P and transportation required for removal of vegetation from installation is deemed to be included in the quoted rates, contractor is advised to quote rated accordingly.)
Scraping of old paint from the steel tubular pole with out removing accessories and preparation of surfaces for repainting . Repainting the pole with one coat of alternative white and black straps of 30 cm each upto 1.5 mtr height using synthetic enamell paint .Repainting the remaining pole and clamps GI bkt etc above 1.5 mtr height by applying one coat of alumn paint complete all as specified and directed by Engineer-in-charge.
Painting of street light PCC pole without removing accessories with one coat of alternative yellow and black straps of 30 cm each upto 1.5 mtr height using synthetic enamell paint .Colour washing the pole above 1.5 mtr height using snowcem of approved colour including painting the steel parts i.e clamps GI bkt etc by applying one coat of alumn paint complete all as specified and directed by Engineer-in-charge.
Scraping of old paint from the LT three phase bus bar chamber of any size fixed on channel without removing and preparation of surfaces for repainting externally by applying two coat of synthetic enamel powder coated of approved colour complete all as specified and directed by Engineer-in-charge.
Supply errect pin type porcelain vitreous brown insulator including one galvanised mild steel spindle,two galvanised iron washers and one galvanised iron nuts of size 100 mm height and 65 mm dia suitable for 1100 volts grade voltage pressure complete all as specified and directed by Engineer-in-charge.
Supply and fix shackle type vitreous brown or white insulator including galvanised mild straps, washers insulator,bolts wahsers and nuts of size 100mm height and 115 mm dia suitable for 1100 volts grade complete all as specified and directed by Engineer-in-charge.
Re-stretching of aluminium conductor any size and length complete including removing kinks and providing new binding wire /Jumper where required complete all as specified and directed by Engineer-in-charge.
Supply and fixing for loop type insulator porcelain vitreous white, brown or green large size with overall dimension 90 x 140mm clearance of hole 25.5mm complete all as specified and directed by Engineer-in-charge
Supply, installation, connecting electrically & commissioning LT feeder box , outdoor type of size 0.90x0.60x0.40 Mtr size factory fabricated made out of MS sheet of thickness 3.15 mm front and back door openable with locking arrangement mounted on angle iron legs made out of angle iron of size 40x40x6 mm , 1.5 mtr long , 1.0 mtr above ground level and 0.50 mtr embedded in PCC blocks of size 0.30x0.30x0.50 mtr -04 Nos duly painted with two coats of synthetic enamel paint over a coat of red oxide complete with 400 Amps rated aluminium bus bar suitable for 3 phase 4 wire supply dully drilled holes for cable connection mounted on epoxy based post insulators and one No. MCCB 200 AMP,35 KA, 3 Pole 415 V complete all as specified and directed by Engineer-in-charge
Earthing complete with galvanised steel earth plate electrode 600x600x6mm burried directly in ground not less than 2.25 mtr deep below normal ground level with top edge of earth plate not less than 1.5mtr below normal ground level connected to the Galvanised iron strip 32x6mm size by means of bolts ,nuts,check nuts and washers of galvanised iron and 32x6mm GI strip procted by provision of GI light grade pipe 40 mm bore incl provision of concrete pit in PCC1:2:4 type B-I , using 20 mm graded stone aggregates with 40 mm thick cover of RCC (1:2:4) reinforced with XPM weight not less than 4 Kg /Sqm and 6mm dia bar handle ,excavation and earth work in any type of soil ,charcoal dust and salt light grade GI watering pipe 20 mm bore with funnel and wire mashand medium grade GI protection pipe 15mm bore 5 Mtr long and GI strip upto main earthing of pole complete all as shown in electrical plate No 5 of MES Sch 191 Part-I all as specified and directed . On testing after completion if the desired resistenance is not obtained the contrator shall redone the earthing without any extra cost to the department .
Supply and fixing of EMS system suitable for 20 KVA to 160 KVA complete as per sample all as directed by Engr-In- Charge.
Welding / brezzing of broken DG Set canopy door / bus bar pannel door with suitable size of CI/MS hinges to suitable for locking arrangement to all type of doors and painting the same door as per existing colour complete all as specified and directed by Engr-In-Charge.
Periodical mainteneance of DG Set complete cleaning of all Elecrtical & machnical part of DG set with control system including cleaning of fuel filter, lub oil filter, by Pass filter, air filter, water seperator, diesel tank and raiator complete all as specified and directed by Engr-In-Charge. (Note :- Fuel filter , Lub oil filter , by pass filter , air filter shall be replaced if required under respective items of this Sch under). (a) DG Set of Capacity 400 KVA
(b) DG Set of Capacity 320 KVA
(c) DG Set of capacity 160 KVA to 200 KVA
(d) DG Set of capacity 100 KVA to 125 KVA
(e) DG Set of capacity 75 KVA to 82.5 KVA
(f) DG Set of capacity 10 KVA to 40 KVA
Supply only for item no 36 (a) following items of DG Set of cap 400 KVA , (a) Fan belt as per sample
(b) Lub oil filter .
(c) Fuel filter element .
(d) By pass oil filter .
(e) Air cleaner, inner element and outer .
Supply only for item no 36.01 (b) following items of DG Set of cap 320 KVA , (a) Fan belt as per sample
(b) Lub oil filter .
(c) Fuel filter element.
(d) By pass oil filter .
(e) Air cleaner, inner element and outer set .
Supply only for item no 36.02 (c) following items of DG Set of cap 160 KVA to 200 KVA , (a) Fan belt as per sample
(b) Lub oil filter .
(c) Fuel filter element .
(d) Air cleaner, inner element and outer .
Supply only for item no 36.03 (d) following items of DG Set of cap 100 KVA to 125 KVA , (a) Fan belt as per sample
(b) Lub oil filter .
(c) Fuel filter element .
(d) Air cleaner, inner element and outer .
Supply only for item no 36.04 (e) following items of DG Set of cap 75 KVA to 82.5 KVA , (a) Fan belt as per sample
(b) Lub oil filter .
(c) Fuel filter element .
(d) Air cleaner, inner element and outer .
Supply only for item no 36.05 (e) following items of DG Set of cap 10 KVA to 40 KVA , (a) Fan belt as per sample
(b) Lub oil filter .
(c) Fuel filter element.
(d) By pass oil filter .
(e) Air cleaner, inner element and outer set .
Repair / maintenance of AMF panel complete including replace of minor defective parts & wire and make serviceable to automatic on/off DG Set and testing complete all as specified and directred by Engineer-in-charge
Supply and fixing in replacement of Over/under voltage Relay 3 phase 415 volts AC complete all as specified and directred by Engineer-in-charge
Supply and fixing in replacement of Engine starting / stopping Relay 12 / 24 Volt DC complete all as specified and directred by Engineer-in-charge
Supply and fixing in replacement of AC Timer 230 Volts having adjustment 0-60 Seconds complete all as specified and directred by Engineer-in-charge
Supply and fixing in replacement of DC Timer 12/24 Volts having adjustment 0-60 Seconds complete all as specified and directred by Engineer-in-charge
Supply and fixing of cranking relay 12/24 Volts complete all as specified and directred by Engineer-in-charge
Supply and fixing of DC relay multipin 12/24 Volts complete all as specified and directred by Engineer-in-charge
AVR of DG Set 100 KVA to 400 KVA complete all as specified and directred by Engineer-in-charge
AVR of DG Set 10 KVA to 82.5 KVA complete all as specified and directred by Engineer-in-charge
Shut down Valve 24 volts as per sample complete all as specified and directred by Engineer-in-charge
Supply and fixing of Battery Charging alternator with inbuilt regulator of DG Set complete all as specified and directred by Engineer-in-charge
Supply and fix of lub oil pump complete all as specified and directred by Engineer-in-charge
Supply and fix of electromechnical governer of DG set 10 KVA to 400 KVA complete all as specified and directred by Engineer-in-charge
Supply only coolant complete all as specified and directred by Engineer-in-charge
Supply only distilled water for battery refilling complete all as specified and directred by Engineer-in-charge
Repair/maintenance to battery charger upto 60 Volt including rewinding of transformer, rectifier assy, switches, ammeter, voltmeter etc if required complete all as specified and directred by Engineer-in-charge.
Repair to radiator assy Cleaning washing thoroughly, de- scaling and M&L for replacement of rubberize paid and MS Nut & Bolts including brazing /repair of cooling tubes with dismantling and segregation upper and lower chamber (tank) including and reassembling any type any capacity complete all as specified and directred by Engineer-in-charge
Dismantling the alternator assembly of DG set of capacity 10 to 82.5 KVA from the foundation after disconnecting the electric connection,carrying the same to workshop,dismantling of alternator and taking down worn out windings of rotor field coils and excitor coils,rewinding the stator,rotor and excitor gauge,replacement of insulation material,heat varnishing provision of connecting leads and terminal plates etc to make the alternator fully serviceable,reassembling the alternator shifting back to the installation ,assembling the same with engine making electric connections,testing and commissioning complete all as specified and directed by Engineer-in-Charge.
All as per item no 60 here in before but for DG Set of cap 100 KVA to 320 KVA complete all as specified and directred by Engineer-in-charge
Repair to self starter with replacement of carbon brushes,pinion,rewinding of starter and rotor winding ,replacement of defective bents etc to make the starter fully serviceable and testing for DG Set any make and following capacity :- (a) 160 KVA to 320 KVA
(b) 10 KVA to 125 KVA complete all as specified and directred by Engineer-in-charge
Repair to DG Set control panel any type incl replacement defective sensors like AMF module , relay card / board ,current transformer ,key switch , indiators , warning ,push button and checking wiring complete including made functional all the system/controls complete all as specified and directed by Engineer in charge
Repair to ATS control panel any type incl replacement defective sensors like AMF module , relay card / board ,current transformer ,key switch , indiators , warning ,push button and checking wiring complete including made functional all the system/controls complete all as specified and directed by Engineer in charge
Supply and fixing of maintinance free battery 12 volt 180 AH tubular type including battery leads and initial charging of battery complete all as specified and directed by Engineer in charge
Supply and fixing of maintinance free battery 12 volt 100 AH tubular type including battery leads and initial charging of battery complete all as specified and directed by Engineer in charge
Supply and fixing replacement of contactor 3 pole AC 415 Volts 320 Amp complete all as specified and directed by Engineer in charge
Supply and fix in replacement on load change over switch of capacity 630 amps front operated four pole 415 volts 50 Hz of complete all as required for integrating electrically and connecting with existing panel complete all as specified and directed by Engineer in charge
Supply and fix in replacement on load change over switch of capacity 320 amps front operated four pole 415 volts 50 Hz of complete all as required for integrating electrically and connecting with existing panel complete all as specified and directed by Engineer in charge
Supply and fix in replacement on load change over switch of capacity 200 amps front operated four pole 415 volts 50 Hz of complete all as required for integrating electrically and connecting with existing panel complete all as specified and directed by Engineer in charge
Supply and fix in replacement on load change over switch of capacity 100 amps front operated four pole 415 volts 50 Hz of complete all as required for integrating electrically and connecting with existing panel complete all as specified and directed by Engineer in charge
Supply and fixing of inbuilt auto battery charger fitted in DG set control panel /AMF panel operating 12 Volt 6 Amps to charge battery during main supply having mains , boost , float , battery reverse indicator with electric connection complete all as specified and directed by Engineer in charge.
Fixing/laying only the following itmes complete all as specified and directed by Engineer In Charge. (Item shall be issued under Sch ,B,) (a) 20 mm bore GI tubing light grade
(b) Moving contract.
(c ) Fix Contract
(d) Copper lux of size 70 sqmm to 400 sqmm.
(e) Contractor 3 P 65 Amp to 250 Amp
(f) LT line spacer 2 line to 5 line
(g) MCCB 3P/4P, 160A - 400A
(h) Spaire contract kit for contractror 70A to 300 Amp
(j) Cable end joint kit 95 sqmm 3 core
(k) Cable st through joint kit 95 - 120 sqmm 3 core
(l) Truly vertical position steel /PCC pole 9/11 mtr long any size
(m) Copper cable 2.5 Sqmm 3 core /16 Sqmm 3 core
(n) Over head line jumper any size
Supply, fixing, jointing and connecting aluminium conductor, steel reinforcement including proper binding complete all as specified and directed by Engineer-in-charge
satpal and brothers
INDERJIT SINGH
KEWAL SONS
SATISH AND CO
Ashoka Engineers
M/S SINGHAL ENGINEERS
Vijay Kumar Contractor and Engineers
JATINDER CONSTRUCTION COMPANY PRIVATE LIMITED
RAJESH SHARMA AND COMPANY
KALSI CONSTRUCTION CO
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .