| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.8 LAccepted-AOC | ₹3.8 L | L1 | Accepted-AOC L1 |
| 2 | L2₹3.9 LRejected-AOC | ₹3.9 L | L2 | Rejected-AOC L2 |
| Sl No | Description | Qty | Unit | WINTRACK CONSTRUCTIONS L2 | LK Constructions L1 |
|---|---|---|---|---|---|
| 1.00 | FULLY AUTOMATIC AIR BREAK AUTO TRANSFORMER STARTER WITH SINGLE PHASING PREVENTOR WITH AMMETER CONFIRMING TO IS 8544 Part IV WITH AUTO RESTART FACILITY
Supply and delivery of Fully Automatic Auto Transformer Starter suitable for the motor offered. Floor mounting type air/ oil cooled Auto Transformer Starter with tapings at 50%, 65%, 80%, housed in robust steel chamber with arc and main contacts confirming to IS 8544 Part IV and as amended therafter for operation in AC three Phase 50 Hz (+/- 5%), 415V (+/- 10%) with the following components, under voltage release with no volt coil, over load relay with dash pot arrangements, single phasing preventor, LED ON/ OFF switches, Mounted Ammeter, Earth leakage relay, contactor assembly suitable for next standard KW rating, in coming and out going cable entry provisions, transformer tank including first filling of oil etc.80hp (WD-M1956) | 1 | Each | 2,18,446 ₹2,18,446 | 2,18,442.2 ₹2,18,442.2 Lowest |
| 2.00 | Labour charges for the erection of submersible pumpset in borewell/openwell including fixing and jointing submersible cable with proper clamps upto the starter to required depth and also fixing of riser pipes to the required depth valves erection clamps, pressure gauges upto the exterior wall of pump room and erection of panel board consisting of TPICN switches starter, Voltmeter, Ammeter, three pilot (indicating) lamps capacitor single phasing preventor, water level guard and laying and jointing the cables and twin earthing as per IE
rules etc., complete and testing the pumpset and trail run for 10 days.Above 50Hp to 85HP (WD-W0877) | 1 | Each | 37,453 ₹37,453 | 37,449.2 ₹37,449.2 Lowest |
| 3.00 | Supply and Delivery of PVC INSULATED AND SHEATHED 3 CORE FLAT TYPE COPPER CABLE CONFORMING TO IS 694/1990 AND AS AMENDED THEREAFTER 10.0 sq.mm | 135 | Rm | 522 ₹70,470 | 518.2 ₹69,957 Lowest |
| 4.00Sub Total | |||||
| 5.00 | GST 18% | 1 | No | 58,746 ₹58,746 | 58,653 ₹58,653 Lowest |
Tender Value
₹4 L
EMD Value
₹4,000
Closing Date
5 Nov 2025, 3:00 pmClosed
Commissioner
Tiruvannamalai City Municipal Corporation
Supply and Installation and Commissiong of 60HP Motor With Fully Automatic Auto Transformer Starter and its Accessories at Samuthira eri Pump House in Thiruvannamalai City Municipal Corporation.
2025_MAWS_616214_16
5779/2025/E1
Open Tender
Civil Works
Works
12 days
Tiruvannamalai City Municipal Corporation
Places Refer Tender Notices
2 documents required · 2 mandatory
₹0
₹4,000
20 Jun 2026
29 Oct 2025
5 Nov 2025
29 Oct 2025
5 Nov 2025
29 Oct 2025
Amount
FULLY AUTOMATIC AIR BREAK AUTO TRANSFORMER STARTER WITH SINGLE PHASING PREVENTOR WITH AMMETER CONFIRMING TO IS 8544 Part IV WITH AUTO RESTART FACILITY Supply and delivery of Fully Automatic Auto Transformer Starter suitable for the motor offered. Floor mounting type air/ oil cooled Auto Transformer Starter with tapings at 50%, 65%, 80%, housed in robust steel chamber with arc and main contacts confirming to IS 8544 Part IV and as amended therafter for operation in AC three Phase 50 Hz (+/- 5%), 415V (+/- 10%) with the following components, under voltage release with no volt coil, over load relay with dash pot arrangements, single phasing preventor, LED ON/ OFF switches, Mounted Ammeter, Earth leakage relay, contactor assembly suitable for next standard KW rating, in coming and out going cable entry provisions, transformer tank including first filling of oil etc.80hp (WD-M1956)
Labour charges for the erection of submersible pumpset in borewell/openwell including fixing and jointing submersible cable with proper clamps upto the starter to required depth and also fixing of riser pipes to the required depth valves erection clamps, pressure gauges upto the exterior wall of pump room and erection of panel board consisting of TPICN switches starter, Voltmeter, Ammeter, three pilot (indicating) lamps capacitor single phasing preventor, water level guard and laying and jointing the cables and twin earthing as per IE rules etc., complete and testing the pumpset and trail run for 10 days.Above 50Hp to 85HP (WD-W0877)
Supply and Delivery of PVC INSULATED AND SHEATHED 3 CORE FLAT TYPE COPPER CABLE CONFORMING TO IS 694/1990 AND AS AMENDED THEREAFTER 10.0 sq.mm
Sub Total
WINTRACK CONSTRUCTIONS (BID ID -1504163)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 4.50 MB
BOQ_738930.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].