Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.3 LAccepted-AOC | L1 | Accepted-AOC Bid accepted being lowest tendrer | |
| 2 | L2₹34.5 L+₹1.0 L (3.08%)Rejected-AOC BALSUA P O JHAKOLARI PATHANKOT PATHANKOT PUNJAB 145001 | PATHANKOT | PUNJAB | 145001 | L2 | Rejected-AOC Other than lowest tendrer hence rejected | |
| 3 | L3₹34.9 L+₹1.5 L (4.48%)Rejected-AOC | L3 | Rejected-AOC Other than lowest tendrer hence rejected | |
| 4 | L4₹35.6 L+₹2.2 L (6.55%)Rejected-AOC | L4 | Rejected-AOC Other than lowest tendrer hence rejected | |
| 5 | L5₹35.7 L+₹2.3 L (6.85%)Rejected-AOC | L5 | Rejected-AOC Other than lowest tendrer hence rejected |
Tender Value
₹40.5 L
EMD Value
₹80,900
Closing Date
26 May 2020, 6:00 pmClosed
CWE Mamun
HQ CWE Mamun Pathankot 145001
SPECIAL REPAIR TO BUILDING NO T-35, T-36, T-37 AND T-38 UNDER GE (NORTH) MAMUN AT MAMUN MIL STN
2020_MES_335640_1
CWE/M-64/2019-20
Open Tender
Civil Works
Item Rate
180 days
GE North Mamun
Class D Category a i
5 documents required · 5 mandatory
₹500
Yes
GE North Mamun
₹80,900
Yes
31 Aug 2020
20 Mar 2020
27 May 2020
20 Mar 2020
26 May 2020
15 Apr 2020
Amount
Taking down chowkhats or frames of any description not exc 1.50 Sqm each with shutters, (without taking off shutters from the frame) including builders hardware , complete all as specified and directed.
Taking down chowkhats or frames of any description exc. 1.50 Sqm and n.exc 4.00 Sqm each with shutters, (without taking off shutters from the frame) including builders hardware complete all as specified and directed.
Demolition of cement concrete (un-reinforced) in ground floors and pavings n. exc. 15cm thickness (below or above ground level) complete all as specified and directed.
M&L for preparation of old painted steel surfaces of any description over 10 cm in width or girth & applying two coats of synthetic enamel paint complete all as specified and directed.
S&F pre-painted galvalume aluminium zinc coating GI base corrugated steel sheet 0.5 thick of an colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws including dismantling of existing sheets complete all as specified and directed.
S&F pre-painted galvalume aluminium zinc coating GI base plain steel sheet 0.5 thick of an colour having tensile strength of 550 Mpa as in ridge / cladding to wall, fixed with self tapping screws including dismantling of existing sheets complete all as specified and directed.
M&L for Cement concrete (1:2:4) type B-1 (using 20mm graded crushed stone aggregates) such as in column for fixing of truss, benching, coping, Bed blocks and the like, rounded or chamfered on edges including necessary formwork complete all as specified and directed.
S&F Anodised powder coated (minimum thickness of powder coating 50 micron) frame for doors, windows, ventilators 114.30 mm x 44.45 x 3.18 mm with one or more rebates including jointing cleats for fixing complete all as specified and directed.
S&F Anodized aluminium door shutters powder coating (any colour decided by GE) of thk not lesss than 50 micron, aluminium section in which size of shutter top members [47.62 x 44.45 x 3.18 mm] , shutter bottom member [100 x 44.45 x 3.18 mm] , shutter vertical members [47.62 x 44.45 x 3.18 mm] and shutter lock rail member of size [63.50 x 44.45 x 2.40 mm] including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos each door, hinges, anodised aluminium snap beading screws complete all as specified and directed.
S&F Anodized aluminium powder coated window and ventilator shutters, glazed shutter having stile and rails size [44.60 x 30.00 x 3.18 mm] thick with triangular aluminium beading of 15 mm size side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings, such as peg stays 150 mm long (1 No), hinges type B-21 100 mm long (2 Nos) suitable handle (1 No) complete all as specified and directed.
S&F Brass mortice lock 4-lever vertical type, size 100 mm complete all as specified and directed.
M&L for Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded wood grain pre-painted PVC sheet ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and wood grain pre-painted PVC sheet for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of wood grain pre-painted PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing complete all as specified and directed.
M & L for Solid PVC Door Frame of size 50mm x 47mm made out of 5mm wood grain pre-painted PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete all as specified and directed.
S&F toilet paper holder chromium plated fixed in repair to wall with CP screwc complete all as specified and directed.
M&L for 4 mm thick sheet glass ordinary quality and glazing with oil putty or fixed with beads/ glazing pins not .exc 0.5sqm in each pane complete all as specified and directed.
M&L for Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm fixed with tinned tacks or galvanized wire staple complete all as specified and directed.
S&F Rolled sections as in cooler stand etc of Fe--410 (grade E-250) quality 'B' complete all as specified and directed.
M&L for Aluminium anodised barrel tower bolt, extruded section 200mm long , complete all as specified and directed.
M&L for Aluminium anodised handle,fabricated type extruded section of size 150 mm complete all as specified and directed.
S&F 150mm long floor door stopper of aluminum alloy body & tongue, anodized, with hard drawn steel spring, fixed with screw etc complete all as specified and directed.
M&L for Brick work (except bricks) (old serviceable bricks retrieved from dismantling shall be used) straight or curved on plan to any radius built in (1:6) including dismantling of brick work or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc and removal of rubbish out off the premises, etc complete all as specified and directed. etc complete all as specified and directed.
M&L for 75mm thick PCC (1:3:6) type C-1 using 20mm graded crushed stone aggregate as in plinth protection laid in slope finished even and fair including making joints at every 2.5 m and at corner filled with bitumen 85/25 and sand in ratio (1:2) by weight including dismantling existing floor of any type and pattern and removal of rubbish out off the premises complete all as specified and directed.
M&L for Formwork to chajjas and similar work including edges for fair finished surface of concrete etc complete all as specified and directed.
M&L for Non-skid ceramic coloured rectified edges joints free tiles 8mm thick area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm as in floors etc, set & jointed in neat cement slurry and pointed in coloured epoxy grout to match laid over and including 15mm thick screed bed or bedding layer of cement mortar (1:4) including dismantling existing floor tiles of any type and pattern including cement mortar bedding and removing debris/tiles out off the premises, etc complete all as specified and directed.
M&L for Glazed ceramic (coloured) tiles 7mm thick, of size 450mmx300mm on vertical surfaces such as dado etc, set and jointed in neat cement slurry and pointed in coloured epoxy grout to match tiles over and including 10mm thick backing coat in cement mortar (1:4), surface finished even and rough to receive tiles, including dismantling existing tiles of any type and pattern including cement mortar backing coat and removal of rubbish out off the premises complete all as specified and directed.
M&L for 10mm thick light shade vitrified ceramic tiles (square/rectangular) polished, area of each tiles not exceeeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in CM 1:4 (surface finished even and rough to receive tile) including roughening surfaces of existing concrete floor by picking, sweeping clean & washing down with water to remove dust and apply neat cement slurry @ 3.00kg of cement per sqm complete all as specified and directed.
M&L for Factory made rubberised coloured chequered tiles of size 250x250x25mm thick (using vibro compaction method) with 3mm to 5mm thick topping in white cement and non fadeble glossy pigment set and jointed in neat cement slurry and pointed in coloured cement to match, laid over and including 15mm thick screed bed or bedding layer of cement mortar (1:4) surface finished even and rough to receive topping over and including 75mm thick PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in sub-base, surface finished even and rough including demolition of existing tiles path of any description and removal of debris out off the premises etc complete all as specified and directed.
S&F 15 mm bore Stop valves/Angle valve cast copper alloy, chromium plated (ISI marked) , screwed down,high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed in repair complete all as specified and directed.
S&F in repair for single towel rail brass chromium plated 600mm long fixed with chromium plated screw and PVC cleat complete all as specified and directed. Make : Cat part No AQN-7711 of Jaquar or equivalent model in Hindware/Marc.
S&F in repair Brass Chromium Plated shower rose with arms fancy type with swivel joints 125 mm face dia of appoved make and cat part for 15mm bore iron pipes complete all as specified and directed. Make : Prayag Cat part No BS-73 or equivalent model in Hindware/Marc.
M&L for Reinforced concrete pipes 200 mm bore ( Internal dia), class NP-2, laid and jointed complete with collars complete all as specified & directed.
M&L concrete bed to drain pipes including forming cradles in cement concrete 1:3:6 type C-2 for 200 mm dia pipe complete all as specified and directed.
M&L for providing cement concrete (1:4:8) type D-2 using 40 mm graded stone aggregates as in foundation, filling and mass concrete complete all as specified and directed.
S&F in repair for 100 mm bore, sand cast, cast iron soil, waste and vent pipe with cement joints, in any length with or without ears, laid in floor complete all as specified and directed.
S&F in repair for 75 mm bore, sand cast, cast iron soil, waste and vent pipe with cement joints, in any length with or without ears, laid in floor complete all as specified and directed.
S&F in repair for 50 mm bore, sand cast, cast iron soil, waste and vent pipe with cement joints, in any length with or without ears, fixed to wall with stack clamp made out of 50mm x 6mm galvanised flat iron fixed with bolt and nuts etc complete all as specified and directed.
S&F in repair for 100 mm bore, cast iron bends (any radius), diminishing pieces or tapers (large bore measured) with oval access door complete all as specified and directed.
S&F in repair for 75 mm bore, cast iron bends (any radius), diminishing pieces or tapers (large bore measured) complete all as specified and directed.
S&F in repair for 100 mm bore, cast iron branch pieces or Tee, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches with oval access doors etc complete all as specified and directed.
S&F in repair for 75 mm bore, cast iron branch pieces or Tee, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches with oval access doors etc complete all as specified and directed.
S&F in repair for 75 mm Cast iron floor trap, with CP grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and directed.
S&F in repair 50 mm Cast iron cowl, fixed with cement joints complete all as specified and directed.
S&F in repair for 15mm bore bib taps fancy type with wall flange, chromium plated cast copper alloy long body with capstan heads, screwed for iron pipe or brass ferrule complete all as specified and directed.
S&F in repair for Rotational moulded polyethylene water storage tanks three layer of capacity 500 litre, (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I including 20mm ball valve high pressure of PTMT with epoxy coated Aluminum rod & high-density plastic ball and dismantling of existing RCC/PVC tank of any capacity, complete all as specified & directed.
Taking up or down 15mm bore pipe and connections including cleaning for refixing including all new fittings for 15mm bore complete all as specified & as directed.
M&L for GI water tubing surface/concealed, 15mm bore, medium grade galvanized with all fittings (such as tee, elbow, socket, union, short pieces) and application of bituminous paint on concealed portion of tubing, fixed to wall or ceiling or laid in floor, complete all as specified and directed. (Note : Cutting chases and making good shall be measured and paid separately)
Refixing of old steel tubing 15mm bore, medium grade galvanized with all fittings (such as tee, elbow, socket, union, short pieces) fixed to wall , floor etc complete all as specified and directed. (Note : Cutting chases and making good shall be measured and paid separately)
Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc and cutting chases for concealed water tubing or concealed conduit wiring, etc, and making good, cutting not exc 10 cm girth complete all as specified & directed.
Taking up or down 20mm bore pipe and connections including cleaning for refixing including all new fittings for 20mm bore complete all as specified & as directed.
M&L for GI water tubing surface/concealed, 20mm bore, medium grade galvanized with all fittings (such as tee, elbow, socket, union, short pieces) and application of bituminous paint on concealed portion of tubing, fixed to wall or ceiling or laid in floor, complete all as specified and directed. (Note : Cutting chases and making good shall be measured and paid separately)
Refixing of old steel tubing 20 mm bore, medium grade galvanized with all fittings (such as tee, elbow, socket, union, short pieces) fixed to wall , floor etc complete all as specified and directed. (Note : Cutting chases and making good shall be measured and paid separately)
M&L for Rendering 15mm thick in two layers base layer 10mm thick in CM 1:6 & finishing layer 5mm thick in cement mortar (1:4) using liquid water proofing compound [ In 2nd layer only] on brick work or concrete surfaces of wall, surfaces finished even and smooth using extra cement including taking down cement or cement lime plaster of any description and raking out joints, hacking for key, scrubbing down with water and removal of rubbish, out off the premises, etc complete all as specified & directed. (Note : WPC shall be measured and paid separately)
M&L for rendering 10mm thick on brick work or concrete surface in CM (1:6) on wall surfaces finished even and smooth using extra cement including taking down cement or cement lime plaster of any description and raking out joints, hacking for key, scrubbing down with water and removal of rubbish, out off the premises complete all as specified & directed.
S&F in repair 20mm bore gun metal gate valve, with cast iron wheel head, screwed both ends for GI pipe and fixed cast copper chromium plated fancy type alloy ISI marked with crutch or butterfly screwed down for GI pipe 20 mm dia complete all as specified and directed.
S&F in repair for Vitreous china wash hand basin, white, flat back, size 550x400mm (Make : Jaquar Cat part No CNS-WHT-801 or equivalent of Hindware/Parryware/Somany) including 15mm bore Pillar taps, cast copper alloy, with capstan heads, chromium plated (Make : Jaquar Cat part No CON-021KN or equivalent of Hindware/Marc.) brackets, CP waste coupling, 32mm bore PVC waste outlet pipe of min 600mm long, including cutting for and pinning in end of brackets complete all as specified and directed.
S&F in repair for Vitreous china white wash down water closet pan (pedestal pattern) with normal closing seat cover S-trap (Make : Jaquar Cat part No CNS-WHT-553SN or equivalent Cat Part/Model of Hindware/Parryware/ Somany) & hand shower (Health foucet) 8mm dia 1.5m long flex tube in chrome finish and wall hook with NRV (Back flow preventer) and connection to drain (or out going pipe) (Make : Jaquar Cat Part No ALD-577 or equivalent Cat Part/Model of Hindware/Parryware) and to flush pipe, antisyphonic pipe etc complete all as specified and directed
S&F in repair for PVC flushing cistern dual flush type 10 Ltr capacity, valve-less syphonic action type, low level, complete with inlet, ball valve, handle, including brackets/pins, PVC flush pipe 32mm bore complete all as specified and directed.
S&F in repair for PVC connection 15mm size with PTMT nuts of length 450mm long of appoved make complete all as specified and directed.
M&L for Preparation of newly plastered surface and apply two coats of cement base paint over a coat of alkali primer (from same manufacturer ) over complete all as specified and directed.
M&L for preparation of newly plastered surfaces of wall & applying two coats of distemper oil emulsion (OBD) over a coat of primer as per manufacturer instructions (from same manufacturer of OBD) complete all as specified and directed.
S&F False ceiling of 9.5mm thick gypsum tiles (600x600mm) laminated with PVC film on the face side & metalised polyester film on the back side with all four edges sealed with PVC film (shade either plain white or crack) fixed using T grid/Cross-T/Wall angle/level clip & suspenders of standard galvanised sections in a grid size of 600x600mm from manufacturer M/s Saint Gobain or equivalent of Armstong/Everest including taking down existing ceiling board & grid work etc of any type/pattern complete all as specified and directed. Note :- Invoice from company’s authorized dealer shall be submitted with material by the contractor along with dealership certificate. Certificate of genuineness from the manufacturer shall also be submitted by the contractor before getting the material passed from the department.
M&L for providing cement concrete (1:3:6) type C-1 using 20mm graded stone aggregates as in KERB STONE complete all as specified.
S&F in repair for 25mm bore anodised aluminium alloy, single curtain rod (wall thickness not less than 1mm) including fancy type PVC brackets of approved design/pattern, funnels etc suitable for single curtain rod complete all as specified and approved by GE.
Taking down carefully unserviciable/ damaged copper/aluminium surface (batten/coduit or casing caping) point wiring any length for light/fan/socket or power including unscrewing from board (fitting and fixture such as switches, sockets, ceiling rose, lamp holders, brackets, pendent, regulators, sockets, Bracket /sketch fitting etc ) and removing material from site and making good to the disturbed surface to match with existing finish complete all as specified and directed.
M&L for Modular Point wiring using FRLS PVC insulated unsheathed /multi stranded copper conductor cable 1.5 sqmm including 1.5 Sqmm FRLS PVC insulated unsheathed copper conductor earth wire drawn through and including concealed PVC conduit of appropriate size not less than 20 mm dia and 1.8 mm thick including all fittings viz tees, bends, junctions box and approved make sunken modular metal flush gang box and suitable support frame and cover plate (inner/outer) of required modules for mounting modular switches/ sockets etc, connecting earth including cutting groove for concealed wiring, making good to disturb surface of wall/floor with cement mortar and finishes to match existing including connection of cable with MCBs or bus bar shall be done through proper size copper/brass thimble of pin/u type etc (conduit shall be fixed on surface of ceiling with necessary saddles where concealing of conduit is not feasible), for light/fan/bell point complete all as specified and directed. (Note : Modular switch/bell push/fan regulator etc shall be measured and paid separately under respective items.)
All as per Srl item No. 66 above but for 5 pin 5 Amp socket outlet point on independent gang box and suitable support frame and cover plate (inner/outer) controlled by one switch 5Amp one way, etc complete all as specified and directed.
All as per Srl item No. 66 above but for 5 Pin 5 Amp socket outlet point on same board controlled by one switch 5 Amps one way on same gang box support frame and cover plate etc complete all as specified and directed.
All as per Srl item No. 66 above but for one 15Amp socket outlet point concealed using 2.5Sqmm FRLS PVC insulated multi-strand copper conductor wire including 2.5 Sqmm FRLS PVC insulated unsheathed copper conductor earth wire and making good to disturbed surfaces of wall floor to match existing finishes complete all as specified and directed.
S & F modular switch piano type flush button 16 Amp one module, complete all as specified and directed. Make : Legrand Cat Part No 673009/Crabtree Cat Part No ACMSXXW102/Anchor Roma Cat Part No 66104.
S&F Modular Socket outlet, 5 pin, multi purpose, 2 module 6/16 Amp, AC 230 volts, etc complete all as specified and directed. Make : Crabtree (Verona) Cat Part No : ACVKCWW163 Legrand Cat Part No 673455 / Schneider Cat Part No P2106.
S & F modular switch piano type flush button one way 06/10 Amp one module complete all as specified and directed. Make : Legrand Cat Part No 673000/Crabtree Cat Part No ACMSXXW101/Anchor Roma Cat Part No 66111.
S&F Modular Socket outlet, 5 pin, multi purpose 2 module 2 in 1, 6 Amps, AC 230 volts, etc complete all as specified and directed. Make : Crabtree (Verona) Cat Part No : ACVKSWW065 or equivalent of Legrand/Siemens/Schenider/Anchor Roma.
S&F Ceiling rose polycarbonate isolated body surface Bakelite 65mm, three terminals, AC 230 volts etc complete all as specified and directed.
S & F Fan regulator modular step type suitable for 1200/1400mm sweep ceiling fan hum free, 120W- 2 module including necessary connections complete all as specified and directed. Make : Legrand Cat Part No 673028/Crabtree Cat Part No ACARFHW005/Anchor Roma Cat Part No 66502.
S&F Modular bell push, 10 Amp, AC 230 Volt etc complete all as specified and directed. Make : Legrand Cat Part No 673404/ Anchor Roma Cat Par No 289101/ Schneider Cat Part No P1005.
S&F for Bell Ding Dong AC 230 Volt, single Pole complete all as specified and directed. Make : Anchor Cat Part No 8024/Cona Cat Part No 2856/ Anchor Cat Part No 8272/GM Cat Part No 4001.
Taking down exhaust fan of any sweep & size and refix in same position after overhauling including minor repairs by replacement of capacitor, safety pin, cap, nuts & bolts etc and making connection using 3 core, 0.50 Sqmm PVC insulated and overall sheathed flexible copper conductor cable from ceiling rose to fan, including testing to ensure efficient functioning including application of one coat of synthetic enamel paint by spray painting & rewriting number complete all as specified and directed.
S &F the Bulk head light fitting LED type 10 watt complete with 10 watt LED and having IP-63 protection and fixing on wall/ceiling complete with all accessories and including connecting up with ceiling rose with & including PVC insulated and overall sheathed flexible copper conductor cable and including 3 core 0.50 Sqmm complete all as specified and directed.
M&L for 1x20 Watt white powder coated CRCA Box type LED batten with decorative end cap including polycarbonate LED tube lighting fixture, energy efficient, 230 volts wall mounted complete with all accessories internally pre-wired and including connecting up with 3 core twisted flexible copper conductor cable of suitable size including taking down old UNSV tube light fitting any type, complete all as specified and directed.
S & F mirror light 10 watt LED type with all accessories including inbuilt lamp connecting electrically to ceiling rose using cord flexible 3core PVC insulated over all sheathed with flexible copper conductor of size 0.75 sqmm complete all as specified and directed.
S&F decorative wall mounting bed side light 3 watt fitting LED type having flexible neck complete all as specified and directed.
S&F the wall mounted type fancy light fitting suitable for retrofit LED Lamp B22 including 9 watt LED bulb and with decorative diffuser and mounting clips and lamp holder, wall arrangment complete all as specifeid and directed. Notes for Srl item No 79 to 83:- 1. Driver shall be potted antivibration type. 2. LM-79 and LM-80 test report with 1 Lakh burning hours LED life from NABL lab shall be povided. 3. CRI (Colou Rendring Index) of fixture shall be > 70. 4. CCT (Colout Correlated Temprature of fixture shall be 5700K ± 300 K. 5. System Lumen Efficacy shall be > 100Lm/W 6. 10 KV separate Surge Protection shall be provided as a part of fitting. 7. 5 years gurantee shall be provided by contractor suppoted by OEM covering all parts of luminaire. 8. Lenses shall be Modular Type. 9. PCB used shall be MC PCB type 10. The defect liability period of LED light shall be 05 years from the certified date of completion & the Contractor shall replace / repair the defective fitting within 07 Days after handing over to Contractor for replacement / repair 11. CA No shall be written on each fitting before installation. 12. The name of manufacturer to be embossed on the fitting. 13. The fittings shall have arrangement so that maintaince required, if any can be carried out from Top cover.
S&F for MCB single pole (SP) 240 volts, 6 to 32 Amps, 10KA (C-series) , complete all as specified and directed. Make : Legrand/Schneider/Hager
S&F for MCB single pole (SP) 240 volts, 40 to 63 Amps, 10KA (C-series) complete all as specified and directed. Make : Legrand/Schneider/Hager
S&F for MCB single pole neutral (SPN) 240 volts, 40 to 63 Amps, 10KA ((C-series) complete all as specified and directed. Make : Legrand/Schneider/Hager
Supply, Installation, connecting & testing of tamper proof electronic AC 3x240 Volts, 50Hz, Single phase, multi feature static energy meter ISI marked of rating 10 to 60 Amps with backlit LCD digital disply with special feature like TOD, Tamper logging, Optical communication port for down loading the data and push button for manual operation to read the data without opening box, two wire direct operated of accuracy class 1.0, Operating voltage 140V to 300V, (measures & display KWH, V, I, KW, PF, last one months history of kWh & MD in KW) including factory fitted hinged meter box made out of polycarbonate engineering plastic transparent pilfer proof to house energy meter (as per IS-5133 Part-II) with protection class IP-51, Dust proof, vermin proof, Shock proof with 9 Pin D type male connector of the cable used as interface between meter and CMRI and push button including painting contract number on box and sealing the cover of box & taking out existing electric meter with or without box of any type and deposited to MES store yard etc complete all as specified and directed. Make : HPL Cat Part No SPPB1521120002ME03 or equivalent of Secure/AMTL/L&T
S&F in replacement distribution board iron clad,double door with IP-43 protection suitable for MCCB as incomer and MCB as outgoing 415 Volts 3 phase 50 C/S '4' way, complete with and including approriate size copper busbar and neutral link complete with and including one MCCB 3 pole 415 Volts 100 Amps rating with rupturing cap 16 KA of the same make as of distribution board & including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site or directed by Engr-in-Charge. [Note :- Outgoing MCB only shall be measured and paid separetly]
S&F in replacement double door MCB DB made out of 18 SWG CRCA steel sheets, Phosphates powder coated with copper bus bar, Earth stud, Din Rail, Polyamide Terminal Blocks for incoming and outgoing circuits, inbuilt loose wire box, Ground terminal blocks, duly pre-wired with thimble flame retardant copper conductors and poly layer for protection SP 240 volts 200 Amps rated bus bar 2+6 way double door open able complete, including taking out old unsv MCB DB any size/type complete all as specified and directed. Make : Legrand/Schenider/Hager
M&L for Sub main wiring with FRLS PVC insulated unsheathed 2X6 sqmm multistranded copper conductor cable 1100 V with 1X6 sqmm FRLS PVC insulated green multistranded copper cable for continuous earth drawn through & including concealed PVC conduit of appropriate size not less than 20 mm dia & 1.8mm wall thickness with all accessories including cutting grooves and making good disturbed surface to match existing including taking down existing surface sub main wiring complete all as specified and directed. (Note: Two runs of FRLS PVC cable with one run of earth conductor and conduit shall be measured as one RM.) Make for wiring : Polycab/Anchor/Finolex
Supply , laying, testing and commissioning for 1100 volt grade XLPE insulated heavy duty cable, 25 sqmm 4 core, strip armoured with aluminium stranded conductor overall PVC sheathed laid in trenches including taking down existing cable & bricks complete all as specified and directed. Note : Excavation & Earthwork shall be measured and paid separately.
M&L for earthing complete with galvanised steel earth plate electrode, 600mm x 600mm x 6mm thick, buried directly in the ground (earth pit not less than 2.25m deep below normal (ground level) with top edge of the plate not less than 1.50m below ground level connected to galvanized iron wire 4mm dia as earth lead by means of bolts, nuts and washers of GI up to test point, HDPE pipe 15mm bore as protection pipe, GI watering pipe 20mm bore light grade with funnel and wire mesh, charcoal and salt, 40mm thick pre-cast RCC (1:2:4) type B-0 (Nominal mix) cover reinforced with XPM (weighing n.less than 4 Kg/Sqm) with suitable steel handle, and angle iron 40X40X3mm frame and chamber of PCC (1:3:6) type C-0 (including earth work in any type of soil, removal of surplus soil to a distance n.exc.50m) and connecting, testing on completion, all as shown on electric plate No. 03 of SSR-2009 Part-I, complete all as directed. Notes: 1. Earth lead & protection pipes length upto & including 7.50 metre is deemed included in unit rate quoted by the contractor. 2. Earth filling shall be done by vegitable soil. 3. Soil shall be free from stone, boulders, aggregate, gravels .
Excavation in trenches n exc 1.5m wide and n exc 1.5m in depth for foundation etc (for cable, pole stay manhole etc), in any type of soil and getting out, complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc. 25cm thick, etc complete all as specified and directed.
Removing excavation material n exc. 50m & deposited where directed at a level n exc. 1.5m above the starting point etc complete all as specified and directed.
M & L for well burnt bricks , laid flat ( old size) sub class B designation 75 for cable protection complete all as specifed and directed.
M & L for sand filling in trenches dry and and clean sand unwashed including punning around cable for protection of under ground cable complete all as specified and directed. [Note : Punned thickness shall be measured and paid]
S&F for GI tubing 40 mm bore light grade laid in trenches/floors/ fixed to wall/poles for protection of cable with necessary fittings and FI clamps duly painted complete all as specified and directed.
S&F Single pole & neutral enclosure with a two pin & earth plug & socket complete with & including one single pole MCB 20 Amps 240 volts (C-series) complete all as specified and directed. Make : Legrand/Schneider/Hager
GANDOTRA CONSTRUCTION CO
M/S J N TRADERS
A V BUILDERS
Ms Tarsem Kumar Sharma
D R CONTRACTORS
M/s Ashoka Brothers
Raghbir chand
M/s. RAMESH KUMAR
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .