Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹2.3 LAccepted-AOC 30 CHETNA VIHAR INDIRA NAGAR INDIRA NAGAR LUCKNOW UTTAR PRADESH 226016 | LUCKNOW | UTTAR PRADESH | 226016 | 1 | Accepted-AOC Quoted rates are reasonable and justified. |
Tender Value
Refer Docs
EMD Value
₹4,939
Closing Date
19 Jun 2025, 6:00 pmClosed
EE(E) Prayagraj
2nd Floor, CTO Compound, Nawab Yusuf Road PRAYAGRAJ-211001
Restoration of automatic fire detection and Fire alarm system in IP TAX switch room in M/W bldg. Prayagraj.
2025_BSNL_237936_1
06/EE/E/BSNL/ED/PRYJ/2025-26
Open Tender
Electrical Works
Item Rate
30 days
Prayagraj (UP)
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
AO( Cash) O/o PGM BSNL BA Prayagraj
₹4,939
14 Jul 2025
10 Jun 2025
21 Jun 2025
10 Jun 2025
19 Jun 2025
10 Jun 2025
Supplying & laying of 2 x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.
Supplying and drawing following size of FRLS PVC insulated copper conductor single core cable in existing surface / recessed steel/PVC conduit etc. as required.
2 x 1.5 sq. mm
3 x 1.5 sq. mm
4 x 1.5 sq. mm
5 x 1.5 sq. mm
6 x 1.5 sq. mm
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface codouit or cutting the wall and making good the same in case of recessed conduit as required.
Replacement of faulty / burnt smoke detector builtin LED and mounting base with new one i/c installation, testing & commissioning commplete with all connections etc. as required.
Replacement of manual call boxes with new of MS construction in surface/recess with stainless steel chain & hammer assembly complete with glass and push button i/c testing & commissioning etc. as required.
Replacement of faulty /burnt response indicator with new one on surface/recess MS box having two LEDs metallic cover i/c installation, testing & commissioning complete with all connections etc. as required.
Replacement of faulty fire alarm sounder with new one having facility to make announcement, mounted in M.S. box (16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. i/c testing & commissioning complete as required.
Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections as required.
6 Zones
Replacement of life expired /damaged 4.5 Kg. CO2 type fire extinguisher with suitable hose pipe & horn etc complete as reqd.(M/s Minimax or SS make) (Note: Certificate of explosive deparment should be submiited.)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .