| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹36.8 LAccepted-AOC | L-1 | Accepted-AOC FOUND LOWEST AND REASONABLE | |
| 2 | L-2₹38.0 L+₹1.2 L (3.13%)Rejected-Finance | L-2 | Rejected-Finance Being other than lowest | |
| 3 | L-3₹40.0 L+₹3.1 L (8.54%)Rejected-Finance | L-3 | Rejected-Finance Being other than lowest | |
| 4 | L-4₹40.3 L+₹3.5 L (9.51%)Rejected-Finance H O 325 JAIPUR HOUSE AGRA 282010 | AGRA | UTTAR PRADESH | 282010 | L-4 | Rejected-Finance Being other than lowest | |
| 5 | L-5₹40.7 L+₹3.9 L (10.5%)Rejected-Finance VILL NANDA KA NAGLA DHAOLI AGRA 282001 | AGRA | AGRA | UTTAR PRADESH | 282001 | L-5 | Rejected-Finance Being other than lowest |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
9 Feb 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) TECH ARE AGRA
GE (AF) TECH ARE AGRA
COMPREHENSIVE MAINT/ REPAIR TO DISPERSAL, TAXI TRACK AND LINKS AT AF STATION AGRA UNDER GE(AF) TECH AREA AGRA.
2021_MES_414530_1
8200-1307/E8
Open Tender
Civil Works
Item Rate
180 days
GE (AF) TECH ARE AGRA
As pet Tender Documents
7 documents required · 7 mandatory
₹500
Yes
GE (AF) TECH ARE AGRA
₹98,000
Yes
13 Mar 2021
20 Jan 2021
11 Feb 2021
20 Jan 2021
9 Feb 2021
27 Jan 2021
20 Jan 2021 - 23 Jan 2021
60 days
Amount
Demolition of un-reinforced cement concrete of any description and in any position not otherwise specifically provided for and disposal of rubbish exc. 250 mtr but n.exc 500 mtr away as directed by Engr-in-charge complete all as specified and as directed.
M/L 100 mm thick PCC 1:2:4 type B2 [using 40 mm graded stone aggregate ] as in flooring , finish the surface even and smooth without using extra cement completee all as specified and directed.
Demolition of reinforced cement concrete (reinforcement cut as reqd to facilitate demolition)) in any positionie. drain cover etc and disposal of rubbish exc. 250 mtr but n.exc 500 mtr away as directed by Engr-in-charge complete all as specified and as directed.
M&L precast RCC 1:2:4 using 20mm graded stone aggregate as in cover slab including necessary formwork etc and set in cm 1:6 complete all as specified and directed .
M&L for TMT bars 10 mm dia and over as in reinforcement cut to length, bent to shape required including bending, cranking and hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and as directed.
M&L for racking out joints upto a depth of 25mm, saw cutting the vertical sides of joints for making edges of joints straight upto the possible extent by keeping maximum width of joint 10 to 15 mm, cleaning all loose particle/dust from the joints by using brushes, compressed air, blowers etc, fixing masking tape along either side of the joints, placing back up sheet 10 to 12 mm thick in position and filled with polyurethane based sealing compound (pitch free ) having 3 mm recess from top of joint after applying suitable primer as per manufacturer's instructions and removing masking tap, complete all as per manufacturer's instructions and directed at site.
ditto- all as per item No 6 above but width or joint 16 to 25 mm
ditto- all as per item No 6 above but width or joint 26 to 40 mm
M&L for chipping/cutting of cracked/broken edges of cement concrete pavement by cutting inverted trapezodial section in regular shapes by dimand cutter or by the chisel removing loose particle, unsound material and cleaning the surfaces by the air compressor and removal of demolished materials/debris to a distance exc 250 mtr but n.exc 500 mtr and applying one tack coat of primer of epoxy consisting of araldite GY-250 of 100 parts PBW and Aradur 140 of 50 part PBW and there after at an interval of 30 to 45 minutes pits shall be filled with the epoxy mortar consisting of the following complete all as specifed and directed:- (a) Epoxy resin primer : - (i) Epoxy resin (Araldite) Gy -250 : 100 Part each by wt (ii) Aradur 140 : 50 part each by wt (b) Epoxy mortar : - (i) Aradur 140 : 50 part each by wt (ii) Araldite of Gy 250 : 100 Part each by wt (iii) Silica sand M-12 grade : 600 Part each by wt
M&L for repair to damaged broken portion of existing PQC slabs of taxi tracks/ runway using elastomeric concrete in form of potholes measuring 10 to 50 mm diameter and average depth of 50mm by cutting to the required depth until hard strata of concrete is achieved, cleaning the surfaces and removing loose material, dust etc using air compressor and priming the surfaces with special primer RDL 942 and treating the surface with elastomeric concrete Flex O Patch (10 kg kit of three part viz part A-3.0 Kg, Part B-1.50 Kg and Part C-5.5 Kg (E-crete aggregate) and levelling the surface using trowel and cleaning the surface to match the existing surfaces complete all as specified and direceted
Supply and laying dry clean sand spreading, leveling in layers 10mm thick consolidated complete all as specified and as directed. Note: Sand for filling shall 1.18mm single size and sand shall pass 100% through 2.36mm sieve and shall be 100% retain on 600 micron sieve.
M & L for Polythene film (transparent colour) in single layer of 400 micron thickness, virgin quality as per ASTM D2103/IS 2508 laid over sand layer with side and end overlapping not less than 150mm complete all as specified and as directed. Note:- (a) Measurement shall be taken for net area and unit rate quoted shall deemed to include for over lapping. (b):- Sand layer will be measured and paid separately under relevant item of this schedule.
M&L for Pavment Quality cement concrete (PQC) work in pavemnt of flexural strength 44 kg/sqcm (lower control limit-LCL) in field using minimum 400kg of cement per cubic metre or as per design mix, mixed with and including traingular/ Non circular synthetic polyster fibre reinforcement @ 0.25% by weigth of cement, spread and compacted by using slip form paver, thickness of concrete 200mm to 330mm as per site requirement all as specified including necessary form work, finishing by brooming / belting, curing etc complete all as specified and as directed. Note:- (a) Construction joints / dummy joints (Contraction joints) and exponsion joints shall be measured and paid separately under respective items. (b) No price adjustment shall be applicable if excess quantity of cement than the minimum is used / approved based on mix design in the execution of work under this item. (c) Cost of admixtures . fibers to maintain as required by design mix is deemed to be included in the rate quoted. (d) Maximum cement content shall be 425 kg / cum and design mix shall be based on the same.
M&L for forming construction joint, 24mm deep and 8mm wide (using diamond cutter) provision of polyethylene backup sheet 12mm thick filled with polyurethane sealant (Minimum depth of sealant above potythelene sheet shall be of 10mm) complying with BS 5212, BS 4254 and EN 141875- 2003 (for hydrolysis/ water resistance test) priming the sites, with minimum MAF + 30% (with 10 years performance guarantee) and applying masking tape on edges of joint to prevent accidantal spillage of sealant and removing the masking tape after sealant is applied by mechanical means all as shown on drawing and all as specified and as directed. Note:- (a) The make of polyethylene rod shall be of brand " DURA board HD 100" manufactured by M/S Supreme Industries Ltd or equivalent of makes listed here-in-before after. (b) The polyethylene rod shall be of desired diameter having minimum density of 22kg/cum and compression strength of 0.40kg/sqm 25% greater than the joint width, of white colour (c) Primer to be used before filling sealant (d) Edge shall be bevelled and jointed cut within 24 hours using diamond bit cutters of Bosch or equivalent used for cutting green concrete. the construction/dummy joint 1st out is to be done after 24 hours of casting, final cut with in 72 hours of casting. Blade for cutting to be replaced after every 32 mtr of cut.
M&L for forming contraction (Dummy) joints, cutting 100mm deep with 3mm width as initial cutting and secondary cutting of 25mm deep from the top and 8mm wide using diamond cutter to accommodate polyethylene backup sheet 12mm thick filled with polyurethane sealant (Minimum depth of sealant above potythelene sheet shall be of 10mm) complying with BS 5212, BS 4254 and EN 141875- 2003 (for hydrolysis/ water resistance test) priming the sites, with minimum MAF + 30% (with 10 years performance guarantee) and applying masking tape on edges of joint to prevant accidental spillage of sealant and removing the masking tape after sealant is applied by mechanical means all as shown on drawing and all as specified and as directed. Note:- (a) The make of polyethylene rod shall be of brand " DURA board HD 100" manufactured by M/S Supreme Industries Ltd or equivalent of makes listed here-in-before after. (b) The polyethylene rod shall be of desired diameter having minimum density of 22kg/cum and compression strength of 0.40kg/sqm 25% greater than the joint idth, of white colour (c) Primer to be used before filling sealant (d) Edge shall be bevelled and jointed cut within 24 hours using diamond bit cutters of Bosch or equivalent used for cutting green concrete .
Siddhi Vinayak and Co
M/S JAWAHAR LAL SHARMA
Rakesh kumar
GIRENDRA SINGH AND CO
JEE JEE BUILDERS
deva engineers
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .