Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.5 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹31.8 L+₹4.8 L (17.7%)Rejected-Finance 205 KRISHNA NAGAR GOLA KA MANDIR NEAR AIRTEL TOWER NO 01 MORAR GWALIOR 474005 | GWALIOR | GWALIOR | MADHYA PRADESH | 474005 | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹33.7 L+₹6.7 L (24.9%)Rejected-Finance N A | NA | NA | 121004 | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹34.2 L+₹7.2 L (26.6%)Rejected-Finance 5 A KALPANA NAGAR 7TH CROSSING MORAR GWALIOR MP | GWALIOR | GWALIOR | MADHYA PRADESH | 474006 | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹35.4 L+₹8.4 L (31.0%)Rejected-Finance 53 SHANTI S SANIK COLONY BAIRAGARH BHOPAL MP 462 030 | BHOPAL | BHOPAL | MADHYA PRADESH | 462030 | L5 | Rejected-Finance Not Lowest |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
11 Oct 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer Gwalior
Garrison Engineer Gwalior Morar Cantt
8994/GWL/E8 REPAIR/MAINT/REPLACEMENT OF LT FEEDER PILLARS AND PANELS AT DIFFERENT OTM/RESIDENTIAL LOCATION UNDER GE GWALIOR
2024_MES_674293_1
8994/GWL/E8
Open Tender
Electrical and Maintenance Works
Works
180 days
Garrison Engineer Gwalior
Please refer tender documents
9 documents required · 9 mandatory
₹500
Garrison Engineer Gwalior
₹90,000
Yes
25 Nov 2024
13 Sept 2024
14 Oct 2024
13 Sept 2024
11 Oct 2024
28 Sept 2024
Amount
Disconnecting and taking out unserviceable indication lamps and supply, fixing, connecting, testing and commissioning of new indication lamps LED type with showing red, yellow and blue colours of 22.5mm dia fixed to monitor on LT panel board suitable for 240 Volts AC supply and making connections with using 1.5 Sqmm PVC insulated unsheathed copper conductor cable complete all as specified and directed.
Supply and fixing any Size/Amp rating of new Aluminium bus bar with colour code insulation of any shape and size including necessary holes/bending/ nut bolts/washers/post insulator etc complete all as specified and directed.
Taking out old unserviceable insulator from LT panel boards and supply, fixing & testing epoxy bus bar insulator in bus bar system including nuts, bolts and washers suitable for LT 415 Volts, 50 Hz AC supply for mounting of bus barsin LT panels/feeder pillar boxes complete all as specified and directed.
Supplying and fixing in existing LT feeder pillar boxes, mild steel sliding door bolt 200 mm size clip & bolt type, stove enameled black, with bright bolt not less than 12 mm dia with and including welding the sliding bolt & staple plate complete all as specified and directed. Note : No welding is permitted.
M&L in renewal of MS Hinge plate in existing feeder piller boxes/panel boards with necessary auto hinged etc including making necessary adjustment by mechanical work for free and smooth movement of door and locking arrangements complete all as specified and directed. Note :- (i) No welding is permitted. (ii) Hinge Not less than 1.5 mm thick. (iii) flange size not less than 100mmX 60 mm.
Renewal of existing unserviceable/damaged part / portion of the existing feeder pillar box/panel boards with supplying and fixing new part or portion fabricated out of 2mm thick MS sheet (CRCA sheet) in position including making necessary adjustments and alignments to make the existing feeder pillar box/ panel board body to required shape(s) complete all as specified and directed. NOTE :- (i). The panel board repaired shall be made totally enclosed, weather proof, wermin proof for installing incoming/outgoing MCCB/Switch fuses/cable etc complete all as specified and directed. (ii) The rates quoted by the contractor are deemed to be with and including necessary cutting, welding, leveling and jointing etc as directed to match & accommodate with the existing feeder pillar box/ panel board.
Preparation of the old decorated existing external and internal steel surfaces of feeder pillar boxes/panels/boards of any description and in any position including removal of disintegrated & deteriorated paint either by hand scrapping or by blow lamps, applying necessary filler coat and stopping as required and applying two coats of synthetic enameled paint (grey in color) with using spray machine on old prepared surfaces complete all as specified and directed.
M&L for Surface excavation over the areas around the poles/feeder piller boxes/sub stations not exceeding 15 cm depth including cleaning the bushes and vegetation and leveling including removal of surplus soil in hard/dense soil complete all as specified and directed.
Supply, fabrication and fixing for mild steel structure such as cross arms, bracing, supports, clamps and back plate fabricated from structural steel sections including nuts & bolts, washers of any description on LT over head line poles/street light poles complete all as specified and directed.
Disconnecting existing LT over heated or burnt cable terminal at existing panel/board/feeder pillar box etc cutting out over heated / burnt / unserviceable and portion of cable, stretching / opening cable to suitable required length from available rings etc and fixing and connecting the cable in position properly by providing suitable new aluminium lugs and suitable GI nuts, bolts & washers sleeves joining kit etc and excavation, refilling deemed to be included in quoted rates complete all as specified and directed for the following sizes of cables (Note : Sleeve, jointing kit paid separetely) :-
25 Sqmm to 95 Sqmm cable of 3.5 Core
120 Sqmm to 185 Sqmm cable of 3.5 core
240 Sqmm to 400 Sqmm cable of 3.5 core
Supply and fix MCCB 4 Pole, 415 V in renewal fixed type, 125 Amps with breaking capacity 25 KA complete all as specified and directed.
Supply and fixing of MCCB 4 Pole, 415 V in renewal Adjustable type, 160 Amps with breaking capacity 25 KA complete all as specifed and directed.
Supply and fixing of MCCB 4 Pole, 415 V in renewal Adjustable type, 200 Amps with breaking capacity 36 KA complete including spreader terminals complete all as specified and directed.
Supply and fixing of MCCB 4 Pole, 415 V in renewal Adjustable type, 250 Amps with breaking capacity 36 KA including spreader terminals complete all as specifed and directed.
Supply and fixing of MCCB 4 Pole, 415 V in renewal Adjustable type, 400 Amps with breaking capacity 36 KA complete including spreader terminals complete all as specified and directed.
Supply and fixing of MCCB 4 Pole, 415 V in renewal Adjustable type, 630 Amps with breaking capacity 50 KA including spreader terminals complete all as specifed and directed.
M&L for Cable joining kit for LT cable for outdoor termination heat shrink type joint complete with joining material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 25 sqmm to 95 sqmm complete all as specified and directed.
M&L for Cable joining kit for LT cable for outdoor termination heat shrink type joint complete with joining material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm complete all as specified and directed.
M&L for Cable joining kit for LT cable for outdoor termination heat shrink type joint complete with joining material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 185 sqmm to 400sqmm complete all as specified and directed.
M&L for LT Cable insulation protection sleeve heat shrink type single core sleeve for LT Cable of size 25 sqmm to 50 sqmm complete all as specified and directed.
M&L for LT Cable insulation protection sleeve heat shrink type single core sleeve for LT Cable of size 70 sqmm to 150 sqmm complete all as specified and directed.
M&L for LT cable insulation protection sleeve heat shrink type single core sleeve for LT Cable of size 185 sqmm to 400 sqmm complete all as specified and directed.
M&L for Straight through joint Heating kits type for LT cable of size 25 to 50 sqmm, XLPE armoured cable 3.5 core complete all as specified and directed.
M&L for straight through Heating kits type for LT cable of size 70 to 150 sqmm, XLPE armoured cable 3.5 core complete all as specified and directed.
M&L for Machine pressed precast concrete interlocking paver block any shape and size including cleaning the bushes and vegetation and leveling including removal of surplus soil in hard/ dense soils and PCC confirming to IS 15658-2006 of 80 mm thickness M-40 Grade complete with curve stone around the interlocking paver blocks complete all as specified and directed.
Material and labour for earthing complete (Including Testing) with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 metre below normal ground level (with top edge of earth plate not less than 1.5 metre below ground level) connected to galvanized iron earth strip of size 32x6 mm (main earthing lead) by means of galvanized bolts, nuts and washers all as shown in electrical plate No 3 of MES Schedule Part-I (2009) with connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 40 mm dia GI pipe medium grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia medium grade for watering pipe with funnel & wire mesh including necessary earth work and PCC (1:3:6) type C-1 (using 20mm graded stone aggregate) for earth pit, internal surface of concrete shall be given 10mm thick plaster in CM 1:4 and 40 mm thick precast RCC cover in 1:2:4 type B1 (using 20mm graded stone aggregate) with 3 Nos 8 mm dia TMT bars both ways with 12mm dia round bar handle complete all as specified and directed. NOTE: Earth strip and its protection pipe upto and including 7.5 mtr only from the top of earth electrode are included under this item and additional earth strip/protection pipe etc if any required at site shall be measured and paid for separately under appropriate item of Schedule `A’
M&L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required 25x4mm size galvanised iron strip complete all as specified and directed.
Dismantling and taking down existing unserviceable/ worn out danger notice plate for LT panel/LT feeder pillar boxes, supply & fixing for danger notice plate 20x15cm size made out of 1.6 mm thick mild steel sheet, duly painted with vitreous enameled white, with letters, figures and conventional skull and bones in signal red colour and fixed with including connected accessories complete all as specified and directed.
M&L for shifting of LT panel from one location to another after disconnecting of all LT cable connections, PCC works and refixing the same after repairing complete all as specified and directed.
Supply, laying and testing of cable XLPE insulated, armoured, heavy duty, electric LT UG cable with multi stranded aluminium conductor, 1100 Volts grade including taking out existing cable of following size complete all as specified and directed :-
25 Sqmm 3.5 core.
35 Sqmm 3.5 core.
70 Sqmm 3.5 core.
95 Sqmm 3.5core.
120 Sqmm 3.5core
Excavation in trenches not exceeding 1.5m wide and not exc 1.5m depth and getting out in hard/dense soil complete all as specified and directed.
Returning, filling, including spreading, leveling, watering and well ramming in layers not exc 25 cm in soft/loose soil complete all as specified and directed.
Removing excavated soil to a distance not exc 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed.
M&L for sand filling/cushioning in trenches for cable protection including consolidation complete all as specified and directed.
Supplying and laying reinforced precast concrete cable cover, type 1 with peak Class LV, Type I, flat of size 250mm x 150mm x 40mm complete all as specified and directed.
M&L for PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and directed.
M&L for PCC 1:2:4 type B-0 using 12.5 mm graded BT stone aggregate as in bed block for hold fast or coping including necessary form work complete all as specified and directed.
Disconnecting & taking out non functional ACB of any description and any make of rating 11KV, 630 Amps to 800 Amps dismantling/opening of the ACB for servicing/over hauling taking out and removing unserviceable/defective parts including cleaning and servicing greasing, oiling of the parts etc and renewal of unserviceable parts with new one, reassembling the ACB after over hauling/servicing and its testing complete all as specified and directed. Note : - The quoted rates of the contractor includes for renewal of unserviceable parts Like : Vertical Terminal Adapter for AH/AHA Fixed type, Isolating contacts Blocks Assembly, Single Phase Resin Cast CTS for "AA/AHA", Main Isolating Contacts (Jaw Contacts) for LT air circuit breakers, Lower terminals with fitting plates, Main Fixed Contacts (Upper Terminals) for LT air circuit breakers etc with new parts)
BEHL CONSTRUCTION CO (BID ID -3127014)
M/s Sree Baba Traders (BID ID -3126939)
M/S SANTOSH CONSTRUCTION CO (BID ID -3125023)
M/s Shanti Enterprises (BID ID -3128627)
M/s DKS Electricals (BID ID -3127916)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .