| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹54 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹72 L+₹18 L (33.3%)Admitted-Finance H NO 698 SECTOR 10 PANCHKULA HARYANA 134109 | PANCHKULA | PANCHKULA | HARYANA | 134109 | L2 | Admitted-Finance | |
| 3 | L3₹74.3 L+₹20.4 L (37.7%)Admitted-Finance | L3 | Admitted-Finance | |
| 4 | L4₹80.1 L+₹26.1 L (48.4%)Admitted-Finance | L4 | Admitted-Finance | |
| 5 | L5₹84.4 L+₹30.4 L (56.4%)Admitted-Finance C O OPPOSITE MH MANDA POONCH ROAD AKHNOOR 181201 J K | JAMMU | JAMMU AND KASHMIR | 181201 | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | SHSS ASSOCIATES L3 | M/S JIWAN SINGH L4 | Usha Engineering Co. L5 | M/s Kang Builders & Developers L1 | bharat contrectors L2 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply, installation, testing and commissioning step down, 11/.433KVA (at no load) transformer, copper wound, outdoor type complete with standard fittings, plateform mounted, HT 11 KV 3 Phase, LT 433 volts, 3 Phase 4 wire with off load tapings on HT side to vary secondary voltage up to ±7.5% with step ± 2.5% including suitable cable entry boxes on LT and bushings on HT side complete in all respects with standard accessories Dy -11 connection of capacity 315 KVA complete all as specified and directed. | 3 | Each Job | 15,45,000 ₹46,35,000 | 16,92,222 ₹50,76,666 | 17,77,777 ₹53,33,331 | 10,50,000 ₹31,50,000 Lowest | 15,00,000 ₹45,00,000 |
| 1.01Salient features of transformer are as under:- (a) Transformer shall be oil immerse, naturally self cooled cooper wound, winding core type, MS radiator cool tank compete with first fill of transformer oil plus 5% spare oil as per IS 335 of 1993. the temperature of oil shall not rise more than 50 degree centigrade and 55 degree centigrade of winding. Transformer shall be painted with 2 coats of epoxy paint as per IS-632. Transformer must have ratings of Energy efficient level-2 & test type level 3. (b) The following standard accessories shall also be provided:- (i) Rating and diagram plate (ii) Earthing terminals 2 Nos (iii) Lifting lugs (iv) Thermometer pocket (v) Air release hole with plug (vi) Tap changer with locking provision (vii) Conservator with oil indicator. (viii) Castors with locking provision (ix) Silica Gel breather complete (x) MS terminal box both on HT and LT site (xi) Oil temperature indicator with maximum & minimum temperature rise indicator. (xii) Plain breathing device which would not permit ingress of rain water and insects. (xiii) Drain-cum-sampling valve (3/4" nominal size thread) preferably steel with plug, (xiv) Oil filling hole (1-1/4" Nominal size thread) with cover (for transformers without conservator) | ||||||||
| 2.00 | Supply, installation, testing and commissioning step down, 11/.433KVA (at no load) transformer, copper wound, outdoor type complete with standard fittings, plateform mounted, HT 11 KV 3 Phase, LT 433 volts, 3 Phase 4 wire with off load tapings on HT side to vary secondary voltage up to ±7.5% with step ± 2.5% including suitable cable entry boxes on LT and bushings on HT side complete in all respects with standard accessories Dy -11 connection of capacity 160 KVA complete all as specified and directed. | 1 | Each Job | 10,60,000 ₹10,60,000 | 8,82,222 ₹8,82,222 | 11,11,111 ₹11,11,111 | 7,00,000 ₹7,00,000 Lowest | 10,00,000 ₹10,00,000 |
| 2.01Salient features of transformer are as under:- (a) Transformer shall be oil immerse, naturally self cooled cooper wound, winding core type, MS radiator cool tank compete with first fill of transformer oil plus 5% spare oil as per IS 335 of 1993. the temperature of oil shall not rise more than 50 degree centigrade and 55 degree centigrade of winding. Transformer shall be painted with 2 coats of epoxy paint as per IS-632. (b) The following standard accessories shall also be provided:- (i) Rating and diagram plate. (ii) Earthing terminals 2 Nos. (iii) Lifting lugs . (iv) Thermometer pocket. (v) Air release hole with plug. (vi) Tap changer with locking provision. (vii) Conservator with oil indicator. (viii) Castors with locking provision. (ix) Silica Gel breather complete. (x) MS terminal box both on HT and LT site. (xi) Oil temperature indicator with maximum & minimum temperature rise indicator. (xii) Plain breathing device which would not permit ingress of rain water and insects. (xiii) Drain-cum-sampling valve (3/4" nominal size thread) preferably steel with plug, (xiv) Oil filling hole (1-1/4" Nominal size thread) with cover (for transformers without conservator) | ||||||||
| 3.00 | Supply, installation, testing and commissioning step down, 11/.433KVA (at no load) transformer, copper wound, outdoor type complete with standard fittings, plateform mounted, HT 11 KV 3 Phase, LT 433 volts, 3 Phase 4 wire with off load tapings on HT side to vary secondary voltage up to ±7.5% with step ± 2.5% including suitable cable entry boxes on LT and bushings on HT side complete in all respects with standard accessories Dy -11 connection of capacity 63 KVA complete all as specified and directed. | 1 | Each Job | 5,60,000 ₹5,60,000 | 6,62,222 ₹6,62,222 | 5,85,055 ₹5,85,055 | 6,00,000 ₹6,00,000 | 5,00,000 ₹5,00,000 Lowest |
| 3.01Salient features of transformer are as under:- (a) Transformer shall be oil immerse, naturally self cooled cooper wound, winding core type, MS radiator cool tank compete with first fill of transformer oil plus 5% spare oil as per IS 335 of 1993. the temperature of oil shall not rise more than 50 degree centigrade and 55 degree centigrade of winding. Transformer shall be painted with 2 coats of epoxy paint as per IS-632. (b) The following standard accessories shall also be provided:- (i) Rating and diagram plate. (ii) Earthing terminals 2 Nos. (iii) Lifting lugs . (iv) Thermometer pocket. (v) Air release hole with plug. (vi) Tap changer with locking provision. (vii) Conservator with oil indicator. (viii) Castors with locking provision. (ix) Silica Gel breather complete. (x) MS terminal box both on HT and LT site. (xi) Oil temperature indicator with maximum & minimum temperature rise indicator. (xii) Plain breathing device which would not permit ingress of rain water and insects. (xiii) Drain-cum-sampling valve (3/4" nominal size thread) preferably steel with plug, (xiv) Oil filling hole (1-1/4" Nominal size thread) with cover (for transformers without conservator) | ||||||||
| 4.00 | Supply, installation, testing and commissioning step down, 11/.433KVA (at no load) transformer, copper wound, outdoor type complete with standard fittings, plateform mounted, HT 11 KV 3 Phase, LT 433 volts, 3 Phase 4 wire with off load tapings on HT side to vary secondary voltage up to ±7.5% with step ± 2.5% including suitable cable entry boxes on LT and bushings on HT side complete in all respects with standard accessories Dy -11 connection of capacity 250 KVA complete all as specified and directed. | 1 | Each Job | 11,80,000 ₹11,80,000 | 13,92,222 ₹13,92,222 | 14,14,141 ₹14,14,141 | 9,50,000 ₹9,50,000 Lowest | 12,00,000 ₹12,00,000 |
| 4.01Salient features of transformer are as under:- (a) Transformer shall be oil immerse, naturally self cooled cooper wound, winding core type, MS radiator cool tank compete with first fill of transformer oil plus 5% spare oil as per IS 335 of 1993. the temperature of oil shall not rise more than 50 degree centigrade and 55 degree centigrade of winding. Transformer shall be painted with 2 coats of epoxy paint as per IS-632. (b) The following standard accessories shall also be provided:- (i) Rating and diagram plate (ii) Earthing terminals 2 Nos (iii) Lifting lugs (iv) Thermometer pocket (v) Air release hole with plug (vi) Tap changer with locking provision (vii) Conservator with oil indicator. (viii) Castors with locking provision (ix) Silica Gel breather complete (x) MS terminal box both on HT and LT site (xi) Oil temperature indicator with maximum & minimum temperature rise indicator. (xii) Plain breathing device which would not permit ingress of rain water and insects. (xiii) Drain-cum-sampling valve (3/4" nominal size thread) preferably steel with plug, (xiv) Oil filling hole (1-1/4" Nominal size thread) with cover (for transformers without conservator) | ||||||||
| 5.00All Transformers to be supplied in this BOQ must be atleast Energy Efficient Level Rating-2. Deduction for schedule of credit(Sch A Part-ii) to be made of Rs 0.00 from the total quoted amount of BOQ while accepting the bid. Details of schedule of credit is given in tender documents". | ||||||||
Tender Value
₹50.5 L
EMD Value
₹1.0 L
Closing Date
20 Sept 2025, 5:00 pmClosed
Anurag Anand DCWE
Anurag Anand (DCWE) Contract
SPL REPAIR AND REPLACEMENT OF TRANSFORMER AGAINST BER UNDER GE N AKHNOOR
2025_MES_726044_1
CWE/JA-02/2025-26
Open Tender
Electrical and Maintenance Works
Works
180 days
HQ 135 Wks Engrs (Akhnoor)
9 documents required · 9 mandatory
₹1,000
Yes
GE NORTH AKHNOOR
₹1.0 L
Yes
14 Oct 2025
18 Aug 2025
27 Sept 2025
18 Aug 2025
20 Sept 2025
18 Aug 2025
18 Aug 2025 - 18 Aug 2025
Amount
Supply, installation, testing and commissioning step down, 11/.433KVA (at no load) transformer, copper wound, outdoor type complete with standard fittings, plateform mounted, HT 11 KV 3 Phase, LT 433 volts, 3 Phase 4 wire with off load tapings on HT side to vary secondary voltage up to ±7.5% with step ± 2.5% including suitable cable entry boxes on LT and bushings on HT side complete in all respects with standard accessories Dy -11 connection of capacity 315 KVA complete all as specified and directed.
Salient features of transformer are as under:- (a) Transformer shall be oil immerse, naturally self cooled cooper wound, winding core type, MS radiator cool tank compete with first fill of transformer oil plus 5% spare oil as per IS 335 of 1993. the temperature of oil shall not rise more than 50 degree centigrade and 55 degree centigrade of winding. Transformer shall be painted with 2 coats of epoxy paint as per IS-632. Transformer must have ratings of Energy efficient level-2 & test type level 3. (b) The following standard accessories shall also be provided:- (i) Rating and diagram plate (ii) Earthing terminals 2 Nos (iii) Lifting lugs (iv) Thermometer pocket (v) Air release hole with plug (vi) Tap changer with locking provision (vii) Conservator with oil indicator. (viii) Castors with locking provision (ix) Silica Gel breather complete (x) MS terminal box both on HT and LT site (xi) Oil temperature indicator with maximum & minimum temperature rise indicator. (xii) Plain breathing device which would not permit ingress of rain water and insects. (xiii) Drain-cum-sampling valve (3/4" nominal size thread) preferably steel with plug, (xiv) Oil filling hole (1-1/4" Nominal size thread) with cover (for transformers without conservator)
Supply, installation, testing and commissioning step down, 11/.433KVA (at no load) transformer, copper wound, outdoor type complete with standard fittings, plateform mounted, HT 11 KV 3 Phase, LT 433 volts, 3 Phase 4 wire with off load tapings on HT side to vary secondary voltage up to ±7.5% with step ± 2.5% including suitable cable entry boxes on LT and bushings on HT side complete in all respects with standard accessories Dy -11 connection of capacity 160 KVA complete all as specified and directed.
Salient features of transformer are as under:- (a) Transformer shall be oil immerse, naturally self cooled cooper wound, winding core type, MS radiator cool tank compete with first fill of transformer oil plus 5% spare oil as per IS 335 of 1993. the temperature of oil shall not rise more than 50 degree centigrade and 55 degree centigrade of winding. Transformer shall be painted with 2 coats of epoxy paint as per IS-632. (b) The following standard accessories shall also be provided:- (i) Rating and diagram plate. (ii) Earthing terminals 2 Nos. (iii) Lifting lugs . (iv) Thermometer pocket. (v) Air release hole with plug. (vi) Tap changer with locking provision. (vii) Conservator with oil indicator. (viii) Castors with locking provision. (ix) Silica Gel breather complete. (x) MS terminal box both on HT and LT site. (xi) Oil temperature indicator with maximum & minimum temperature rise indicator. (xii) Plain breathing device which would not permit ingress of rain water and insects. (xiii) Drain-cum-sampling valve (3/4" nominal size thread) preferably steel with plug, (xiv) Oil filling hole (1-1/4" Nominal size thread) with cover (for transformers without conservator)
Supply, installation, testing and commissioning step down, 11/.433KVA (at no load) transformer, copper wound, outdoor type complete with standard fittings, plateform mounted, HT 11 KV 3 Phase, LT 433 volts, 3 Phase 4 wire with off load tapings on HT side to vary secondary voltage up to ±7.5% with step ± 2.5% including suitable cable entry boxes on LT and bushings on HT side complete in all respects with standard accessories Dy -11 connection of capacity 63 KVA complete all as specified and directed.
Salient features of transformer are as under:- (a) Transformer shall be oil immerse, naturally self cooled cooper wound, winding core type, MS radiator cool tank compete with first fill of transformer oil plus 5% spare oil as per IS 335 of 1993. the temperature of oil shall not rise more than 50 degree centigrade and 55 degree centigrade of winding. Transformer shall be painted with 2 coats of epoxy paint as per IS-632. (b) The following standard accessories shall also be provided:- (i) Rating and diagram plate. (ii) Earthing terminals 2 Nos. (iii) Lifting lugs . (iv) Thermometer pocket. (v) Air release hole with plug. (vi) Tap changer with locking provision. (vii) Conservator with oil indicator. (viii) Castors with locking provision. (ix) Silica Gel breather complete. (x) MS terminal box both on HT and LT site. (xi) Oil temperature indicator with maximum & minimum temperature rise indicator. (xii) Plain breathing device which would not permit ingress of rain water and insects. (xiii) Drain-cum-sampling valve (3/4" nominal size thread) preferably steel with plug, (xiv) Oil filling hole (1-1/4" Nominal size thread) with cover (for transformers without conservator)
Supply, installation, testing and commissioning step down, 11/.433KVA (at no load) transformer, copper wound, outdoor type complete with standard fittings, plateform mounted, HT 11 KV 3 Phase, LT 433 volts, 3 Phase 4 wire with off load tapings on HT side to vary secondary voltage up to ±7.5% with step ± 2.5% including suitable cable entry boxes on LT and bushings on HT side complete in all respects with standard accessories Dy -11 connection of capacity 250 KVA complete all as specified and directed.
Salient features of transformer are as under:- (a) Transformer shall be oil immerse, naturally self cooled cooper wound, winding core type, MS radiator cool tank compete with first fill of transformer oil plus 5% spare oil as per IS 335 of 1993. the temperature of oil shall not rise more than 50 degree centigrade and 55 degree centigrade of winding. Transformer shall be painted with 2 coats of epoxy paint as per IS-632. (b) The following standard accessories shall also be provided:- (i) Rating and diagram plate (ii) Earthing terminals 2 Nos (iii) Lifting lugs (iv) Thermometer pocket (v) Air release hole with plug (vi) Tap changer with locking provision (vii) Conservator with oil indicator. (viii) Castors with locking provision (ix) Silica Gel breather complete (x) MS terminal box both on HT and LT site (xi) Oil temperature indicator with maximum & minimum temperature rise indicator. (xii) Plain breathing device which would not permit ingress of rain water and insects. (xiii) Drain-cum-sampling valve (3/4" nominal size thread) preferably steel with plug, (xiv) Oil filling hole (1-1/4" Nominal size thread) with cover (for transformers without conservator)
All Transformers to be supplied in this BOQ must be atleast Energy Efficient Level Rating-2. Deduction for schedule of credit(Sch A Part-ii) to be made of Rs 0.00 from the total quoted amount of BOQ while accepting the bid. Details of schedule of credit is given in tender documents".
bharat contrectors (BID ID -3430966)
SHSS ASSOCIATES (BID ID -3431114)
M/S JIWAN SINGH (BID ID -3430628)
Usha Engineering Co. (BID ID -3430387)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .