| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹77.8 LAccepted-AOC 1 128 A SECOND FLOOR MOHAMMADPUR NEAR BHIKAJCAMA PLACE NEW DELHI 110066 | NEW DELHI | NEW DELHI | DELHI | 110066 | L1 | Accepted-AOC 1st lowest | |
| 2 | L2₹79.2 L+₹99,471 (1.27%)Rejected-Finance | L2 | Rejected-Finance 2nd Lowest | |
| 3 | L3₹84.1 L+₹5.9 L (7.56%)Rejected-Finance COLABA MUMBAI | L3 | Rejected-Finance 3rd Lowest | |
| 4 | Rejected-Technical | - | Rejected-Technical Being two class below and not enlisted in appropriate category |
Tender Value
Refer Docs
EMD Value
₹1.5 L
Closing Date
10 Oct 2022, 6:00 pmClosed
CWE Mhow
HQ CWE Mhow Cantt Mhow 453441
COMPREHENSIVE MAINT OF LIFTS BY OEM INSTALLED AT MAP ACCN AT SOME ENCLAVE AND GOSWAMI ENCLAVE IN GE AWC GANESH ENCLAVE MAP KODARIA IN GE MCTE AND ANNUAL MAINT SERVICING OF LIFTS INCLUDING CONNECTED WORK AT VARIOUS LOCATIONS IN MIS UNDER GE MCTE MHOW
2022_MES_539136_2
CWE(MHOW)/06(T) OF 2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
HQ CWE Mhow
Please refer tender documents
8 documents required · 8 mandatory
₹1,000
GE MCTE Mhow
₹1.5 L
24 Nov 2022
16 Sept 2022
12 Oct 2022
16 Sept 2022
10 Oct 2022
27 Sept 2022
Amount
Comprehensive, preventive and periodical maintenance as per of 8 Passenger lifts capacity 544Kg & 13 Passenger Lifts Capacity 884KG, are installed for (G+6 floor /G+5 Floor ).Make : JOHNSON with travelling speed of 1m/s installed at Location as mentioned below, in reliable, safe and efficient manner using latest techniques and expertise consultancy (by manufacturer Johnson). Regularly examining lubricating and adjusting the mechanical and electrical driving equipment, governer sleeve, shaft assembly, bearing/contact/governer jaws car and hall mechenical buttons, car and hall position indicators, car direction indicators and all other car and landing signal/fixtures, deflectors, car and counter weight guid rails and buffers etc, including replacement of defective/spares parts as coverd under scope of MOU (Platinum) as requied the following :-
For 8 Passenger Lift (544Kg, installed for G+6 floor) Location :- (a) (For GE(M) Inf School Mhow) -09 Nos lift (HDE Enclave) (b) (For GE(MCTE) Mhow) -13Nos lift (Ganesh Enclave (DU's MAP Kodaria) (SM - 281 to 294) (c) (For GE(AWC) Mhow) -02Nos lift (JCO MAP Accn Vindhya vihar ) (d) (For GE(AWC) Mhow) -08Nos lift (JCO & OR MAP Accn AB Road )
For 13 Passenger Lift (884Kg, installed for G+6 floor) (a) (For GE(M) Inf School Mhow) -09 Nos lift- (HDE Enclave) (b) (For GE(MCTE) Mhow) -14Nos lift - (Ganesh Enclave (DU's MAP Kodaria) (SM - 281 to 294) (c) (For GE(AWC) Mhow) -02Nos lift - (JCO MAP Accn Vindhya vihar ) (d) (For GE(AWC) Mhow) -08Nos lift - (JCO & OR MAP Accn AB Road )
For 13 Passenger Lift (884Kg, installed for G+5 floor) (For GE(AWC) Mhow) -03Nos lift - (OFFRs MAP Accn Vindhya vihar )
Notes for item No 01:- (a) The comprehencive/preventive periodical maint incuding monthly inspection testing as per service manual. The inspection/test report will be submitted to Engr-in-Charge. (b) The AMC shall be in force immediately after issue of Work Order No 1 commencement date. (c) All the compalints are required to be rectify as per scope of work specified in particular specification. (d) The cost of transportation (to and from) and other necessary equipment shall be arranged/brought by contractor by complite the job and no extra cost shall to be paid to the contractor in the effect. (e) The contractor shall display or his trademen's/employees mob/contact no in each lift car and at lift lobby and updated from time to time. (f) Contractor shall be submit the MOU (Platinium) between the contractor and OEM or authorized service dealer of OEM and same shall be submitted in original and uploaded along with tender documents. (g) Service Engineer will visit quartely for the maintence and checks all mechanism along with greasing of complete mechanism in quarterly basis. (h) All complaints will be attended within 04 hrs from the receipt of complaint, if the contractor fails to attend complaint within 04 hrs from the time of receipt of complaint a panel recovery of Rs 5000 per complaint per hrs for the next 4 hrs and further Rs 10000 per complaint per hrs till the complaint is resolved shall be recovered from the contractor due. The deceision of GE in there regards shall be final and binding. (j) Display Mobile no of authorised agents of OEM in each lift car and lift lobbs and upto date from time to time. (k) Old material will be property of department.
S&F in replacement of Battery 12 volts, 7.2 AH, dry type for ARD of 8 Passenger lift as directed by Eng-in-Charge. (Make : Exide/Microtec/Amron) , (MCTE-26) (MIS-36)
S&F in replacement of Battery 12 volts, 18 AH, dry type for ARD of 13 Passenger lift as directed by Eng-in-Charge. (Make : Exide/Microtec/Amron), (MCTE-22)
S&F in replacement of Battery 12 volts, 18 AH, dry type for ARD of 08 Passenger lift as directed by Eng-in-Charge. (Make : Exide/Microtec/Amron), (MIS-36)
S&F in replacement of Battery 12 volts, 2.5 AH, dry type. (Make : Exide/Microtec/Amron) ,(MIS-18)
S&F in replacement of Cross Flow Fan, 200mm sweep metalic body as per existing size and including dismantling of old one. (Make : Bajaj/CG/Havells/Anchor/Usha/Khaitan), (MIS-10) (MCTE-08)
S&F in replacement of LED panel light fittings 5 watts with reflector including dismantling of old one as directed by Engr-in-Charge. (Make : Havells/Philips/Wipro/Crompton). (MIS-50) (MCTE-51)
AMIT ASSOCIATES
Monarch Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .