Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Rejected-Technical | Rejected-Technical Pl refer TR |
| 5 | Rejected-Technical 119 120 MUNSHI VILLA 119 120 SHRI VIHAR DURGAPURA JAIPUR RAJASTHAN 302018 | JAIPUR | RAJASTHAN | 302018 | Rejected-Technical Pl refer TR |
Tender Value
Refer Docs
EMD Value
₹23.0 L
Closing Date
10 Feb 2025, 11:00 amClosed
Sanjeeb Barman 9435558715
Numaligarh Refinery Limited
STATION WORKS FOR NUMALIGARH REFINERY TO DABIDUBI VILLAGE CROSS COUNTRY PIPELINE PROJECT
2024_NRL_841982_1
OC10000517/SNJ
Open Tender
Miscellaneous Works
365 days
Numaligarh Refinery Limited
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
₹23.0 L
Yes
As per tender
11 Jun 2025
2 Jan 2025
11 Feb 2025
2 Jan 2025
10 Feb 2025
2 Jan 2025
16 Jan 2025
Amount
PIPING
Piping Works at Dispatch & Receipt Stations
Fabrication, Erection, Installation and Testing of Piping: Receiving and taking over of all Owner supplied materials from Owner's designated place(s) of issue, transportation including loading, unloading, handling from Owner's designated place(s) of issue to Contractor's own stock yard(s)/ work site(s)/ work shop(s) including arranging all necessary intermediate storage area(s) thereof, as required; supply of all materials (except those specified subsequently in SOR), equipment, consumables as defined in Contractor's scope of supply and their transportation to the work site(s); performing all above ground/buried piping fabrication works including cutting, edge preparation (inclusive of grinding the edges of pipes, fittings, flanges etc. to match with thematching edges of uneven/ different thickness wherever required), fit up, bending, pre-heating wherever required, welding, threading etc.; erection of pipes of all types and thickness over sleepers, overhead on racks and at all elevations; hook-up with equipment nozzles; installation of all type of valves up to size of 1.5" NB, all types of inline and online instruments such as pressure/thermal safety valves (other than those covered separately), fittings of all sizes i.e. flow tees, insulating joints, LR bends, elbows, pig signallers, reducers, tees, 'o' lets, flanges, blind flanges, spectacle blinds, tappings for pressure gauges, thermowells, hoses and hose couplings of all sizes, if applicable, sample connections, flame arrestors as applicable, vents and drains required for process and hydrotesting purposes etc. including fixing of all types of gaskets , bolts, studs and nuts of all sizes;, carrying out non-destructive testing (excluding radiography covered subsequently in SOR) such as magnetic particle/ liquid penetration etc. as required; hook-up with existing piping/pipeline installed by others as per drawings wherever required; cleaning and flushing by water/ compressed air, carrying out hydrostatic test, pneumatic test, valve functional test and any other type of testing as specified, depressurising, dewatering, drying by compressed air if applicable; cutting/ rebeveling (as required), precommissioning and providing commissioning assistance to Commissioning Contractor/Agency for process piping and commissioning of non-process piping if applicable; clean-up and restoration of site, preparation of as built drawings, documents and project records; transportation of surplus free issue materials to Owner's designated place(s); completing all works in all respects as per the AFC drawings, specifications, standards and other provisions of Contract and instruction of Engineer-in-Charge. Note :- a.) All items fittings, flanges, valves, pipes below 2" shall be supplied & installed by the contractor under this item, Contractor to quote accordingly. b.) All bolts, nuts, gaskets of all size shall be supplied & installed by the contractor under this item, Contractor to quote accordingly. c.) Contractor works includes all work including tie in with existing terminal inside Dispatch & Receipt Stations and with pipeline (Refer scope demarcation drawing)
Installation of Above Ground Carbon Steel Process Piping (Including all Flanges & Fittings) as per details given below:
Size- 8", Sch - 6.4, Material - API 5L X-42, PSL2, ASME B36.10, Seamless
Size - 8", Sch - STD , Material - ASTM A106 GR.B, BE, ASME B36.10, Seamless
Size - 6", Sch - STD , Material - ASTM A106 GR.B, BE, ASME B36.10, Seamless
Size - 4", Sch - STD , Material - ASTM A106 GR.B, BE, ASME B36.10, Seamless
Size - 2", Sch - STD , Material - ASTM A106 GR.B, BE, ASME B36.10, Seamless
Installation of Under Ground Carbon Steel Process Piping (Including all Flanges & fittings) Including Trenching and Back filling all complete as per details given below: NOTE:-INSTALLATION WORKS INCLUDING TRENCHING, COATING OF PIPE & FITTINGS WITH MIN. 1000 MICRON SOLID EPOXY (i.e POWERCRETE R95) & BACKFILLING ALL COMPLETE. (BIDDER TO QUOTE ACCORDINGLY).
Size- 8", Sch - 6.4, BW, API 5L X-42, PSL2, ASME B36.10, Seamless
Size - 4", Sch - STD, Material - ASTM A106 GR.B, BE, ASME B36.10, Seamless
Size - 4", Sch - STD, Material - ASTM A333 GR.6, BE, ASME B36.10, Seamless
Size - 2", Sch - STD , Material - ASTM A106 GR.B, BE, ASME B36.10, Seamless
Installation of Above Ground Low Temperature Carbon Steel Process Piping (Including all Flanges & fittings) as per details given below:
Size - 6", Sch - STD, Material - ASTM A333 GR.6, BE, ASME B36.10, Seamless
Size - 4", Sch - STD, Material - ASTM A333 GR.6, BE, ASME B36.10, Seamless
Size - 2", Sch - XS, Material - ASTM A333 GR.6, BE, ASME B36.10, Seamless
Size - 2", Sch - STD, Material - ASTM A333 GR.6, BE, ASME B36.10, Seamless
Installation of Under Ground Low Temperature Carbon Steel Process Piping (Including all Flanges & fittings)Including Trenching and Back filling all complete as per details given below: NOTE:-INSTALLATION WORKS INCLUDING TRENCHING, COATING OF PIPE & FITTINGS WITH MIN. 1000 MICRON SOLID EPOXY (i.e POWERCRETE R95) & BACKFILLING ALL COMPLETE. (BIDDER TO QUOTE ACCORDINGLY).
Size - 4", Sch - STD, Material - ASTM A333 GR.6, BE, ASME B36.10, Seamless
Size - 2", Sch - XS, Material - ASTM A333 GR.6, BE, ASME B36.10, Seamless
Installation of Above Ground Flow Tee as per details given below:
Size 8"X8", ASTM A234 Gr. WPB, Thk. 6.4, 300#. Run Pipe - 8", 30HCML, API 5L X-42, PSL2, Thk. 6.4, 300#. Branch Pipe - 8", B1A, ASTM A106 Gr.B, Sch. STD, 300#.
Installation of Under Ground Flow Tee as per details given below:
Size 8"X4", ASTM A234 Gr. WPB, Thk. 6.4, 300#. Run Pipe - 8" 30HCML, API 5L X-42, PSL2, Thk. 6.4, 300#. Branch Pipe - 4", B1A, ASTM A106 Gr.B, Sch. STD, 300#.
Size 8"X4", ASTM A234 Gr. WPB, Thk. 6.4, 300#. Run Pipe - 8", 30HCML, API 5L X-42, PSL2, Thk. 6.4, 300#. Branch Pipe - 4", B4A, ASTM A333 Gr.6, Sch. STD, 300#.
Installation of Insulating Joint as per details given below:
Size 2", B1A, 300#, IJ Material- ASTM A105N
Size 2", B4A, 300#, IJ Material-ASTM A350 Gr. LF2
Size 4", B4A, 300#, IJ Material-ASTM A350 Gr. LF2
Installation of Valves / Scraper Launcher / Receiver at Dispatch & Receipt Stations
Receiving and taking over of all Owner supplied materials, equipment from Owner's designated place(s) of issue, transportation including loading, unloading, handling from Owner's designated place(s) of issue to Contractor's own stock yard(s)/ work site(s)/ work shop(s) including arranging all necessary intermediate storage area(s) thereof, as required; supply of all materials, equipment, consumables as defined in Contractor's scope of supply and its transportation to the worksite(s);installation of valves, scraper launcher, including fixing of gaskets, bolts, studs, nuts wherever required, levelling, aligning, installation and assembly of accessories including accessories for actuators including making electrical connections for such actuators, if any, by bolting/threading or welding of pipes at all elevations, testing, completing all works in all respects as per drawings, specification, other provisions of Contract and directions of the Engineer-in-Charge. Note : Work shall be carried out by Contractor as per battery limit Drawing (Scope Demarcated P&ID), the hook up shall be carried out by the Contractor who has completed the work at last.
Installation of Scraper Launcher / Receiver along with Pig Handling system as per details given below:
Barrel Size - 14 INCH, Neck Size - 8 INCH, Rating -300#
Installation of Above Ground Flanged Valves (Ball / Check / Globe) as per details given below:
Size - 8", Rating - 300#
Size - 4", Rating - 150#
Size - 4", Rating - 300#
Size - 2", Rating - 300#
Size - 2", Rating - 150#
Installation of Above Ground Butt Welded Ends Valves (Ball / Check / Globe) as per details given below:
Size - 4", Rating - 300#
Size - 2", Rating - 300#
Installation of Under Ground Butt Welded Ends Valves (Ball / Check / Globe) as per details given below:
Size - 4", Rating - 300#
Size - 2", Rating - 300#
Installation, Calibration and Commissioning of Above Ground Flanged Ends MOV/UV Ball Valves and MOV/UV Actuator as per Standard Specification, Data Sheets, P & IDs as per details given below:
MOV Size - 8", Rating - 300#
MOV Size - 4", Rating - 300#
UV Size - 8", Rating - 300#
Installation, Calibration and Commissioning of Above Ground Butt Weld Ends MOV/UV Ball Valves and MOV/UV Actuator as per Standard Specification, Data Sheets, P & IDs as per details given below:
MOV Size - 8", Rating - 300#
UV Size - 8", Rating - 300#
Installation, Calibration and Commissioning of Under Ground Butt Weld Ends MOV/UV Ball Valves and MOV/UV Actuator as per Standard Specification, Data Sheets, P & IDs as per details given below:
MOV Size - 8", Rating - 300#
UV Size - 8", Rating - 300#
Installation of PSV Valves as per details given below:
Size- 1.5" (Inlet,600#) X 2"(Outlet,150#) Note- PSVs inlet & outlet size are under hold & shall be finalized post receipt of vendor data.
Size- 1" (Inlet,600#) X 2"(Outlet,150#) Note- PSVs inlet & outlet size are under hold & shall be finalized post receipt of vendor data.
Size- 1" (Inlet,300#) X 2"(Outlet,150#) Note- PSVs inlet & outlet size are under hold & shall be finalized post receipt of vendor data.
Installation of TSV Valves as per details given below:
Size- 1" (Inlet,600#) X 2"(Outlet,150#) Note- TSVs inlet & outlet size are under hold & shall be finalized post receipt of vendor data.
Size- 1" (Inlet,300#) X 2"(Outlet,150#) Note- TSVs inlet & outlet size are under hold & shall be finalized post receipt of vendor data.
Installation of Check Meter (Flow Meter) as per details given below:
Size- 6"*, B1A, Rating - 600# Note- inlet & outlet size are under hold & shall be finalized post receipt of vendor data.
Supply Including Procurement and Transportation to Work Site (S) / Work Shop (S) Including Loading, Unloading and Handling for the following Materials to be supplied by Contractor as per requirement of PMS, Specifications, Data Sheets, Standards, Instruction of Owner / Engineer-in charge and other provisions of contract.
Supply of Scraper Launcher / Receiver along with Pig Handling System as per Material Requisition and attached Data Sheet with Station Work Tender.
Barrel Size - 14 INCH, Neck Size - 8 INCH, Rating -300#
Supply of Above Ground Flow Tee as per Material Requisition and attached Data Sheet with Station Work Tender.
Size 8"X8", ASTM A234 Gr. WPB, Thk. 6.4 mm, 300#. Run Pipe 8", 30HCML, API 5L X-42, PSL2, Thk. 6.4 mm, 300#. Branch Pipe 8", B1A, ASTM A106 Gr.B, Sch. STD, 300#.
Supply of Under Ground Flow Tee as per Material Requisition and attached Data Sheet with Station Work Tender.
Size 8"X4", ASTM A234 Gr. WPB, Thk. 6.4 mm, 300#. Run Pipe 8" 30HCML, API 5L X-42, PSL2, Thk. 6.4 mm, 300#. Branch Pipe 4", B1A, ASTM A106 Gr.B, Sch. STD, 300#.
Size 8"X4", ASTM A234 Gr. WPB, Thk. 6.4 mm, 300#. Run Pipe 8", 30HCML, API 5L X-42, PSL2, Thk. 6.4 mm, 300#. Branch Pipe 4", B4A, ASTM A333 Gr.6, Sch. STD, 300#.
Supply of Insulating Joint as per Material Requisition and attached Data Sheet with Station Work Tender.
Size 2", B1A, 300#, IJ Material- ASTM A105N
Size 2", B4A, 300#, IJ Material-ASTM A350 Gr. LF2
Size 4", B4A, 300#, IJ Material-ASTM A350 Gr. LF2
Valves
Supply of Above Ground Flanged Ball Valves as per attached Data Sheet with Station Work Tender, as per details given below:
Size - 2", B1A, Body-ASTM A105N / ASTM A216 Gr. WCB, FLGD, ASME B16.5, RF / 125AARH, API 6D / API 608, Full Body Welded, Tight Shut Off
Size - 2", B1A, Body-ASTM A105N / ASTM A216 Gr. WCB, FLGD, ASME B16.5, RF / 125AARH, API 6D / API 608, Full Bore
Size - 2", B1A, Body-ASTM A105N / ASTM A216 Gr. WCB, FLGD, ASME B16.5, RF / 125AARH, API 6D / API 608
Size - 2", B1A, Body-ASTM A105N / ASTM A216 Gr. WCB, FLGD, ASME B16.5, RF / 125AARH, API 6D / API 608, Tight Shut Off
Size - 2", B1A, Body-ASTM A105N / ASTM A216 Gr. WCB, FLGD, ASME B16.5, RF / 125AARH, API 6D / API 608, Locking Arrangement
Size - 2", B4A, Body-ASTM A350 Gr. LF2 / ASTM A352 Gr.LCB, FLGD, ASME B16.5, RF / 125AARH, API 6D / API 608, Full Bore, Locking Arrangement
Size - 2", B4A, Body-ASTM A350 Gr. LF2 / ASTM A352 Gr.LCB, FLGD, ASME B16.5, RF / 125AARH, API 6D / API 608, Full Bore, Tight Shut Off
Size - 2", B4A, Body-ASTM A350 Gr. LF2 / ASTM A352 Gr.LCB, FLGD, ASME B16.5, RF / 125AARH, API 6D / API 608, Locking Arrangement
Size - 2", B4A, Body-ASTM A350 Gr. LF2 / ASTM A352 Gr.LCB, FLGD, ASME B16.5, RF / 125AARH, API 6D / API 608, Tight Shut Off
Size - 2", B4A, Body-ASTM A350 Gr. LF2 / ASTM A352 Gr.LCB, FLGD, ASME B16.5, RF / 125AARH, API 6D / API 608, Full Bore
Size - 2", B4A, Body-ASTM A350 Gr. LF2 / ASTM A352 Gr.LCB, FLGD, ASME B16.5, RF / 125AARH, API 6D / API 608
Size - 2", A4A, Body-ASTM A350 Gr. LF2 / ASTM A352 Gr.LCB, FLGD, ASME B16.5, RF / 125AARH, API 6D / API 608
Size - 2", A4A, Body-ASTM A350 Gr. LF2 / ASTM A352 Gr.LCB, FLGD, ASME B16.5, RF / 125AARH, API 6D / API 608, Full Bore, Locking Arrangement
Size - 2", A4A, Body-ASTM A350 Gr. LF2 / ASTM A352 Gr.LCB, FLGD, ASME B16.5, RF / 125AARH, API 6D / API 608, Locking Arrangement
Supply of Above Ground Flanged Globe Valves as per attached Data Sheet with Station Work Tender, as per details given below:
Size - 2", B1A, Body-ASTM A216 Gr. WCB, FLGD, ASME B16.5, RF / 125AARH, API 623, Tight Shut Off
Size - 2", B1A, Body-ASTM A216 Gr. WCB, FLGD, ASME B16.5, RF / 125AARH, API 623
Size - 2", B4A, Body-ASTM A352 Gr. LCB, FLGD, ASME B16.5, RF / 125AARH, API 623, Full Port, Locking Arrangement
Size - 2", B4A, Body-ASTM A352 Gr. LCB, FLGD, ASME B16.5, RF / 125AARH, API 623, Locking Arrangement
Size - 2", B4A, Body-ASTM A352 Gr. LCB, FLGD, ASME B16.5, RF / 125AARH, API 623
Supply of Above Ground Flanged Check Valves as per attached Data Sheet with Station Work Tender, as per details given below:
Size - 2", B1A, Body-ASTM A216 Gr. WCB, FLGD, ASME B16.5, RF / 125AARH, API 6D / API 594
Size - 2", A4A, Body-ASTM A352 Gr. LCB, FLGD, ASME B16.5, RF / 125AARH, API 6D / API 594
Supply of Above Ground Butt Welded Ball Valves as per attached Data Sheet with Station Work Tender, as per details given below:
Size - 2", B1A, BW, Body-ASTM A105N / ASTM A216 Gr. WCB, API 6D / API 608, ASME B16.25, Full Body Welded, Full Bore
Size - 2", B1A, BW, Body-ASTM A105N / ASTM A216 Gr. WCB, API 6D / API 608, ASME B16.25, Full Body Welded
Size - 2", B1A, BW, Body-ASTM A105N / ASTM A216 Gr. WCB, API 6D / API 608, ASME B16.25, Full Body Welded, Full Bore, Locking Arrangement
Size - 2", B1A, BW, Body-ASTM A105N / ASTM A216 Gr. WCB, API 6D / API 608, ASME B16.25, Full Body Welded
Size - 2", B4A, BW, Body-ASTM A350 Gr. LF2 / ASTM A352 Gr.LCB, API 6D / API 608, ASME B16.25, Full Body Welded, Full Bore, Locking Arrangement
Size - 2", B4A, BW, Body-ASTM A350 Gr. LF2 / ASTM A352 Gr.LCB, API 6D / API 608, ASME B16.25, Full Body Welded
Size - 2", B4A, BW, Body-ASTM A350 Gr. LF2 / ASTM A352 Gr.LCB, API 6D / API 608, ASME B16.25, Full Body Welded
Supply of Above Ground Butt Welded Globe Valves as per attached Data Sheet with Station Work Tender, as per details given below:
Size - 2", B1A, BW, Body-ASTM A216 Gr. WCB, Trim-13% CR, 300#, API 623, ASME B16.25, Full Body Welded
Size - 2", B1A, BW, Body-ASTM A216 Gr. WCB, Trim-13% CR, 300#, API 623, ASME B16.25, Full Body Welded, Locking Arrangement
Supply of Under Ground Butt Welded Ball Valves as per attached Data Sheet with Station Work Tender, as per details given below:
Size - 2", B4A, BW, Body-ASTM A350 Gr. LF2 / ASTM A352 Gr.LCB, API 6D / API 608, ASME B16.25, Full Body Welded, With Extended Stem
Pipes
Supply of Carbon Steel Process Pipe as per details given below:
Size - 8", B1A, Sch - STD, Material - ASTM A106 GR.B, BE, ASME B36.10, Seamless
Size - 6"*, B1A, Sch - STD, Material - ASTM A106 GR.B, BE, ASME B36.10, Seamless
Size - 6", A4A, Sch - STD , Material - ASTM A333 GR.6, BE, ASME B36.10, Seamless
Size - 4", B1A, Sch - STD, Material - ASTM A106 GR.B, BE, ASME B36.10, Seamless
Size - 4", B4A, Sch - STD, Material - ASTM A333 GR.6, BE, ASME B36.10, Seamless
Size - 4", A4A, Sch - STD, Material - ASTM A333 GR.6, BE, ASME B36.10, Seamless
Size - 2", B1A, Sch - STD, Material - ASTM A106 GR.B, BE, ASME B36.10, Seamless
Size - 2", B4A, Sch - XS, Material - ASTM A333 GR.6, BE, ASME B36.10, Seamless
Size - 2", A4A, Sch - STD, Material - ASTM A333 GR.6, BE, ASME B36.10, Seamless
Flanges & Fittings
Supply of Weld Neck Raised Face Flanges as per details given below:
Size- 8", 30HCML, 300#, Thk. - 6.4, WNRF, ASTM A105, RF/125AARH, ASME B16.5
Size- 8", B1A, 300#, Sch - STD, WNRF, ASTM A105N, RF/125AARH, ASME B16.5
Size- 8", B1A, 300#, Sch - STD WNRF, ASTM A105N, RF/125AARH, ASME B16.5, with JS Hole
Size- 4", B1A, 300#, Sch - STD, WNRF, ASTM A105N, RF/125AARH, ASME B16.5
Size- 4", B1A, 300#, Sch - STD, WNRF, ASTM A105N, RF/125AARH, ASME B16.5, with JS Hole
Size- 2", B1A, 300#, Sch - STD, WNRF, ASTM A105N, RF/125AARH, ASME B16.5
Size- 2", B1A, 300#, Sch - STD, WNRF, ASTM A105N, RF/125AARH, ASME B16.5, with JS Hole
Size- 6"*, B1A, 300#, Sch - STD, WNRF, ASTM A105N, RF/125AARH, ASME B16.5 Note:-Flange are under hold and shall be finalized post receipt of vendor data.
Size- 4", B4A, 300#, Sch - STD, WNRF, ASTM A350 GR.LF2, RF/125AARH, ASME B16.5
Size- 4", A4A, 300#, Sch - STD, WNRF, ASTM A350 GR.LF2, RF/125AARH, ASME B16.5, Off Spec. Flange
Size- 2", B4A, 300#, Sch - XS, WNRF, ASTM A350 GR.LF2, RF/125AARH, ASME B16.5
Size- 2", B4A, 300#, Sch - XS, WNRF, ASTM A350 GR.LF2, RF/125AARH, ASME B16.5, with JS Hole
Size- 6", A4A, 150#, Sch - STD, WNRF, ASTM A350 GR.LF2, RF/125AARH, ASME B16.5
Size- 4", A4A, 150#, Sch - STD, WNRF, ASTM A350 GR.LF2, RF/125AARH, ASME B16.5
Size- 2", A4A, 300#, Sch - STD, WNRF, ASTM A350 GR.LF2, RF/125AARH, ASME B16.5, Off Spec. Flange
Size- 2", A4A, 150#, Sch - STD, WNRF, ASTM A350 GR.LF2, RF/125AARH, ASME B16.5
Supply of Raised Face Blind Flanges as per details given below:
Size- 8", B1A, 300#, ASTM A105N, RF/125AARH, ASME B16.5
Size- 2", B1A, 300#, ASTM A105N, RF/125AARH, ASME B16.5
Size- 2", B4A, 300#, ASTM A350 GR.LF2, RF/125AARH, ASME B16.5
Size- 6", A4A, 150#, ASTM A350 GR.LF2, RF/125AARH, ASME B16.5
Size- 4", A4A, 150#, ASTM A350 GR.LF2, RF/125AARH, ASME B16.5
Size- 2", A4A, 150#, ASTM A350 GR.LF2, RF/125AARH, ASME B16.5
Supply of Figure-8 as per details given below:
Size- 8", 30HCML, 300#, ASTM A105, ASME B16.48, FF/125AARH
Size- 8", B1A, 300#, ASTM A105N / A516 Gr.60N, ASME B16.48, FF/125AARH
Size- 4", B1A, 300#, ASTM A105N / A516 Gr.60N, ASME B16.48, FF/125AARH
Size- 2", B1A, 300#, ASTM A105N / A516 Gr.60N, ASME B16.48, FF/125AARH
Size- 4", B4A, 300#, ASTM A350 Gr.LF2, ASME B16.48, FF/125AARH
Size- 2", B4A, 300#, ASTM A350 Gr.LF2, ASME B16.48, FF/125AARH
Supply of Elbows as per details given below:
Size- 8" (90ᵒ), B1A, 300#, Sch - STD, BW, ASTM A234 Gr.WPB, Seamless, ASME B16.9
Size- 8" (45ᵒ), B1A, 300#, Sch - STD, BW, ASTM A234 Gr.WPB, Seamless, ASME B16.9
Size- 6" (90ᵒ), B1A, 300#, Sch - STD, BW, ASTM A234 Gr.WPB, Seamless, ASME B16.9
Size- 6" (45ᵒ), B1A, 300#, Sch - STD, BW, ASTM A234 Gr.WPB, Seamless, ASME B16.9
Size- 4" (90ᵒ), B1A, 300#, Sch - STD, BW, ASTM A234 Gr.WPB, Seamless, ASME B16.9
Size- 4" (45ᵒ), B1A, 300#, Sch - STD, BW, ASTM A234 Gr.WPB, Seamless, ASME B16.9
Size- 2" (90ᵒ), B1A, 300#, Sch - STD, BW, ASTM A234 Gr.WPB, Seamless, ASME B16.9
Size- 2" (45ᵒ), B1A, 300#, Sch - STD, BW, ASTM A234 Gr.WPB, Seamless, ASME B16.9
Size- 4" (90ᵒ), B4A, 300#, Sch - STD, BW, ASTM A420 Gr.WPL6, Seamless, ASME B16.9
Size- 4" (45ᵒ), B4A, 300#, Sch - STD, BW, ASTM A420 Gr.WPL6, Seamless, ASME B16.9
Size- 2" (90ᵒ), B4A, 300#, Sch - XS, BW, ASTM A420 Gr.WPL6, Seamless, ASME B16.9
Size- 2" (45ᵒ), B4A, 300#, Sch - XS, BW, ASTM A420 Gr.WPL6, Seamless, ASME B16.9
Size- 6" (90ᵒ), A4A, 150#, Sch - STD, BW, ASTM A420 Gr.WPL6, Seamless, ASME B16.9
Size- 6" (45ᵒ), A4A, 150#, Sch - STD, BW, ASTM A420 Gr.WPL6, Seamless, ASME B16.9
Size- 4" (90ᵒ), A4A, 150#, Sch - STD, BW, ASTM A420 Gr.WPL6, Seamless, ASME B16.9
Size- 4" (45ᵒ), A4A, 150#, Sch - STD, BW, ASTM A420 Gr.WPL6, Seamless, ASME B16.9
Size- 2" (90ᵒ), A4A, 150#, Sch - STD, BW, ASTM A420 Gr.WPL6, Seamless, ASME B16.9
Size- 2" (45ᵒ), A4A, 150#, Sch - STD, BW, ASTM A420 Gr.WPL6, Seamless, ASME B16.9
Supply of Equal Tee as per details given below:
Size- 8", B1A, 300#, Sch - STD, BW, ASTM A234 Gr.WPB, Seamless, ASME B16.9
Size- 4", B1A, 300#, Sch - STD, BW, ASTM A234 Gr.WPB, Seamless, ASME B16.9
Size- 2", B1A, 300#, Sch - STD, BW, ASTM A234 Gr.WPB, Seamless, ASME B16.9
Size- 4", B4A, 300#, Sch - STD, BW, ASTM A420 WPL6, Seamless, ASME B16.9
Size- 2", B4A, 300#, Sch - XS, BW, ASTM A420 WPL6, Seamless, ASME B16.9
Supply of Reducing Tee as per details given below:
Size- 8"x4", B1A, Sch STD, Sch STD, 300#, BW, ASTM A234 WPB, Seamless, ASME B16.9
Size- 4"x2", B1A, Sch STD, Sch STD, 300#, BW, ASTM A234 WPB, Seamless, ASME B16.9
Size- 4"x2", B4A, Sch STD, Sch XS, 300#, BW, ASTM A420 WPL6, Seamless, ASME B16.9
Size- 6"x4", A4A, Sch STD, Sch STD, 150#, BW, ASTM A420 WPL6, Seamless, ASME B16.9
Size- 4"x2", A4A, Sch STD, Sch STD, 150#, BW, ASTM A420 WPL6, Seamless, ASME B16.9
Supply of Reducer as per details given below:
Size- 8"x6", B1A, Sch STD, STD, 300#, BW, ASTM A234 Gr.WPB, Seamless, ASME B16.9, CONCENTRIC Note:-Reducer are under hold and shall be finalized post receipt of vendor data.
Size- 4"x2", A4A, Sch STD, STD, 150#, BW, ASTM A420 WPL6, Seamless, ASME B16.9, CONCENTRIC Note:-Reducer are under hold and shall be finalized post receipt of vendor data.
Supply of Swage as per details given below:
Size- 2"x1.5", B4A, Sch XS, XS, 300#, BW, SW, ASTM A420 WPL6, Seamless, ASME B16.9 Note:- Swage are under hold and shall be finalized post receipt of vendor data.
Size- 2"x1", B4A, Sch XS, XS, 300#, BW, SW, ASTM A420 WPL6, Seamless, ASME B16.9 Note:- Swage are under hold and shall be finalized post receipt of vendor data.
Size- 2"x0.75", B4A, Sch XS, XS, 300#, BW, SW, ASTM A420 WPL6, Seamless, ASME B16.9 Note:- Swage are under hold and shall be finalized post receipt of vendor data.
Supply of Weldolet's as per details given below:
Size- 8"x2", 30HCML, Thk. - 6.4, Sch. - STD, 300#, BW, ASTM A105, MSS SP-97
Size- 8"x2", B1A, Sch - STD, STD, 300#, BW, ASTM A105N, MSS SP-97
Size- 6"x2", A4A, Sch - STD, STD, 150#, BW, ASTM A350 Gr. LF2, MSS SP-97
Supply & Installation OF Piping Speciality Items as per details given below:
Supply & Installation of Hose Coupling for 4", A4A, 150#
Supply & Installation of Hose Coupling for 2", B1A, 300#
Supply & Installation of HoseCoupling for 2", A4A, 150#
Radiography:
Performance of radiographic inspection of piping of all types, sizes, thickness including providing or hiring of all necessary equipment, supply of all consumables including radiographic films and whatever else even though not expressly mentioned but required to perform the work as per specification and instructions of Engineer-in-Charge. Contractor to submit DPR, Inspection Report along with Radiography Report to Engineer-in-Charge. Note : a) All NDT including Radiography, MPT, LPT for below 2" are covered under this SOR item. No separate payment shall be made. Radiography of piping joints as per details given below:
Pipe Supports
Supply, fabrication and erection of pipe/ equipment supports (for all sizes/ thickness) including shoes, pipes etc. as required, cradles, turn buckles, T-posts for all types of guides, anchors, special supports for cold/hot insulated pipes etc. if applicable, all necessary equipment, consumables, labour etc. for completing all works including supply of bolts, nuts, washers, U-clamps, wooden blocks etc. as required for supporting, supply and application of paints and primers suitable for normal corrosive painting environment as defined in contract document and as per standard specification for painting specification no. VCS-SS-PP-2502, Drawings, Specification, Standards, other provisions of Contract and instruction of Engineer-in-Charge.
MS Structural Steel
Painting
Supply of paints, solvents and primers, preparation of surfaces and application of primer and finish paints suitable for highly corrosive/ coastal and marine painting environment as defined in contract document and on pipes as per standard specification for painting specification no. VCS-SS-PP-2502, identification, lettering/ numbering, colour coding etc. as specified including rub down and touch up of shop primer or scrapping of shop primer wherever required and providing of scaffolding for all heights, labour, materials, tools and tackles, consumables, supervision etc. to complete the work in all respect as per Specification, Drawings, Standards and instruction of Engineer-in-Charge. Note : a) All painting work for sizes below 2" are covered under this SOR item. No separate payment shall be made.
Painting of all above ground piping including all fittings, valves, flanges etc. and including colour bands
Size - 8", Painting Environment - Highly Corrosive Environment (Above Ground).
Size - 6", Painting Environment - Highly Corrosive Environment (Above Ground).
Size - 4", Painting Environment - Highly Corrosive Environment (Above Ground).
Size - 2", Painting Environment - Highly Corrosive Environment (Above Ground).
Repair of Painting of Equipments / skids Suitable for Normal corrosive/Highly Corrosive Environment
Scraper Launcher / Receiver
Basket Filter
Metering Skid
Pressure Regulation Skid
Hook-up with existing facilities.
Supply of all materials, equipment, consumables as defined in Contractor's scope of supply and their transportation to the work site(s); performing fabrication works & Hook-up with existing piping including cutting & bevel preparation of existing line for welding/ Hook-up.
Flange, Size - 8.0 Inch
Leaks / Bursts (Attributable to Owner) (For Terminal Piping)
Leaks / Bursts (Attributable to Owner): All works for leak/burst (occurring during hydrostatic testing) including necessary repair/replacement of defective pipe length, including cutting and removing out defective pipes, welding, NDT of welds, repair and re-testing of defective welds, painting of welded joints, clean-up, re hydro testing of the pipe segment including providing all necessary equipments, labour, materials, consumables and inputs other than Owner supplied materials and performing all works as per drawings, specifications enclosed with the Contract and directions of Engineer-in-Charge. Note : This rate shall be applicable for manufacturing defects in Company supplied materials only.
Supply/ Installation/ Fabrication/ Erection of Vent Stack Including Flame Arrester with Rain Cap
Supply, Installation, fabrication and erection of Vent Stack including Flame Arrestor of Detonation type (including flanges) with a loose fitting Rain Cap with chain, including all necessary fabrication works, including providing all necessary equipment, labour, materials, consumables and inputs other than Owner supplied materials and performing all works as per drawings, data sheet, specifications enclosed with the Contract and directions of Engineer-in-Charge.
Vent Stack including Flame Arrestor (including flanges) with Rain Cap, Size - 6", A4A, 150#
Vent Stack including Flame Arrestor (including flanges) with Rain Cap, Size - 4", A4A, 150#
Nitrogen Supply & Commissioning of Terminal
Supply of Nitrogen for purging for terminal commissioning and during hook of piping with existing piping
Installation of Mechanical Equipments
Transportation of all equipments (Static & Rotary), Filter Sepertator / Ultrasonic Meter along with all accessories supplied by supplier etc. from owner's storage point / designated location to work site including loading and unloading from within station, erection of all static / rotary equipments including layout marking at site, alignment, fabrication and installation of shims including cutting and grinding, installation and levelling of base plates, assembly of sub-assemblies, bolting, fitting of all interconnected piping from diesel day tank to diesel engine, exshaust piping of diesel engine (supplied by equipment supplier), installation of rigging apparatus for erection crane, alignment of equipment at all elevations as per drawings, Instaallation of electric panel, electric equipment, removal, placing and shifting of stools and saddles including loading and unloading, installation of all mountings and accessories, all enabling work as required, and completing the work in all respects as per drawings, specification, codes and instruction of Engineer-in-Charge. Note: a) Actual rate shall be paid to contractor based on actual weight of items.
Installation of Basket Filters / Metering Skid / Pressure Regulation Skid
Installation of Basket Filter (2 Nos.)
Installation of Metering Skid (1 Nos.)
Installation of Pressure Regulation Skid (1 Nos.)
Supply of Vertical, Cylindrical, Skirt mounted Basket Filter with Design Flowrate of 185 m3/hr with Inlet & Outlet Nozzle size 8” NB, ANSI Rating 300# respectively including supply of filter element, and blind flanges for nozzles as required as per attached P&I Diagram, Process Data Sheet, Mechanical Data Sheet and Technical Specification etc.
Gasket for all flange joints as Mandatory Spares (each filter)
Fasteners for all flange joints as Mandatory Spares 20% (Min. 04 Nos. of each size & type) for each filter.
Basket Filter Elements as Madnatory spares
Gasket for all flange joints as Pre-commissioning & Commissioning Spares
Fasteners for all flange joints as Pre-commissioning & Commissioning Spares 10% (Min. 02 Nos. of each size & type)
Supervision during pre-commissioning & commissioning. (Per Diem Rate for both filter)
Supply and Installation of Fire Extinguisher Note:-Contractor to check and supply the Fire Extinguisher Items / Quantity as per the PNGRB & OISD requirement.
10 Kg DCP
Sand Bucket with Stand
Pre-Commissioning and Commissioning of Terminal
Carrying out pre-commissioning checks and commissioning assistance to Client during during commissioning of terminal including supply of all adequate nitrogen for purging equipment, manpower, consumables, materials for all temporary works and performing all associated works, complete as per the relevant specifications, other provisions of Contract document and instructions of Engineer-in-Charge. Note: Work shall include hook up with existing piping
FIREWATER
Piping Works for the Fire Water Network System at Dispatch & Receipt Station (NRL)
Fabrication, Erection, Installation and Testing of Fire Water Network Piping Receiving and taking over of all Owner supplied materials from Owner's designated place(s) of issue, transportation including loading, unloading, handling from Owner's designated place(s) of issue to Contractor's own stock yard(s)/ work site(s)/ work shop(s) including arranging all necessary intermediate storage area(s) thereof, as required;supply of all materials (except those specified subsequently in SOR), equipment, consumables as defined in Contractor's scope of supply and their transportation to the work site(s); performing all above ground/buried piping fabrication works including cutting, edge preparation (inclusive of grinding the edges of pipes, fittings, flanges etc. to match with the matching edges of uneven/ different thickness wherever required), fit up, bending, pre-heating wherever required, welding, threading etc.; erection of pipes of all types and thickness over sleepers, overhead on racks and at all elevations; hook-up with equipment nozzles; all types of inline and online instruments fittings of all sizes elbows, reducers, tees, 'o' lets, flanges, blind flanges, spectacle blinds, tappings for pressure gauges, thermowells, hoses and hose couplings of all sizes,if applicable, vents and drains required for hydrotesting purposes etc. including fixing of all types of gaskets bolts, studs and nuts of all sizes; carrying out non-destructive testing (excluding radiography covered subsequently in SOR) such as magnetic particle/ liquid penetration etc. as required; hook-up with existing piping installed by others as per drawings wherever required; cleaning and flushing by water/ compressed air, carrying out hydrostatic test, pneumatic test, valve functional test and any other type of testing as specified, de-pressurising, dewatering, drying by compressed air if applicable; cutting/ rebeveling (as required), pre-commissioning and providing commissioning assistance clean-up and restoration of site, preparation of as built drawings, documents and project records; transportation of surplus free issue materials to Owner's designated place(s); completing all works in all respects as per the AFC drawings, specifications, standards and other provisions of Contract and instruction of Engineer-in-Charge. Note :- a) All butt welded fittings end shall generally match with connecting pipe wall thickness. However, in case of misalignment, contractor shall have to do end preparation accordingly without any extra cost. b) All couplings, nipples etc. as required shall be supplied by contractor without any extra cost. c) All Gaskets & Nut-Bolts of adequate quantity shall be supplied and installed without any extra cost. d) All pipes, valves and fittings etc. below 2' as required shall be supplied by contractor without any extra cost.
Installation of Above Ground Fire Water Network Piping as per detail given below:
Size-8", Thk. 6.0, Material - IS:3589, Gr.410, Welded, Internal Coated, BE, IS:3589
Size-6", Sch. Hvy., Material - IS:1239 (Black), Welded, Internal Coated, BE, IS:1239-1
Size-4", Sch. Hvy., Material - IS:1239 (Black), Welded, Internal Coated, BE, IS:1239-1
Installation of Above Ground Fire Water Network Piping (Galv.) as per detail given below:
Size-2", Sch. Hvy., Material - IS:1239 (Black), Welded, Galvanized, Threaded., IS:1239-1
Size-3", Sch. Hvy., Material - IS:1239 (Black), Welded, Galvanized, Threaded., IS:1239-1
Installation of Under Ground Fire Water Network Piping as per detail given below: (Note:-Installation Works including trenching, coating of Pipe & Fittings with min. 1000 Micron Solid Epoxy (i.e Powercrete R95) & Backfilling all complete (Bidder to Quote Accordingly).
Size-8", Thk. 6.0, Material - IS:3589, Gr.410, Welded, Internal Coated, BE, IS:3589
Size-2", Sch. Hvy., Material - IS:1239 (Black), Welded, Galvanized, Threaded., IS:1239-1
Installation of Valves
Receiving and taking over of all Owner supplied materials, equipments from Owner's designated place(s) of issue, transportation including loading, unloading, handling from Owner's designated place(s) of issue to Contractor's own stock yard(s)/ work site(s)/ work shop(s) including arranging all necessary intermediate storage area(s) thereof, as required; supply of all materials, equipment, consumables as defined in Contractor's scope of supply and its transportation to the work site(s);installation of valves, flow meters, equipments including fixing of gaskets, bolts, studs, nuts wherever required, levelling, aligning, installation and assembly of accessories including accessories for actuators including making electrical connections for such actuators, if any, by bolting/threading or welding of pipes at all elevations, testing, completing all works in all respects as per drawings, specification, other provisions of Contract and directions of the Engineer-in-Charge.
Installation of Above Ground Fire Network Flanged Valves (Gate / Globe / Check / Ball) as per detail given below:
Size-8", Rating-#150
Size-6", Rating-#150
Size-4", Rating-#150
Size-2", Rating-#150
Installation, Testing & Commisioning of ROVs (Deluge Valve) (Pneumatic actuator) as per site requirement. as per site requirement. Installation & Testing pf Spring Return, Single Acting Actuated valve of size and their accessories inclusive of supply of necessary piping / tubing along with necessary Tubing and tube fittings, including cabling, glanding, termination, earthing.
Deluge Valve 6", #150
Installation of Double Hydrant as per detail given below:
Double Hydrant 4", #150
Installation of Water Monitor as per detail given below:
Water Monitor 4", #150
Erection, Testing & Commissioning of Medium Velocity Water Spray System (MVWSS) Nozzle along with matching Fittings as per Data Sheets, Specification and Direction of Engineer-in-charge for following capacity. Note: Rechecking of basic package with contractor agency
Size - 1/2 inch
Supply Including Procurement and Transportation to work site (S) / Workshop (S) Including Loading, Unloading and Handling for the following materials to be supplied by Contractor, as per requirement of PMS, Data Sheets, Specification and Standards. Instruction of Owner, Engineer-in-charge and other provision of contract.
Pipes
Supply of Pipe for Fire Water Network as per detail given below:
Size-8", Thk. 6.0, Material - IS:3589, Gr.410, Welded, Internal Coated, BE, IS:3589
Size-6", Sch. HVY., Material - IS:1239 (Black), Welded, Internal Coated, BE, IS:1239-1
Size-4", Sch. HVY., Material - IS:1239 (Black), Welded, Internal Coated, BE, IS:1239-1
Supply of Pipe (Galv.) for Fire Water Network as per detail given below:
Size-2", Sch. HVY., Material - IS:1239 (Black), Welded, Galvanized, Threaded., IS:1239-1
Size-3", Sch. HVY., Material - IS:1239 (Black), Welded, Galvanized, Threaded., IS:1239-1
Valves
Supply of Flanged Ends Gate Valves for Fire Water Network as per attached Data Sheet with Station Works Tender, as per detail given below:
Gate Valve 8", A94AL, Body-ASTM A216 Gr. WCB, Internally Coated, Trim-Bronze, #150, Flanged, API 600 / 6D
Gate Valve 6", A94AL, Body-ASTM A216 Gr. WCB, Internally Coated, Trim-Bronze, #150, Flanged, API 600 / 6D
Gate Valve 4", A94AL, Body-ASTM A216 Gr. WCB, Internally Coated, Trim-Bronze, #150, Flanged, API 600 / 6D
Supply of Flanged Ends Gate Valves (Galv.) for Fire Water Network as per attached Data Sheet with Station Works Tender, as per detail given below:
Gate Valve 2", A94AL, Body-ASTM A216 Gr. WCB, Galvanized, Trim-Bronze, #150, Flanged, API 600 / 6D
Gate Valve 3", A94AL, Body-ASTM A216 Gr. WCB, Galvanized, Trim-Bronze, #150, Flanged, API 600 / 6D
Supply of Flanged Ends Ball Valves for Fire Water Network as per attached Data Sheet with Station Works Tender, as per detail given below:
Ball Valve 2", A3A, Body-ASTM A216 Gr. WCB, Trim-13% CR, 150#, ASME B16.5, RF / 125AARH, API 608 / API 6D
Flanges & Fittings
Supply of Weld Neck Flat Face Flanges for Fire Water Network as per detail given below:
Size- 8", A94AL, #150, ASTM A105N, Internally Coated, FF, WN, B16.5
Size- 6", A94AL, #150, ASTM A105N, Internally Coated, FF, WN, B16.5
Size- 4", A94AL, #150, ASTM A105N, Internally Coated, FF, WN, B16.5
Supply of Flat Face Threaded Flanges (Galv.) for Fire Water Network as per detail given below:
Size- 2", A94AL, #150, ASTM A105N, Galvanized, FF, Threaded, B16.5
Size- 3", A94AL, #150, ASTM A105N, Galvanized, FF, Threaded, B16.5
Supply of Blind Flanges Flat Face for Fire Water Network as per detail given below:
Size- 8", A94AL, #150, ASTM A105N, Internally Coated, FF, B16.5
Size- 6", A94AL, #150, ASTM A105N, Internally Coated, FF, B16.5
Size- 4", A94AL, #150, ASTM A105N, Internally Coated, FF, B16.5
Supply of Blind Flanges (Galv.) Flat Face for Fire Water Network as per detail given below:
Size- 3", A94AL, #150, ASTM A105N, Galvanized, FF, B16.5
Size- 2", A94AL, #150, ASTM A105N, Galvanized, FF, B16.5
Supply of Elbows for Fire Water Network as per detail given below:
Size- 8" (90ᵒ), A94AL, Sch. STD., ASTM A234 Gr.WPB, Internally Coated, Seamless, BE, B16.9
Size- 8" (45ᵒ), A94AL, Sch. STD., ASTM A234 Gr.WPB, Internally Coated, Seamless, BE, B16.9
Size- 6" (90ᵒ), A94AL, Sch. STD., ASTM A234 Gr.WPB, Internally Coated, Seamless, BE, B16.9
Size- 6" (45ᵒ), A94AL, Sch. STD., ASTM A234 Gr.WPB, Internally Coated, Seamless, BE, B16.9
Size- 4" (90ᵒ), A94AL, Sch. STD., ASTM A234 Gr.WPB, Internally Coated, Seamless, BE, B16.9
Size- 4" (45ᵒ), A94AL, Sch. STD., ASTM A234 Gr.WPB, Internally Coated, Seamless, BE, B16.9
Supply of Elbows (Galv.) for Fire Water Network as per detail given below:
Size- 2" (90ᵒ), A94AL, #3000, ASTM A105N, Galvanized, Threaded, Forged, B16.11
Size- 2" (45ᵒ), A94AL, #3000, ASTM A105N, Galvanized, Threaded, Forged, B16.11
Size- 3" (90ᵒ), A94AL, #3000, ASTM A105N, Galvanized, Threaded, Forged, B16.11
Size- 3" (45ᵒ), A94AL, #3000, ASTM A105N, Galvanized, Threaded, Forged, B16.11
Supply of Equal Tee for Fire Water Network as per detail given below:
Size- 8", A94AL, Sch. STD., ASTM A234 Gr.WPB, Intrnally Coated, Seamless, BE, B16.9
Supply of Reducing Tee for Fire Water Network as per detail given below:
Size- 8"x6", A94AL, Sch. STD. x Sch. STD., ASTM A234 Gr.WPB, Internally Coated, Seamless, BE, B16.9
Supply of Sockolet (Galv.) for Fire Water Network as per detail given below:
Size- 2"x1", A94AL, #3000 x #3000, ASTM A105N, Galvanized, Threaded, Forged, B16.11
Supply of Equal Tee (Galv.) for Fire Water Network as per detail given below:
Size- 2", A94AL, #3000, ASTM A105N, Galvanized, Threaded, Forged, B16.11
Size- 3", A94AL, #3000, ASTM A105N, Galvanized, Threaded, Forged, B16.11
Supply of Concentric / Eccentric Reducer (Galv.) for Fire Water Network as per detail given below:
Size- 3"x2", A94AL, #3000 x #3000, ASTM A105N, Galvanized, Threaded, Forged, B16.11
Supply of Swage Nipple (Galv.) for Fire Water Network as per detail given below:
Size- 2"x1.5", A94AL, #3000 x #6000, ASTM A105N, Galvanized, Threaded, Forged, B16.11
Supply of Full Coupling (Galv.) for Fire Water Network as per detail given below:
Full Coupling 2", A94AL, #3000, ASTM A105N, Galvanized, Threaded, Forged, B16.11
Full Coupling 3", A94AL, #3000, ASTM A105N, Galvanized, Threaded, Forged, B16.11
Supply of Union (Galv.) for Fire Water Network as per detail given below:
Union 2", A94AL, #3000, ASTM A105N, Galvanized, Threaded, Forged, B16.11
Union 3", A94AL, #3000, ASTM A105N, Galvanized, Threaded, Forged, B16.11
Supply of Cap (Galv.) for Fire Water Network as per detail given below:
Cap 2", A94AL, #3000, ASTM A105N, Galvanized, Threaded, Forged, B16.11
Cap 3", A94AL, #3000, ASTM A105N, Galvanized, Threaded, Forged, B16.11
Supply of Plug (Galv.) for Fire Water Network as per detail given below:
Plug 2", A94AL, #3000, ASTM A105N, Galvanized, Threaded, Forged, B16.11
Plug 3", A94AL, #3000, ASTM A105N, Galvanized, Threaded, Forged, B16.11
Supply of Double Hydrant for Fire Water Network as per detail given below:
Double Hydrant 4", A33Y, #150
Supply of Water Monitor for Fire Water Network as per detail given below:
Water Monitor 4", A33Y, #150
Supply of Medium Velocity Water Spray System (MVWSS) Nozzle along with matching Fittings as per Data Sheets, Specification for following Capacity.
Size - 1/2 inch, Body, Pin & Deflector - Nickel Aluminum Bronze, Nozzle K-51, Angle 90 deg.
Size - 1/2 inch, Body, Pin & Deflector - Nickel Aluminum Bronze, Nozzle K-64, Angle 90 deg.
Radiography:
Performance of radiographic inspection of piping of all types, sizes, thickness including providing or hiring of all necessary equipment, supply of all consumables including radiographic films and whatever else even though not expressly mentioned but required to perform the work as per specification and instructions of Engineer-in-Charge. Contractor to submit DPR, Inspection Report along with Radiography Report to Engineer-in-Charge. Note : a) All NDT including Radiography, MPT, LPT for 2" and below are covered under this SOR item. No separate payment shall be made. Radiography of piping joints as per details given below:
Size - 8.0 Inch
Size - 6.0 Inch
Size - 4.0 Inch
Size - 3.0 Inch
Size - 2.0 Inch
Pipe Supports
Supply, fabrication and erection of pipe/ equipment supports (for all sizes/ thickness) including shoes, pipes, cross-overs, platforms, ladders, railings etc. as required, cradles, turn buckles, T-posts for all types of guides, anchors, special supports for cold/hot insulated pipes etc. if applicable, all necessary equipment, consumables, labour etc. for completing all works including supply of bolts, nuts, washers, U-clamps, wooden blocks etc. as required for supporting, supply and application of paints and primers suitable for highly corrosive painting environment as defined in contract document and as per standard specification for painting specification, No. VCS-SS-PP2502, Drawings, Specification, Standards, other provisions of Contract and instruction of Engineer-in-Charge.
MS Structural Steel
Painting
Supply of paints, solvents and primers, preparation of surfaces and application of primer and finish paints suitable for highly corrosive painting environment as defined in contract document and on pipes as per standard specification for painting specification, No. VCS-SS-PP-2502, identification, lettering/ numbering, colour coding etc. as specified including rub down and touch up of shop primer or scrapping of shop primer wherever required and providing of scaffolding for all heights, labour, materials, tools and tackles, consumables, supervision etc. to complete the work in all respect as per Specification, Drawings, Standards and instruction of Engineer-in- Charge. Note : a) All painting work for sizes below 2" are covered under this SOR item. No separate payment shall be made.
Painting of all Above Ground Fire Water Network Piping including all Fittings, Valves, Flanges etc.
Size - 8.0 Inch
Size - 6.0 Inch
Size - 4.0 Inch
Size - 3.0 Inch
Size - 2.0 Inch
Hook-up with Existing Facilities.
Supply of all materials, equipment, consumables as defined in Contractor's scope of supply and their transportation to the work site(s); performing fabrication works & Hook-up with existing fire water network including cutting & bevel preparation of existing line for welding/ Hook-up.
Above Ground Fire Water Network
Size - 8.0 Inch
Size - 2.0 Inch
Leaks / Bursts (Attributable to Owner) (For Terminal Piping)
Leaks / Bursts (Attributable to Owner): All works for leak/burst (occurring during hydrostatic testing) including necessary repair/replacement of defective pipe length, including cutting and removing out defective pipes, welding, NDT of welds, repair and re-testing of defective welds, painting of welded joints, clean-up, re hydro testing of the pipe segment including providing all necessary equipments, labour, materials, consumables and inputs other than Owner supplied materials and performing all works as per drawings, specifications enclosed with the Contract and directions of Engineer-in-Charge. Note : This rate shall be applicable for manufacturing defects in Company supplied materials only.
Commissioning of Terminal.
Carrying out pre-commissioning checks and commissioning assistance to Client during commissioning of terminal including supply of all adequate nitrogen for purging equipment, manpower, consumables, materials for all temporary works and performing all associated works, complete as per the relevant specifications, other provisions of Contract document and instructions of Engineer-in-Charge
ENVIRONMENT FRIENDLY INERT GAS BASED CLEAN AGENT SYSTEM
E&I Building as per drawing of size 18 m X 8 m x 3.85 (h) comprising Instrumentation Room of size 6m X 8m X 3.85m, Electrical Room of Size 9m X 8m X 3.85m & Battery Room of Size 3m X 8m X 3.85m
DUMP TEST FOR SMALLEST ROOM & REPLACEMENT /REFILLING OF CYLINDERS AFTER DUMP TEST.: Carrying out Dump test for smalllest room by discharging inert gas (same inert gas that has been considered for clean agent fire suppression system) from requisite number of cylinders for that room as per design and performing dump test for demonstrating the effectiveness of system. Removing of empty cylinders from manifold , transportations to & fro , Refilling of all discharged cylinders and making the complete system ready for use in all respects after dump test.
Refilling of empty 300 Bar 140 Ltrs water capacity clean agent (Inert Gas based) cylinder.Rate inclusive of To & Fro Transportation.
Lump sum Comprehensive Annual Maintenance Servicing contract (CAMC) for Clean Agent System, inclusive of manpower, spare, consumables, etc. for 1st year after completion of warrantee period. CAMC will consist of two parts. a) Preventive maintenance at regular interval by OEM. (Half yearly basis). b) Break down maintenance as and when required within AMC by OEM.
Lump sum Comprehensive Annual Maintenance Servicing contract (CAMC) for Clean Agent System, inclusive of manpower, spare, consumables, etc. for 2nd year after completion of warrantee period. CAMC will consist of two parts. a) Preventive maintenance at regular interval by OEM. Half yearly basis. b) Break down maintenance as and when required within AMC by OEM.
Supply of Mandatory Spares 1 Cylinder 140L IG541 300 Bar Filled - 1 Nos 2 Cylinder valve safety pressure relief device - 1 Nos 3 Pneumatic Actuator - 1 Nos 4 Pneumatic/Manual Actuator - 1 Nos 5 Solenoid Actuator inc plug + emf diode - 1 Nos 6 Discharge Nozzle Assembly- 2 Nos 7 Gas Release Unit - 1 Nos 8 Gas Inhibit Unit - 1 Nos 9 Cylinder Pressure Gauge - 2 Nos 10 Discharge Hose- 2 Nos 11 Actuation Hose + Adaptor (600)- 1 Nos
CIVIL
Earth work in Site Grading(VCS-SS-CS-6002)
Earthwork in excavation and filling in all types of soil for general site grading for all heights and depths including clearing and stripping etc. in excavation areas, removing shrubs, grass, bushes, vegetable growth and other objectionable materials, trees upto and inclusive of a girth of 30 cms. (girth measured at a height of one metre above ground level) including uprooting of roots, etc., dewatering, if necessary, sorting out the excavated soil into serviceable and unserviceable materials in excavation areas and including filling in filling areas with serviceable material for general site grading and roads for all heights and depths to proper levels, slopes, grades and camber including clearing and stripping in filling areas as per specifications, consolidating exposed natural soil to 90% of max. laboratory dry density as per IS:2720 Part-VII, cutting of trees of girth upto and inclusive of 30 cms, removal of vegetation, breaking clods, spreading in layers not exceeding 30 cms loose thickness, watering, ramming and compacting with power road rollers to give at least 90% of max. laboratory dry density, dressing, leveling, testing, etc. and disposal of unserviceable materials/surplus earth if any, as directed by Engineer-in-Charge including stacking and/or dumping and dressing the same in demarcated areas etc. complete as per specifications, drawings and directions of Engineer-in-Charge.
Misc. Items(VCS-SS-CS-6030)
SAND FILLING
Supplying and filling approved SAND of specified quality under floors, in foundations, plinths, tank foundations etc. for all depths and heights including cost of sand,royalties, transportation to site for all leads and lifts,including loading, unloading, spreading in layers of loose thickness not exceeding 150 mm,watering,ramming,compacting with mechanical compactors and/or other equipment to the specified levels to achive 85% relative density as per IS:2720 Part XIV,including preparation of subgrade to the required slope,providing testing apparatus and testing the degree of consolidation all complete as per drawings, specifications and direction of Engineer-in-charge.The rates shall be inclusive of the cost of all labour,material,equipments etc. all complete.
RCC ROAD
Supplying and laying of stone aggregate of 63mm down to 45mm size for WBM layer Base Course, tough, sound, clean and durable including cost of stone aggregate, all royalties, taxes, handling, transportation to site, unloading the same by the side of road with all leads and lifts, spreading and laying to form water bound macadam in one layer of 75mm compacted thickness to proper grade, camber and level, filling voids with screenings and binding material of plasticity index up to 6%, including cost of supply of screening and binding material, consolidating with power driven road roller, watering, with all leads and lifts etc. complete as per drawings, specifications and directions of Engineer-in-Charge.
Providing and laying Reinforced Cement Concrete of M-25 grade with 20mm and down size graded crushed stone aggregates in pavements etc, making recess/drains, laying in alternate panels, laying of 0.125 mm polyethylene sheet above WBM layer, filling the gaps between the panels with bitumen sand mix filler material etc. for all depths including shuttering, tamping, curing, etc. as specified in any shape, thickness, position and finishing the top surface smooth etc. all complete as per drawings, specifications and directions of Engineer-in-Charge.
KERB STONE FIXING
Providing and fixing precast concrete Kerb stones (125 wide X 300 deep) of M-30 grade or equivalent of approved make and shape at or near ground level as per approved pattern and setting in position with cement mortar 1:3 (1 cement : 3 coarse sand) including the cost of required centering, shuttering and finishing smooth with 6 mm thick cement plaster 1:3 (1 cement : 3 fine sand) wherever required over 75 mm thick PCC 1:4:8 levelling course, complete in all respects as per scope of work, detailed construction drawings, technical specifications and directions of the Engineer-In-Charge. Note:- 1. Rate to include all labour, tools, tackles, factory manufactured & steam cured Kerb Stones, shuttering, transportation, water charges, earth work if any, PCC etc complete.
ERC/IRC
Construction of ERC/IRC as per Standards including supplying and laying in position PVC pipes conforming to IS:4985 Class-I for electrical and instrumentation Road Crossings as per standard drawing and its addendum, including cutting the pipes if necessary, lowering, laying in position to proper levels, etc. embedded in M-20 grade concrete, providing proper jointing as per code requirements or manufacturer's recommendations, etc. including earth work in excavation in all types of soil except soft and hard rock, backfilling and making good the surface, including cutting of new/ existing roads and making good the same including supply of any road material if required, (Back filling with road material shall be done in 150 mm thick layers well watered and compacted), including supplying and providing in the encasement concrete, cable crossing indicator made out of 4 mm thick MS circular plate of dia. 150mm welded to 16 mm dia. MS rod of approximately 1.0 m length and painting and lettering with 2 coats of approved enamel paint of approved colour over a coat of red oxide primer etc., supply and fixing of reinforcement as per drawing, including disposal of surplus earth anywhere within plant boundary limit etc. all complete as per drawings, specifications and instructions of Engineer-in-Charge.
Earth Work in Foundations(VCS-SS-CS-6022)
Earth work in EXCAVATION below ground level for all kinds of works in ALL TYPES OF SOILS EXCEPT SOFT ROCK AND HARD ROCK as classified in specification for a depth upto 1.5m including removal of vegetation, shrubs and debris, cutting and dressing of sides in slopes, levelling, grading and ramming of bottoms, dewatering of accumulated water from any source and keeping the surface dry for subsequent works and disposal or stacking of excavated material within a lead of 100m, as directed including providing temporary supports to existing service lines like water pipes, sewage pipes, electric overhead and underground cables etc. all complete, but excluding shoring and strutting.
For depth beyond 1.5m and upto & inclusive of 3.0m.
Transporting and disposing the SURPLUS EARTH AND DEBRIS including shrubs and vegetations from construction area beyond the initial lead of 100M including re-excavating the deposited soil excavated earlier, transportation, loading, unloading, laying at all depths and heights, stacking, levelling and dressing both the area (viz. from where the earth is transported and where it is deposited) to required levels and slopes complete with all lifts as directed. For carting on the basis of truck measurements (volume of truck reduced by 30% for voids) i) Upto 1.0Km.
Plain & Reinforced Concrete(VCS-SS-CS-6023)
Concrete of nominal mix of 1:3:6 by volume (1 Cement : 3 Coarse Sand :6 Crushed Stone Aggaregates/Gravels).
Providing and laying PLAIN CEMENT CONCRETE for all depths below and upto plinth level in foundations,drains, fillings, non-suspended floors, pavements & ramps or any other works etc. including shuttering, tamping, ramming, vibrating, curing etc. all as specified in any shape, position, thickness and finishing the top surface rough or smooth as specified and directed all complete for concrete of nominal mix 1:4:8 by mass (1 Cement: 4 Coarse Sand: 8 Crushed Stone Aggregates/Gravels) with 40mm and down size graded crushed stone aggaregates/Gravels.(ALL MATERIALS INCLUDING CEMENT SUPPLIED BY CONTRACTOR AT THEIR COST)
Providing and laying REINFORCED CEMENT CONCRETE OF M-30 GRADE with 20mm and down size graded crushed stone aggregates/gravel in SUB-STRUCTURE of all types e.g. foundations, footings, raft, beams, slabs, pile caps, retaining walls, jambs, counterforts, buttresses, trenches, manholes,pipe encasement, catchpits, drains, RCC pits, equipment/machine foundations, pedestals, pipe sleepers, columns, plinth beams, suspended floors, beams, staircases, landings, steps, brackets etc. (including single pour concreting upto 250m3), including cost of admixtures if used,providing pockets, openings, recesses, chamfering etc., wherever required, vibrating, tamping, curing and rendering if required to give a smooth and even surface etc. all complete (excluding the Cost of Reinforcement and Shuttering) for all depths below and upto plinth level in any shape, position and thickness etc. all complete as specified, shown and directed. (ALL MATERIALS INCLUDING CEMENT SUPPLIED BY CONTRACTOR AT THEIR COST).
Providing and laying REINFORCED CEMENT CONCRETE OF M-30 GRADE with 20mm and down size graded crushed stone aggregates/gravel in SUPER STRUCTURE in suspended floors, slabs, beams, columns, walls including counterforts, staircases, landings, steps, facias, fins, mouldings, gutters, shelves, windowsills, canopies, lintels, girders, ducts, brackets, chajjas with drip moulds, pedestals, posts, struts, equipment/machine foundations, ramps etc. (including single pour concreting upto 250m3) including cost of admixtures if used providing pockets, openings, recesses, chamfering wherever required, vibrating, tamping, curing and rendering if required to give a smooth and even surface etc. all complete (excluding the Cost of Reinforcement and Shuttering) for all heights above plinth level in any shape, position, thickness etc. all complete as specified, shown and directed.
CENTERING AND SHUTTERING Providing and fixing CENTERING AND SHUTTERING in foundations, footings, raft beams, slabs, pile caps, retaining walls, jambs, counter-forts, buttresses, trenches, equipment/machine foundations, pedestals, abutments, pipe sleepers, columns, plinth beams, lintels, suspended slabs, beams, staircases, landings, steps, non-circular tunnels/bunkers/silos/ shafts/ hoppers/liquid storage structures etc. including shuttering for single pour concreting, strutting, bracing, propping etc., keeping the same in position during concreting and removal of the same after specified period etc. for Straight/ Inclined Shuttering, keeping necessary provision for inserts, projecting dowels, anchor bolts or any other fixture etc. all complete and as specified and directed.
i) For all depths below and upto & inclusive of plinth level.
ii) For all heights above plinth level.
REINFORCEMENT
Supplying and placing in position HIGH STRENGTH DEFORMED STEEL BARS REINFORCEMENT (conforming to IS:1786, Grade Fe 500D), for R.C.C. work including transporting the Steel, straightening, cleaning, decoiling, cutting, bending to required shapes and lengths as per details, binding with contractor's own 16 SWG black soft annealed binding wire at every intersection, supplying and placing with proper cover blocks, supports, chairs, overlaps, welding, spacers, fanhooks etc. for all heights and depths etc. all complete as directed.(SUPPLY OF ALL MATERIAL IN CONTRACTOR'S SCOPE).
Structural Steel Works(VCS-SS-CS-6024)
Supplying, transporting, storing, fabricating in position and testing/examining bolted and/or welded STRUCTURAL STEEL WORKS at all levels and locations including all builtup sections/compound sections made out of rolled sections and/or plates/bent plates in trusses, purlins, wind ties, wind girders, columns, portals, racks, frameworks, crane gantries, surge girders, bracings, floor beams, lifting beams, monorails, platforms, staircases (excluding chequered plates and gratings), ladders, stoppers, brackets, side runners, sagrods, supports for equipment and technological accesories and process piping, hand railings, posts, conveyor galleries, trestles, towers, masts, junction houses etc., cutting to required size, straightening/ bending if required, edge preparation, cleaning, preheating, bolting/welding of joints, (including sealing the joints of box sections with continuous welding), finishing edges by grinding, fixing in line and level with temporary staging & bracing and removal of the same after erection, grouting with Ordinary Grout or premix free flow Nonshrink Grout as specified, including preparation and submission of detailed fabrication drawings, preparing the surface for painting and applying shop primer as per Specification No. 6-44-0004 (or Job Specification, wherever applicable) after fabrication etc. all complete. SUPPLY OF ALL MATERIAL IN CONTRACTOR'S SCOPE.
Supplying and applying FINISH PAINT of approved quality and shade including a coat of primer as per Specification/BIS Codes over one coat of shop primer already applied including storage, surface preparation, degreasing, cleaning, drying, touching up of shop primer coat, providing temporary staging, scaffolding, testing etc., for steel structures at all levels and locations, all complete as specified.
Misc. Structural Steel Works(VCS-SS-CS-6026)
Supplying, transporting, storing, fabricating and fixing in position M.S. METAL INSERT (with lugs) of any shape made out of flats, plates, rolled sections, pipes etc. providing necessary templates, staging, cutting, straightening, if required, bolting, welding as required and embedding in position on both Plain and Reinforced Cement concrete members inclusive of adjusting shuttering & reinforcement/ any other fixture, welding where necessary, tying and holding to correct level, line and position, any auxilliary dummy structures to support the heavy inserts, painting exposed surfaces with a coat of primer as per Specification / BIS Codes etc. all complete for all depths and heights as specified and directed. ( SUPPLY OF ALL MATERIALS IN CONTRACTOR'S SCOPE).
Supplying, fabricating, fixing and keeping in position at all levels and locations THREADED ANCHOR BOLTS of all diameters and nomenclature including nuts, washers, anchor plates, pipe sleeves etc. in foundations, columns, pedestals, slabs, beams, walls etc. or any other place as directed including handling & transporting, straightening if required, turning from relevant size M.S. rounds to required diameter, threading, welding, providing necessary templates and auxilliary dummy structures, if any, necessary tying and welding with reinforcement, adjustment of shuttering & reinforcement/any other fixture, greasing exposed metal surfaces, covering bolts and packing the sleeves with jute cloth etc. all complete as specified and directed.(SUPPLY OF ALL MATERIALS IN CONTRACTOR'S SCOPE).
Supplying, fabricating and erecting in position at all levels and locations bolted, clamped and/or welded GRATING (fabricated as per drawings/ standards) made out of M.S. flats/M.S. flats with M.S. rounds in walkways, platforms, stair treads etc. including cutting to required size, shape, making holes, notches, openings of required size, nosing, straightening if required, making the edges smooth, removing the burrs, fabricating clamps, fixing, welding, preparation and submission of fabrication drawings and preparing the surfaces for galvanising, surface cleaning, wire brushing, removal of mill scale, dust, rust, oil or grease and GALVANISING as specified after fabrication etc. all complete as specified and directed (SUPPLY OF ALL MATERIALS IN CONTRACTOR'S SCOPE).
Supplying, fabricating and erecting in position at all levels and locations bolted, screwed and/or welded M.S. CHEQUERED PLATES of any thickness in walkways, platforms, stair treads, any other place as directed etc. including cutting to required size, shape, making holes, notches, openings of required size, nosing, straightening if required, making the edges smooth, removing the burrs, fixing, welding, preparation and submission of fabrication drawings and preparing the surfaces for painting and applying shop primer as per Specification / BIS Codes after fabrication etc. all complete as specified and directed. (ALL MATERIALS INCLUDING CEMENT SUPPLIED BY CONTRACTOR AT THEIR COST)
Supplying, fabricating and fixing in position at all levels & locations 1000mm high HAND RAILING (for platforms, walkways or any other location as directed etc.) consisting of top rail, mid rail and vertical posts (maximum spacing 1500mm c/c) with 32mm nominal diameter medium grade M.S. Tubes conforming to IS:1239 and M.S. Toe plates, including handling, transporting the same to site workshop and site of work, straightening if required, cutting, bending, notching, welding, bolting, grouting with ordinary grout, cleaning, surface preparation, shop primer as per Specification / BIS Codes,, preparation and submission of fabrication drawings etc. (ALL MATERIALS INCLUDING CEMENT SUPPLIED BY CONTRACTOR AT THEIR COST)). ( Complete handrail work shall be measured as length of top rail only and not length of each element fixed).
Steel & Aluminium Doors & Windows Work(VCS-SS-CS-6042)
Aluminium glazed doors with cup pivots of aluminium alloy to IS designation NS-4 of IS-737 and IS designation of A-5-M of IS- 617, Heavy duty hydraulically operated, adjustable floor mounted door closer conforming to IS:6315 (single/double action), 250mm and 150mm long,10mm dia anodized. Aluminium tower bolts as per IS : 204 one each for each shutter, brass body mortice lock (6 levers, as perIS : 2209) with aluminium handle on both sides, etc. all complete for each shutter, with plain anodized aluminium sections and 5mm thk. toughened glass as per IS:5437 .
Aluminium glazed window/ventilator with approved make sections, friction hinges, cast aluminium handle, etc. all complete.With plain anodized aluminium sections and 5mm thk. toughened glass as per IS:5437, Openable type.
Brick Masonary(VCS-SS-CS-6027)
Providing and laying BRICK MASONRY WITH BRICKS OF CLASS 7.5 in cement mortar 1:6 (1 Cement : 6 Sand) in one or more brick thickness and in any shape (excluding circular/curved brick masonry) at all depths and height including the cost of materials, labour, scaffolding/ staging, sampling & testing, soaking of bricks, cutting and laying of bricks, providing recesses, making openings of any shape & size, finishing the joints flush below ground level and raking out the joints above ground level, sealing the gap between masonry and soffit of beam/slab, embedding the fittings & fixtures, curing, etc. all complete as per specifications.
Providing and laying HALF BRICK MASONRY with bricks of CLASS 7.5 in cement mortar 1:4 (1 Cement : 4 Sand)in any shape, including the cost of materials, labour, scaffolding/staging, sampling and testing, soaking of bricks, cutting and laying of bricks, providing openings of any shape & size, raking out the joints, supplying and placing 2 Nos. 6mm dia. M.S. Bars at every fourth course, sealing the gap between masonry and soffit of beam/slab, embedding the fittings and fixtures, curing etc. all complete as per specification.ALL MATERIALS INCLUDING CEMENT SUPPLIED BY CONTRACTOR.
PLASTERING WORK(VCS-SS-CS-6043)
External Walls Plain cement plaster with waterproofing compound conforming to IS-2645 (CICO/ approved equivalent) mixed to cement mortar @ 3% by weight, Average 18mm thick 1:4 (1 cement : 4 sand) (ALL MATERIALS INCLUDING CEMENT SUPPLIED BY CONTRACTOR AT THEIR COST)
Internal Walls Ordinary plain cement plaster Average 12mm thick 1:4 (1 cement : 4 sand). (ALL MATERIALS INCLUDING CEMENT SUPPLIED BY CONTRACTOR AT THEIR COST)
Ceiling Ordinary plain cement plaster Average 6mm thick 1:4 (1 cement : 4 sand). (ALL MATERIALS INCLUDING CEMENT SUPPLIED BY CONTRACTOR AT THEIR COST)
Painting of External walls:- Providing & applying 3 coats of waterproof decorative cement paint of approved make and approved shade, cleaning, including preparation of surfaces,base primer, curing etc. all complete
Painting of Internal walls:- Providing & applying 2 coats of waterproof decorative cement paint of approved make and approved shade, cleaning, including preparation of surfaces,base primer, curing etc. all complete
Plumbing & Building drainage(VCS-SS-CS-6012)
Supplying and laying above ground mild steel galvanised pipes conforming to IS:1239 (heavy grade) and fittings conforming to IS:1239 (GALVANISED) and as per piping materials specification Class including supply of teflon tapes, white lead, etc. cutting the pipes to required lengths, making threads, including laying of pipes on sleeper, walls, including erecting piping on columns, etc. for pump station, overhead tanks, etc. including joining the pipes and fittings with threaded connections, hydrostatic testing of the piping including supply of necessary fittings etc & pipe supports. complete as per specifications, drawings and instructions of Engineer-in- Charge. For following:
( Nom. Dia 150 mm Pipe class - )
SEPTIC TANK(VCS-STD-CS-6004) Construction, supplying, installation, testing and commissioning of septic tank as per standards and IS:2470 Part-I , with all necessary accessories like inlet, outlet vent pipes, manhole covers, rungs etc. including earthwork in excavation in all type of soil except soft and hard rock, backfilling and disposal of surplus earth for all leads etc. complete as per standards, drawings, specifications and directions of Engineer-in-Charge. All material including cement supplied by contractor ( Users -10 NOS )
SOAK PIT(VCS-STD-CS-6003) Construction of soak pit conforming to IS:2470 Part-I and as per Standard, masonry, filling and hand packing brick bats of size ranging between 40mm to 50, connecting with septic tank with necessary fittings, piping etc.including excavation, back filling and disposal of surplus earth for all leads, complete as per drawings, specifications and directions of Engineer- in-Charge. for following users ( Users -10 NOS )
MANHOLE(VCS-STD-CS-6012/6013) Construction as per standard drawing of brick masonry (brick class shall be as mentioned below) inspection chambers/manholes of 750mmx750mm internal size 1000mm deep(Max.) in cement mortar 1:4 (1 cement: 4 sand) with CI frame and cover 500mm clear dia, (circular Medium duty of grade MD-10) conforming to IS:1726 fixed on RCC slab of M-30 grade, necessary excavation, supplying, fixing 4 Nos. 16mm dia M.S. rungs, M-20 grade foundation concrete 1:3 cement mortar(1 cement: 3 sand) plastering of 13mm average thickness for inside & 16mm avg. thickness for outside exposed surfaces, backfilling, disposal of surplus earth upto a lead of 100M, benching with M-20 grade cement concrete and rendering smooth with a neat coat of cement slurry, painting the C.I. frame and cover with two coats of chlorinated rubber zinc phosphate primer @ 40µ DFT per coat and finish painting consists of two coats of chlorinated rubber paint @40µ DFT per coat etc. all complete as per drawings, specifications and directions of Engineer-in- Charge.
Acid Proof Tiles Lining(VCS-SS-CS-6048)
Providing and laying acid resistant, vitrified tiles of approved size as per manufacturer's specs. in floor/ skirting/ Dado laid over and including bitumen priming layer, 12mm thick Bitumen mastic layer and 6mm thick resin type chemical resistant mortar conforming to IS: 4443 including raking out and flush pointing of joints with resin type chemical resistant mortar, preparation of back ground surface, finishing etc. all complete.
VITRIFIED TILES Providing and laying Vitrified tile flooring of size 600mm x 600mm of approved make (Marbonate or approved equivalent) set in cement slurry over 1:4 cement mortar bed of 35mm average thickness at all levels. Joints between tiling to be filled with grout of approved shade as per manufacturers specifications. Rate to include cost for laying tiles to approved pattern, design as directed by Architect, including surface cleaning, cement mortar, curing, acid wash, etc., and protecting the flooring with polythene sheet and pop overlay till hand over.
SKIRTING Providing and laying 10mm average thick vitrified tile skirting with 10 to 12 mm thick cement mortar (1:3)
NON SLIP VITRIFIED TILE DADOING
SANITARY WORKS
Cost of providing and fixing cera / hindware wall mounted EWC with power flush with seat cover etc, (Ivory colour) set in 1:2:4 concrete and doing necessary angles, connections.etc.,
Cost of providing and fixing wash basin of cera/hindware make (Ivory colour) fixed to existing wall using necessary angles, connections, including all SS accessories like waste coupling, bottle trap, inlet connection tube etc., complete.
HEALTH FAUCET Cost of providing and fixing Health faucet CP Jaquar are approved equivalent.
MIRROR Supplying and fixing mirror for wash basin of standard make as per standard specifications
Pillar Cock Cost of providing and fixing pillar cock long neck with aerator. Jaguar or approved equivalent fixed with necessary accessories.
Angular Stop Cock Cost of providing and fixing ½" dia Jaquar angle stopcock.
Concealed Stopcock Cost of providing and fixing concealed stopcock Jaquar or approved equivalent
C.P Trap Cost of providing and fixing C.P. cockroach trap, floor drains of Chilli / equivalent make
Nahani Trap Supplying and fixing approved quality heavy grade cast iron Floor/Nahani Trap with CP pressed steel grating including cutting floors and making good the same, etc., making inlet and outlet connections, etc. complete for 100mm inlet and 100mm outlet as per drawings, specifications and directions of Engineer-in-Charge.
SS jali Cost of providing and fixing SS Jali of Jaquar /equivalent make
Towel Rod Supplying and fixing Towel rod of standard make as per standard specifications
INTERNAL PLUMBING WORKS Internal Plumbing work P/f 1/2"consisting of CPVC or equivalent pipe and 50mm & 75mm dia. PVC Pipe outlet (prince or equivalent ) including G.I. & PVC assorted fittings, such as elbow,tees ,bends,& unions including applying creosote and wrapping with hessin cloth, including chasing the walls for concealing the pipe lines and making good the same. This includes providing & fixing 3/4" dia "C" class G.I. Pipe for inlet & outlet of Water Tank connection.
EXTERNAL PLUMBING WORKS
Providing & fixing of external plumbing consisting of CPVC or equivalent pipes varying from dia 3" to 6" with all fittings like bend, tees, gate valves, NRV's, y's etc which Nani traps,special pieces and accessories for laying joiniting including testing & commissioning of all Pantry/toilets.
Supply, transportation and erection of 500 liters SINTEX / Equivalent water tanks.
Concrete Pavement(VCS-SS-CS-6006)
Providing and laying Reinforced cement concrete with 20mm and down size graded crushed stone aggregates in flooring, pavements etc. including leaving pockets, if necessary, making recess/drains, laying in alternate panels, etc. for all depths including shuttering, tamping, curing, etc. as specified in any shape, thickness, position and finishing the top surface smooth etc. all complete as per drawings, specifications and directions of Engineer-in-Charge (excluding cost of providing and fixing reinforcement & joint sealing). For RCC of M-30 grade concrete (all materials including cement shall be supplied by contractor)
Sealing joint around pedestal and column etc. 20mm wide x 150 mm deep including filling with 20mm thick impregnated fire board for the full depth of slab except for 25mm depth from top and sealing the top 25mm with approved joint sealing compound as per IS:1834 Type-B.
ELECTRICAL
SUPPLY, INSTALLATION, TESTING & COMMISSIONING (SITC).
Design Installation, testing , supply and commissioning of following Painted/coated sheet steel enclosed switch boards, wall mounting, free standing cubicle type, including power and control cable glanding and terminations , handling, shifting from the owner’s store / storage yard to erection site, unpacking and inspection, dressing of foundation as required, assembly of panels, aligning, levelling, bus bar bolting, fixing in position on base channels grouted level in foundation floor or directly on level floor foundation by bolting etc., inter panel wiring and earth connections, mounting in position and wiring / connections of loose components / accessories e.g. relays, meters, CTs, PTs, etc., drilling of gland plates with required holes or enlargement of existing holes for cable entries, fixing of cable glands and terminals supplied loose, plugging of all unused cable entries and other holes in panels to make the same and the entire switchboard dust and vermin proof, minor repair and touch painting work, operational and functional checking, supply of foundations bolts, nuts and washers and other necessary hardware’s and civil masonry materials, all work, labour and materials complete as per drawings and documents, specification, codes and standards and direction of consultant / owner..
MEDB( Main Electrical Distribution Board Location -Dispatch Station)- Design Engineering, Manufacturing, assembly, inspection, testing at shop, packing and Supply, complete set of Electrical panel suitable for 415 Volt,160A, 3 phase neutral, 4wire 50Hz 25 kA,CU Bas- Bar ,fabricated in compartmentalized from CRCA sheet steel not less than 2mm thick duly treated with 7 tanks process, powder coated with approved shade and oven dried. The complete Electrical panels will have a short circuit with stand capacity of19 KA for 1 Second, IP 42 rating. The panel shall have a common copper earth bar Suitable size at the rear with 2 Nos. earth studs, Design as per drawings and documents, specification, codes and standards and direction of consultant / owner.(ref Key single line diagram-VC-7P23A-EL-SLD- 001 Sheet 1 attached. Feeder details are as follows- Incomming - 160A, 4PMCCB -2NOS + 1NOS 160A, 4PMCCB BUS-COUPLER Outgoing - 100A ,4P MCCB- 1 NOS 63A ,4P MCCB- 11 NOS 32A ,4P MCCB- 7 NOS 16 A ,4P MCCB- 12 NOS Outgoing Indoor lighting feeder shall be protected with suitble Rating ELCB
MEDB(Main Electrical Distribution Board Location -Receiving Station)- Design Engineering, Manufacturing, assembly, inspection, testing at shop, packing and Supply, Design of complete set of Electrical panel suitable for 415 Volt, 160A, 3 phase neutral, 4wire 50Hz, 25 kA,CU Bas- Bar, fabricated in compartmentalized from CRCA sheet steel not less than 2mm thick duly treated with 7 tanks process, powder coated with approved shade and oven dried. The complete Electrical panels will have a short circuit with stand capacity of 25 KA for 1 Second, IP 42 rating. The panel shall have a common copper earth bar Suitable size at the rear with 2 Nos. earth studs, Design as per drawings and documents, specification, codes and standards and direction of consultant / owner.(ref Key single line diagram-VC-7P24A-EL-SLD- 003Sheet 1 attached. Feeder details are as follows- Incomming - 160A, 4PMCCB -2NOS + 1NOS 160A, 4PMCCB BUS-COUPLER Outgoing - 100A ,4P MCCB- 1 NOS 63A ,4P MCCB- 11 NOS 32A ,4P MCCB- 12NOS 16 A ,4P MCCB- 16 NOS Outgoing Indoor lighting feeder shall be protected with suitble Rating ELCB
MEDB(Main Electrical Distribution Board Location -SV Station )-Supply, Design Engineering, Manufacturing, assembly, inspection, testing at shop, packing and Supply, Design of complete set of Electrical panel suitable for 415 Volt, 100A, 3 phase neutral, 4wire 50Hz,19 kA,CU Bas- Bar, fabricated in compartmentalized from CRCA sheet steel not less than 2mm thick duly treated with 7 tanks process, powder coated with approved shade and oven dried. The complete Electrical panels will have a short circuit with stand capacity of19 KA for 1 Second, IP 42 rating. The panel shall have a common copper earth bar Suitable size at the rear with 2 Nos. earth studs, Design as per drawings and documents, specification, codes and standards and direction of consultant / owner.(ref Key single line diagram-VC-7P25A-EL-SLD- 003Sheet 1attached. Incomming - 100A, 4PMCCB -1NOS& 63A, 4PMCCB -1NOS + 1NOS 100A, 4PMCCB BUS-COUPLER Outgoing - 63A ,4P MCCB- 9NOS 32A ,4P MCCB- 5 NOS 16 A ,4P MCCB- 2 NOS Outgoing Indoor lighting feeder shall be protected with suitble Rating ELCB
1 KW (-48)V AC to DC Converter :- Design Engineering, Manufacturing, assembly, inspection, testing at shop, packing and Supply of 1 nos (-48V ) DC ,1 KW (230 VAC to-48 V DC) converter . Incoming AC Supply shall be taped from 230V AC UPSDB .
0.5 KW (-48)V AC to DC Converter :- Design Engineering, Manufacturing, assembly, inspection, testing at shop, packing and Supply of 1 nos (-48V ) DC 0.5KW (230 VAC to-48 V DC) converter . Incoming AC Supply shall be taped from 230V AC UPSDB .
0.5 KW (-48)V AC to DC Converter :- Design Engineering, Manufacturing, assembly, inspection, testing at shop, packing and Supply of 1 nos (-48V ) DC 0.5KW (110 VAC to-48 V DC) converter . Incoming AC Supply shall be taped from Existing 110V AC UPSDB .
0.5 KW (24)V AC to DC Converter :- Design Engineering, Manufacturing, assembly, inspection, testing at shop, packing and Supply of 1 nos (24V) DC, 0.5 KW (230 VAC to 24 V DC) converter . Incoming AC Supply shall be taped from 230V AC UPSDB .
UPS System for RT -Design, Engineering, Manufacturing, assembly, packing and supply installation and testing at at manufacturer's premises and site of 2X100% Parallel Redundant 12.5 kVA UPS Including BYPASS with solid state voltage stabilizer for Bypass, suitable for input Power supply voltage of 320 V-460V AC TPN and 230 ± 1% output AC supply. PS.
UPS System for DT -Design, Engineering, Manufacturing, assembly, packing and supply installation and testing at at manufacturer's premises and site of 2X100% Parallel Redundant 5 kVA UPS Including BYPASS with solid state voltage stabilizer for Bypass, suitable for input Power supply voltage of 320 V-460V AC TPN and 230 ± 1% output AC supply..
UPS System for SV -Design, Engineering, Manufacturing, assembly, packing and supply installation and testing at at manufacturer's premises and site of 2X100% Parallel Redundant 3 kVA UPS Including BYPASS with solid state voltage stabilizer for Bypass, suitable for input Power supply voltage of 320 V-460V AC TPN and 230 ± 1% output AC supply.
Ni-Cd Battery For UPS RT :-Design, Engineering, Manufacturing, assembly, packing and supply installation and testing at site, of complete set of battery banks. The battery bank for UPS (12.5 KVA) shall be suitable for a backup of 4 hours and shall be split into 2 banks of 50% capacity each. The battery full (100%) bank shall be available to either of the UPS. Battery bank shall be sized as per IEEE-1115 with the following factors (a) Ageing factor of 0.8 (b) Design margin of 10% (c) Temperature derating for service at 35 degC. refer Single line diagram VC-7P23A-EL-SLD- 001, Sheet 2)attacheed.
Ni-Cd Battery For UPS DT :-Design, Engineering, Manufacturing, assembly, packing and supply installation and testing at site, of complete set of battery banks. The battery bank for UPS ( 5 KVA) shall be suitable for a backup of 4 hours and shall be split into 2 banks of 50% capacity each. The battery full (100%) bank shall be available to either of the UPS. Battery bank shall be sized as per IEEE-1115 with the following factors (a) Ageing factor of 0.8 (b) Design margin of 10% (c) Temperature derating for service at 35 degC. refer Single line diagraVC-7P24 A-EL-SLD- 001, Sheet 2)attached
Ni-Cd Battery For UPS SV :-Design, Engineering, Manufacturing, assembly, packing and supply installation and testing at site, of complete set of battery banks. The battery bank for UPS (3 KVA) shall be suitable for a backup of 24 hours and shall be split into 2 banks of 50% capacity each. The battery full (100%) bank shall be available to either of the UPS. Battery bank shall be sized as per IEEE-1115 with the following factors (a) Ageing factor of 0.8 (b) Design margin of 10% (c) Temperature derating for service at 35 degC. refer Single line diagra VC-P725A-EL-SLD- 001 Sheet 2)attached.
UPS DB (UPS Distribution Board Location - DT Station )-Supply, Design Engineering, Manufacturing, assembly, inspection, testing at shop, packing and Supply, Design of complete set of Electrical panel suitable for 230 Volt, 63 A, 2 phase 2 wire 50Hz,19 kA,CU Bas- Bar, fabricated in compartmentalized from CRCA sheet steel not less than 2mm thick duly treated with 7 tanks process, powder coated with approved shade and oven dried. The complete Electrical panels will have a short circuit with stand capacity of19 KA for 1 Second, IP 42 rating. The panel shall have a common copper earth bar Suitable size at the rear with 2 Nos. earth studs, Design as per drawings and documents, specification, codes and standards and direction of consultant / owner.(ref Key single line diagram-VC-7P23A-EL-SLD- 002Sheet 1attached. Incomming - 63A, 2P MCCB -1NOS Outgoing - 6A ,DP MCB- 12NOS 10A DP MCB- 3 NOS
UPS DB (UPS Distribution Board Location RT Station )-Supply, Design Engineering, Manufacturing, assembly, inspection, testing at shop, packing and Supply, Design of complete set of Electrical panel suitable for 230 Volt, 63 A, 2 phase 2 wire 50Hz,19 kA,CU Bas- Bar, fabricated in compartmentalized from CRCA sheet steel not less than 2mm thick duly treated with 7 tanks process, powder coated with approved shade and oven dried. The complete Electrical panels will have a short circuit with stand capacity of19 KA for 1 Second, IP 42 rating. The panel shall have a common copper earth bar Suitable size at the rear with 2 Nos. earth studs, Design as per drawings and documents, specification, codes and standards and direction of consultant / owner.(ref Key single line diagram-VC-7P24A-EL-SLD- 002Sheet 1attached. Incomming - 63A, 2 P MCCB -1NOS Outgoing - 6A ,DP MCB- 32NOS 10A ,DP MCB- 4 NOS
UPS DB (UPS Distribution Board Location -SV Station )-Supply, Design Engineering, Manufacturing, assembly, inspection, testing at shop, packing and Supply, Design of complete set of Electrical panel suitable for 230 Volt, 63 A, 2 phase 2 wire 50Hz,19 kA,CU Bas- Bar, fabricated in compartmentalized from CRCA sheet steel not less than 2mm thick duly treated with 7 tanks process, powder coated with approved shade and oven dried. The complete Electrical panels will have a short circuit with stand capacity of19 KA for 1 Second, IP 42 rating. The panel shall have a common copper earth bar Suitable size at the rear with 2 Nos. earth studs, Design as per drawings and documents, specification, codes and standards and direction of consultant / owner.(ref Key single line diagram-VC-7P25A-EL-SLD- 002Sheet 1attached. Incomming - 63A, 2 PMCCB -1NOS Outgoing - 6A ,DP MCB- 07 NOS 10A ,2P MCB- 2 NOS
Solar Power System -Supply, installation, testing, commissioning of Solar Power Package of 48V DC system (without battery banks) , Out going 230V system including Solar Panels (3KW X 2 no's), Solar Charger controller Panels( 6 KW, X 2 nos,) 7.5 kw inverter , Support Structuresr including all fixing arrangements, Civil Works and all material and labour as per specifications, drawings and instruction of EIC. Work to be completed in all respects. Design as per drawings and documents, specification, codes and standard and direction of consultant / owner.(ref Key single line diagram- VC-P725A-EL-SLD- 001 Sheet 2)attached. Including SITC.
Cabling system-Horizontal and vertical laying including terman, testing (before & after laying) and commissioning of following ,LV.(power ) / L.V.(control) Cu/ Al cables pre-fabricated cable trays/ racks, on already installed risers, supports, hangers, saddles etc pulling through pipes on walls/ columns, steel structures including transportation of cable drum from Owner's point of issue to the site, unrolling the drum, laying the required length of cables including supply and fixing of necessary G.I. saddles, saddle bars, cable tag, G.I. / Al clamps for cables laid vertical on walls/ columns/ structures, risers, trefoil clamps of appropriate size for single core cables, preferably of FRP or Polycarbonate material, etc. with all labour, consumable material and necessary hardwares to make installation complete in all respect as per approved standard drawings and direction of Engineer in charge. Scope includes excavation, backfilling, providing sand and bricks in cable trenches including supply of FLP , double compression Nikel plated Cable Glands & lugs also including excavation and supply of soft /hard soil with backfilling. Complete in all respect as per items detail below-
3CX4 CU XLPE Including SITC.
3CX6 CU XLPE Including SITC.
4CX6 CU XLPE Including SITC.
4CX10 CU XLPE Including SITC.
4CX50 CU XLPE Including SITC.
4CX16 AL XLPE Including SITC.
4CX50AL XLPE Including SITC.
4CX25 AL XLPE Including SITC.
3.5CX95 AL XLPE Including SITC.
3CX2.5 CU XLPE Including SITC.
1x70 mm2 CU PVC UNARMOURED flexible HRFR Cable (fo rcharger to battery )
3CX2.5 (FLEXIBLE WIRE) Including SITC.
EARTHING & LIGHTNING SYSTEM :
Design of, installation/laying, testing, supply commissioning of Earthing with maintenance free Chemical earthing system copper (cladding of 250 micron thickness) electrode low carbon steel 3.0 Mtr. long and 38 mm dia , environmentally friendly earth enhancement back fill compound (25 Kg CPRI test report is required) and copper clamp for earthing arrangement including accessories, and providing masonry enclosure with cover plate having locking arrangement as required. Scope includes Supply, installation, testing and commissioning.
Supply and Laying of 50mm X 6 G.I strip complete with all accessories. Including SITC.
Supply and Laying of 25mm X3 mm GI strip complete with all accessories. Including SITC.
Supply and Laying of 16 mm2 Insulated copper wire earthing complete with all accessories. Including SITC.
Supplying and Laying of 10 sq. GI Wire Earthing complete with all accessories Including SITC.
Supply and Laying of G.I Earth Bus bar complete with all accessories. Including SITC.
Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.
PLANT / STREET LIGHTING POLES & Light fittings :- Supply, Erection & commissioning of following hot dipped galvanised mild steel tubular swaged / lighting poles installation of junction Box, cable connection, necessary hardware's, earthing, supply of paint & painting with all labour & consumable materials to make installation complete with horizontal arm or swan neck as per drawing , direction of Engineer-in-charge.
Supply of street light pole Hexagonal 8 M high GI with FLP JB and cable from JB to fixture ,complete in all respects suitable for Hazardous Zone-2 area. Including SITC.
Supply of street light pole Hexagonal 4.5 M high GI with FLP JB and cable from JB to fixture ,complete in all respects suitable for Hazardous Zone-2 area. Including SITC.
Power socket:- Supply, Installation, testing & commissioning of following type of Junction boxes including transportation from owner's issue point to the site of erection & all labour & material to make installation complete in all respect as per instruction, approved drgs, specifications & direction of Engineer-in-charge. Including SITC.
Welding Receptical with 63A Power socket, Ex'd' type Junction box (Outdoor) complete with 3 nos. entry. 1 no. Incoming cable glands suitable for 1 Run 3 Core 50 Sq.mm AL, XLPE insulated Armoured Cable & 2No. outgoing cable glands suitable for 3.5CX50sq.mm Al, XLPE Armoured cable with 1 nos. threaded plug. Including SITC.
Supplying and fixing 16 amps, 240 volts, SPN, FLP Ex'd' type switch socket outlet, with 2 poles and earth metal enclosed plug top along with 16 amps.rotary switch in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet, and complete with connections, testing and commissioning etc. as required.
Indoor wiring /other materials:- Supply, Installation, testing & commissioning(SITC).
EXHAUST FAN300MM (Flameproof ) (for Battery room) Including SITC.
Wiring for light point (upto10 meter) with 2.5 sq. mm FRLS PVC insulated copper conductor three core cable/wire in surface/ recesses steel conduit in roof & PVC conduit in wall, with modular switch (AHOSXXW061/101 or equivalent), modular plate, suitable GI box and earthing the point with 2.5 sq.mm.FR PVC insulated copper conductor three core standard cable/ wire etc as required. Including SITC.
Wiring for Fan point (upto10 meter) with 2.5 sq. mm FRLS PVC insulated copper conductor three core cable/wire in surface/ recesses steel conduit in roof & PVC conduit in wall, with modular switch (AHOSXXW061/101 or equivalent), modular plate, suitable GI box and earthing the point with 2.5 sq.mm.FR PVC insulated copper conductor three core standard cable/wire etc as required. Including SITC.
Wiring for FLP 300 mm dia Exhaust Fan point (upto10 meter) with 2.5 sq. mm FRLS PVC insulated copper conductor three core cable/wire in surface/ recesses steel conduit, with modular switch (AHOSXXW061/101 or equivalent), modular plate, suitable GI box and earthing the point with 2.5 sq.mm.FR PVC insulated copper conductor single/ three core cable/wire complete with FLP Junction box. etc as required. Including SITC.
Wiring for power plug(Up to 10 meter) with 4X4 sq. mm FRLS PVC insulated copper conductor cable in surface/ recessed medium class PVC conduit along with 1 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core standard cable/wire for loop earthing as required. Including SITC.
GI box suitable for 6 way modular plate+4 nos modular switches+1 nos 5/15A scoket ( SITC)
Wiring for Submain/Circuit wiring (rates for above 10 meter wiring ) along with earth wire with the following sizes of PVC insulated, copper conductor single /two /three core cable/wire in surface/ recessed steel conduit as required.
2X2.5 sq. mm + 1X2.5 sq. mm Earth wire. Including SITC. If required.
2X4 sq. mm + 1X4 sq. mm Earth wire. Including SITC. If required.
2X6.0 sq. mm + 1X6 sq. mm Earth wire. Including SITC. If required.
2X10.0 sq. mm + 1X10 sq. mm Earth wire. Including SITC. If required.
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
25 mm MS Conduit Including SITC. If required.
Conduit boxes, 1 way . Two ways, 4 ways Including SITC. If required.
Supply and Fixing of Ceiling Fan of 1200mm sweep complete erected in position with all accessories with Fan box Including SITC.
2 TON ,5 star AC with 32A MCB BOX (energy efficient ) Including SITC.
Supply and fixing of 300 mm dia Exhaust Fan with louvers complete in all respects.( For Toilets) Including SITC.
OUTDOOR LIGHT FITTINGS : Supply Installation, connection, testing & commissioning of prewired FLP LED / LED Well Glass/ LED street lighting fixtures along with integral/non-integral control gears, lamps, tubes, chokes, starters, condensers, mounting accessories, earthing, junction boxes etc. including supply of all connecting materials like clamps, support, conduit, down rods etc. as required as well as transportation from owner's issue point to site of erection with all labour & material to make installation complete in all respect as per drawing, & direction of Engineer-in-charge.
Supply of street light Fixtures FLP 80/100 W FLP LED , for Mounting on 8M light GI Hexagonal pole mounted Industrial light fixture complete in all respects suitable for Hazardous Zone-2 area. Including SITC.
Supply of process Area light Fixtures FLP 100/125 W FLP LED ,Mounting on 4.5M lightGI pole mounted Industrial light fixture complete in all respects suitable for Hazardous Zone-2 area. Including SITC.
Supply of wall / ceiling mount Fixture 1x 40/36 W LED Industrial light fixture complete in all respects.( indoor type) Including SITC.
Supply of wall / ceiling mount FLP Fixture 1x 40/36 W LED Industrial light fixture complete in all respects.( indoor type) Including SITC.
Supply of wall / ceiling mount Fixture 1x 18 W LED Industrial light fixture complete in all respects.( indoor type) Including SITC.
SUPPLY& installation OF CABLE TRAYS :- Installation of pre- fabricated Perforated type G.I. cable trays & horizontal/ vertical bends & regular tees 2mm thickness of various sizes on already erected supports or risers, including joining various cable trays by bolting with G.I. bolts, nuts and washers as per approved drawings(including fixing J - hooks, reducer coupler plate, adjustable coupler plate) as per the desired cable route and as per the drawings and direction of Engineer-In-charge .
450mm wide Ladder Including SITC.
300 mm wide Ladder Including SITC.
150 mm wide Ladder Including SITC.
75 mm wide Ladder Including SITC.
Installation of cable route markers along the cable route at an interval of 30M as well as at cable bends and joints. Including SITC.
FABRICATION OF STEEL STRUCTURE .
Supply, Fabrication & installation of M.S. frame supports & brackets for various equipment base frame, misc. electrical equipment support, made of channels, angles, flats etc. of different sections including bolting, welding, riveting, supply of necessary anchor bolts & grouting etc. including 2 coats of zinc rich anti rust epoxy primer & 2 finish coats of epoxy paint including breaking wall, floor etc. & making good the same with all labour & consumable materials to make installation complete in all respect as per approved drgs, specification & direction of Engineer-in-charge. Including SITC.
STEEL PIPES:- supply, Installation of GI Steel pipes of following sizes for cable protection, floor sleeves etc. fixed on a steel structure, concrete, laid in trenches, to be buried in etc. to a clamp, nuts, bolts, sockets, reducer, spacer, plug, bushing, chirping of concrete floor, breaking of concrete cable trench, walls & complete with labour & materials as per direction of Engineer-in-charge.
50mm (2" dia) Including SITC.
75mm (3" dia) Including SITC.
100mm (4” dia) Including SITC.
EXCAVATION AND BACK FILLING:- Excavation and back filling of earth pits, street light pole and earth strips etc. following types of soil except rock for a maximum depth of 1.25 mtrs for cables and for earth strips including shoring, strutting, dewatering, consolidation and disposal of surplus earth up to 100 mtrs leads including all labour, materials to complete installation work in all respect.
Soft soil
Hard soil
STREET LIGHT POLE CONCRETE FOUNDATION :-Street light pole installation includes Concrete foundation (ratio of cement: sand: stone = 1:2:4 with RCC as per STD drawings) Including SITC.
EARTH PIT CHAMBER (Civil works with required civil materials) :- Excavation of soil up to required depth , and back filling up to the pit with layers of charcoal and salt including supply of the same providing necessary brick/ concrete works and other civil work. Including SITC.
SAFETY MATERIALS (Including SITC.)
Supply and installation of following types of caution boards written in English and in Local language.1.1KV/415 Kv Including SITC.
Supply , installation of Shock Treatment Chart written in English and local language duly framed and approved by Engineer-in-charge Including SITC.
First Aid Boxes containing all the medical items as per approved international Red Cross Society or by govt. medical authority. Including SITC.
Safety posters as issued by the local Government Safety Council in English and local languages. Including SITC.
CO2 fire extinguisher(4.5 kg) Including SITC.
Sand Bucket with stand. Including SITC.
INSTRUMENTATION
Supply, Calibration and Installation of instrumentation items listed below: (For details, refer instrumentation datasheets & specifications) & P&ID
Supply and installation of Pressure Gauge as per Installation standard,specs,data sheets & P&IDs. Supply, Calibration, Installation and Commissioning of Bourdon type with diaphragm seal, direct mount, 150mm dial, wetted part SS316, IP 65rated, blow out protection and shatter proof heavy duty glass. Inclusive of supply and installation of necessary as per installation standard and specifications.
Supply and installation of Temperature Gauge as per Installation standard,specs,data sheets & P&IDs. Supply, Calibration,Installation and Commissioning of Bi- metallic type temperature gauge, direct mount, 150mm dial. Also supply of erection of 1.5" 600# thermowell of suitable insertion length. Inclusive of supply and installation of necessary accessories as per Datasheet, P&ID and Standard Specification
Supply and installation of Temperature Indicating Transmitter as per Installation standard,specs,data sheets & P&IDs. Supply, Calibration, Installation and Commissioning of Smart HART, Ex'ia', IP-65 rated, 24 VDC 2-wire loop powered Temperature Transmitter along with, RTD Element with screwed head, 1.5" 600# flanged Thermowell of suitable insertion length. Inclusive of supply and installation of necessary accessories as per the data sheet, standard specification, standard installation and P&ID attached with this tender
Supply and installation of Temperature Indicating Transmitter as per Installation standard,specs,data sheets & P&IDs. Supply, Calibration, Installation and Commissioning of Smart HART, Ex'ia', IP-65 rated, 24 VDC 2-wire loop powered Temperature Transmitter along with, Skin type Temperature Element. Inclusive of supply and installation of necessary accessories as per the data sheet, standard specification, standard installation and P&ID attached with this tender
Supply and installation of Pressure Indicating Transmitter as per Installation standard,specs,data sheets & P&IDs. Supply, Calibration, Installation and Commissioning of Smart HART, Ex'ia', IP-65 rated, 24 VDC 2-wire loop powered, direct mount diaphragm seal type double isolation valves with flush ring Pressure Transmitter. Inclusive of supply and installation of necessary accessories as per the datasheets, standard specifications, standard installation drawings and P&ID attached with this tender.
Supply and installation of Differential Pressure Indicating Transmitter as per Installation standard,specs,data sheets & P&IDs. Supply, Calibration, Installation and Commissioning of Smart HART, Ex'ia', IP-65 rated, 24 VDC 2-wire loop powered, Differential Pressure Transmitter along with diaphragm seal type double isolation valves and flush ring. Inclusive of supply and installation of necessary accessories, standard specifications, standard installation drawings and P&ID attached with this tender.
Supply and installation of Coriolis Mass Flow Meter (Non-Custody type): as per Installation standard,specs,data sheets & P&IDs. Supply, Calibration, installation and testing of Coriolis Mass Flow Meter (Non-Custody type) and their accessories inclusive of supply of necessary accessories and installation as per datasheets, standard specifications, standard installation drawings and P&ID attached with this tender.
Supply and installation of Thermal dispersive type Flow switch: : as per Installation standard,specs,data sheets & P&IDs. Supply, Calibration, installation of Thermal dispersive type Flow Switch and their accessories inclusive of supply of necessary accessories and installation as per datasheets, standard specifications, standard installation drawings and P&ID attached with this tender.
Supply and installation of Errosion Probe( Flush Disc Type) : as per Installation standard,specs,data sheets & P&IDs. Supply, installation of ER Probes (Flush disc type) and their accessories inclusive of supply of necessary 2" Access fittings including cabling, termination, glanding, and dressing, mounting as per datasheets, standard specifications, standard installation drawings and P&ID attached with this tender.
Supply and installation of Corrosion Coupon ( Flush Disc Type) : as per Installation standard,specs,data sheets & P&IDs. Supply, installation of Corrosion Coupons (Flush disc type) and their accessories inclusive of supply of necessary 2" Access fittings as per datasheets, standard specifications, standard installation drawings and P&ID attached with this tender.
Supply ,Laying, Glanding & Termination of 1P X 1.5 Sq. mm, Flame retardant,Individual Screened(Blue) Cables
Supply ,Laying, Glanding & Termination of 6P X 1.5 Sq. mm, Flame retardant,Individual & Overall Screened Cables(Blue)
Supply ,Laying, Glanding & Termination of 12P X 1.5 Sq. mm, Flame retardant,Overall Screened Cables(Black)
Supply ,Laying, Glanding & Termination of 12P X 15 Sq. mm, Flame retardant,Individual & Overall Screened Cables(Blue)
Supply & Installation of Analog Junction Boxes
Supply & Installation of Digital Junction Boxes
Supply ,Laying, Glanding & Termination of 4P X 1 .5 Sq.mm, Flame retardant, Over all Screened Cables(Black)
Supply ,Laying, Glanding & Termination of 1P X 1.5 Sq. mm, Flame retardant, Over all Screened (Black) Cables
Supply & Installation of erection hardwares like needle valve, Gauge Cock, SS Tubes, Fittings 2-valve manifold, 3-valve manifold, stand pipes brackets, nuts & bolts, clamps, Cable Glands, Cable lugs, ferruls, Met Block etc. as required
Supply & Installation of Cable Trays of width X length (100mm X 50mm)
Supply & Installation of Cable Trays of width X length (300mm X 50mm)
Supply & Installation of Erection & Commissioning Spares
Supply & Installation of Cable Trays of width X length (450mm X 50mm)
Supply & Installation of F&G Devices as per requirement Supply & Installation and commissioning of following F&G devices such as Gas Detectors, Beacons, Hooters and MCP. Laying of cable inside the cable trench, cable tray for hardwired signals and power cables from gas sensors to gas detectors control unit including glanding, termination, ferruling, dressing etc. at both ends. Installation and erection of cable trays and, supply of erection materials, cable ferrules, cable lugs, cable tie.
Point Gas Detector - IR type, 4-20 mA HART, 3 wire 24 VDC loop powered flame proof, IP-67, housing material SS316 without display.
Open Path Gas Detector UV / IR type, 4-20 mA HART, electronic 24 VDC to transmitter, 24VDC loop powered to receiver, flame proof, IP-67, housing material SS316 without display.
Flame Detector IR3 Type, 4-20 mA HART, electronic 24 VDC to transmitter, 24VDC loop powered, IP-67, housing material SS316
Supply and installation of Hooter outdoor Hazardous area application complete with wiring and accessories
Beacon Xenon Discharge Lamp, 24 VDC, IP67, Enclosure MOC- Cast aluminium (LM6).(outdoor/hazardous area application)
Manual Call Point break glass type with nickel plated brass hammer & SS Chain , 24 VDC, IP67, Enclosure MOC- LM6 (shade 536 of IS-5) [ FIRE RED], EOL resistor, outdoor hazardous area application
Gas Detection Panel (GDS Panel)- Control Room in DabiDubi Receiving Terminal & Crude Receipt Terminal Supply, Installation, Testing and Commissioning of Gas Detection Panel (GDS Panel)
Fire Alarm Control Panel (FACP) - Control Room in Dabidubi Receiving Terminal Supply, Testing, Installation, Erection and Commissioning of FACP including Detectors, MCP, Hooter, Panel and Cables. FACP shall be of wall mounted type and installed in Control Room. Supply, Laying of cable inside Room between Detectors, MCP, Hooter and FACP including glanding, termination, ferruling, dressing etc. at both ends. Supply & installation of cable trays (if necessary), supply of erection materials, cable ferrules, cable lugs, cable tie etc. for successful commissioning of FACP.
Fire Alarm Control Panel (FACP) Supply and Installation of Addressable type Fire Alarm Control Panels (FACP) installed in Receiving Terminal Control Room complete with battery backup and accessories, interfaces with RTU and inclusive of Cabling, Installation, Testing and Commissioning
Supply and installation of Addressable Multi Sensor (Smoke+Heat) complete with wiring and accessories
Supply and installation of Manual Call Point Indoor complete with wiring and accessories
Supply & Installation of Beacon (Indoor Application)
Supply and installation of Hooter indoor complete with wiring and accessories
Supply & Installation of Cables, Cables Trays and Junction boxes Supply, laying, installation, erection of signals cable from field instruments to junction boxes including termination, ferruling, dressing etc. Supply of cable trays, cables glands, junction boxes, erection materials, cable ferrules, cable lugs, cable tie. Installation and Erection of cable trays and junction boxes.
2C X 1 .5 Sq. mm, Fire Resistant,Over all Screened
8C X 1 .5 Sq. mm, Flame Resistant, Over all Screened
6T X 1 .5 Sq. mm, Fire Resistant,Individual Screened, Over all Screened
1T X 1 .5 Sq. mm , Fire Resistant,Individual & Over all Screened
12T X 1 .5 Sq. mm , Fire Resistant,Overall Screened
Digital Fire Junction Box(24 TB)
Analog Fire Junction Box( 48 TB)
Analog Fire Junction Box( 12 TB)
Cable Trays (100 mm wide x 50 mm height), Perforated Type
Cable Trays (450 mm wide x 50 mm height), Perforated Type
Cable Trays (300 mm wide x 50 mm height), Perforated Type
Erection & Commissioning Spares
Erection hardwares
Supply, Calibration and Installation of instrumentation items listed below: (For details, refer instrumentation datasheets & specifications) & P&ID
Supply and installation of Pressure Gauge as per Installation standard,specs,data sheets & P&IDs. Supply, Calibration, Installation and Commissioning of Bourdon type with diaphragm seal, direct mount, 150mm dial, wetted part SS316, IP 65rated, blow out protection and shatter proof heavy duty glass. Inclusive of supply and installation of necessary as per installation standard and specifications.
Supply, installation & Testing of Pressure Indicating Transmitter as per Installation standard,specs,data sheets & P&IDs. Supply, Calibration, Installation and Commissioning of Smart HART, Ex'ia', IP-65 rated, 24 VDC 2-wire loop powered, SIL-2 rated, direct mount with 2-valve manifold.
Supply, Installation & commissioning of Restriction Orifice as per Installation standard,specs,data sheets & P&IDs. Supply, testing, installation & commissioning, one each of 1" & 2" size in detection line & fire water line with accessories in accordance with datasheet, specifications & P&ID.
Supply & installation of Quartz bulbs (1" or 1/2"size as per calculation) in detection line with accessories in accordance with datasheet, specifications & P&ID
Supply,cable termination , Commisioning & Testing of Deluge valve Pneumatic actuator, as per P&ID. Spring Return, Single Acting Actuated valve of size 6", 150# and their accessories inclusive of supply of necessary piping/tubing , tube fittings, including cabling, glanding, termination, earthing etc.
Supply and Installation 1/2” SS tubing for Deluge valve Actuator from the nearest instrument header with NRV (1/2" size) & other necessary fittings,as required.
Supply and Installation of Air Filter Regulator (AFR), 1" size, as per P&ID, specification & data sheet; Supply, installation, calibration, testing and commissioning of Constant bleed type Air Filter Regulator, 1" process connection, 10 kg/cm2 (max.) Inlet Pressure 0-8 kg/cm2 (contineous) & set at 3kg/cm2g regulated pressure, 5 micron Filter element size, Sintered Bronze filter element material, mettalic bowl material, with drain (Automatic/manual), IP65 enclosure protection, enclosure material die cast aluminium along with all required accessories and 1" pressure gauge.
Supply and Installation of Air Accumulator with Capacity of 25 Ltr & 1" Process connection size, as per P&ID, specification & data sheet; Supply, installation, calibration, testing and commissioning of Air Accumulator with associated accessories like PSV, PG, Drain valve with plug with necessary tube & tubes fittings..
Supply & Installation of Cables, Cables Trays, cables glands and Junction boxes , including termination, ferruling, dressing etc as follows:
Junction Box -Analog Junction Box, IP -65 Ex"d", 48 Terminals.
Supply of 1P x 1.5 Sq.mm, ‘IS’ Overall Screen Cable shall be of XLPE.CS.PVC.SWA.PVC/ Flame retardant / Blue
Supply of 6P x 1.5 Sq.mm, ‘IS’ Individual and Overall Screen Cable shall be of XLPE.CS.PVC.SWA.PVC/ Flame retardant / Blue
Supply of 6P X 1.5 Sq.mm ‘NIS’ Twisted Pair, overall screen shall be of XLPE.CS.PVC.SWA.PVC/ Flame retardant/ Black
Cable Trays (100 mm wide x 50 mm height), FRP Type with necessary supports and other accessories.
Cable Trays (300 mm wide x 50 mm height), FRP Type with necessary supports and other accessories.
Cable glands, lugs, ferrules etc. as required.
Erection Hardwares for installation of Instruments/ Items etc. as required.
Tolani Projects Pvt. Ltd. (BID ID -3165263)
North East Engineering n Construction (BID ID -3161603)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.06 MB
Download all tender documents and submit your bid