Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹30.1 LAccepted-AOC | L-1 | Accepted-AOC Being L-1 | |
| 2 | L-1₹31.3 LRejected-Finance | L-1 | Rejected-Finance other than L-1 | |
| 3 | L-3₹39.0 LRejected-Finance | L-3 | Rejected-Finance other than L-1 | |
| 4 | L-4₹39.9 LRejected-Finance | L-4 | Rejected-Finance other than L-1 |
Tender Value
₹28.5 L
EMD Value
₹57,000
Closing Date
25 Nov 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Sh A K Dubey, IDSE , SE CWE
Military Engineer Services, Commander Works Engineer, Udhampur, PO - Garhi, Udhampur-182121
CONSTRUCTION OF SEPRATE OFFICE FOR MGGs (IW) AND ASSOCIATED STAFF AT HQ NC UNDER GE (SOUTH) UDHAMPUR
2021_MES_478952_1
CWE/U(S)-58/2021-22
Open Tender
Construction Works
Lump-sum
180 days
Udhampur
AS PER TENDER
8 documents required · 8 mandatory
₹500
GE (South) Udhampur
₹57,000
Yes
6 Jan 2022
30 Sept 2021
27 Nov 2021
30 Sept 2021
25 Nov 2021
13 Nov 2021
60 days
Amount
BUILDING WORK (SCHEDULE 'A' PART-I) Lump sum price worked out by the Contractor for “Building Work” as listed in Schedule ‘A’ Part- I.
Internal Water Supply (SCHEDULE 'A' PART-II) Lump sum price worked out by the Contractor for “Internal Water Supply” as listed in Schedule ‘A’ Part- II .
INTERNAL ELECTRIFICATION (SCHEDULE 'A' PART-III)(SEC-I) Lump sum price worked out by the Contractor for “Internal Electrification” as listed in Schedule ‘A’ Part- III (Sec-I)
INTERNAL ELECTRIFICATION (SCHEDULE 'A' PART-III) (SEC-II) SCHEDULE `A' PART-III, Sec-II is not prepriced by MES and prepriced rates indicates 0.0 under column 5 signified this fact only. Bidder shall insert their rates in Green filed under Col-6.
Environmental friendly, new generation,aesthetically designed, ultra modern, glare-free symmetric light distribution SURFACE mounting luminaire with high efficiency long life LED integral module as light source, 36 Watt 2'x2' LED flat Panel luminire with SELV Output electronic LED driver (SMPS based constant current supply) complete making connection and testing after fixing including making good disturbed surface all as specified and directed by Engr-in-charge.The specification of light fitting should meet the following : - (a) Housing of Light fitting : CRCA powder coated (b) Diffuser : High transmittance polystyrene opal diffuser (c) Operating Voltage : 150 V- 270V (d) Operating Temperature : -10 to +45 Degree Centigrade (e) Lumen efficacy : Not less than 100 lm/W (f) System Lumens : Not less than 3600 lm (g) Colour Temperature : Not less than 5700K (h) Surge Voltage Protection : Up to 2KV (j) Ingress protection : IP 20 (k) Total Harmonic Distortion (THD) : Not less than 20% (l) Power factor : Not less than : 0.9 (m) Line protection : Under/Over voltage Protection (n) Input Frequancy : 50 Hz (o) Dimension of fitting : (600 x600 x 50)mm
Aesthetically designed 1x1 LED flat 18 Watt panel for surface mounting with high efficiency long life LED integral module as light source, Slim type independent Isolated,SELV Output electronic LED driver (SMPS based constant current supply) complete making connection and testing after fixing including making good disturbed surface complete all as specified and directed by Engr-in-charge. The specification of light fitting should meet the following : - (a) Housing of Light fitting : Aluminium Die Cast/Extruded aluminium (b) Diffuser : High transmittance opal Diffuser (c) Operating Voltage : Between 150 V- 270V (d) Operating Temperature : -10 to +45 Degree Centigrade (e) Lumen efficacy : Not less than 100 lm/W (f) System Lumens : Not less than 1800 lm (g) Colour Temperature : Not less than 5700K (h) Surge Voltage Protection : Up to 2KV (j) Ingress protection : IP 20 (k) Total Harmonic Distortion (THD) : Not less than 20% (l) Power factor : Not less than : 0.9 (m) Line protection : Under/Over voltage Protection (n) Input Frequancy : 50 Hz (o) Dimension of fitting : (300 x300 x 70)mm
Decorative ultra slim linear surface mounted LED lighting fixture (4 feet length), 18/20Watt LED with integral electronic driver complete making connection and testing after fixing all as specified and directed by Engr-in-charge.The specification of light fitting should meet the following : - (a) Housing of Light fitting : Aluminium Extruded (b) Operating Voltage : Between 150 V- 270V (c) Operating Temperature : -10 to +45 Degree Centigrade (d) Lumen efficacy : Not less than 110 lm/W (e) System Lumens : Not less than 2000 lm (f) Colour Temperature : Not less than 5700K (g) Surge Voltage Protection : Up to 2KV (h) Ingress protection : IP 20 (j) Total Harmonic Distortion (THD) : less than 20% (k) Power factor : Not less than : 0.90 (l) Line protection : Under/Over voltage Protection (m) Input Frequancy : 50 Hz
Decorative ultra slim linear surface mounted LED lighting fixture (1 feet length), 5 Watt LED with integral electronic driver complete making connection and testing after fixing all as specified and directed by Engr-in-charge.The specification of light fitting should meet the following : - (a) Housing of Light fitting : Polycarbonate/Thermoplastic (b) Operating Voltage : Between 150 V- 270V (c) Operating Temperature : -10 to +45 Degree Centigrade (d) Lumen efficacy : Not less than 90 lm/W (e) System Lumens : Not less than 450 lm (f) Colour Temperature : Not less than 6500K (g) Surge Voltage Protection : Up to 2KV (h) Ingress protection : IP 20 (j) Total Harmonic Distortion (THD) : Not less than 20% (k) Power factor : Not less than : 0.9 (l) Line protection : Under/Over voltage Protection (m) Input Frequancy : 50 Hz
New generation energy saving and environmental friendly long life LED street light of 25 watt with high power LED as lighting source and lens embedded PC cover having TOP OPENING seperate driver compartment and impact resistance of IK07 with High efficiency long life LED with SMD LED on MCPCB Powered by Built-in, isolated electronic LED driver (SMPS based constant current supply) complete making connection and testing after fixing, complete all as specified and directed by Engr-in-charge. The specification of light fitting should meet the following : - (a) Housing of Light fitting : Aluminium Die Cast (b) Diffuser : High efficient LENS Optics (c) Operating Voltage : Between 150 V- 270V (d) Operating Temperature : -10 to +45 Degree Centigrade (e) Lumen efficacy : Not less than 100 lm/W (f) System Lumens : Not less than 2500 lm (g) Colour Temperature : Not less than 5700K (h) Surge Voltage Protection : Up to 4KV (j) Ingress protection : IP 65 (k) Total Harmonic Distortion (THD) : Not less than 20% (l) Power factor : Not less than : 0.9 (m) Line protection : Under/Over voltage Protection (n) Input Frequancy : 50 Hz
Ceiling fan AC single phase 230/240 volts of size 1200 mm sweep , having service value > 4.0 including making connection with and including suitable flexible copper wire, complete all as specified and as directed by Engineer-in-Charge.
Exhaust fan 300mm sweep metallic, 230 Volts, including louvers, complete all as specified and directed by Engr-in-Charge.
MCB SP 6 to 32 Amps ( ISI Marked) 50 C/S 10 KA 'B' sereis complete all as specified.
MCB SPN, 40 to 63 Amps, 240 Volts, rupturing capacity 10 KA "B" Series including providing aluminuium thimbles for outgoing cable, complete all as specified and as directed by Engr-in-Charge. Note : The exact capacity of MCB shall be as directed by Engr-in-Charge.
Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.0mm thick buried directly in ground, (Earth pit not less than 2.25 mtr deep below ground level) with top edge of plate not less than 1.5 mtr below normal ground level, connected to and including 4 mm dia galvanised earth lead wire by means of bolts, nuts, check nuts and washers of galvanised standard iron or steel all as specified or indicated in electrical plate no 3 of MES Part-I, including testing on completion including the material and labour of the following :- (a) Excavation and earth work for drilling hole for electrode in any type of soil. (b) PCC pit in cement concrete 1:2:4 type B-1. (c) Precast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than 1.87 Kg/Sqm. (d) Funnel with watering pipe of GI 20 mm nominal bore medium grade and copper lugs etc all as specified. (e) 15 mm nominal bore light grade GI protection pipe 5 mtr long for protection of earthing lead from mechanical injury or tempering. (f) Requisite quantity of common salt and charcoal. (g) Testing of earthing. Note : (a) On testing after completion of earthing, if the desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk and cost to the entire satisfaction of the Engineer-in-Charge.
AC in hi wall split unit air conditioner reversible type five star rating indoor and outdoor unt complete with cordless remote control unit and with built air ionise and plasma filter for better indoor air quality capacity 2 Ton with standard assessores induding MS framework installation of outer wall side, including making required hole in wall for passing of cooling pipe/ cable and making good damaged portion of wali/ floor/ roof in CM 1:4 complete as directed.
Voltage stabilizer for automatic operation, single phase copper wiring naturally air cooled indoor type & designed for input votage 170 to 250 V output voltage 230 V. With accuracy +0.25% and capacity 7.5KVA .
Sub Total
PATH (SCHEDULE 'A' PART-IV) Lump sum price worked out by the Contractor for “PATH” as listed in Schedule ‘A’ Part- IV .
EXTERNAL ELECTRIFICATION (SCHEDULE 'A' PART-V) Lump sum price worked out by the Contractor for “External electrification” as listed in Schedule ‘A’ Part- V .
EXTERNAL ELECTRIFICATION (SCHEDULE 'A' PART-V) (SEC-II) SCHEDULE `A' PART-V, Sec-II is not prepriced by MES and prepriced rates indicates 0.0 under column 5 signified this fact only. Bidder shall insert their rates in Green filed under Col-6.
Supply, installation , testing and commissioning wall mounted type , weather proof , LT Panel board made out of 3.15 mm thick CRCA steel sheet front openable , double door openable up to minimum 180 (degree) , removable type having magnetic catcher system , lockable / openable by keys from both sides having chromium plated locks , louvers and air vent gaskets for natural air flow suitable for 3 phase 4 wire 415 volts 50 Hz factory fabricated with suitable foamed - in PU gasket to make it dust / vermin proof IP 54 protection , Powder coated and prewired as per standard engineering practice , the panel manufacturer should have got any one of the panel tested at CPRI earliest for short circuit current of 50 KA for one second and similar design and technology shall be adopted for fabrication of panel copy of CPRI test report shall be produce to GE along with a certificate from manufacturer of the panel that the similar design and standard have followed in these panels complete, suitable cable glands for cable entry . The panel shall be suitable to accommodate the following equipments:-
Srl item No 7.01 Contd.... (a) Alumninium bus bar of capacity duly covered with colour coded shrinkable sleeves not less than 200 Amps for Phases and neutral - 01 set (b) Panel instrumental wiring with FRLS suitable size but not less than 2.5 sqmm copper wire single core - 01 Job (c) Panel indicating lamp neon / LED type ( Red, Yellow & Blue ) with lamp holders - 03 Nos
Srl item No 7.01 Contd.... (d) MCCB 4 pole, Ics = 100% lcu - 25/26 KA , 415 Volts , 100 Amps , with thermal adjustable and fixed magnetic setting with extended terminals - 01 No Note - Size of LT Panel shall not be less than 900x600 mm. The panel should have hanging arrangement on the wall . The cost of complete hanging arrangement & making good the surfaces as per existing one shall deemed to be included in the unit rate quoted for this item .
Taking out the existing unserviceable LT Panel and Supply, installation , testing and commissioning of outdoor type , weather proof , LT panel board made out of 3.15 mm thick CRCA steel steet mounted on 60 cm long legs made out of 40x 40x 6mm equal angle, embedded in PCC 1:2:4 type B1 blocks of size 15x15x15 cm, front and back openable, double door openable up to minimum 150 (degree) , removable type having magnetic catcher system , lockable / openable by keys from both sides having chromium plated locks , louvers and air vent gaskets for natural air flow suitable for 3 phase 4 wire 415 volts 50 Hz factory fabricated with suitable foamed - in PU gasket to make it dust / vermin proof IP 54 protection , Powder coated and prewired as per standard engineering practice , the panel manufacturer should have got any one of the panel tested at CPRI earliest for short circuit current of 50 KA for one second and similar design and technology shall be adopted for fabrication of panel copy of CPRI test report shall be produce to GE along with a certificate from manufacturer of the panel that the similar design and standard have followed in these panels complete, suitable cable glands for cable entry .
Srl item No 7.04 Contd.... Outgoing : ( a ) MCCB 4 pole , Ics = 100 % Icu - 35/36 KA , 415 Volts , 200 Amps , with thermal adjustable and fixed magnetic setting with extended terminals -02 Nos . (b) MCCB 4 pole, Ics = 100% lcu - 25/26 KA , 415 Volts , 160 Amps with thermal adjustable and fixed magnetic setting with extended terminals -02 Nos . (c) MCCB 4 pole, lcs = 100% lcu- 25/26 KA. 415 Volts , 100 Amps , with thermal adjustable and fixed magnetic setting with extended terminals -01 No . (d) PCC 1 : 3 : 6 type C - 2 for grouting 4 legs of feeder pillar box. Note :- Various feeder shall be indicated by 50 mm high letter in white synthetic enamel paint.
Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below ground level connecting to galvanised iron earth strip 32 x 6mm by means of bolts,check nuts and washers and earth strip protected by provision of GI pipe light grade 40mm bore including provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded crushed stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4 KG/Sqm) and frame of angle iron 25 X 25 X 3mm with lugs 2 Nos and with 6mm dia MS bar handle made to shape, GI medium grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge plate, common salt and charcoal filling, connecting to test point with fixing arrangement, funnel, wire mesh and earth work in any type of soil,returning filling in and removal of surplus soil to a distance not exeeding 50 mtr, all as per electrical plate No 3 of SSR 2009 Part-I all as specified and testing on completion. Note :- Cost of GI earth strip & protection pipe upto 7.5 mtr is deemed to be included in unit rate.
Sub Total
SEWAGE DISPOSAL (SCHEDULE 'A' PART-VI) Lump sum price worked out by the Contractor for “Sewage Disposal ” as listed in Schedule ‘A’ Part- VI
AREA DRAINAGE (SCHEDULE 'A' PART-VII) Lump sum price worked out by the Contractor for “ Area Drainage” as listed in Schedule ‘A’ Part- VII
PROTECTIVE WORK (SCHEDULE 'A' PART-VIII) Lump sum price worked out by the Contractor for “Protective Work” as listed in Schedule ‘A’ Part- VIII
EARTH WORK AND SITE CLEARANCE (SCHEDULE 'A' PART-IX) Lump sum price worked out by the Contractor for “Earth work and site clearance” as listed in Schedule ‘A’ Part- IX .
joginder singh and sons
RAMAN CONSTRUCTION CO
s l sharma and sons
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .