Loading…
Loading…
Tender Value
₹31.4 Cr
EMD Value
₹41.4 L
Closing Date
3 Aug 2026, 3:30 pm
Executive Engineer, BUILDING DIVISION GOPALGANJ
EE
EE, Building Division Gopalganj, BCD
Superintending Engineer, Building Circle Chapra
SE
Construction of Faculty/Staff Quarter in Govt. Polytechnic College Gopalganj. Tender ID - 135557
135752
Re-NIT-10/ET/BCD/GOPALGANJ/2026-27
Open Tender
CIVIL
Gopalganj
• ALL INFORMATION IS TO BE FILLED IN REMARK FIELD
• (a) Unconditional bank guarantee from any scheduled Indian bank issued within the state in the format given. 16.1
Bid Security Amount in Rupees Total Bid Security Amount in Rupees 4140000.00 IFB
• (i) Legal Status of Bidder (select from drop down list) 4.3(a)
(ii) Place of Registration. (select from drop down list)
(iii) write Principal place of Business.
• (iv) Power of attorney of signatory Bid (select from drop down list) 4.2(iv)
• Total value of civil engineering construction work, in Rupees, Performed in last five years.
minimum annual financial turnover (in all classes of civil engineering construction works only) amount of construction work of at least the equal to the 50 % of estimated cost of works for which bid has been invited. The turn over will be indexed at the rate of 8% for a year i.e Rs 156973731.00
2021-22
2022-23
2023-24
2024-25
2025-26
• Amout in Rupees related to Work Experience of Similar nature Satisfactory completed at least one similar work of value not less than 50% of estimated Cost 156973731.00 4.5(A) (b)
• Minimum Quantities of work done as prime contractor in any one year during last five years, units shall be same as in Requirement column Items Qty Unit 4.5A( c)
E/W 12547.99 cum
BRICK WORK 1556.33 cum
PCC / RCC 2783.57 cum
STONE AND TILES FLOORING 6461.27 sqm
FIRE FIGHTING Rs. 5952578.00
PLUMBING WORKS Rs.5054946.00
FURNITURE Rs.0.00
Electric Work Rs. 13133775.00
• Electrical License The contractor or his identified sub-contractor should possess required valid electrical license for executing the building electrification works and should have executed similar electrical works for a minimum amount as indicated in Appendix in any one year 4.5A( d)
• (a) Amount of Existing commitments and ongoing works in Rupees Sec 2-1.4(A)
• (b) Amount of Work for which Bid already submitted, in Rupees Sec 2-1.4(B)
• Numbers and Maximum age of Equipments with bidder Type of Equipment Nos. Maxm. Age Sec 2-1.5
Concrete Batching and Mixing Plant Minimum Capicity 15 Cum Per Hour 1 5Y
Vibrator (Plate & Niddle) 5 5Y
Water Tanker 2 5Y
Transit Mixture 1 5Y
Pump for concreting 1 5Y
Steel shuttering 10000 sft
• Name of the Personnel and Experince in years and Select from drop down list Personnel / Qualification 4.5(B) (b)
Project Manager/ B.E. Civil + 10 Years Exp. (5 years as Manager having MBA) or equivalent or retired E.E. 1
Plant Engineer/ B.E. Mech./ Civil + 03 Years Exp. or Dip. Mech + 05 Years Exp. or Retired J.E. 1
Site Engineer/ B.E. (Civil) + 03 Years Exp. (3 years in Building Construction) or Diploma in Civil + 7 year Exp. In Building construction or retired A.E. 2
Quantity Surveyor/ B.E. Civil + 03 Years Exp. or Dip. Civil + 05 Years Exp.. 1
Site Supervisor /Fresh Graduate in Civil or Diploma Civil + 02 Years Exp. or retired I.T.I Holder. 3
• Evidence of accesses to Financial Resources in Rupees Evidence of access to or availability of creadit facilities (10% of estimated cost), certified by bankers (for work under this bid). 4.2(i)
• Proposed methodology and programme of construction Select from drop down list the proposed methodology and programme of construction, backed with equipment planning and deployment 4.3(l)
• Litigation History. Select from drop down list. Information regarding any litigation, current or during the last five years, in which the Bidder is involved, the parties concerned, and disputed amount. (Attached or not) 4.3(j)
• Affidavit Select from drop down list. Regarding statements made in the required attachments are true and correct. Sec-2, Affidavit
• Undertaking Select from drop down list. Able to invest a minimum of cost upto 25% of contract value of work. During implementation of contract. Sec-2, Undertaking
• Time of Completion in months 15 Months
• Registration No.
• IT.& ST Registration & clearance Certificate
• Labour License
• Character Certificate.
• NOC for Debar (If required)
• Financial reports for the last five years: balance sheets, profit and loss statements, auditors' reports (in case of companies/corporation), etc. With Mention the UDIN No. on each Documents. as per Departmental Vide Lt. No. 7974 Dt 09-11-2022 List them below and attach copies.
• Bank Solvency certificate
• Joint Venture > 10 Cr
CIVIL
PERCENTAGE
L1
1
24 documents required · 24 mandatory
₹10,000
Processing Fee: 11800
₹41.4 L
SE Building Circle Chhapra
10 Jul 2026
10 Jul 2026
5 Aug 2026
11 Jul 2026
3 Aug 2026
11 Jul 2026
18 Jul 2026
TECHNICAL BID EVALUATION SHEET
BUILDING CONSTRUCTION DEPARTMENT
NAME OF WORK :- CONSTRUCTION OF FACULTY QUARTER FOR GOVT.POLYTECHNIC COLLEGE,SIPAYA,DISTT-GOPALGANJ, BIHAR
B.O.Q. AMOUNT :- 313947461.00
SL.NO. PARTICULARS LAID DOWN CRITERIA AS PER NIT CONDITION FULL MARKS EVALUATION CRITERIA BIDDER
A Name and address of agency
B Registration no. & department Agency must be registered with Govt./State Govt./Undertakings Mandatory Agency must be registered otherwise bid will be rejected
C Sale tax/VAT/GST clearance of Govt. of Bihar Must possess sales tax/VAT registration & up to date clearance certificate Mandatory ---do------
D Income Tax clearance Must quote PAN No. Mandatory ---do------
E Earnest Money In the form as specified in N.I.T and required amount. Mandatory ---do------
F Character Certificate Must Posses Character Certificate. Mandatory ---do------
G Electrical Registration In the form as specified in N.I.T and required amount. Mandatory ---do------
Note:-The bidders should necessarily be Responsive on above mentioned Seven counts A to G. The bidders found Non-Responsive in any one of the above mentioned Seven counts will not be considered for further markings & their Bid will be rejected.
MARKING DETAILS
SL.NO. PARTICULARS LAID DOWN CRITERIA AS PER NIT CONDITION EVALUATION CRITERIA
FULL MARKS Desired distribution
1 Average annual financial turn over of last three years (AATO may be indexed as per norms of bidding documents) Submit A.T.O of Chartered account ant for last three years 30 i) AATO equal to or above BOQ amount--30
ii) AATO equal to or above 70%of BOQ amount--20
iii) AATO equal to or above 50% but below 70% of BOQ amount--15
iv) AATO equal to or above 40% but below 50% of BOQ amount--10
v) AATO equal to or above 25% but below 40% of BOQ amount--5
vi) AATO below 25% of BOQ amount--Nil
Average A.T.O.after indexation
2 Experience of doing work of similar nature Must submit details of work done duly certified by the concerned E.E 20 i)If executed single work of similar nature equal to 50% of BOQ amount-20
ii)If executed single work of similar nature equal to 40% of BOQ Amount----15
iii)If executed single work of similar nature equal to 25% of BOQ Amount----10
iv)If executed single work of similar nature below 25% of BOQ Amount----nil
3 Details of Engineering setup for successful completion of work Must submit details Engg. Setup with individual affidavit of engineers. 10 i)Engg.setup with one-Deg.holder+one Diploma holder+suff.. staff--10
ii)Engg.setup with1-Deg.holder/one Diploma holder+suff. staff--5
4 Plant and equipment for successful completion of work i)Automaticbatching plant with all equipment. (ii)Conc.mixer with weighing facility. (iii)Steelshuttering & centering more than 2000sft. (iv)Vibrator & water tanker. 10 i)Atomatic Batching plant with all equipment---10
(ii)Concrete mixer with weighing facility---04
(iii)Steel shuttering and centering more than 2000sft--04
(iv)Vibrator------01
(v)water tanker----01
5 Details of financial availability through bank or self Bank certificate of extending credit facility up to 10% of BOQ amount 10 i)credit facility certificate given by Indian Bank upto 10%of BOQ amount-----05
(ii)Self declaration----05
(iii)No Self declaration----00
6 Necessary undertakings Agency should furnish the following undertakings. (i)Not abandoned project. (ii)No litigation. (iii)No relation. 5 (i)Not abandoned any project--03
(ii)No litigation--01
(iii)No relation---01
(iv)Not submitted any certificate---00
7 Bidding capacity BC=AxNx2-B A=Max.ATO after indexation. B=value of work in hands(Existing commitment) N=Time of completion Attach bidding statements with details 10 i)BC more than or equal to BOQ amount--10
iI)BC more than or equal to 70%but below BOQ amount--5
iI)BC more than or equal to 50%but below 70% of BOQ amount--3
iii)BC below 50% of BOQ amount----nil
8 Timely completion of project Attach certificate of the concern E.E 5 i)If three or more than three projects executed in stipulated time during last five year--05
i)If less than three projects executed in stipulated time during last five year--03
i)If no projects executed in stipulated time during last five year--00
Note:- (i) Minimum qualifying marks = 50/100 for project b/w 40lakhs to 200lakhs
BILL OF QUANTITY
BUILDING DIVISION GOPALGANJ
Name of Work- CONSTRUCTION OF FACULTY QUARTER FOR GOVT.POLYTECHNIC COLLEGE,SIPAYA,DISTT-GOPALGANJ, BIHAR
BOQ Amount :- 313,947,461.00 BOQ issued to:-
Earnest Money :- Address :-
Cost of B.O.Q :- Reg. No :-
Time of Completion :-
Date of tender :- Signature of issuing of
S.N S.O.R Code Description of Work Unit QUANITITY Rate (Rs.) Amount (Rs.)
1 1.1/ 2.8 Earth work in excavation over areas (exceeding 30 cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m ; disposed earth to be levelled and neatly dressed.
2.8.1 All kinds of soil cum 6,661.31 360.70 2402735.00
2 2.6 Earth work in excavation over areas ( exceeding 30 cm in depth. 1.5 m in width as well es 10 sqm on plan) including disposal of excavated earth , lead upto 50 m and lift upto 1.5 m; disposed earth to be levelled and neatly dressed. 0.00
2.6.1 AH Kinds of soil Cum 1,902.27 314.90 599025.00
3 1.2/ 2.27 Extra for every additional lift of 1.5 m or part thereof in : 0.00
4 1.3/ 2.26 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth : consolidating each deposited layer by ramming and watering lead. cum 5,009.96 123.90 620734.00
5 1.4/ 2.28 Supplying and filling in plinth with local sand and under floors including, watering, ramming consolidating and dressing complete. cum 3,557.34 287.30 1022024.00
6 1.5/ 2.33 Clearing grass and removal of the rubbish upto a distance of 50 m outside the periphery of the area cleared 100sqm 2,243.5600 357.20 8014.00
1.6/ 2.29.1 Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead upto 50 m and lift upto 1.5 m 100sqm 2,243.56 1,355.40 30409.00
2.0 Concrete Work 0.00
7 2.1/ 4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level. 0.00
2.1.1/ 4.1.3 1:2: 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cum 773.48 3,998.10 3092450.00
8 2.2/ 4.12 Extra for Providing and mixing water proofing material in cement concrete work in the proportion recommended by the manufactures. per 50 kg cement 3,180.00 57.16 181769.00
3.0 Reinforced Cement Concrete Works 0.00
9 3.1/ 5.33 Providing and laying in position ready mixed or site batched design mix cement concrete(M-25) for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana /Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate /retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. 0.00
a a 3.1.1/ 5.33.1.1 All work upto plinth level cum 1,441.93 5,063.40 7301068.00
b b 3.1.2+3.1.3/5.33.2.1 All work above Plinth level upto floor V Level cum 3,215.28 5,863.20 18851830.00
10 3.2/ 5.22 Reinforcement for RCC work including straightening. Cutting, bending, placing in position and binding all complete. 0.00
Thermo-Mechanically Treated bars 0.00
11 3.3/ 5.9 Centring and shuttering including strutting, propping etc. and removal of form for: 0.00
a 3.3.1/ 5.9.1 Foundations, footings, bases of columns, etc., for mass concrete. sqm 2,049.73 211.60 433723.00
b 3.1.2/ 5.9.2 Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. sqm 324.56 375.10 121742.00
c 3.3.3/ 5.9.20 Suspended floors, roofs, landings, balconies and access platform with water proofply 12 mm thick. sqm 6,789.92 544.60 3697790.00
d 5.9.5 Lintels, beams, plinth bams, griders, bressumers and contilevers. sqm 58.80 404.70 23796.00
5.9.3 Suspended floors, roots, landings, balcnies and access platform. sqm 665.76 437.50 291270.00
e 3.3.3.1/5.11.1 Extra for additional height in centring, shuttering wherever required with adequate bracing, propping etc. including cost of de-shutering and de centring at all levels over a height of 3.5 m ,for every additional height of 1 metre or part thereof (Plan area to be measured) sqm 1,874.46 174.00 326156.00
f 3.3.4/ 5.9.4 Shelves (Cost in situ) sqm 2,179.68 437.50 953610.00
g 3.3.5/ 5.9.21 Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick sqm 10,386.68 518.90 5389648.00
h 3.3.6/ 5.9.6 Columns, Pillars, Piers, Abutments, Post and struts sqm 8,130.90 494.40 4019917.00
i 3.3.7/ 5.9.7 Stairs, (excluding landings) except spiral staircases. sqm 1,170.18 439.90 514762.00
j 3.3.8/ 5.9.13 Vertical and Horizontal fins individually or forming box louvers band, facias ane eaves boards. sqm 1,571.24 646.70 1016121.00
k 3.3.9/ 5.9.19 Wheather shade, Chajja, corbels etc., including edges. sqm 2,244.34 550.90 1236407.00
l 3.3.10/ 5.9.16 Edges of slabs and breaks in floors and walls : 0.00
Under 20 cm wide Metre 4,562.92 130.20 594092.00
4.0 Brick Work 0.00
12 4.1/ 6.1C Brick work with fly ash bricks as per IS 12894(2002) & IS 3495 in foundations and plinth in : 0.00
a 4.1.1/ 6.1.14C Cement mortar 1:6 (1 cement: 6 coarse sand ) - 250 mm th Brick work cum 752.42 4,923.00 3704164.00
b 4.1/ 6.1C Brick work with fly ash bricks as per IS 12894(2002) & IS 3495 in foundations and plinth in : 0.00
6.1.12C Cement mortar 1.:4 (1 cement: 4 coarse sand ) Cum 17.50 5,116.30 89535.00
c 4.2.1/ 6.1.14C+6.3C Brick work with fly ash bricks as per IS 12894(2002) & IS 3495 in superstructure above plinth level upto floor V cum 0.00
Cement mortar 1:6 (1 cement: 6 coarse sand ) - 250 mm th Brick work cum 1,725.73 5,765.20 9949179.00
d 4.2.2/ 6.1.12C+6.3C Half brick Masonary Cement mortar 1.:4 (1 cement: 4 coarse sand ) - 125 mm th Brick work cum 634.50 5,958.50 3780668.00
5.0 Wood Work 0.00
13 5.1/ 9.21 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type,core of block board construction with frame of 1 st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 0.00
5.1.1/ 9.21.1 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws sqm 1,398.60 1,775.30 2482935.00
14 5.2/ 9.118 Providing and fixing to existing door frames. 0.00
15 9.118.3 25 mm thick PVC flush door shutters made out of a one piece Multi chamber extruded PVC section of the size of 762mm X 25 mm or less as per requirement with an average wall thickness of 1 mm (± 0.3 mm). PVC foam end cap of size 23x10 mm are provided on both vertical edges to ensure the overall thickness of 25 mm. An M.S. tube having dimensions 19 mm x 19 mm and 1.0 mm (± 0.1 mm) is inserted along the hinge side of the door. Core of the door shutter should be filled with High Density Polyurethane foam. The Top & Bottom edges of the shutter are covered with an end-cap of the size 25mm X 11 mm. Door shutter shall be reinforced with special polymeric reinforcements as per manufacturer’s specification and direction of Engineer-in-charge to take up necessary hardware and fixtures. Stickers indicating the locations of hardware will be pasted at appropriate places. sqm 327.60 2,450.50 802784.00
5.3/ 9.119 Providing and fixing factory made P.V.C. door frame of size 50x47 mm with a wall thickness of 5 mm,made out of extruded 5 mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos. of 150 mm long brackets of 15x15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19x19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as per manufacturer’s specification and direction of Engineer-in-Charge. M 1,029.60 379.40 390630.00
16 5.4/ 9.96 Providing and fixing aluminium sliding door bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete: 0.00
17 5.5/ 9.97 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ), transparent or dyed to required colour or shade, with necessary screws etc. complete: 0.00
18 5.6/ 9.100 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete: 0.00
19 5.7/9.98 Providing and fixing aluminium pull bolt lock, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour and shade, with necessary screws bolts, nut and washers etc. complete each 786.00 78.40 61622.00
20 5.8/ 9.101 Providing and fixing aluminium hanging floor door stopper anodized (anodic coating not less than grade AC 10 as per IS :1868) transparent or dyed to required colour and shade with necessary screws etc. complete. 0.00
9.101.2 Twin rubber stopper each 594.00 60.80 36115.00
21 5.8/ 9.23 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of shutters (overall area of door shutter to be measured) Sqm 1,398.60 401.40 561398.00
22 5.9/ 9.40 Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs, and priming coat on unexposed surface etc. complete. 0.00
9.40.1 2nd class teak wood 0.00
23 5.10/ 9.169 Providing and fixing 19mm thick both side balancing lamination factory pressed BWP grade marine ply as per IS 710 of approved brand boxes, shelves, racks, almirah, cupboard and drawer etc. including necessary nails, screws etc. complete as per direction of Engineerin- charge. Sqm 328.50 2,490.60 818162.00
24 19.15 Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design : 0.00
19.15.1 With 20x20 mm square bar Each 432.00 310.90 134309.00
6.0 Steel Work 0.00
25 6.1/ 10.12 Providing and fixing ISI marked steel glazed door, windows and ventilators of standard rolled steel section & joints mitered and welded with 15x3 mm lugs, 10cm long with steel lugs embedded in cement concrete blocks 15x10x10 cm of 1 : 3 : 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawls plugs and screws or with fixing clips or with bolts and nuts as required, including providing and fixing of glass panes with glazing clips and special metal sash putty of approved make complete including applying a priming coat of approved steel primer, but excluding the cost of steel beading and other fittings except necessary hinges or pivots as required. sqm 901.08 3,038.90 2738292.00
26 6.2/ 10.15 Providing and fixing pressed steel door frame confirming IS code 351 manufactured from commercial mild steel sheet of 1.25 mm thickness including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50 x 25 mm or base ties of 1.25mm pressed mild steel welded or rigidly fixed together by mechanical means, adjustable lugs with split end tail to each jamb including steel butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-Charge. 0.00
27 6.3/ 10.18 Providing and fixing circular/hexagonal cast iron or M.S sheet box for ceiling fan clamp 140 mm internal dia, 73 mm height, 5 mm thick rim bottom and top lids, 1.5 mm thick M.S sheet with its top surface hacked for proper bonding top lid shall be screwed into the cast iron box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamps shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. each 686.00 165.40 113464.00
28 6.4/ 10.32 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes,channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, ( for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts,fasteners etc.). kg. 11,586.90 546.80 6335717.00
29 6.5/ 10.29 Providing and fixing bright finished brass peg stays 300 mm long of minimum weight 330 gms.to side hung steel windows with necessary welding and machine screws etc. complete. each 2,380.00 182.70 434826.00
30 6.6/ 10.38 Providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows all complete with. 0.00
10.38.2 5.5 mm thick glass panes. Sqm 759.60 1,179.10 895644.00
31 6.7/ 9.48 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. all complete. 0.00
9.48.1 Fixed to steel windows by welding kg. 18,252.16 144.50 2637437.00
32 6.8/ 10.3 Providing and fixing in position collapsible steel shutters with vertical channes 20x10x2 mm and braced with flat iron diagonals 20x5 mm size with top and bottom rail of T-tron 40x40x6 mm with 40 mm dia steel pulleys complete with bots.nuts locking arrangement stoppers handies including applying a priming coat of approved steel primer. each 87.30 6,303.40 550287.00
33 6.9/ 10.5 Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3mm MS gusset plates at the junction and corners.all necessary fittings completejncluding applying a priming coat of approved steel primer 0.00
10.5.1 Using M.S. angle 40x40x6 mm for diagonal braces sqm 28.98 3,653.00 105864.00
7.0/ Aluminium Works 0.00
34 6.10/ 9.76 Providing and fixing curtain rods of 1.25 mm thick chromium plated brass plate, with two chromium plated brass brackets fixed with C.P. Brass screws and wooden plugs, etc., wherever necessary complete 0.00 0.00
6.0 Aluminium Work 0.00
35 6.10/21.1 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash asteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / aneling,C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : 0.00
21.1.2.2 For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Kg 10,879.70 480.20 5224432.00
36 21.3 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): 0.00
21.3.2 With float glass panes of 5.50 mm thickness(weight not less than 12.50 kg/sqm) Sqm 1,264.74 1,115.10 1410312.00
37 21.4 Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with doublespring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors,embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete asper the direction of Engineer-in-charge. 0.00
21.4.2 With brass cover plate minimum 1.25 mm thickness Each 36.00 2,444.30 87995.00
38 21.8.1 Filling the gap in between aluminium frame & adjacent RCC/ Brick/Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. M 3,777.60 85.20 321852.00
39 S-8737 stainless steel wire guage (Grade-304) aperture 1.4 mm and 0.50 mm dia wire Sqm 558.10 537.263 299846.00
7.0 Flooring Works 0.00
40 7.1/ 11.72 Providing designation 100 A one brick flat soling joints filled with local sand including cost of watering taxes, royalty all complete as per building specification and direction of E/I. sqm 6,970.59 283.30 1974768.00
41 5/ 11.73 (BCD SOR 22) Providing designation 100 A one brick on edge soling joints filled with local sand including cost of watering, taxes, royalty all complete as per building specification and direction of E/l, 1,903.20 444.80 846543.00
42 7.2/ 11.26 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of 1:1:1 (1 lime : 1 surkhi : 1 coarse sand) / 1:4 (1 cemnt : 4 coarse sand) 0.00
43 7.3/ 11.27 Kota stone slabs 25 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement : 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. Sqm 432.23 1,334.90 576984.00
7.4/ 11.31 Extra for pre finished nosing in treads of steps of Kota stone / sand stone slab. metre 1,026.00 82.90 85055.00
7.5/ 11.32 Extra for Kota stone / sand stone in treads of steps and risers using single up to 1.05 metre.length Sqm 267.30 18.10 4838.00
44 7.6/ 11.37 Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturer) of ist quality conforming to IS : 15622 of approved make in colours such as white , Ivory , Grey , Fume Red , Brown , laid on 20 mm thick Cement motar 1:4 (1 cement: 4 coarse sand ) including pointing the joints with white cement and matching pigment etc., complete Sqm 779.20 686.80 535155.00
45 7.7/ 11.36 Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (Thickness to be specified by the manufacture) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer -in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Motar 1:3 (1cement : 3 coarse sand ) and jointing with grey cement slurry @ 3.3 kg per sqm including pointing in white cement mixed with pigment of matching shade complete. sqm 3,218.04 795.00 2558342.00
46 7.8/11.41 Providing and laying vitrifed floor tiles in different sizes {thickness to be specified by the manufactruer) with water absorption's less than 0.08 % and conforming to IS : 15622 of approved make in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand ) including grouting the joint with white cement and matching pigments etc., complete Sqm 5,598.92 1,638.80 9175510.00
11.41.2 Size of Tile 60x60 cm in floors 0.00
47 7.9/11.46 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete. Sqm 1,130.54 1,191.80 1347378.00
11.46.2 Size of Tile 600 x 600 mm. 0.00
48 7.10/8.2 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size,approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups,including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Sqm 282.70 2,458.00 694877.00
8.2.1.1 Area of slab over 0.50 sqm. 0.00
49 7.11/8.5 Extra for providing opening of required size & shape for wash basins/kitchen sink in kitchen platform. Vanity counters and similar location in marble/granite/stone work including necessary holes for pillar taps etc. including rubbing,moulding and polishing of cut edges etc. complete. Each 104.00 428.20 44533.00
50 8.0 Plaster & Finishing Works 0.00
a 8.1/ 13.11 12 mm cement plaster of mix 0.00
b 8.1/ 13.11 12 mm cement plaster of mix 0.00
c 8.2/ 13.12 15 mm cement plaster on rough side of single or half brick wall of mix. 0.00
51 8.3/ 13.18 15 mm cement plaster 1:3 (1 cement: 3 coarse sand ) finished with a floating coat of neat cement on the rough side of single or half brick wall. sqm 717.24 229.30 164463.00
52 8.4/ 13.24 6 mm cement plaster to ceiling of mix. 0.00
53 8.5/ 13.80a.2 Providing and applying white cement based putty of average thickness 2 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. sqm 46,307.98 105.40 4880861.00
54 8.6/ 13.77 Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade. 0.00
13.77.2 New work (two or more coats) over and including priming coat with cement primer. sqm 36,352.00 102.30 3718810.00
8.7/ 13.81 Applying priming coat: 0.00
55 8.7.1/ 13.81.1 With ready mixed pink or grey primer of approved brand and manufacture on woodwork (hard and soft wood) sqm 1,573.43 39.70 62465.00
56 8.8/ 13.93 Painting with synthetic enamel paint of approved brand and manufacture to give an even shed. 0.00
13.93.1 Two or more coats on new work sqm 4,228.73 84.50 357328.00
57 8.9/ 13.116 Forming groove of uniform size from 12 x 12 mm and upto 25 x 15 mm in plastered surface as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repairs to the edges of plaster panel and finishing the groove complete as per specifications and direction of the Engineer-in-charge. Metre 3,484.10 47.10 164101.00
58 8.10/ 13.26 Neat Cement punning Sqm 3,131.20 40.50 126814.00
59 13.31.1 Rough cast plaster with a mixture of sand and gravel or crushed stone from 2.36 to 12.5 mm nominal size dashed over and including the fresh plaster in two layers, under layer 12 mm cement plaster 1:5(1 cement:5 coarse sand ) and top layer 10 mm cement plaster 1:3(1 cemeht;3 coarse sand) mixed with 10% finely grounded hydrated lime by volume of cement: Sqm 142.80 393.00 56120.00
8.11/ 13.46 Finishing walls with Acrylic Smooth exterior paint of required shade : 0.00
60 13.46.1 New work (Two or more coat applied @ 1.67 Ltr/10 sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/10 sqm) Sqm 11,888.46 137.00 1628719.00
61 8.12/ 13.37 Extra for plastering walls of height more than 10m form groun level for every add it. Irate height of 3 or part there of Sqm 3,426.20 44.40 152123.00
9.0 Water Proofing Treatment Works : 0.00
62 9.1/ 22.3 Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed protions of W.C. kitchen and the like consisting of : 0.00
i) 1st course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. 0.00
ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. 0.00
iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg per sqm of area. 0.00
iv) IVth course of 400 micron thick PVC sheet (overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm Sqm 452.32 480.60 217385.00
63 9.2/ 22.8 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations : 0.00
64 a) Applying and grouting slurry coat of neat cement using 2.75 kg/sqm. of cement admixed with proprietary water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300mm height including cleaning the surface before treatment. 0.00
65 b) Laying cement concrete using broken bricks/brick bats 25 mm to 100 mm size with 50% of cement mortar 1:5 (1cement : 5 coarse sand) admixed with proprietary water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1cement :5 coarse sand) admixed with water proofing compound conforming to IS: 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. 0.00
66 c) After two days of proper curing applying a second coat of cement slurry using 2.75kg/ sqm of cement admixed with proprietary water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. 0.00
d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1cement : 4 coarse sand) admixed with proprietary water proofing compound conforming to IS:2645 and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300mm square 3mm deep. 0.00
e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge : 0.00
9.2.1/ 22.8.1 With average thickness of 120mm and minimum thickness at Khurra as 65 mm. Sqm 2,244.64 850.70 1909515.00
10.0 Miscellaneous works 0.00
67 10.1/ 4.17 Making plinth protection 50 mm thick of cement concrete 1:3:6 (1cement :3 coarse sand : 6 graded stone aggregate 20 mm nominalsize) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth. Sqm 673.80 436.60 294181.00
68 10.2/ 12.39 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement:2 coarse sand:4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 mx1 mx400 micron, finished 12 mm cement plaster 1:3 (1 cement:3 coarse sand) and a coat of neat cement rounding the edges and making and finishing the outlet complete Each 528.00 189.40 100003.00
10.3/ 2.35 Supplying chemical emulsion in sealed containers including delivery as specified. 0.00
69 10.3.1/ 2.35.1 Chlorpyriphos/Lindone emulsifiable concentrate of 20% Ltr 1,350.16 200.90 271247.00
70 10.4/ 2.37 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : 0.00
10.4.1/ 2.37.2 Along the external wall below concrete or masonary apron using chemical emulsion @ 2.55 litres per linear metre including drilling and plugging holes etc. 0.00
2.37.2.1 With Chlorpyriphos/ Lindane E.C. 20% with 1% Concentration. Metre 898.40 49.10 44111.00
71 10.4.2/ 2.37.3 Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1:2 (1 cement : 2 coarse sand) to match the existing floor. 0.00
10.4.3/ 2.37.3.1 With chlorpyriphos / Lindane E.C. 20% with 1% concentration. Sqm 2,244.64 241.20 541407.00
72 11.76/ Drive Providing well burnt brick bats & jhama do - do all complet job Cum 423.96 3,466.96 1469852.00
73 10.5/ 6.47A Providing 250mm wide brick drain in cement mortar (1:6) with av. 150mm. Clear depth and 250mm apron including cost of E/W. involved with 75mm cement concrete (1:4:8) over one brick designation 100-A flat soling in proper grade and slope at the base.the drain duly.plastered in CM. (1:3) with punning over exposed surface all complete as per building specification and direction of E/l, Mtr 898.40 1,087.90 977369.00
74 9/ 6.48A Providing 150mm wide brick drain in cement mortar (1:6) with av. 150mm clear depth and 125mm apron concrete (1: 4:8), over one brick designation 100-A flat soling in proper grade and slope at the base, the drain duly plastered in CM. (1:3) with punning over exposed surface all complete as per building specification and direction of E/l, Mtr 520.00 582.50 302900.00
75 10.6/ Derived Providing well burnt brick bats or Jhama bricks including ramming properly till compacted thickness is achieved, curing and carriage of water with all leads, making proper slope and blinding the top with cement mortar (1:10) all complete as per building specification and direction of E/I. cum 188.90 3,466.96 654909.00
76 5.1 Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring,shuttering,finishing and reinforcement-All work puto plinth level 0.00
5.1.2 1:1:5:3(1 cement: 1.5 coarse sand:3 graded stone aggregate 20 mm nominal size) cum 136.44 4688.3 639672.00
77 19.19 Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality 0.00
19.19.4.1 Circular shape 560 mm internal dia Each 48.00 1393.2 66874.00
78 1.0/ 3.18 16.1 Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres. cum 2,215.20 90.70 200919.00
79 1.3/ 23.4 Supplying and stacking a' site dump manure from approved source, excluding carriage (manure measured in stacks will be reduced by 8% for payment) cum 70.15 315.80 22153.00
23.4.3 Screened through sieve of l.S. designation 4.75 mm 0.00
80 1.4/ 23.5 Rough dressing the trenched ground including breaking clods. 100sqm 1,558.90 85.90 1339.00
81 1.5/ 23.6 Uprooting weeds form the trenched area after 10 to 15 days of its flooding with water including disposal of uprooted vegetation. 100sqm 1,558.90 283.20 4415.00
82 1.6/ 23.7 Fine dressing the ground 100sqm 1,558.90 208.80 3255.00
83 1.7/ 23.8 Spreading of sludge, dump manure or/and good earth in required thickness (Cost of sludge, dump manure or/and good earth to be paid separately). 0.00
84 1.8/ 23.9 Mixing earth and sjudge or manure in porportion specified or directed. Sqm 70.15 20.90 1466.00
85 1.9/ 23.10 Grassing with 'Doob' grass including watering and maintenance of the lawn for 30 days or more tili the grass forms a thick lawn free form weeds and fit for mowing including supplying good earth if needed. 0.00
23.10.3 In rows 5 cm apart in either direction. 100sqm 1,558.90 1,027.40 16016.00
86 1.0/ 23.2 Supplying and stacking of good earth at site including royalty but excluding carriage (earth measusred in stacks will be reduced by 20% for payment) Cum 11,522.43 143.50 1653469.00
87 8/ 16.69 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). Sqm 78.00 7,998.90 623914.00
88 11.0 Carriage of Materials 0.00
(i) Bricks (lead - 1 km kutcha + 7 km pucca) per 1000 nos 1,791,501.00 857.22 1535710.00
(ii) Coarse Sand cum 4,549.71 3,290.32 14970002.00
(iii) Stone Chips cum 4,871.94 3,262.29 15893681.00
(iv) Local sand (1 km kutcha + 2 km pucca) cum 3,781.78 285.67 1080341.00
Earth (Lead- 1 km kutcha + 2 km pucca) 11,522.43 285.67 3291613.00
89 12.0 Difference in cost of materials 0.00
90 24.1.1 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90 metre depth below ground level. 0.00
91 24.2.1 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I),including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools,plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level 0.00
92 24.3 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths,as per direction of Engineer -in-charge. 0.00
24.3.1 100 mm nominal size dia M 840.00 546.10 458724.00
24.3.2 150 mm nominal size dia M 276.00 660.10 182188.00
93 24.4 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge 0.00 0.00
24.4.1 100 mm nominal size dia M 240.00 573.10 137544.00
24.4.2 150 mm nominal size dia M 120.00 673.50 80820.00
94 24.5 Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-incharge Cum 2.40 1,188.90 2853.00
95 24.6 Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. Cum 2.40 1,195.60 2869.00
96 24.7 Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. Cum 4.80 1,195.60 5739.00
97 24.8 Gravel packing in tubewell construction in accordance with IS: 4097,including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. Cum 88.92 1,343.20 119437.00
98 24.9 Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer-in-charge. Each 36.00 1,213.20 43675.00
99 24.12 Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully develo ped, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting Hour 360.00 916.80 330048.00
100 24.13 Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 0.00
101 24.14 Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 0.00
102 Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 0.00
103 19.16 Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS : 1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be isible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design Each 96.00 310.90 29846.00
104 AR S.F.F Submerssible (2 H.P) Pumps with starter and cable etc. do - do all complet job Each 12.00 30,090.0 361080.00
AR Automatic Panel Board Each 12.00 5,600.0 67200.00
AR 40 mm Dia M.S. Clamps Each 12.00 665.00 7980.00
105 17.7 Providing and fixing water closet squatting pan (Indian type W.C.pan ) with 100 mm sand cast Iron P or S trap, 10 litre low fixtures complete, including cutting and making good the walls andlevel white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and floors wherever required 0.00
17.1.1 White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests each 104.00 4470.90 464974.00
106 17.3 Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I.brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : 0.00
17.3.1 W.C. pan with ISI marked white solid plastic seat and lid each 48.00 5504.30 264206.00
107 17.7 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require : 0.00
17.7.4 White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap Each 152.00 2135.80 324642.00
108 AR-SE Providing and Fixing Hand Fueset Each 48.00 1750.00 84000.00
109 17.8 Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings Each 152.00 1500.00 228000.00
110 17.10 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS : 13983 with C.I. brackets and stainless steel plug 40 mm,including painting of fittings and brackets, cutting and making good the walls wherever required 0.00
17.10.1 Kitchen sink with drain board 0.00
17.10.1.1 kitchen sink with drain board of size 510x1040mm bowl depth 250 mm. Each 104.00 5231.50 544076.00
111 17.28 Providing and fixing P.V.C waste pipe for sink or wash basin including P.V.C waste fittings complete. 0.00
Flexible pipe 0.00
112 17.31 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. Each 152.00 1068.50 162412.00
113 17.33 Providing and fixing 600x120x5 mm glass shelf with edges round off,supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete. Each 152.00 713.30 108422.00
114 17.71 Providing and fixing PTMT liquid soap container 109 mm wide,125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. Each 152.00 146.30 22238.00
115 17.73 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 0.00
116 17.73.2 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms Each 152.00 424.00 64448.00
117 17.72 Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour,weighing not less than 88 gms. Each 104.00 204.70 21289.00
18.49 Providing and fixing C.P. brass bib cock of approved quality conforming to IS :8931 each 352.00 434.20 152838.00
118 18.50 Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. 0.00
18.50.1 15 mm nominal bore each 248.00 715.10 177345.00
119 18.52 Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 0.00
18.52.1 15 mm nominal bore each 448.00 594.80 266470.00
120 18.53 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS :8931 0.00
18.53.1 15 mm nominal bore each 304.00 500.40 152122.00
121 18.22 Providing and fixing C.P. brass shower rose with 15 o r 20 m m in let : 0.00
122 18.58 Providing and fixing PTMT grating of approved quality and colour 0.00
18.58.1 Circular type 0.00
123 10.2/ 12.39 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement:2 coarse sand:4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 mx1 mx400 micron, finished 12 mm cement plaster 1:3 (1 cement:3 coarse sand) and a coat of neat cement rounding the edges and making and finishing the outlet complete Each 56.00 189.40 10606.00
124 12.78 Providing and fixing on wall face unplasticised PVC (working pressure 4 kg per sqcm) rain water pipes conforming to IS:4985 including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion. 0.00
125 12.79 Providing and fixing on wall face unplasticised PVC moulded fittings / accessories for unplasticised-PVC rain water pipes conforming to IS:4985 including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion. 0.00
12.79.1 Single pushfit Coupler: 0.00
12.79.4 Single tee without door 0.00
12.79.6 Shoe plain 0.00
126 12.80 Providing and fixing unplasticised-PVC pipe clip of approved design to unplasticised PVC rain water pipe by means of 50x50x50mm hard wood plugs, screwed with M.S screws or required length including cutting brick work and fixing on cement mortar (1:4) 1 cement:4 coarse sand and making good the wall etc. complete. 0.00
127 12.81 Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. Each 52.00 47.90 2491.00
Internal Water Supply 0.00
128 18.12 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. 0.00
External work 0.00
18.12.1 15 mm dia nominal bore Metre 276.00 197.60 54538.00
18.12.2 20mm dia nominal bore Metre 502.00 245.40 123191.00
18.12.3 25mm dia nominal bore Metre 710.00 342.00 242820.00
18.12.4 32mm dia nominal bore Metre 776.00 381.70 296199.00
18.12.5 40 mm dia nominal bore Metre 1,070.00 476.80 510176.00
129 18.11 Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall : 0.00
18.11.1 15 mm dia nominal bore metre 1,000.00 318.90 318900.00
18.11.2 20 mm dia nominal bore metre 480.00 374.00 179520.00
130 18.13 Making connection of G.I distribution branch with G.I main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete. 0.00
18.13.1 25 to 40mm nominal bore each 112.00 446.70 50030.00
131 18.8 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes having thermal stability for hot and cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in charge. 0.00
Concealed work including cutting chases and making good the walls etc. 0.00
18.8.1 15mm nominal outer dia pipes Metre 280.00 278.20 77896.00
18.8.2 20mm nominal outer dia pipes Metre 500.00 350.80 175400.00
18.8.3 25mm nominal outer dia pipes Metre 390.00 463.10 180609.00
18.8.4 32mm nominal outer dia pipes Metre 90.00 549.80 49482.00
18.16 Providing and fixing brass stop cock of approved quality : 0.00
18.16.1 15 mm nominal bore Each 146.00 303.80 44355.00
18.16.2 20 mm nominal bore Each 230.00 328.00 75440.00
132 18.17 Providing & fixing gun metal gate valve with C.I. wheel of approved quality, (screwed end) : 0.00
18.17.1 25 mm nominal bore Each 72.00 532.30 38326.00
18.17.2 32 mm nominal bore Each 52.00 589.90 30675.00
18.17.3 40 mm nominal bore Each 48.00 707.30 33950.00
133 18.19 Providing and fixing gun metal non-return valve of approved quality (screwed end). 0.00
18.19.2 32 mm nominal bore 0.00
134 18.38 Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work 0.00
18.38.1 15 mm dia nominal bore Metre 276.00 11.90 3284.00
18.38.2 20mm dia nominal bore Metre 502.00 13.90 6978.00
18.38.3 25mm dia nominal bore Metre 710.00 18.40 13064.00
18.38.4 32mm dia nominal bore Metre 776.00 21.60 16762.00
18.38.5 40 mm dia nominal bore Metre 1,070.00 25.70 27499.00
135 18.46 Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) 0.00
18.46.1 15 mm dia nominal bore Each 104.00 158.80 16515.00
18.46.2 20mm dia nominal bore Each 150.00 185.60 27840.00
18.46.3 25mm dia nominal bore Each 76.00 265.90 20208.00
18.46.4 32mm dia nominal bore Each 88.00 306.00 26928.00
18.46.5 40 mm dia nominal bore Each 144.00 419.70 60437.00
136 2.10 Excavating trenches of required width for pipes, cables etc including excavation for sockets and dressing of sides, ramming of bottoms depth upto 1.5m ,including getting out the excavated soil , and then returning the soil as required,in the layers not exceeding 20 cm in depth including consolidating each deposited layers by ramming watering and desposing of surplus excavated soil as dirceted within a lead of 50m 0.00
2.10.1.2 pipes cables etc exceeding 80mm dia but not exceeding 300 mm dia Mtr 1,200.00 391.70 470040.00
137 19.60 Providing and laying non -pressure NP2 class(light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 including testing of joints etc. complete 0.00
138 19.70 Constructing brick masonary manhole in cement mortar 1:4 (1 cement, 4 coarse sand.) R.C.C. top slab with1:2:4 mix(1 cement, 2 coars e sand, 4 graded stone aggregate 20 mm nominal size) foundation cocrete 1:4:8 mix (1cement, 4 coarse sand, 8 graded stone aggregate 40 mm nominal size.) inside plastering 12 mm thick with cement mortar 1:3 (1 cement, 3 coarse sand.) finished with floating coat of neat cement and making channels in cement concrete 1:2:4. finished with floating coat of neat cement complete as per standard design. 0.00
19.7.1 Inside size 90x80cm and 45 cm deep including C.I. cover with frame ( light duty) 455x610 mm internal diamension tatal weight of cover and fram to be not less than 38 kg (weight of cover23 kg and weight of frame 15 kg ) 0.00
19.7.1.1 With cmmon burnt clay F.P.S. (non modular)bricks with class designation 7.5 Each 140.00 7914.70 1108058.00
139 19.7.2 Inside size 120x90cm and 90 cm deep including C.I. cover with frame (medium duty) 500mm internal diameter total weight of cover and fram to be not less than 116 kg (weight of cover 58kg and weight of frame 58 kg ) 0.00
19.7.2.1 With cmmon burnt clay F.P.S. (non modular)bricks with class designation 7.5 Each 48.00 18015.20 864730.00
140 19.32 Making soak pit 2.5 m diameter 3.0 meter deep with 45x45 cm dry brick honey comb shaft with brick of class designation 75 and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. 0.00
19.32.1 With cmmon burnt clay F.P.S. (non modular)bricks with class designation 7.5 Each 12.00 33603.40 403241.00
FIRE FIGHTING WORK 0.00
FIRE HYDRANT SYSTEM 0.00
141 10 Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/ Stainless Steel cap and chain as required : 0.00
10.1 Single headed Gunmetal each 76.00 7245.00 550620.00
142 17 Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. "Connections from riser with 25 mm dia stop gun metalvalve & M.S. Pipe and socket." 0.00
143 16 Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : 0.00
16.1 Gunmetal each 152.00 5206 791312.00
144 18 Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : 0.00
18.1 Gunmetal each 76.00 2393 181868.00
145 NS MS hose cabinet with door fabricated from 16 G MS sheet with Full glasss door and locking arrangement suitable to accommodate 1 hydrant landing valve 1 fire hose reel, 2 15 m long 63 mm dia Hose, 1 branch pipe the door shal be painted one coat of primer and finished stove enamelled Fire Red fire hose written on front including suitably mounted on a raised masonry platform as required ( aprox size 1.20x2.10 m) for internal hydrant. each 76.00 38877.3 2954675.00
146 NS 100 mm dia Two way fire brigade inlet connection consisting of 63 mm dia size instantaneous make coupling and shall be protected by cap with chain glass bore etc. complete with one 100 mm dia sluice valve and 100 mm dia non-return valve ( to be connected to external ring main/wet riser/sprinkler riser). each 42.00 24715.1 1038034.00
147 MS cabinet with door fabricated from 16 G MS sheet with Full glasss door and locking arrangement painted one coat of primer and two or more coat of synthetic enamal paint of approved make and shade and suitably mounted on a raised masonry platform as required ( aprox size 0.60x0.60x0.450 m) Draw outlet/inlet connection. each 6.00 38877.3 233264.00
148 NS gun metal 4 way fire brigade inlet connection consisting 4 nos. of 63 mm dia size instantaneous male coupling with built in chek valves and 150 mm dia flanged outlet complete with bolts, nuts and rubber insertions as per IS:904 ( to be connected to static tank ) 2.00 44921.25 89843.00
149 NS MS cabinet with door fabricated from 16 G MS sheet with Full glasss door and locking arrangement painted one coat of primer and two or more coat of synthetic enamal paint of approved make and shade and suitably mounted on a raised masonry platform as required ( aprox size 0.60x0.60x0.450 m) Draw outlet/inlet connection. each 42.00 4832.1 202948.00
PIPES & ACCESSORIES 0.00
150 7 Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS:1239 including Welding, fittings like elbows, tees, flanges,tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required 0.00
151 11 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 0.00
152 14 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required 0.00
153 NS Providing and fixing ball valve with hard chrome palted ball inside PTFE(Teflon)seat 7 ring with chrome plated center handle frame BSP threads complete. 0.00
154 2.10 Excavating trenches of required width for pipes cables, etc, including\ excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m including getting out the excavated soil , and then returning the soil as required , in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed , within a lead of 50 0.00
2.10.1 All kinds of soil. 0.00
2.10.1.2 Pipes, cables etc. exceeding 80 mm dia . But not exceeding 300mm dia. M 172.00 391.70 67372.00
155 4.1 Providing and laying in position cement concrete of specified grade exluding the cost of centring and shuttering-all work upto plinth level. 0.00
4.1.5 1:3:6 (1 Cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) CUM 58.00 3434.00 199172.00
156 18.35.1 Constructing masonry Chamber 120x120x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : CUM 12.00 18802.60 225631.00
157 18.59 Providing and fixing C.I. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete (The tail pieces,tapers etc if required will be paid separately) : 0.00
158 18.31 Providing and fixing C.I. sluice valves (with cap) complete with bolts,nuts, rubber insertions etc. (the tail pieces if required will be paid separately) : 0.00
18.31.3 150 mm diameter 0.00
18.31.1.2 100 mm diameter
159 NS Providing, installation, testing & commissioning of resilient rubber lined single arch vibration eliminator suitable for raw water up to 45deg. C temprature working pressure 8.8kg/cm2 and test presssure 14kg/cm2 0.00
150 mm diameter Each 20.00 11058.96 221179.00
PORTABLE FIRE EXTINGUISHER 0.00
SUPPLY,INSTALLATION,TESTING&COMMISSIONING OF: 0.00
PORTABLE FIRE EXTINGUISHER 0.00
160 NS ISI marked (IS:940) poratble chemical fire extinguisher water (gas pressure) type capacity 9 ltrs. With gun metal cap and nozzle and complete in all respects including initial fill and wall suspension bracket. 0.00
161 NS ISI marked (IS:2878) poratble fire extinguisher CARBON-DIOXIDE type FLAT BASE INCLUDING VALVE DISCHARGE HOSE OF NOT LESS THAN 10 MM DIA 1 M LONG & COMPLETE IN ALL RESPCT INCLUDING INITIAL FILL WITH co and wall suspension bracket. GAS CONFIRMING TO isd:307-01966 FILLED TO FILLING RATIO OF NOT MORE THAN 0.667 OF NOT MORE THAN 0.667 AND WALL SUSPANSION BRACKET. 0.00
162 NS ABC stored pressure type dry chemical powder (mono ammonium phgosphate) 6 kg fire extinguisher with fixing hangers, hose brackets, screws to required size etc. completet as per iS 14609. 0.00
6.00 KG CAPACITY Each 82.00 5308.88 435328.00
FIRE PUMPS,VALVES & ACCESSORIES 0.00
163 4 Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump) 0.00
(a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520 0.00
(b) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-325. 0.00
(c) M.S.fabricated common base plate, coupling, coupling guard,foundation bolts etc.as required. 0.00
(d) Suitable cement concrete foundation duly plastered and with anti vibration pads. 0.00
Total=Rs 273,137,957.00
Add 5.36% GST(Excepted NS Rs 1832825.00)=(+)Rs 14,541,955.00
Gross Total=Rs 287,679,912.00
1 1.3 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit with modular switch , modular plate, suitable size G.I. box etc as required.
Batten Holder Point 104
Surface/Downlighter/Panel Light Point=10-5 5
Tube light point 72
Ceiling Fan point 40
Wall/Exhaust Fan Point 24
2 1.4 Wiring for twin control light point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box etc as reqd.
Downlighter Light Point-5 (STAIR) 5 Point 1248.00 6,240.00
3 1.31 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as reqd. 56 Each 414.00 23,184.00
4 1.32 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. 64 Each 531.00 33,984.00
5 1.5 Wiring for light/ power plug with 2 X 4 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit along with 1 Nos 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. 640 Metre 309.00 197,760.00
6 1.7 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
1.7.1 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire 572 Metre 201.00 114,972.00
1.7.2 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire for 90W street light 150 Metre 246.00 36,900.00
1.7.2 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire for CT 240 Metre 246.00 59,040.00
1.7.3 2 x 4 sq. mm + 1 x 4 sq. mm earth wire for AC point 192 Metre 309.00 59,328.00
1.7.4 2 x 6 sq. mm + 1 x 6 sq. mm earth wire 48 Metre 422.00 20,256.00
1.7.5 2 X 10 sq. mm + 1 X 6 sq. mm earth wire 48 Metre 557.00 26,736.00
1.7.6 2 X 16 sq. mm + 1 X 6 sq. mm earth wire 110 Metre 775.00 85,250.00
7 1.53 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 amps modular socket outlet and 25 amp modular SP MCB 'C' curve, including connections, painting etc. as required. 16 Each 683.00 10,928.00
8 1.57 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 4 nos. 5 pin 5/6 amps modular socket outlet and 4 nos. 5/6 amps modular switch, connection etc. as required. 24 Each 1,064.00 25,536.00
9 1.33 Supplying and fixing 2 pin, 5/6 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 96 Each 64.00 6,144.00
10 1.34 Supplying and fixing batten/ angle holder including connection etc. as reqd. 104 Each 80.00 8,320.00
11 1.25 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate/ switch box including connections but excluding modular plate etc. as required. 40 Each 358.00 14,320.00
12 1.38 Supplying and fixing electronic musical call suitable for single phase, 230 volts complete bell as required. 8 Each 351.00 2,808.00
13 2.8 Supplying and fixing following way single pole & neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus-bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
2.8.6 8 way, Double door (for Street Light) 1 Each 2591.00 2,591.00
2.8.7 12 way, Double door 16 Each 2314.00 37,024.00
14 2.12 Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as reqd.
2.12.1 6 A to 32 A, Single pole 166 Each 237.00 39,342.00
15 2.13 Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as reqd.
2.13.1 6 A to 32 A, double pole 1 Each 667.00 667.00
2.13.3 40 A to 63 A, double pole 16 Each 1198.00 19,168.00
16 2.1 Providing and fixing following capacity double pole/ TP&N sheet metal switch disconnector fuse unit in the existing metal panel board with rewireable type fuses including drilling holes in metal panel, making connections etc. as required.
2.1.3 63 Amp, double pole 0 Each 4463.00 0.00
17 5.1 Supplying and fixing 4'X18 watt LED batten with minimum efficacy 100 lm/w in polycarbonate housing and complete with integrated electronic driver etc directly on wall/ ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor etc. as required. 72 Each 521.00 37,512.00
18 6.1 Supplying and fixing of following types lamp in the existing electrical fitting/ fixtures etc. as required.
6.1.4 9/10 watt LED lamp 104 Each 161.00 16,744.00
19 5.14 Supplying and fixing following types LED street light with minimum efficacy 100 lm/w in die cast aluminium housing, toughened glass, IP 66 protection and complete with electronic driver etc on pole/building including connection earthing the body etc as required.
20 8.5 Supplying and fixing of 32 mm dia X 1.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV/ HPSV/ LED street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required. 6 Each 1038.00 6,228.00
21 5.7 Supplying and fixing recess mounted following types LED downlighter with minimum efficacy 100 lm/w in pressure die-cast aluminium housing and integrated electronic driver etc directly on ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor cable etc as required.
22 8.15 Supply and installation of regular/standard model A.C. ceiling fan of 1200 mm sweep with service value (CM/MM) minimum 4.00, Air delivery minimum 210 cum/min including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated copper conductor etc as required. 40 Each 2,482.00 99,280.00
23 8.17 Supply and installation of following sweep/ sizes metallic blade, heavy duty, single phase, 230 V A.C. Exhaust Fan in existing opening including making good the damage, connection, testing and commissioning etc as required.
24 2.4 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections etc. as required.
25 2.7 Providing and fixing following capacity four pole ON-load/ panel mounted changeover switches inside the existing cubical panel board including drilling holes in cubicle panel, making connections etc. as required.
26 8.11 Supply and fixing of fabricated Electrical control panel of cubical construction, floor/wall mounted type, fabricated out of 16 SWG CRCA sheet, compartmentalised with hinged doors, dust and vermin proof, powder coated painting of approved shade after 7 tank treatment process, cable alley, internal wiring, earth terminals, Bus bar Chamber, insulator and complete in all respect etc and panel manufactures must be approved by CPRI. (But without RYB indicator, ammeter, voltmeter, inter-connection copper conductor cable/solid copper strip, switchgears etc.) 20 sq.ft. 1809.00 36,180.00
27 A/R Supplying of copper strip of all sizes for bus bar strip/interconnection including drilling holes etc as reqd. 12 Kg 871.00 10,452.00
28 8.13 Supply and fixing panel mounted digital multimeter (Voltmeter & ammeter) including CT coil and RYB pilot indictor in the existing cubical panel board including drilling holes in the panel board making connections etc as required. 1 Each 6536.00 6,536.00
29 2.12 Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
30 2.20 Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel at least 2 mm thick, vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 1 Each 214.00 214.00
31 1.15 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed PVC conduit as required.
1.15.1 1 x 1.5 sq.mm for inverter wiring 390 Metre 38.00 14,820.00
32 7.9 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed PVC conduit as required.
33 7.7 Supply of following sizes and core PVC/XLPE insulated, PVC sheathed (heavy duty) armoured electrical power cable with aluminium conductor for working voltage upto 1.1 KV as required.
34 7.1 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.
7.1.2 Above 35 sq. mm and upto 95 sq. mm 90 Metre 326.00 29,340.00
35 DSR-2022/9.1 Supplying and making end termination with brass compression gland and aluminium lugs for follwing size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1KV grade as reqd.
36 3.2 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc with charcoal/coke and salt as required. 2 Set 6,323.00 12,646.00
37 3.7 Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble as required. 30 Metre 37.00 1,110.00
FOR LIGHTNING ARRESTER
38 4.2 Providing and fixing lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. 4 Metre 416.00 1,664.00
39 4.4 Jointing copper/ G.I. tape ( with another copper/ G I tape, base of the finial or any other metallic object ) by riverting/ nut bolting sweating and soldering etc. as required. 8 Each 81.00 648.00
40 4.7 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. ( For horizontal run) 160 Metre 102.00 16,320.00
41 4.8 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. ( For vertical run) 60 Metre 145.00 8,700.00
42 4.12 Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of tinned G.I. bolts, nuts, chuk nuts and spring washers etc. complete as required. 4 Each 102.00 408.00
43 3.2 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc with charcoal/coke and salt as required. 8 Set 6,323.00 50,584.00
44 3.9 Supplying and laying 25 mm X 6 mm G.I. strip at 0.50 metre below ground as strip earth electrode, including connection/ termination with GI nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping with 2 sets of G.I. nut bolt & spring washer spaced at 50 mm) 80 Metre 133.00 10,640.00
Total Rs. 1,636,560.00
Such type of 4 Blocks Total Rs. 6,546,240.00
Part 'B' Supporting Staff -IV Building (G+3) (2 Blocks)
45 1.3 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit with modular switch , modular plate, suitable size G.I. box etc as required.
Batten Holder Point 128
Surface/Downlighter/Panel Light Point=13-5 8
Tube light point 80
Ceiling Fan point 48
Wall/Exhaust Fan Point 32
46 1.4 Wiring for twin control light point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box etc as required.
Downlighter Light Point-5 (STAIR) 5 Point 1248.00 6,240.00
47 1.31 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. 80 Each 414.00 33,120.00
48 1.32 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. 80 Each 531.00 42,480.00
49 1.5 Wiring for light/ power plug with 2 X 4 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit along with 1 Nos 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. 720 Metre 309.00 222,480.00
50 1.7 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
1.7.1 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire 638 Metre 201.00 128,238.00
1.7.2 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire for 90W street light 150 Metre 246.00 36,900.00
1.7.2 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire for CT 144 Metre 246.00 35,424.00
1.7.4 2 x 6 sq. mm + 1 x 6 sq. mm earth wire for DB 198 Metre 422.00 83,556.00
51 1.57 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 4 nos. 5 pin 5/6 amps modular socket outlet and 4 nos. 5/6 amps modular switch, connection etc. as required. 16 Each 1,064.00 17,024.00
52 1.33 Supplying and fixing 2 pin, 5/6 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 112 Each 64.00 7,168.00
53 1.34 Supplying and fixing batten/ angle holder including connection etc. as reqd. 128 Each 80.00 10,240.00
54 1.25 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate/ switch box including connections but excluding modular plate etc. as required. 48 Each 358.00 17,184.00
55 1.38 Supplying and fixing electronic musical call suitable for single phase, 230 volts complete bell as required. 16 Each 351.00 5,616.00
56 2.8 Supplying and fixing following way single pole & neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus-bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
2.8.6 8 way, Double door (1 for Street Light) 1 Each 2591.00 2,591.00
2.8.7 12 way, Double door 16 Each 2314.00 37,024.00
57 2.12 Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
2.12.1 6 A to 32 A, Single pole 166 Each 237.00 39,342.00
58 2.13 Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
2.13.1 6 A to 32 A, double pole 1 Each 667.00 667.00
2.13.3 40 A to 63 A, double pole 16 Each 1198.00 19,168.00
59 5.1 Supplying and fixing 4'X18 watt LED batten with minimum efficacy 100 lm/w in polycarbonate housing and complete with integrated electronic driver etc directly on wall/ ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor etc. as required. 80 Each 521.00 41,680.00
60 6.1 Supplying and fixing of following types lamp in the existing electrical fitting/ fixtures etc. as required.
6.1.4 9/10 watt LED lamp 128 Each 161.00 20,608.00
61 5.14 Supplying and fixing following types LED street light with minimum efficacy 100 lm/w in die cast aluminium housing, toughened glass, IP 66 protection and complete with electronic driver etc on pole/building including connection earthing the body etc as required.
62 8.5 Supplying and fixing of 32 mm dia X 1.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV/ HPSV/ LED street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required. 6 Each 1038.00 6,228.00
63 5.7 Supplying and fixing recess mounted following types LED downlighter with minimum efficacy 100 lm/w in pressure die-cast aluminium housing and integrated electronic driver etc directly on ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor cable etc as required.
64 8.15 Supply and installation of regular/standard model A.C. ceiling fan of 1200 mm sweep with service value (CM/MM) minimum 4.00, Air delivery minimum 210 cum/min including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated copper conductor etc as required. 48 Each 2,482.00 119,136.00
65 8.17 Supply and installation of following sweep/ sizes metallic blade, heavy duty, single phase, 230 V A.C. Exhaust Fan in existing opening including making good the damage, connection, testing and commissioning etc as required.
66 2.4 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections etc. as required.
67 2.7 Providing and fixing following capacity four pole ON-load/ panel mounted changeover switches inside the existing cubical panel board including drilling holes in cubicle panel, making connections etc. as required.
68 8.11 Supply and fixing of fabricated Electrical control panel of cubical construction, floor/wall mounted type, fabricated out of 16 SWG CRCA sheet, compartmentalised with hinged doors, dust and vermin proof, powder coated painting of approved shade after 7 tank treatment process, cable alley, internal wiring, earth terminals, Bus bar Chamber, insulator and complete in all respect etc and panel manufactures must be approved by CPRI. (But without RYB indicator, ammeter, voltmeter, inter-connection copper conductor cable/solid copper strip, switchgears etc.) 15 sq.ft. 1809.00 27,135.00
69 A/R Supplying of copper strip of all sizes for bus bar strip/interconnection including drilling holes etc as reqd. 9 Kg 871.00 7,839.00
70 8.13 Supply and fixing panel mounted digital multimeter (Voltmeter & ammeter) including CT coil and RYB pilot indictor in the existing cubical panel board including drilling holes in the panel board making connections etc as required. 1 Each 6536.00 6,536.00
71 2.12 Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
72 2.20 Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel at least 2 mm thick, vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 1 Each 214.00 214.00
73 1.15 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed PVC conduit as required.
1.15.1 1 x 1.5 sq.mm for inverter wiring 319 Metre 38.00 12,122.00
74 7.9 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed PVC conduit as required.
75 7.7 Supply of following sizes and core PVC/XLPE insulated, PVC sheathed (heavy duty) armoured electrical power cable with aluminium conductor for working voltage upto 1.1 KV as reqd.
76 7.1 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.
7.1.2 Above 35 sq. mm and upto 95 sq. mm 90 Metre 326.00 29,340.00
77 DSR-2022/9.1 Supplying and making end termination with brass compression gland and aluminium lugs for follwing size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1KV grade as required.
78 3.2 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc with charcoal/coke and salt as required. 2 Set 6,323.00 12,646.00
79 3.7 Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble as required. 30 Metre 37.00 1,110.00
FOR LIGHTNING ARRESTER
80 4.2 Providing and fixing lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. 4 Metre 416.00 1,664.00
81 4.4 Jointing copper/ G.I. tape ( with another copper/ G I tape, base of the finial or any other metallic object ) by riverting/ nut bolting sweating and soldering etc. as required. 8 Each 81.00 648.00
82 4.7 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. ( For horizontal run) 170 Metre 102.00 17,340.00
83 4.8 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. ( For vertical run) 60 Metre 145.00 8,700.00
84 4.12 Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of tinned G.I. bolts, nuts, chuk nuts and spring washers etc. complete as required. 4 Each 102.00 408.00
85 3.2 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc with charcoal/coke and salt as required. 8 Set 6,323.00 50,584.00
86 3.9 Supplying and laying 25 mm X 6 mm G.I. strip at 0.50 metre below ground as strip earth electrode, including connection/ termination with GI nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping with 2 sets of G.I. nut bolt & spring washer spaced at 50 mm) 80 Metre 133.00 10,640.00
Total Rs. 1,646,943.00
Such type of 2 Blocks Total Rs. 3,293,886.00
Part 'C' Lecturer's Quarter Building (G+3) (6 Blocks)
87 1.3 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit with modular switch , modular plate, suitable size G.I. box etc as required.
Batten Holder Point 104
Surface/Downlighter/Panel Light Point=10-5 5
Tube light point 72
Ceiling Fan point 40
Wall/Exhaust Fan Point 24
88 1.4 Wiring for twin control light point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box etc as required.
Downlighter Light Point-5 (STAIR) 5 Point 1248.00 6,240.00
89 1.31 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. 64 Each 414.00 26,496.00
90 1.32 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. 64 Each 531.00 33,984.00
91 1.5 Wiring for light/ power plug with 2 X 4 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit along with 1 Nos 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. 640 Metre 309.00 197,760.00
92 1.7 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
1.7.1 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire 572 Metre 201.00 114,972.00
1.7.2 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire for 90W street light 150 Metre 246.00 36,900.00
1.7.2 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire for CT 240 Metre 246.00 59,040.00
1.7.3 2 x 4 sq. mm + 1 x 4 sq. mm earth wire for AC point 192 Metre 309.00 59,328.00
1.7.4 2 x 6 sq. mm + 1 x 6 sq. mm earth wire for street light DB 8 Metre 422.00 3,376.00
1.7.5 2 X 10 sq. mm + 1 X 6 sq. mm earth wire 48 Metre 557.00 26,736.00
1.7.6 2 X 16 sq. mm + 1 X 6 sq. mm earth wire 110 Metre 775.00 85,250.00
93 1.53 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 amps modular socket outlet and 25 amp modular SP MCB 'C' curve, including connections, painting etc. as required. 16 Each 683.00 10,928.00
94 1.57 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 4 nos. 5 pin 5/6 amps modular socket outlet and 4 nos. 5/6 amps modular switch, connection etc. as required. 24 Each 1,064.00 25,536.00
95 1.33 Supplying and fixing 2 pin, 5/6 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 96 Each 64.00 6,144.00
96 1.34 Supplying and fixing batten/ angle holder including connection etc. as reqd. 104 Each 80.00 8,320.00
97 1.25 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate/ switch box including connections but excluding modular plate etc. as required. 40 Each 358.00 14,320.00
98 1.38 Supplying and fixing electronic musical call suitable for single phase, 230 volts complete bell as required. 8 Each 351.00 2,808.00
99 2.8 Supplying and fixing following way single pole & neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus-bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
2.8.6 8 way, Double door (For Street Light) 1 Each 2591.00 2,591.00
2.8.7 12 way, Double door 16 Each 2314.00 37,024.00
100 2.12 Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
2.12.1 6 A to 32 A, Single pole 166 Each 237.00 39,342.00
101 2.13 Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
2.13.1 6 A to 32 A, double pole 1 Each 667.00 667.00
2.13.3 40 A to 63 A, double pole 16 Each 1198.00 19,168.00
102 2.1 Providing and fixing following capacity double pole/ TP&N sheet metal switch disconnector fuse unit in the existing metal panel board with rewireable type fuses including drilling holes in metal panel, making connections etc. as required.
2.1.3 63 Amp, double pole 0 Each 4463.00 0.00
103 5.1 Supplying and fixing 4'X18 watt LED batten with minimum efficacy 100 lm/w in polycarbonate housing and complete with integrated electronic driver etc directly on wall/ ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor etc. as required. 72 Each 521.00 37,512.00
104 6.1 Supplying and fixing of following types lamp in the existing electrical fitting/ fixtures etc. as required.
6.1.4 9/10 watt LED lamp 104 Each 161.00 16,744.00
105 5.14 Supplying and fixing following types LED street light with minimum efficacy 100 lm/w in die cast aluminium housing, toughened glass, IP 66 protection and complete with electronic driver etc on pole/building including connection earthing the body etc as required.
106 8.5 Supplying and fixing of 32 mm dia X 1.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV/ HPSV/ LED street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required. 6 Each 1038.00 6,228.00
107 5.7 Supplying and fixing recess mounted following types LED downlighter with minimum efficacy 100 lm/w in pressure die-cast aluminium housing and integrated electronic driver etc directly on ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor cable etc as required.
108 8.15 Supply and installation of regular/standard model A.C. ceiling fan of 1200 mm sweep with service value (CM/MM) minimum 4.00, Air delivery minimum 210 cum/min including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated copper conductor etc as required. 40 Each 2,482.00 99,280.00
109 8.17 Supply and installation of following sweep/ sizes metallic blade, heavy duty, single phase, 230 V A.C. Exhaust Fan in existing opening including making good the damage, connection, testing and commissioning etc as required.
110 2.4 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections etc. as required.
111 2.7 Providing and fixing following capacity four pole ON-load/ panel mounted changeover switches inside the existing cubical panel board including drilling holes in cubicle panel, making connections etc. as required.
112 8.11 Supply and fixing of fabricated Electrical control panel of cubical construction, floor/wall mounted type, fabricated out of 16 SWG CRCA sheet, compartmentalised with hinged doors, dust and vermin proof, powder coated painting of approved shade after 7 tank treatment process, cable alley, internal wiring, earth terminals, Bus bar Chamber, insulator and complete in all respect etc and panel manufactures must be approved by CPRI. (But without RYB indicator, ammeter, voltmeter, inter-connection copper conductor cable/solid copper strip, switchgears etc.) 20 sq.ft. 1809.00 36,180.00
113 A/R Supplying of copper strip of all sizes for bus bar strip/interconnection including drilling holes etc as reqd. 12 Kg 871.00 10,452.00
114 8.13 Supply and fixing panel mounted digital multimeter (Voltmeter & ammeter) including CT coil and RYB pilot indictor in the existing cubical panel board including drilling holes in the panel board making connections etc as required. 1 Each 6536.00 6,536.00
115 2.12 Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
116 2.20 Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel at least 2 mm thick, vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 1 Each 214.00 214.00
117 1.15 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed PVC conduit as required.
1.15.1 1 x 1.5 sq.mm for inverter wiring 390 Metre 38.00 14,820.00
118 7.9 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed PVC conduit as required.
119 7.7 Supply of following sizes and core PVC/XLPE insulated, PVC sheathed (heavy duty) armoured electrical power cable with aluminium conductor for working voltage upto 1.1 KV as required.
120 7.1 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.
7.1.2 Above 35 sq. mm and upto 95 sq. mm 90 Metre 326.00 29,340.00
121 DSR-2022/9.1 Supplying and making end termination with brass compression gland and aluminium lugs for follwing size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1KV grade as required.
122 3.2 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc with charcoal/coke and salt as required. 2 Set 6,323.00 12,646.00
123 3.7 Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble as required. 30 Metre 37.00 1,110.00
FOR LIGHTNING ARRESTER
124 4.2 Providing and fixing lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. 4 Metre 416.00 1,664.00
125 4.4 Jointing copper/ G.I. tape ( with another copper/ G I tape, base of the finial or any other metallic object ) by riverting/ nut bolting sweating and soldering etc. as required. 8 Each 81.00 648.00
126 4.7 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. ( For horizontal run) 160 Metre 102.00 16,320.00
127 4.8 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. ( For vertical run) 60 Metre 145.00 8,700.00
128 4.12 Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of tinned G.I. bolts, nuts, chuk nuts and spring washers etc. complete as required. 4 Each 102.00 408.00
129 3.2 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc with charcoal/coke and salt as required. 8 Set 6,323.00 50,584.00
130 3.9 Supplying and laying 25 mm X 6 mm G.I. strip at 0.50 metre below ground as strip earth electrode, including connection/ termination with GI nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping with 2 sets of G.I. nut bolt & spring washer spaced at 50 mm) 80 Metre 133.00 10,640.00
Total Rs. 1,622,992.00
Such type of 6 Blocks Total Rs. 9,737,952.00
Part 'D' Campus Light in proposed Area
131 5.14 Supplying and fixing following types LED street light with minimum efficacy 100 lm/w in die cast aluminium housing, toughened glass, IP 66 protection and complete with electronic driver etc on pole/building including connection earthing the body etc as required.
132 8.22 Supply and erection of 6 metre height Hot-dip galvanized octagonal street light pole with following arm with top dia 70 mm and bottom dia A/F 130 mm, made of 3 mm thick sheet along with base plate of size 220 X 220 X 12 mm , small door opening for junction box mounting including 6A 'C' series SP MCB, connector, and suitable size foundation bolts with template as required.(but without pole foundation)
133 3.18 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. 420 Metre 31.00 13,020.00
134 1.15 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed PVC conduit as required.
135 7.7 Supply of following sizes and core PVC/XLPE insulated, PVC sheathed (heavy duty) armoured electrical power cable with aluminium conductor for working voltage upto 1.1 KV as required.
7.7.3 10 sq.mm, 2 core (for Campus Light) 420 Metre 201.00 84,420.00
136 7.3 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required but excluding sand cushioning and protective covering.
137 3.2 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc with charcoal/coke and salt as required. 4 Set 6,323.00 25,292.00
138 3.7 Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble as required. 20 Metre 37.00 740.00
Total Rs. 798,112.00
Part 'E' FEEDER PANEL
139 2.4 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections etc. as required.
140 8.12 Supply and fixing fabricated Feeder pillar of cubical construction, floor mounted type, fabricated out of 14 SWG CRCA sheet, compartmentalised with hinged doors, dust and vermin proof, powder coated painting of approved shade after 7 tank treatment process, cable alley, internal wiring, earth terminals, Bus bar Chamber, insulator, with 40mm X 40mm X 5mm angle iron stand and complete in all respect etc and must be CPRI approved panel manufactures. (But without RYB LED lamp, ammeter, voltmeter, inter-connection copper conductor cable/solid copper strip, switchgears, PCC work etc.) 30 sq.ft. 2261.00 67,830.00
141 A/R Supplying of copper strip of all sizes for bus bar strip/interconnection including drilling holes etc as reqd. 18 Kg 871.00 15,678.00
142 8.13 Supply and fixing panel mounted digital multimeter (Voltmeter & ammeter) including CT coil and RYB pilot indictor in the existing cubical panel board including drilling holes in the panel board making connections etc as required. 1 Each 6536.00 6,536.00
143 2.12 Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
144 2.20 Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel at least 2 mm thick, vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 1 Each 214.00 214.00
145 1.15 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed PVC conduit as required.
146 7.9 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed PVC conduit as required.
147 7.7 Supply of following sizes and core PVC/XLPE insulated, PVC sheathed (heavy duty) armoured electrical power cable with aluminium conductor for working voltage upto 1.1 KV as required.
148 7.1 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.
7.1.4 Above 185 sq. mm and upto 400 sq. mm 140 Metre 368.00 51,520.00
149 DSR 9.1 Supplying and making end termination with brass compression gland and aluminium lugs for follwing size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1KV grade as required.
150 3.5 Earthing with copper earth plate 600mmX600mmX3mm thick including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe 2.7 metre long etc. ( but without charcoal/ coke and salt ) as required. 2 Set 12415.00 24,830.00
151 3.17 Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing etc. as required. 30 Metre 144.00 4,320.00
Total Rs. 783,890.00
Such type of 2 Feeder Total Rs. 1,567,780.00
152 Part 'F' Sub-Station
AR-3 Supply, Installation, Testing and Commisioning ( SITC) of 11KV/433V, 500KVA Outdoor type Compact Sub-Station with Oil type Transformer. 1 Each 3975284.00 3,975,284.00
HT - 11KV ,630A, 21KA/3sec Ring Main Units (CV)-One no. Manual operated Load Break Switch + 1 no. Manual operated VCB.
Transformer - ONAN Type- Losses As per latest amendment 2021 of IS 1180
LT - 800Amps, 50KA fixed Manual ACB incomer with Microprocessor release + 400Amps-2/3/4 nos. OG fixed Manual 36KA MCCB Microprocessor release.
(Make- ABB/Schneider/Siemens)
153 7.8 Supply of following sizes and core PVC/XLPE insulated, PVC sheathed (heavy duty) armoured electrical power H.T. cable with aluminium conductor for working voltage upto 11 KV as required.
154 7.5 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.
7.5.2 Above 120 sq. mm and upto 400 sq. mm 75 Metre 431.00 32,325.00
155 3.21 Providing chemical/mineral maintenance free earthing system comprising of copper coated earth electrode 3 metre length and 17.2 mm outer dia along with 25 kg earth conductivity enhancing back fill mineral compound for earth electrode to fill up the excavated earth and earth inspection pit etc. as required. 6 Set 16675.00 100,050.00
156 3.17 Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing etc. as required. 60 Metre 144.00 8,640.00
Total Rs. 4,323,579.00
Part 'A' Technical support Staff Building (G+3) (4 Blocks) 6,546,240.00
Part 'B' Supporting Staff -IV Building (G+3) (2 Blocks) 3,293,886.00
Part 'C' Lecturer's Quarter Building (G+3) (6 Blocks) 9,737,952.00
Part 'D' Campus Light in proposed Area 798,112.00
Part 'E' FEEDER PANEL (2 Nos.) 1,567,780.00
Part 'F' Sub-Station 4,323,579.00
Total Rs. 26,267,549.00
Electrical 26,267,549.00
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
NIT-10 Re Tender Faculty Staff Quarter.pdf
NIT • 1.13 MB
Paper Cutting NIT-10 Re Tender Faculty Staff Quarter.pdf
NIT • 0.10 MB
Check list farwarding.pdf
NIT • 1.76 MB
JointVentureGuidelines.pdf
NIT • 2.48 MB
Letter No 3183 Dated 3-6-2020.pdf
NIT • 1.08 MB
Letter no 7291 E-in-C bcd.pdf
NIT • 0.55 MB
Letter no 7292 E-in- C bcd.pdf
NIT • 0.64 MB
Letter No 5468 dt 15-09-2020.pdf
NIT • 0.46 MB
7974 UDIN.pdf
NIT • 2.18 MB
9417 10 Below.pdf
NIT • 3.35 MB
Evaluation Faculty Staff Quarter.xls
NIT • 0.04 MB
SBD Document NIT-10 Faculty Staff Quarter.doc
NIT • 0.82 MB
NIT-10 Re Tender Faculty Staff Quarter.pdf
NIT • 1.13 MB
BOQ Civil + Electrical.xlsx
NIT • 0.09 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].