Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.8 LAdmitted-Finance | ₹18.8 L | L1 | Admitted-Finance |
| 2 | L2₹22.2 LAdmitted-Finance | ₹22.2 L | L2 | Admitted-Finance |
| 3 | Rejected-Technical | - | - | Rejected-Technical PQC NOT QUALIFIED |
| Sl No | Description | Qty | Unit | GENERAL ELECTRICAL WORKS L1 | JAMSHEDPUR RFRIGERATION AND ELECTRICAL L2 |
|---|---|---|---|---|---|
| 1.00 | Annual maintenance of window type air conditioner including checking, servicing, repairing, complete overhauling and painting as and when required (but complete overhauling at least twice in a year and painting once in a year) and attending breakdown calls within 24 hours including replacement of all spare parts as per scope of work & special conditions per machine per year. Note: i) Cleaning and general maintenenece of ACs shall have to be carried out as and when required .The frequency of this cleaning and Gen. maintenece shall be high in some places(dusty area) and may be low in some other places. This shall be carried out as per instruction of engineer incharge. ii) Supply of spares which are included in this schedule shall be used for maintenance of ACs as and when required. | 26 | per machine per year | 1,43,000 ₹1.7 L | 2,21,000 ₹2.6 L |
| 2.00 | Annual maintenance of split type air conditioner including checking, servicing, repairing overhauling and painting as and when required ( but complete overhauling at least twice in a year and painting once in a year) and attending breakdown calls within 24 hours including replacement of all spare parts as per scope of work and special conditions per machine per year. Note: i) Cleaning and general maintenenece of ACs shall have to be carried out as and when required .The frequency of this cleaning and Gen. maintenece shall be high in some places(dusty area) and may be low in some other places. This shall be carried out as per instruction of engineer incharge. ii) Suupply of spares which are included in this schedule shall be used for maintenance of ACs as and when required. | 81 | per machine per year | 4,53,600 ₹5.3 L | 6,88,500 ₹8.1 L |
| 3.00 | Annual maintenance of water coolers upto 300 litres including checking, servicing, repairing overhauling and painting as and when required (but at least twice in a year) and attending breakdown calls within 24 hours including replacement of all spare parts as per scope of work & special conditions per machine per year. Note: Supply of spares which are included in this schedule shall be used for maintenance of coolers as and when required. | 5 | per machine per year | 24,000 ₹28,320 | 42,500 ₹50,150 |
| 4.00 | Annual maintenance of water cooler cum purifiers of Make Eureka Forbes/equivalent, Aquaguard Model: PSS120 UV / equivalent model of upto 120 litres / equivalent including checking, servicing, repairing, overhauling as and when required (but at least three times in a year) and attending breakdown calls within 24 hours including replacement of all spare parts as per scope of work & special conditions per machine per year. Note: i) Painting (if required) once per year shall also be carried out by bidder as per direction of Engineer-In-Charge. ii) Supply of spares which are included in this schedule shall be used for maintenance of water coolers cum purifiers as and when required. | 3 | per machine per year | 16,500 ₹19,470 | 25,500 ₹30,090 |
| 5.00 | Annual Maintenance of Dryer of Air Compressor including checking, servicing, repairing, complete overhauling and painting as and when required (but complete overhauling at least twice in a year and painting once in a year) and attending breakdown calls within 24 hours including replacement of all spare parts as per scope of work & special conditions per machine per year. Note: i) Cleaning and general maintenenece of Dryers shall have to be carried out as and when required or as per direction of Engineer-In-Charge, ii) Supply of spares which are included in this schedule shall be used for maintenance of Dryers as and when required. | 3 | per machine per year | 19,500 ₹23,010 | 25,500 ₹30,090 |
| 6.00 | Installation/shifting of window type AC with supplying wooden frame, fixing screws, hardware materials cement, sand as required to fix the frame including cutting pockets etc. | 8 | Nos. | 21,600 ₹25,488 | 6,400 ₹7,552 |
| 7.00 | Installation/shifting of split air conditioner with supplying al fixing materials, MS frame/pedestal for setting outdoor units as required to fix in dfferent locations | 8 | Nos. | 16,800 ₹19,824 | 9,600 ₹11,328 |
| 8.00 | Repairing of Microprocessor unit in split / Window type air conditioner Make-VOLTAS/LG/SAMSUNG / AJURE / LANCER as per direction of Engineer-in-charge for 2.0 Ton Capacity | 6 | Nos. | 5,400 ₹6,372 | 5,700 ₹6,726 |
| 9.00 | --do-- but for 1.5 Ton | 6 | Nos. | 5,400 ₹6,372 | 5,700 ₹6,726 |
| 10.00 | Repairing of Indoor unit Blower motor of window / split type air conditioner of 1.5 / 2 ton in all respect. Note: The repaired indoor unit blower motors shall be accepted by UCIL only after successful trial run at our site. | 5 | Nos. | 8,000 ₹9,440 | 4,250 ₹5,015 |
Tender Value
₹20.2 L
EMD Value
₹20,188
Closing Date
23 Mar 2026, 12:00 pmClosed
CHIEF SUPERINTENDENT (ELECT.)
URANIUM CORPORATION OF INDIA LIMITED, TURAMDIH MINES, PO-SUNDERNAGAR, EAST SINGHBHUM DISTRICT, JHARKHAND
Annual Contract for maintenance of window and split type air conditioners, water coolers and water cooler cum purifiers at Turamdih Mill
2026_UCIL_269332_1
TMD/1036
Open Tender
Electrical Works
365 days
TURAMIH MILL
AS PER PQC GIVEN IN TENDER DOCUMENT
7 documents required · 7 mandatory
₹500
Yes
Uranium Corporation of India Limited
₹20,188
Yes
9 May 2026
2 Mar 2026
24 Mar 2026
2 Mar 2026
23 Mar 2026
2 Mar 2026
Annual maintenance of window type air conditioner including checking, servicing, repairing, complete overhauling and painting as and when required (but complete overhauling at least twice in a year and painting once in a year) and attending breakdown calls within 24 hours including replacement of all spare parts as per scope of work & special conditions per machine per year. Note: i) Cleaning and general maintenenece of ACs shall have to be carried out as and when required .The frequency of this cleaning and Gen. maintenece shall be high in some places(dusty area) and may be low in some other places. This shall be carried out as per instruction of engineer incharge. ii) Supply of spares which are included in this schedule shall be used for maintenance of ACs as and when required.
Annual maintenance of split type air conditioner including checking, servicing, repairing overhauling and painting as and when required ( but complete overhauling at least twice in a year and painting once in a year) and attending breakdown calls within 24 hours including replacement of all spare parts as per scope of work and special conditions per machine per year. Note: i) Cleaning and general maintenenece of ACs shall have to be carried out as and when required .The frequency of this cleaning and Gen. maintenece shall be high in some places(dusty area) and may be low in some other places. This shall be carried out as per instruction of engineer incharge. ii) Suupply of spares which are included in this schedule shall be used for maintenance of ACs as and when required.
Annual maintenance of water coolers upto 300 litres including checking, servicing, repairing overhauling and painting as and when required (but at least twice in a year) and attending breakdown calls within 24 hours including replacement of all spare parts as per scope of work & special conditions per machine per year. Note: Supply of spares which are included in this schedule shall be used for maintenance of coolers as and when required.
Annual maintenance of water cooler cum purifiers of Make Eureka Forbes/equivalent, Aquaguard Model: PSS120 UV / equivalent model of upto 120 litres / equivalent including checking, servicing, repairing, overhauling as and when required (but at least three times in a year) and attending breakdown calls within 24 hours including replacement of all spare parts as per scope of work & special conditions per machine per year. Note: i) Painting (if required) once per year shall also be carried out by bidder as per direction of Engineer-In-Charge. ii) Supply of spares which are included in this schedule shall be used for maintenance of water coolers cum purifiers as and when required.
Annual Maintenance of Dryer of Air Compressor including checking, servicing, repairing, complete overhauling and painting as and when required (but complete overhauling at least twice in a year and painting once in a year) and attending breakdown calls within 24 hours including replacement of all spare parts as per scope of work & special conditions per machine per year. Note: i) Cleaning and general maintenenece of Dryers shall have to be carried out as and when required or as per direction of Engineer-In-Charge, ii) Supply of spares which are included in this schedule shall be used for maintenance of Dryers as and when required.
Installation/shifting of window type AC with supplying wooden frame, fixing screws, hardware materials cement, sand as required to fix the frame including cutting pockets etc.
Installation/shifting of split air conditioner with supplying al fixing materials, MS frame/pedestal for setting outdoor units as required to fix in dfferent locations
Repairing of Microprocessor unit in split / Window type air conditioner Make-VOLTAS/LG/SAMSUNG / AJURE / LANCER as per direction of Engineer-in-charge for 2.0 Ton Capacity
--do-- but for 1.5 Ton
Repairing of Indoor unit Blower motor of window / split type air conditioner of 1.5 / 2 ton in all respect. Note: The repaired indoor unit blower motors shall be accepted by UCIL only after successful trial run at our site.
Supply of new compressor of Rotary/ Reciprocating of 1-Phase / 3-Phase (as per requirement at site) of power saving model Kirloskar / Carrier / Tecumseh / LG make for window type and split type air conditioner (with proof of procurement from original manufacturer with Sl. No. etc.) inclusive of capillary, strainer, copper pipe etc. and its installation in place of defective compressor in the machine inclusive of dismantling, installation, gas charging with supply of gas, nitrogen flushing, washing etc. Note: The Compressor shall have to be approved by Engineer-In-Charge before supply.
--do-- but 1.5 ton compressor - Rotary
--do-- but 2.0 ton compressor - Rotary
--do-- but 1.5 ton compressor - Reciprocating
--do-- but 2.0 ton compressor - Reciprocating
--do-- but 3.0 ton compressor - Reciprocating, 415 volts 3 Ph.
Supply of new compressor of 1-Phase / 3-Phase (as per requirement at site) of power saving model Kirloskar / Carrier / Tecumseh / LG make for water cooler of capacity upto 3500 litres (with proof of precurement from original manufacturer with Sl. No. etc.) inclusive of capilarry, strainer, copper pipe etc. and its installation in place of defective compressor in the machine inclusive of dismantling, installation, gas charging with supply of gas, nitrogen flushing, washing etc. Note: The Compressor shall have to be approved by Engineer-In-Charge before supply.
Supply of Feron/Mefron-22 refrigerant in own certified cylinder & filling in machine
do but supply of Feron/Mefron-12
--do-- but supply of 134 A
--do-- but supply of R-404
--do-- but supply of R-410
Supply of capacitor Make-ASIAN/UNIVERSAL/HI-TECH as per direction of Engineer-in-charge
Supply of starting relay/contactor as per direction of Engineer-in-charge
Supply of Blower fan motor Make-FRAGMASTER/AMERICAN UNIVERSAL as per direction of Engineer-in-charge
Supply of Microprocessor unit of 1.5 Ton split air conditioner Make-VOLTAS/LG/ SAMSUNG / AJURE / LANCER as per direction of Engineer-in-charge
--do-- but of 2.0 Ton
Supply of Display / Sensor of PLC Kit
Supply of Brass Valve of Size: 5/8" used in Split AC as per following:
--do-- but Size: 1/2"
--do-- but Size: 1/4"
Supply of Indoor Unit complete with Remote Controller for 2.0 Ton split AC of Make: Cruiser / Voltas / LG / Bluestar / Samsung
--do-- but for 1.5 Ton
Supply of the copper pipe of Size: 5/8" suitable for Split AC
--do-- but of Size: 1/2"
--do-- but of Size: 1/4"
Supply of louver with motors as per direction of Engineer-in-charge
Supply of front grills for Split A.C. as per direction of Engineer-in-charge
Supply of front grills for Window A.C. as per direction of Engineer-in-charge
Supply of copper condensor for Split A.C. as per direction of Engineer-in-charge
Supply of copper condensor for Window A.C. as per direction of Engineer-in-charge
Base tray of window AC for LG, Voltas, Local, Blue Star Make
Runner for split AC for 3.0 tons
Runner for split AC for 2.0 tons
Runner for split AC for 1.5 tons
Window A.C.fan blade
Split AC fan blade
Repairing of 2.0 Ton reciprocating type compressure
Repairing of 1.5 Ton reciprocating type compressure
Supply of new Scroll Compressor of 3-Phase (as per requirement at site) of Capacity: 3.5 ton, BTU/Hr.: 36000 approx. of Model ZR40K3E-TFD-522AJQ, 3 Phase, 415 Volt, Suction Size: 20 mm, Discharge Size: 14 mm, Overall length: 420 mm, Overall width (diameter): 530 mm of Make: Emerson Copeland / Kirloskar / Danfoss for Dryer of Air Compressor (with proof of procurement from original manufacturer with Sl. No. etc.) inclusive of capillary, strainer, copper pipe etc. and its installation in place of defective compressor in the machine inclusive of dismantling, installation, gas charging with supply of gas, nitrogen flushing, washing etc. used gas-R22
Supply and fixing of hot gas bypass valve
Supply and fixing of refrigerant gas filter/dryer
Supply and fixing of Solenoid with timer and socket .
Supply and fixing of thermister display with delay time relay
Supply of Axial fan 3 Ph/single phase
Supply of new compressor of 1.5 ton - Rotary/Reciprocating Inverter type of 1-Phase / 3-Phase (as per requirement at site) of power saving model VOLTAS/Kirloskar / Carrier / Tecumseh / LG make for window type and split type air conditioner (with proof of procurement from original manufacturer with Sl. No. etc.) inclusive of capillary, strainer, copper pipe etc. and its installation in place of defective compressor in the machine inclusive of dismantling, installation, gas charging with supply of gas, nitrogen flushing, washing etc. Note: The Compressor shall have to be approved by Engineer-In-Charge before supply.
Supply of Microprocessor unit & PCB board of inverter type of 1.5 Ton split air conditioner complete set Make-VOLTAS/LG/ SAMSUNG / AJURE / LANCER as per direction of Engineer-in-charge
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.83 MB
Tendernotice_2.pdf
PDF • 0.57 MB
TenderDocTMD1036.pdf
Tender Documents • 1.82 MB
BOQ_313653.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid