Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.7 LAccepted-AOC | L1 | Accepted-AOC ADMITTED | |
| 2 | L2₹12.5 L+₹73,855 (6.30%)Accepted-AOC | L2 | Accepted-AOC ADMITTED | |
| 3 | L3₹12.7 L+₹98,790 (8.43%)Accepted-AOC | L3 | Accepted-AOC ADMITTED | |
| 4 | L4₹13.0 L+₹1.3 L (11.3%)Accepted-AOC 2 EVEREST VIHAR PT T N MISHRA MARG NIRMAN NAGAR JAIPUR 302019 | JAIPUR | RAJASTHAN | 302019 | L4 | Accepted-AOC ADMITTED | |
| 5 | L5₹15.0 L+₹3.3 L (28.2%)Accepted-AOC | L5 | Accepted-AOC ADMITTED |
Tender Value
Refer Docs
EMD Value
₹24,800
Closing Date
24 Sept 2020, 6:00 pmClosed
GE(A) Barmer
Military Engineer Services Garrison Engineer Army Jalipa Mil Stn Post box No 53 Barmer 344001
SPECIAL REPAIRS TO SEWAGE LINE AT MES CIV ACCN AT JALIPA MIL STN UNDER GE ARMY BARMER
2020_MES_372343_1
GE(A)/BMR-16 OF 2020-21
Open Tender
Miscellaneous Works
Item Rate
180 days
GE(A) Barmer
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE ARMY BARMER
₹24,800
Yes
31 Mar 2021
26 Aug 2020
28 Sept 2020
26 Aug 2020
24 Sept 2020
10 Sept 2020
Amount
Cleaning/taking out sludge/mud/silt from manhole and septic tanks of any size and capacity manually or mechanically including dewatering septic tank and manholes when ever required including removing of sludge/muds/silt in a closed container vehicle to a distance outside MD land and buried in pits by making necessary excavation for filling of sludge and covering by earth on top properly complete all as specified and as directed. Note :-Sludge/mud/silt shall be measured before taking out from manholes/septic tank.
Taking out muddy/ sewage water from soakage pit by using of mechanical sewage/mud water diesel pump set of 5HP power and dispossed off it through delivery pipe of required size more than 50 m away from soakage pits complete all as specified and as directed. Note:- All labour and T&P i.e. sewage water pump set, diesel, transportation of pump set from one place to other place, suction pipe, delivery pipe and manpower etc required for above work, shall be deemed included in unit rates quoted by the contractor and nothing extra shall be admissible on this account.
Cleaning of blockage sewage pipe line 100mm bore by roding from manhole to manhole and flushing with water, after cleaning and refixing the man hole cover complete all as specified and as directed.
Cleaning of blockage sewage pipe line 150mm bore by roding from manhole to manhole and flushing with water, after cleaning and refixing the man hole cover complete all as specified and as directed.
Removing of blockage from WC/floor trap/Nahani and line up to 1st manholes by opening grating and refixing after removing all greese, muds,sludge,silts etc complete all as specified and as directed.
Demolition and breaking up drain pipes (Salt glazed ware, AC or reinforced concrete) of 150mm bore set in cement mortar complete all as specified and as directed. Note :- Excavation and earth work shall be measured and paid separately.
S & F 150 mm bore Reinforced cement concrete pipes, one end socketed, class NP2, laid in trenches and jointed in cement mortar 1:1 with collar complete all as specified and as directed .
M&L PCC 1:4:8 type D-2 (using 40 mm graded crused stone aggregate) as in bed to 150 mm bore RCC drain pipe including packing under and haunching against the side of pipe after they are laid and tested complete all as specified and as directed.
S & F 200 mm bore Reinforced cement concrete pipes, one end socketed, class NP2, laid in trenches and jointed in cement mortar 1:1 with collar complete all as specified and as directed .
M&L PCC 1:4:8 type D-2 (using 40 mm graded crused stone aggregate) as in bed to 200 mm bore RCC drain pipe including packing under and haunching against the side of pipe after they are laid and tested complete all as specified and as directed.
Demolition and breaking up drain pipes (Salt glazed ware, AC or reinforced concrete) of 100mm bore set in cement mortar complete all as specified and as directed. Note :- Excavation and earth work shall be measured and paid separately.
S & F sand cast, cast iron, soil / waste / vent pipes, 100mm bore, in any length with or without ears, jointed with cement sand mortar, laid in trenches ot floors complete all as specified and as directed.
Site clearance including clearing away all grass vegetation, saplings,shrubs, brushwood, undergrowth,roots,and trees not exceeding 30 cm in girth( measured at a height of one meter above ground level) and removing entire rubbish out side MD land complete all as specified and as directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation etc or for shaft, wells, cesspits, manholes, pier holes etc not exceeding 10 sqm on plan and getting out in any type of soil complete all as specified and as directed .
Excavation in trenches not exceeding 1.5m wide and depth exceeding 1.5m but not exceeding 3.00 m for foundation etc or for shaft, wells, cesspits, manholes, pier holes etc not exceeding 10 sqm on plan and getting out in any type of soil complete all as specified and as directed .
Excavation in over areas and depth exceeding 3.0 m but not exceeding 4.5 m and getting out in soft disintegrated rock complete all as specified and as directed .
Returning filling in including spreading , leveling , watering and well ramming in layer n. exc 25 cm thick as in soils complete all as specified and as directed.
Removing surplus excavated soil to a distance not exceeding 50 mtr and depositing where directed at a level n. exc. 1.50 mtr above the starting point complete all as specified and as directed.
Demolition of cement concrete (unreinforced) of any description and in any position not other wise specifically provided and removal unserviceable materials, debris and rubbish to a distance out side MD land complete all as specified and as directed.
M&L PCC 1:4:8 type D2 (using 40 mm graded crushed stone aggregate) as in foundation , filling and mass concerete complete all as specified and as directed.
Demolition of brick / block or stone / boulder masonry walling built in cement mortar including all quoins arches pillars etc and removal unserviceable materials, debris, rubbish to out side MD land complete all as specified and as directed.
M&L precast cement concrete 1:3:6 type C-1 using 20mm graded stone aggregate as in solid block masonry exceeding 10cm width and setting in cement mortar 1:6 complete all as specified and as directed .
M & L walling of random rubble masonry,well bonded ,bedded and solidly hearted built in cement mortar 1:6 complete all as specified and directed.
M & L walling of random rubble masonry,well bonded ,bedded and solidly hearted built in cement mortar 1:6 except stone complete all as specified and directed.
M&L PCC (1:2:4) type B-1 using 20 mm graded crushed stone aggregate as in benching/ channels of manholes etc including necessary form work complete all as specified and as directed .
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement including forms , moulds , mitred/stopped ends etc. complete all as specified and as directed .
Add or deduct from above item No. 26 for each 25 mm girth or part there of over or under 30 cm (item is for adjustment of rate).
M & L PCC 1:2:4 type B-1 (20mm graded crushed stone aggregate) as in coping including necessary form work complete all as specified and as directed.
M&L 15 mm thick rendering in cement mortar 1:4 on stone masonry surfaces mixed with water proofing compound as per manufacturer instructions and finished the surfaces fair and even with out using extra cement complete all as specified and as directed. Note :- WPC will be measured and paid seperately.
Supply only water proofing compound (ISI Marked)
M&L rendering 10 mm thick cement plaster in cement mortar 1:4 on fair faces of brick work or concrete surfaces finished fair and even without using extra cement complete all as specified and as directed .
Demolition of cement concrete reinforced in manhole covers in any position not other wise specifically provided and removing debris and rubbish out side MD landcomplete all as specified and as directed.
M&L for precast cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate in landings, cover slabs (for man holes etc) chullah hoods,chajjas,water troughs,shelves and similar articles with plain faces complete all as specified and as directed .
M&L mild steel TMT bars 6 to 8mm dia , cut to length, bend to shape required, including cranking, bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
M&L Mild steel round bars 10 mm dia and over cut to length, bent to shape as in handle of RCC cover slab of manholes complete all as specified and as directed .
S&F Cast iron work grade FG 150, article n. exc 5 kg each, unmachined, in brackets, gully traps, gratings, railing, frames, manhole covers, fire and soot doors, dampers, stop valve boxes, gate stops,parts of ranges, balusters and similar articles complete all as specified and as directed.
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel [½ round or ¾ section] in cement concrete 1:2:4 type B1 smooth finished, and reforming benching as required for 150 mm dia of pipe complete all as specified and as directed.
Cutting into existing manholes for removing existing branch drain, making good to walling and rendering, cutting out branch channel and making good benchings as required for 150 mm dia of pipe complete all as specified and as directed.
S & F in repairs sand cast, cast iron, soil / waste / vent pipes, 100mm bore, in any length with or without ears, jointed with cement sand mortar, fixed to walls with and including MS clamps complete all as specified and as directed.
S & F in repairs sand cast, cast iron, soil / waste / vent pipes, 75mm bore, in any length with or without ears, jointed with cement sand mortar, fixed to walls with and including MS clamps complete all as specified and as directed.
S & F cast iron vent cowls suitable for 100mm dia pipes complete all as specified and as directed.
S & F cast iron branch pieces with ovall access door, single [equal or unequal] ordinary or inverted [spigot and socketed type] or with parallel branches suitable for 100mm dia pipes complete all as specified and as directed.
S & F cast iron branch pieces with ovall access door, single [equal or unequal] ordinary or inverted [spigot and socketed type] or with parallel branches suitable for 75mm dia pipes complete all as specified and as directed.
S & F cast iron bends with ovall access door [any radius], diminishing pieces or tapers [larger bore measured] of 100mm bore, for cast Iron soil / waste / vent pipes complete all as specified and as directed.
S & F cast iron bends with ovall access door [any radius], diminishing pieces or tapers [larger bore measured] of 75mm bore, for cast Iron soil / waste / vent pipes complete all as specified and as directed.
S&F in repair 100mm dia out let, cast iron floor trap with grating including jointing to waste pipe fixed in cement concrete 1:2:4, Type B-1 complete all as specified and as directed.
S&F in repair 75mm dia out let, cast iron floor trap with grating including jointing to waste pipe fixed in cement concrete 1:2:4, Type B-1 complete all as specified and as directed.
S & F in repairs cast iron ' Y ' joint for 100mm bore complete all as specified and as directed.
S & F in repairs cast iron ' T' joint for 100mm bore complete all as specified and as directed.
M.D. CONSTRUCTION CO.
Kusum Traders
Rasam Engg Co.
SOHANLAL MOHTTA
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .