Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.6 LAccepted-AOC FLAT NO 4 VIRGINIA CO OP HOUSING SOCIETY AIR PORT ROAD CHICALIM VASCO DA GAMA GOA 403 711 | SOUTH GOA | GOA | 403711 | ₹31.6 L Quoted ₹31.7 L | L1 | Accepted-AOC BEING L1 |
| 2 | L2₹32.8 L+₹1.1 L (3.38%)Rejected-Finance | ₹32.8 L+₹1.1 L (3.38%) | L2 | Rejected-Finance NOT BEING L1 |
| 3 | L3₹36.0 L+₹4.3 L (13.4%)Rejected-Finance C2 PAIXOMONTIRO APTS BEHIND NSD ALTO DABOLIM VASCO DA GAMA GOA 403 801 | SOUTH GOA | GOA | 403801 | ₹36.0 L+₹4.3 L (13.4%) | L3 | Rejected-Finance NOT BEING L1 |
| 4 | L4₹37.0 L+₹5.2 L (16.4%)Rejected-Finance | ₹37.0 L+₹5.2 L (16.4%) | L4 | Rejected-Finance NOT BEING L1 |
| 5 | L5₹37.0 L+₹5.3 L (16.5%)Rejected-Finance | ₹37.0 L+₹5.3 L (16.5%) | L5 | Rejected-Finance NOT BEING L1 |
Tender Value
₹43.4 L
EMD Value
₹86,900
Closing Date
24 Nov 2023, 6:00 pmClosed
Garrison Engineer (I) (CG) Goa
Garrison Engineer (I) (CG) Goa HQ Coast Guard DHQ-11 Chicolna PO- Bogmalo Goa 403806
REPAIR AND REPLACEMENT TO ROOF TREATMENT, FALSE CEILING, REPLACEMENT OF EXISTING TILES WITH GRANITE AT BUILDING NO P-415 AND P-663 AT CGAE TECHNICAL AREA GOA AND ALLIED WORKS UNDER GE(I)(CG) GOA
2023_MES_624907_1
8423/GOA/E8
Open Tender
Miscellaneous Works
Item Rate
210 days
CGAE TECH AREA AT GOA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Garrison Engineer (I) (CG) Goa
₹86,900
Yes
25 Jan 2024
25 Oct 2023
2 Dec 2023
25 Oct 2023
24 Nov 2023
9 Nov 2023
25 Oct 2023 - 1 Nov 2023
Amount
M & L Providing and fixing Gypsum board 12mm thick of size 600mm x 600mm ceiling boards fixed with screws over Anodised aluminium snap grid frame work including hangers 6mm dia G I(up to 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flay 40 x3 mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long including dismantling of old unserviceble ceiling boards (Fibre , pulp, insulation etc) or insulation board/ slabs/ AC Plain sheets/ blankets any thickness all as specified and directed
M & L Providing and fixing 10mm thick plaster of paris ceiling (Gypsum anhydrous) to flat surface over anodised aluminium snap grid frame work for false ceiling in decorative manner including hangers 6mm dia G I(up to 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made outof GI flay 40x3 mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long including dismantling of old unserviceable false ceiling complete all as specified and directed
M & L rendering 10mm thick in cement mortar (1:6) on fair faces of brickwork or concrete surfaces, finished the surface even and smooth without using extra cement including taking down of old unserviceble plaster complete all as specified and directed.
M & L preparation of new plastered surfaces of wall and applying 3mm wall care putty with two coats of oil bound distemper over a coat of alkali resistant primer complete all as specified and directed.
M & L applying water proofing treatment with the following stages/specification for in accecceble roof complete all as specified and directed:- STAGE 1:- Removal of existing roof treatment consisting of screed bed, tar felts etc including removal of debris to a distance exc 1.5 Km but n exc 2Km, STAGE 2:- Brushing neat cement slurry with 3.0 kg of cement per sq meter complete all as specified and directed. STAGE 3:- 10mm thick cement rendering in cement mortar 1:4 over green neat cement slurry to receive roof treatment and finished even and smooth without using extra cement mixed with water proofing compound(ratio WPC and cement as per manufacture instructions) as in grading to RCC roof surface complete all as specified and directed. Note- water proofing compound shall be measured and paid separately). STAGE 4:- Applying bitumen primer for bitumen membrane shall have density at 25 C (degree) in the range of 0.87-0.89 kg/li and viscosity of 70-160 CPS primer shall be appplied @ of 0.40li/ Sqm at top and bottom of the membrane as bonding material STAGE 5:- M & L Water proofing roof treatment, consisit of a five layered Atactic polypropylene modified polymeric membrane of minimum 3 mm thick and minimum weight not less than 3.5 Kg/sqm, reinforced with polyster non woven fabric matt (weight not less than 150 gm/sqm), laid with LPG torch forced application over roof surface, with a side & end overlaps of minimum 100 mm. STAGE 6:- A coat of solar reflective bbituminous aluminium primer @ 100 gm/Sqm on top, including sealing all joints by thermo fusion, and one coat silver paint on it all as per manufacturer's instructions
M & L applying water proofing treatment with the following stages/specification for accessible roof complete all as specified and directed. STAGE 1:- Removal of existing roof treatment consisting of screed bed, PCC tiles tar felts etc including removal of debris to a distance exc 1.5 Km but n exc 2Km, STAGE 2:- Brushing neat cement slurry with 3.0 kg of cement per sq meter complete all as specified and directed. STAGE 3:- 10mm thick cement rendering in cement mortar 1:4 over green neat cement slurry to receive roof treatment and finished even and smooth without using extra cement mixed with water proofing compound(ratio WPC and cement as per manufacture instructions) as in grading to RCC roof surface complete all as specified and directed. Note- water proofing compound shall be measured and paid separately). STAGE 4:- Applying bitumen primer for bitumen membrane shall have density at 25 C (degree) in the range of 0.87-0.89 kg/li and viscosity of 70-160 CPS primer shall be appplied @ of 0.40li/ Sqm at top and bottom of the membrane as bonding material STAGE 5:- M & L Water proofing roof treatment, consisit of a five layered Atactic polypropylene modified polymeric membrane of minimum 3 mm thick and minimum weight not less n 3.5 Kg/sqm, reinforced with polyster non woven fabric matt (weight not less than 150 gm/sqm), laid with LPG torch forced application over roof surface, with a side & end overlaps of minimum 100 mm. STAGE 6: A separation layer of Geotextile 120gsm Non- woven 100% polyester of thickness 1.0 to 1.25mm bonded to the APP membrane with intermittant touch by haeting the membrane by Butane torch as per manufacturing instructions. STAGE 7:- PCC Tiles of 20cmx 20cmx 20mm thick provide over 20mm rendering in Cement Mortar (1:4) set and joined over geo textile complete all as per manufacturees instruction STAGE 8:- A coat of solar reflective bituminous aluminium primer @ 100 gm/Sqm on top, including sealing all joints by thermo fusion, and one coat silver paint on it all as per manufacturer's instructions
Supply only integral water proofing compound for plastering / concrete work, complete all as specified as directed
S & F Rotational moulded polyethylene water storage tanks of 1000 Ltrs capacity (cylindrical, vertical with closed top) minimum three layered hoisted and fixed in position including 20mm bore PVC float valve including dismantling of old unserviceble water tank complete all as specified and directed.
S & F in repairs Gun metal gate/globe valve, with iron wheel head, screwed both ends for iron pipes 20mm bore complete all as specified and directed.
S & F in repairs 20mm bore medium grade galvanized steel tubes with all fittings and fixed to wall and celing or laid in floors including taking down of old unserviceble pipe etc complete all as specified and directed.
M & L Granite (of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cementwith admixture of pigment to match the shade of granite stone including grinding and polishing complete and including 20mm thick screed bed or bedding layer in Cement Mortar (1:6) including taking down of old unserviceble floor or wall with cement mortar complete all as specified and directed.
M & L 20mm thick Granite (of any type) tiles machine cut (table rubbed and polished) in steps, jambs, pillars, win dow-cills, cooking plat forms and like in cement mortar (1:4) including point ing in white cement (1:2) us ing marble dust with admix ture of pigment to match including grinding and polishing complete and including 15mm thick rendering in cement mortar (1:4) including taking down of old unserviceble floor or wall with cement mortar complete all as specified and directed.
M & L Non-skid ceramic coloured tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but n.exc. 0.18 sqm as in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles over and including 15mm thick screed bed or bedding layer in Cement Mortar (1:6) including taking down of old unserviceble floor or wall with cement mortar complete all as specified and directed.
M & L double charged Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement including 15mm thick screed bed or bedding layer in Cement mortar (1:6) including taking down of old unserviceble floor or wall with cement mortar complete all as specified and directed.
Demolition of brickwork /PCC blocksbuilt in cement mortar including all quoins, arches, pillars etc complete all as specified and directed.
Taking down chowkat or frames n exc 1.5 Sqm each (w/o taking of shutters from the frame ).complete all as specified and directed.
S & F Aluminium powder coated doors, window consisting of stranded section for frames including necessary handles, roller wheels, hinges rubber beading etc complete all as specified and directed
M & L Powder coated Anodised aluminium door shutters aluminium section weighing 0.55 Kg /M including necessary joining cleats glazing clips rubber neoprene packing handles etc (min thickness of powder coating should be 50 micron) complete all as specified and directed.
S & F 12mm thick Toughned glass as in hinged doors, partitions automatic doors and similar work including cutting to shape, drilling holes required incl 2 nos of 200mm long Stainless steel Handle, including all accessories complete all as specified and directed.
S & F Sheet glass, 6.3 mm thick ordinary quality in square exc 0.5 sqm in each pane fixed with rubber/alluminium bedding with extra over sheet glass is ground or obscured with solar control film 25 micron reflective type to glass panes complete all as specified and directed.
S & F Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed all complete all as specified and directed
S & F Powder coated aluminium barrel tower bolts of extruded section 150mm long complete all as specified and directed.
S & F Powder coated aluminium, fabricated type handle, 150mm long all as specified and as directed
Taking down carefully old existing batten/PVC casing capping (or) conduit point aluminium/copper wiring i.e light, fan, Bell, socket including batten/ casing/ conduit,switch boards, laminated sheets, round blocks, MS Sunken boxes, light fittings/holders, fan regulator of any type, other fittings & fixtures and making good the disturbed surfaces, walls, floors and stair cases complete all as specified and directed.
Taking down unserviceable sub main wiring from existing batten/ PVC concealed conduit / casing & caping of any size complete all as specified and directed.
Taking down fan, sealing cable end, dismantling blades and removing fan and blades to store and refixing the same after painting with two coats of synthetic enamel paint complete all as specified and directed.
M & L Point wiring with 1.5 Sq mm copper conductor single core FRLS PVC insulated unsheathed 1100 Volts multistranded drawn through and including rigid PVC conduit and its accessories, concealed in wall/ceiling of suitable size, ISI marked and Sunken box of suitable size including fixing/grouting sunken/ surface as per site requirement for mounting modular switches / sockets/ regulators etc including running up of 1.5 Sq mm copper conductor FRLS PVC insulated cable as earth continuity conductor along with wiring and connecting to the common earth dolly complete all as specified and directed.
(a) One light/ Fan point controlled by one, one way switch 5/6 Amp complete all as specified and directed.
(b) One socket point 2/3 Pin 5/6 Amp on same board complete all as specified and directed.
(c) One socket point 2/3 pin, 5/6 Amp on Independent board complete all as specified and directed.
All as per item No 34.00 here-in-before but with PVC FRLS insulated unsheathed multi stranded copper conductor of size 2.5 Sqmm, 1100V grade for 2/3 pin 6/16Amps switch socket on independent board with PVC FRLS insulated unsheathed copper conductor of size 4 sqmm using as earth continuity wire and connected to common earth dolly complete all as specified and directed.
S & F Modular switch 1 way 6A, 1 module complete all as specified and directed.
S & F Modular Socket, 6A - 2/3 pin combined 2 module complete all as specified and directed.
S & F Modular socket 1 way 16A, 1 module complete all as specified and directed.
S & F Modular switch 1 way 16A complete all as specified and directed.
S & F Modular fan step regulator, 2 module complete all as specified and directed.
M & L Ceiling rose 3 terminals/ PVC polycarbonate isolated body size (65x50) mm surface type, 230V complete all as specified and directed.
S & F in repairs LED tube light fitting 1 x 18 W, 230V wall mounted integrated batten, 4 ft LED module fixed on wall/surface/ceiling shall confirm to IS 16103 and shall bear BIS certification marking complete with all accessories internally pre- wired and including connecting up with twin core twisted flexible copper conductor cable with suitable sizes complete all as specified and directed.
S & F 1 x 36 efficient LED recessed 2'x2' luminaire to enhance with comfortable experience through its classic design & glare free soft illumination, internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size in PVC conduit complete all as specified and directed.
M & L Submain wiring with 2 runs of single core 4 sqmm PVC insulated unsheated multistranded 1100 volts grade with copper conductor drawn through and including PVC conduit marked and accessories concealed in wall/ceiling including one run of single core 4 sqmm PVC insulated unsheated multistranded 1100 volts grade with copper conductor cable as earth continuty conductor along with the wiring and connected from DB to DB/ main board complete all as specified and directed.
S & F in repairs MCB DB SPN double door 12 way sheet metal enclosure SPN 240 V 50 Hz horizontal with IP-42 degree protection complete all as specified and directed.
S & F in repairs MCB SPN 06 to 32 Amp, 230 volts, complete all as specified and directed.
S & F in repairs MCB SP 'C' series 06 to 32 Amp, 230 volts, complete all as specified and directed.
M & L Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, using galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and directed.
STAR FABRICATION
M/S P S BABU
M/S Kartik Enterprises
Mehta and Co.
Tiwarinassociates
M/s RAJ CONSTRUCTION
KVL CONSTRUCTION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .