Disconnecting electrical connection
Flushing of borewell
Replacement of GI coloum pipe
Rewinding of submersible pump
Rewinding of submersible motor
Replacement the worn out Parts
Refixing submersible pump after repair
Replacement of submersible cable
Replacement of submersible pump starter
Replacement of earthing
Repair of lorry filling point
Replacement of electric power cables aluminium conductor of size 25 sq mm 4 core
Supply fixing lowering MS reducer bail plug well cap MS strip for centering MS iron clamps electric logging
3589530
GEM/2022/B/2351329
Disconnecting electrical connection,Flushing of borewell,Replacement of GI coloum pipe,Rewinding of
10 days
Ladakh; Leh Ladakh
Total value wise evaluation
BOQ
1 document required · 1 mandatory
Exempted
27 Jul 2022
15 Jul 2022
25 Jul 2022
| Item No | Item Title | Description | Qty | Unit | Consignee | Delivery (days) |
|---|---|---|---|---|---|---|
| 1 | Disconnecting electrical connection | Disconnecting electrical connection from the starter panel for submersible pump set upto 7.5 HP capacity taking up motor and pump set including coloumn pipe from bore well for repair of unserviceable submercible pump motor replacement cleaning of coloumn pipe replacement of submercible cable and after repair of motor pump/replacement of column pipe replacement of submercible cable reinstalling the same and making necessary electrical connection | 1 | pieces | Leh | 10 |
| 2 | Flushing of borewell | M L for flushing of borewell complete by using 210 CMF compressor and heavy duty driller machine to deliver the high air pressure at the bottom of the bore well and cleaning flushing the bore well till the water is become free from any mud and clear for portable | 1 | pieces | Leh | 10 |
| 3 | Replacement of GI coloum pipe | Material and labour for replacement of GI coloum pipe 50 mm dia medium grade 3 Mtrs in length, both end flanged including nuts bolts washer and rubber gaskets etc | 10 | pieces | Leh | 10 |
| 4 | Rewinding of submersible pump | M L for taking out us electric driven pumping set of capacity upto 7.5 HP dicharge 3 LPS head 70 to 80 meters alongwith GI coloum pipe 50 mm bore flanged at both side and submersible cable from bore for repair rewinding the submersible pump set | 1 | pieces | Leh | 10 |
| 5 | Rewinding of submersible motor | M L for split opening the submesible motor upto 7.5 HP capacity and taking out worn out winding and rewinding with copper winding wire as per existing gauge including overall insulation and including replacement of defective parts intermediate sheet bottom and top thrust plate support bush oil seal diaphram O ring Key sand guard and stud and nut complete reassembling the motor | 1 | pieces | Leh | 10 |
| 6 | Replacement the worn out Parts | M and L for split opening the submessible pump multi stage 3 phase upto 7.5 HP capacity and replacing the worn out shaft sleeve impeller bearing bushes etc and M L for machining remetalling grinding etc the shaft and turning polishing to shaft supply and fixing suitable size gun metal bushes etc reassembling the pump | 1 | pieces | Leh | 10 |
| 7 | Refixing submersible pump after repair | M L for lowering the submersible electric dirven pump set of capacity upto 7.5 HP discharge 3 LPS 70 to 80 meters head alongwith GI coloum pipe 50 mm bore flanged both side old new GI pipe lowering the pump and motor including transporting testing and commissioning etc | 1 | pieces | Leh | 10 |
| 8 | Replacement of submersible cable | Supply and Fixing in replacement of PVC insulated and PVC sheathed cable with electrolytic grade annealed copper conductor of size 10 Sqmm 3 core for submersible Pump Motors voltage up to and including 1100 Volts conforming generally conforming to IS 69 | 90 | RM | Leh | 10 |
| 9 | Replacement of submersible pump starter | S F in replacement direct on line submersible pump stater 3 phase 415 V suitable for upto 7.5 HP | 1 | pieces | Leh | 10 |
| 10 | Replacement of earthing | Repair Replacement of earthing complete with galvanised steel earth plate electrode 60 60cm 6mm thick buried directly in ground earth pit not less than 2.25 metres deep below ground level with top edge of the plate not less than 1 5 metres below normal ground level, connected to galvanised earth lead wire 4 mm dia by means of bolts nuts check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 connected to earthing test point all as specified or indicated including testing on completion | 1 | pieces | Leh | 10 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_3589530.pdf
GEM_BID
new-document-141_2022-07-15-14-17-47_536a93c80115f126814eab277df08d88.pdf
BOQ
boq_item_sample_file-borewell-base_2022-07-15-14-17-47_da84904a5814fc34d659626eccc29960.csv
BOQ
OTHER
gtc.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .