| 1 | L1₹16.9 LAccepted-AOC 44B CIRCULAR GARDEN REACH ROAD KOLKATA 700 023 | KOLKATA | WEST BENGAL | 700023 | L1 | Accepted-AOC Being L1 bidder. | |
| 2 | L2₹17.6 L+₹71,362 (4.23%)Rejected-Finance | L2 | Rejected-Finance Rejected due to higher than L1 bidder. Amount considered after deduction of schedule of credit amount i.e. Rs. 88200.00 | |
| 3 | L3₹18.1 L+₹1.2 L (7.05%)Rejected-Finance P 45 KHIRODE VIDYA BINOD AVENUE KOLKATA 700003 | KOLKATA | WEST BENGAL | 700003 | L3 | Rejected-Finance Rejected due to higher than L1 bidder. Amount considered after deduction of schedule of credit amount i.e. Rs. 88200.00 | |
| 4 | L4₹18.6 L+₹1.8 L (10.5%)Rejected-Finance 1 9 | PRAYAGRAJ | UTTAR PRADESH | 211001 | L4 | Rejected-Finance Rejected due to higher than L1 bidder. Amount considered after deduction of schedule of credit amount i.e. Rs. 88200.00 | |
| 5 | L5₹20.0 L+₹3.1 L (18.4%)Rejected-Finance | L5 | Rejected-Finance Rejected due to higher than L1 bidder. Amount considered after deduction of schedule of credit amount i.e. Rs. 88200.00 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
1 Dec 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE CENTRAL, KOLKATA
Garrison Engineer (Central) Kolkata, T-37, Napier Road, Hastings, Kolkata-700022
REPAIR REPLACEMENT OF INTERNAL ELECTRIFICATION INCLUDING REPAIR TO FANS AND WATER HEATERS IN BLDGS AT BMC AREA UNDER GE CENTRAL KOLKATA
2020_MES_394197_1
8307
Open Tender
Miscellaneous Works
Item Rate
270 days
Kolkata
As per tender documents
10 documents required · 10 mandatory
₹500
GE CENTRAL KOLKATA
₹50,000
Yes
27 Jan 2021
10 Nov 2020
3 Dec 2020
10 Nov 2020
1 Dec 2020
26 Nov 2020
10 Nov 2020 - 25 Nov 2020
60 days
Amount
Taking down carefully any type of point wiring (light, fan, bell, socket or power) complete including fixture and fitting such as switches, ceiling roses, pendents, regulators, sockets, light fittings etc stacking at site for reuse of serviceable items and removal of unserviceable items from site and making good disturbed faces of walls, ceiling, floor etc to match with the existing surface complete all as specified and directed by the Engineer-in-charge.
Material and labour Point wiring with PVC insulated and unsheathed FRLS cable single core multistranded copper conductor 1.5 Sqmm size, 1100 volts grade cable confroming to IS - 694 1990 drawn through and including PVC casing and caping of suitable size with all accessories including fabricated MS terminal boxes fixed flush with wall surface with 3 mm thick plastic masonite laminated sheet top cover fixed with cadmium screw for mounting switches, sockets, regulator etc including 1.5 Sqmm multistranded PVC insulated and unsheathed copper conductor FRLS type as earth continuity conductor to common earth and connecting to earth dolly all as specified for One light / ceiling fan / bell point / 3 pin 5 Amps Socket outlet point controlled by one switch single pole one way complete all as specified and as directed.
All as per item No. 2.00 here in-before but for one 3 pin 5 amps socket outlet on the same board with other switch for surface / conduit wiring with casing caping / PVC conduit complete all as specified and directed by Engineer in-charge.
All as per item No. 2.00 here-in-before but using 2.5 Sqmm FRLS type , stranded copper conductor cable for one 16 Amp switch socket outlet on independent board complete all as specified and directed by Engineer-in-Charge.
Material and Labour Point wiring with 1.5 Sqmm (nominal area), FRLS PVC insulated, multistranded, single core, unsheathed, copper conductor cables drawn through and including PVC conduits Concealed in walls, ceiling etc with all fittings and accessories of PVC conduits (like Tee, bend etc.) complete fixed to walls/ceiling etc. with and including 1.5 Sqmm (nominal area) FRLS PVC insulated, unsheathed, multistranded, single core, copper cable green in colour as in earth continuity wire connecting to common earth point and 1.6 mm thick mild steel sunken terminal boxes of suitable size with 3 mm thick hylam sheet top cover fixed with suitable size of brass screws for mounting switches, sockets, regulators etc complete for one light/fan/bell/buzzer point/ 3 pin 5 Amps socket outlet point controlled by one, one way switches complete including cutting, chasing the surface and then making good the same in CM 1:3 complete all as specified and directed by the Engr-in-Charge.
All as per item No. 5.00 here in-before but for one 3 pin 5 amps socket outlet on the same board with other switch complete all as specified and directed by Engineer in-charge.
All as per item No. 5.00 here-in-before but using 2.5 Sqmm size, FRLS type stranded copper conductor cable for one 16 amp switch socket outlet on independent board complete all as specified and directed by Engineer-in-Charge.
Supply & fix Switch piano, flush type, SP, one way, 5/6 Amps 230 Volts complete all as specified and as directed.
Supply & fix in repairs Switch piano, flush type, SP, one way, 5/6 Amps 230 Volts complete all as specified and as directed.
Supply & fix Bell/buzzer push 5/6 Amps, flush type, white/ivory finish complete all as specified and as directed.
SSupply and fix in repairs Switch socket combination multipurpose 2 in 1, 3 pin 6 Amps 240 volt flush type complete all as specified and as directed.
Supply and fix in repirs Socket outlet , 2 in 1, 3 pin, 6 Amps, 240 volt flush type complete all as specified and as directed.
SSupply and fix Switch socket combination multipurpose 2 in 1, 3 pin 6 Amps 240 volt flush type complete all as specified and as directed.
Supply and fix Socket outlet , 2 in 1, 3 pin, 6 Amps, 240 volt flush type complete all as specified and as directed.
Supply and fix in repairs Switch socket combination multipurpose 2 in 1, 3 pin 5 & 15 Amps 240 volt flush type complete all as specified and as directed.
Supply and fix Switch socket combination multipurpose 2 in 1, 3 pin 5 & 15 Amps 240 volt flush type complete all as specified and as directed.
Supply and fixing Lamp holder suitable for batten fittings complete all as specified and directed by the Engr-in-Charge.
Supply and fixing in repairs Lamp holder suitable for batten fittings complete all as specified and directed by the Engr-in-Charge.
Supply and fix Ceiling rose surface Bakelite three terminals 230 volts complete all as specified and as directed.
Supply and fix in repairs Ceiling rose surface Bakelite three terminals 230 volts complete all as specified and as directed.
Supply and fix in replacement Call bell ding dong AC 230 volts, single pole complete all as specified and as directed.
Supply & fix Electronics fan regulator, step type, AC 120/280 volt, white/ivory finish complete all as specified and as directed.
Supply & fix in repairs Electronics fan regulator, step type, AC 120/280 volt, white/ivory finish complete all as specified and as directed.
Supply & fix in repairs Modular type switch 6 Amps 230V AC single module one way complete all as specified and as directed. Make:-Anchor / Havells / Legrand.
Supply & fix in repairs Modular type switch 20 Amps 230V AC two module one way complete all as specified and as directed. Make:- Anchor / Legrand / Havells.
Supply & fix in repairs Modular socket outlet 6 Amps 3 Pin shuttered type 230V AC 2 module complete all as specified and as directed. Make:-Anchor / Havells / Legrand.
Supply & fix modular in replacement socket outlet 10/20 Amps 3 Pin shuttered type 230V AC 2 module complete all as specified and as directed. Make:- Anchor/Legrand / Havells.
Supply & fix in repairs modular bell push, 6/10 Amps 230V AC single module complete all as specified and as directed. Make:- Anchor / Legrand / Havells.
Supply & fix in repair modular type fan regulator Step type ,100 Watt, one module, 230V AC single module complete all as specified and as directed. Make:- Anchor /Legrand / Havells.
Supply & fix in repair modular type fan regulator Step type ,100 Watt, two module, 230V AC single module complete all as specified and as directed. Make:- Anchor / Legrand / Havells.
Supply & fix in repair modular cover plate with frame for fixing of modular switches/sockets complete for 1 modules complete all as specified and as directed. Make:- Anchor / Legrand / Havells.
All as per item No 31.00 here-in-before but for 2 modules. Make:-Anchor / Legrand / Havells.
All as per item No 31.00 here-in-before but for 3 modules. Make:- Anchor / Legrand / Havells.
All as per item No 31.00 here-in-before but for 6 modules. Make:- Anchor / Legrand / Havells.
All as per item No 31.00 here-in-before but for 8 modules. Make:- Anchor / Legrand / Havells.
All as per item No 31.00 here-in-before but for 12 modules. Make:- Anchor / Legrand / Havells.
Supply & fix in repair sunken flush metal GI boxes for fixing of modular switches/sockets flush to the walls. 1 Module/ 2 Module complete for modules complete all as specified and as directed.
All as per item No 37.00 here-in-before but for 3 modules.
All as per item No 37.00 here-in-before but for 4 modules.
All as per item No 37.00 here-in-before but for 6 modules.
All as per item No 37.00 here-in-before but for 12 modules.
Supply and fix Power supply unit consisting of starter with 11-18 Amp over load protection, MCB of 25 Amp with socket complete for AC 240 Volt single phase including taking down old unserviceable one complete all as specified and directedby Engr-in-Charge. Make:Havells/L&T/Legrand/Schneider/Northwest/C&S.
Supply and fix Sheet metal enclosure Metal Door for DB's where MCBs to be used 4 way single pole and neutral with 200 amps rated bus bar including taking down old unserviceable DB complete all as specified and as directed. Note:- (1) Quoted rates are inclusive of taking down DB including MCBs. (2) Found Unserviceable MCBs will be contractor property and will be measured under Schedule of Credit.
Supply and fix Sheet metal enclosure Metal Door for DB's where MCBs to be used 8 way single pole and neutral with 200 amps rated bus bar including taking down old unserviceable DB complete all as specified and as directed. Note:- (1) Quoted rates are inclusive of taking down DB including MCBs. (2) Found Unserviceable MCBs will be contractor property and will be measured under Schedule of Credit.
Supply and fix Sheet metal enclosure Metal Door for DB's where MCBs to be used 12 way single pole and neutral with 200 amps rated bus bar including taking down old unserviceable DB complete all as specified and as directed. Note:- (1) Quoted rates are inclusive of taking down DB including MCBs. (2) Found Unserviceable MCBs will be contractor property and will be measured under Schedule of Credit. (3) Found Serviceable MCBs will be taken into safe custody for reuse under relevent item of this Schedule.
Supply and fix MCB 6 to 32 Amps, SP, 240 Volts , 'C' curve braking capacity 10 kA as directed by the Engr-in-Charge.
Supply and fix in repairs MCB 6 to 32 Amps, SP, 240 Volts , 'C' curve braking capacity 10 kA as directed by the Engr-in-Charge.
Supply and fix MCB 6 to 32 Amps, DP, 240 Volts , 'C' curve breaking capacity 10 KA as directed by the Engr-in-Charge.
Supply and fix in repairs MCB 6 to 32 Amps, DP, 240 Volts , 'C' curve breaking capacity 10 KA as directed by the Engr-in-Charge.
Supply and fix MCB, 63 Amps, FP, 240 Volts , 'C' curve breaking capacity 10 KA as directed by the Engr-in-Charge.
Materials and labour Sub main wiring with 2 runs of single core PVC insulated FR grade, unsheathed stranded copper conductor of size 4 Sqmm and one run of PVC insulated unsheathed multistrand copper conductor of size 4 Sqmm FR grade as earth lead drawn in and including PVC casing caping of suitable size including all fittings and taking out old unserviceable sub main wring including PVC casing caping complete all as specified and as directed. Note:- Two run 4 Sqmm main conductor and one run of 4Sqmm earthing conductor and one run of PVC casing caping shall be measured as one unit.
Materials and labour Sub main wiring with 2 runs of single core PVC insulated FR grade, unsheathed stranded copper conductor of size 6 Sqmm and one run of PVC insulated unsheathed multistrand copper conductor of size 6 Sqmm FR grade as earth lead drawn in and including non metallic PVC rigid conduit, 25mm dia, ISI marked including all fittings and taking out old unserviceable sub main wring including PVC casing caping complete all as specified and as directed. Note:- Two run 6 Sqmm main conductor and one run of 6Sqmm earthing conductor and one run of PVC Conduit shall be measured as one unit.
Materials and labour Sub main wiring with 2 runs of single core PVC insulated FR grade, unsheathed stranded copper conductor of size 10Sqmm and one run of PVC insulated unsheathed multistrand copper conductor of size 6 Sqmm FR grade as earth lead drawn in and including non metallic PVC rigid conduit, 32mm dia, ISI marked including all fittings and taking out old unserviceable sub main wring including PVC casing caping complete all as specified and as directed. Note:-Two run 10 Sqmm main conductor and one run of 10Sqmm earthing conductor and one run of PVC casing caping shall be measured as one unit.
Removing unserviceable ceiling fan upto 1400 mm sweep from its original position for inspection removing bush / bearing, cleaning of bush / bearing, replacement of unserviceable / worn out bearing / bush, and capacitor removing burnt out coils from the slots, cleaning etc reassembling and refixing of fan complete including 'S' hook for fixing of fan and including 1.5 Mtr length connecting rod and fixing back in position after servicing all as specified and as directed. Note:- (i) Spares will be measured and paid separately as "Supply only" under relevant items here-in-after
Material and Labour Rewinding of ceiling fan motor with super enamelled copper winding wire of suitable size and varnishing including testing of ceiling fan after rewinding complete all as specified and as directed.
Supply only Ball bearing suitable for ceiling fan upto 1400mm sweep / Wall mounted fan 400mm sweep.
Supply only Capacitor of 2.5 mfd for ceiling fan./ wall mounted fan.
Supply only Gun metal bush of suitable for ceiling fan / wall mounted fan.
Supply only nuts, bolts, for Ceiling fan
Supply only Shaft suitable for ceiling fan upto 1400mm sweep.
SSupply only PVC connector for Ceiling fan,
Supply only rubber reel insulator for Ceiling fan
Material and Labour Painting of ceiling fan of any size and sweep complete with synthetic enamel paint by spraying including filling with cavities with filler, after cleaning all dust etc including taking out of ceiling fan and refixing in same position complete all as specified and as directed by Engineer-in-Charge.
Removing unserviceable exhaust fan upto 300 mm sweep from position replacement of unserviceable bush and bearing, open the covers for repairs removing burnt out coils from the slots, cleaning and repairing of slots and fixing back in position after servicing all as specified and as directed. Note:- (i) Spares such as bearing and bushes etc will be paid separately as Supply only under relevent items here-in-after.
Material and Labour Painting of exhaust fan of any size and sweep complete with synthetic enamel paint by spraying including filling with cavities with filler, after cleaning all dust etc including taking out of ceiling fan and refixing in same position complete all as specified and as directed by Engineer-in-Charge.
Supply only Bush suitable for exhaust fan of suitable sweep.
Supply only Ball bearing suitable for exhaust fan of suitable sweep.
Supply only capacitor 3.15 mfd for exhaust fan of suitable sweep.
Taking down carefully storage type water heater (Geyser ) of any make of capacity 25 Ltrs after removing all electrical and water connection from installed position at different locations,dismantling the geyser into parts for inspection.Checking /testing of all parts/accessories like appratus plate,heating element,thermostat switch,neon lamp, water tank,safety valve, spacer ring, rubber gasket,nut-bolts,inspection plate, bottom& top cover etc. complete,de-scaling of water tank and brazing the same to make it leak proof complete inclduing replacement of unserviceable spare parts and re-installation, making electric and water connections and testing all as specified. Note :- Spare parts shall be measured & paid seperately as "Supply only" Items and make/model of spare parts shall be asper existing make/model oras specified and directed by Engr-in-Charge.
Supply only Heating element including rubber washer suitable for existing geyser of capacity 25 Ltrs.
Supply only PVC Connection of length not less than 30 Cm suitable for incoming and out going.
Supply only Apparatus plate (head assembly) complete all as per existing suitable for 25 Ltrs geysers of any make complete including rubber packing.
Supply only Thermostat switch suitable for geyser of capacity 25 Ltrs.
Supply only Inspection plate made out of 22 gauge MS sheet white painted (in two parts) suitable for geyser of capacity 25 Ltr.
Supply only Split plate (top cover ) made out of 22 gauge MS sheet,white painted suitable for geyser of capacity 25 Ltrs.
Supply only Safety valve (fusible plug) as per existing suitable for 25 Ltrs geyser.
Supply only Insulating materials (Glass wool) suitable for 25 Ltrs geyser.
Supply only PVC insulated copper conductor 6 Sqmm size, 3 core 1100 Volts grade.
Supply only 3 pin plug top suitable for metal clad enclouser 240 Volts complete suitable for existing one.
Supply only Neon Lamp round or square in shape as per existing.
Supply only Element holding clamp as per existing.
Supply only Storage tank fabricated from copper sheet gauge suitable for geyser of capacity 25 Ltrs of make as specified and approved.
Materials and labour Earthing complete with galvanised steel earth plate electrode 60 Cm x 60 Cm x 6.00 mm thick buried in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to GI wire 4 mm as earthing lead by means of bolts, nuts, check nuts and washers of GI or steel, GI strip projected by 40 mm bore light grade GI pipe and other end connected to earth test point as directed including funnel with watering pipe 20 mm bore light grade galvanised iron, wire mesh, charcoal or coke common salt laid in alternative layer of 15 cm (complete thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1, 50 mm thick pre-cast RCC (1:2:4) type B-1 normal mix cover slab reinforced with 8 mm dia TMT bar 10 Cm c/c both ways and single handle of 10 mm dia round bar including necessary excavation, earth work etc. in soft / loose soil and disposal pf soil to a distance n. exc. 50 m and necessary testing on completion all as shown in electrical plate No. 3 MES Schedule Part-I including taking out of old unserviceable earth pit with all accessories complete all as specified and as directed.
Supply and Fix in repairs MS louvers made of 22 guage MS sheet suitable for 300 mm sweep exhaust fan complete with grouting of bolts of suitable size in the wall upto any hight of the building including painting of louvers with two coats of synthetic enamle paint over a coat of red oxide complete all as directed by Engineer-in-Charge.
S C ROY AND CO
UNIVERSAL TRADING CENTRE
K.P Construction Co
SEN ELECTRIC WORKS
Tirupati Buildcon Pvt. Ltd.
MASTER BUILDERS
RADHA ENTERPRISE
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .