Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹7.5 LAccepted-AOC 334 SCHOOL DANGA BANKURA BANKURA WEST BENGAL 722101 | BANKURA | BANKURA | WEST BENGAL | 722101 | 1 | Accepted-AOC L1 | |
| 2 | 2₹7.5 L+₹653 (0.09%)Rejected-Finance VILL P O JAMBEDIA DIST BANKURA PIN 722139 | JAMBEDIA | BANKURA | WEST BENGAL | 722139 | 2 | Rejected-Finance L2 | |
| 3 | 3₹7.5 L+₹1,079 (0.14%)Rejected-Finance AT PRATAP BAGAN LANE NO 07 P O BANKURA DIST BANKURA PIN 722101 | BANKURA | BANKURA | WEST BENGAL | 722101 | 3 | Rejected-Finance L3 |
| Sl No | Description | Qty | Unit | Swarnendu Sarkar L1 | UJJWAL MUKHERJEE L2 | TITHI ELECTRONICS L3 |
|---|---|---|---|---|---|---|
| 1.00SITC of Lightning Arrester | ||||||
| 1.01 | Supply and installation by OEM or Authorized channel Partner of OEM, of external, wide area, early steamer emission OPR 30 type lightning arrester made of robust stainless steel & tested Standard stated in French Standard NF C17- 102, and IEC 62305-2. It is capable of polarizing the tip with a voltage of 600V to 10-20kV/m synchronized with an approaching lightning and triggering a powerful upward streamer with speed of 1m/µs into the air, with average time gain of 25 microseconds earlier than naturally formed streamers. Its upward streamers are strong enough to withstand applicable cyclonic wind speeds.The serial number displayed on the ESE lightning arrester shall be duly supported with the "certificate of country of origin" issued indicating the serial number of the product supplied. The ESE terminal must offer protection radius of 48 Mtrs. in Protection Level - I (high protection) and preferably to be mounted on the roof top of the building. ( Make: ABB) | 1 | Set | 1,99,693 ₹1,99,693 Lowest | 1,99,693 ₹1,99,693 Lowest | 1,99,693 ₹1,99,693 Lowest |
| 1.02 | Supply and installation by OEM or Authorized channel Partner of OEM of stainless steel support Mounting Mast 30 mm dia to hold early steamer emission OPR 30, of robust design with guy wire and base plate alongwith all accessories like clamps, shaddles, holding arrangements to fix mast to building structure at highest point such that the air terminal is 5 mtrs above the tallest structure Mounting Mast. (2 Mtrs. and 3 Mtrs. with Guy wire and Base Plate) | 1 | Set | 44,138 ₹44,138 Lowest | 44,139 ₹44,139 | 44,139 ₹44,139 |
| 1.03 | Supply and installation of lightning Stroke Counter by OEM or Authorized channel Partner of OEM working electro mechanically without any power supply.The recorder shall be of non-resettable type with the electro-mechanical display. No LCD screen is permittted as it may depend upon the battery life to energize the LCD. The lightning stroke recorder shall be duly tested & certified inline with the ESE lightning arrseter in an international labortaory for an impulse current (8/20 micro sec) and should count lightning strokes of 0.4 Ka to 150 Ka. ( Make ABB ) | 1 | Set | 72,348 ₹72,348 Lowest | 72,350 ₹72,350 | 72,350 ₹72,350 |
| 1.04 | Supply and Laying of Down Conductor G.I.Strip of 50/6 mm ( length - As per Actual), both Verticle and Horizontal, clamping by saddles not exceeding 500 mm apart with 35/8" screw for fixing in wall complete with full threaded bolts with nuts and double washers incl. mending good damages to building work. Finishing the ends of the above Strip by Nut and Bolts, etc. | 40 | Mtr | 435 ₹17,400 Lowest | 440 ₹17,600 | 440 ₹17,600 |
| 1.05 | Hiring charges for Scaffolding arrangement including dismantling at the end of work and carriage, for ESE OPR 30 LA installation. | 40 | Mtr | 148 ₹5,920 Lowest | 148 ₹5,920 Lowest | 148 ₹5,920 Lowest |
| 1.06 | Supply and Installation by OEM or Authorized channel Partner of OEM of Medium Pipe (10 ft. long, 2" dia G.I.Pipe along with earth rod and Chemical Gel filled with highly conducting metallic compounds with permenant sealings at both ends - ( Make Standard, ISI Brand )for Earthing and for inter connection of Earthing under ground (of 3 meters X 1nos. per pit) with 3 Earth pits of 10 feet deep each. | 3 | Nos | 19,962 ₹59,886 Lowest | 19,962 ₹59,886 Lowest | 19,962 ₹59,886 Lowest |
| 1.07 | Supply and Laying of maintenance free earthing terminal which consist of Ground Resistance Improving Furse Cem Conductive Aggregate material, tested as per BS. 1 bag of 25 kg. per Pit, to make it maintenance free and provide low resistance in the earth terminal to be executed by OEM or Authorized channel Partner of OEM only. | 3 | Nos | 22,499 ₹67,497 Lowest | 22,499 ₹67,497 Lowest | 22,499 ₹67,497 Lowest |
| 1.08 | RCC Civil work for foundation of Lightning arrestor mounting must suitable for holding 2000 Kg G.I./M.S structure of 0.5*0.5*1.1 meter along with Nut bolt and base plate. | 1 | job | 40,878 ₹40,878 Lowest | 40,878 ₹40,878 Lowest | 40,878 ₹40,878 Lowest |
| 1.09 | Lightning arrester mounting structure made with G.I./MS angle, pipe or strips for holding lightning arrester to 6 Mtr Ht. to withstand wind power about 120km/h. | 420 | kg | 142 ₹59,640 Lowest | 143 ₹60,060 | 144 ₹60,480 |
Tender Value
Refer Docs
EMD Value
₹23,000
Closing Date
3 Jan 2026, 11:30 amClosed
POcumDWO Bankura
Nutanchati Bankura
Supplying, installation , testing and commissoining of Lightning Arrestor, Water purifier and Cooler at Krishnapur Adibasi Ashram Hostel under Block-Saltora, Dist-Bankura. Project ID- TW252643691S000
2025_DMBAK_967838_1
e-NIQ-15/2025-26 (3592/BNK/BCW Dt 04-12-2025)
Open Tender
Electrical Work/ Equipment
Item Rate
60 days
Saltora
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹23,000
13 Jan 2026
5 Dec 2025
5 Jan 2026
5 Dec 2025
3 Jan 2026
5 Dec 2025
Amount
SITC of Lightning Arrester
Supply and installation by OEM or Authorized channel Partner of OEM, of external, wide area, early steamer emission OPR 30 type lightning arrester made of robust stainless steel & tested Standard stated in French Standard NF C17- 102, and IEC 62305-2. It is capable of polarizing the tip with a voltage of 600V to 10-20kV/m synchronized with an approaching lightning and triggering a powerful upward streamer with speed of 1m/µs into the air, with average time gain of 25 microseconds earlier than naturally formed streamers. Its upward streamers are strong enough to withstand applicable cyclonic wind speeds.The serial number displayed on the ESE lightning arrester shall be duly supported with the "certificate of country of origin" issued indicating the serial number of the product supplied. The ESE terminal must offer protection radius of 48 Mtrs. in Protection Level - I (high protection) and preferably to be mounted on the roof top of the building. ( Make: ABB)
Supply and installation by OEM or Authorized channel Partner of OEM of stainless steel support Mounting Mast 30 mm dia to hold early steamer emission OPR 30, of robust design with guy wire and base plate alongwith all accessories like clamps, shaddles, holding arrangements to fix mast to building structure at highest point such that the air terminal is 5 mtrs above the tallest structure Mounting Mast. (2 Mtrs. and 3 Mtrs. with Guy wire and Base Plate)
Supply and installation of lightning Stroke Counter by OEM or Authorized channel Partner of OEM working electro mechanically without any power supply.The recorder shall be of non-resettable type with the electro-mechanical display. No LCD screen is permittted as it may depend upon the battery life to energize the LCD. The lightning stroke recorder shall be duly tested & certified inline with the ESE lightning arrseter in an international labortaory for an impulse current (8/20 micro sec) and should count lightning strokes of 0.4 Ka to 150 Ka. ( Make ABB )
Supply and Laying of Down Conductor G.I.Strip of 50/6 mm ( length - As per Actual), both Verticle and Horizontal, clamping by saddles not exceeding 500 mm apart with 35/8" screw for fixing in wall complete with full threaded bolts with nuts and double washers incl. mending good damages to building work. Finishing the ends of the above Strip by Nut and Bolts, etc.
Hiring charges for Scaffolding arrangement including dismantling at the end of work and carriage, for ESE OPR 30 LA installation.
Supply and Installation by OEM or Authorized channel Partner of OEM of Medium Pipe (10 ft. long, 2" dia G.I.Pipe along with earth rod and Chemical Gel filled with highly conducting metallic compounds with permenant sealings at both ends - ( Make Standard, ISI Brand )for Earthing and for inter connection of Earthing under ground (of 3 meters X 1nos. per pit) with 3 Earth pits of 10 feet deep each.
Supply and Laying of maintenance free earthing terminal which consist of Ground Resistance Improving Furse Cem Conductive Aggregate material, tested as per BS. 1 bag of 25 kg. per Pit, to make it maintenance free and provide low resistance in the earth terminal to be executed by OEM or Authorized channel Partner of OEM only.
RCC Civil work for foundation of Lightning arrestor mounting must suitable for holding 2000 Kg G.I./M.S structure of 0.5*0.5*1.1 meter along with Nut bolt and base plate.
Lightning arrester mounting structure made with G.I./MS angle, pipe or strips for holding lightning arrester to 6 Mtr Ht. to withstand wind power about 120km/h.
SITC of Water purifier and cooler
SITC of Automatic RO water purifier Machine with Uv protection and TDS controller on wall has a high purification capacity of 80-100 L/hr , Max duty cycle per day 500 LPD with filter change alarm for enhanced safety, Durable Stainless steel body. Dimension[ 505(L)*360 (W)*746(H)] code 11079 (Make: Kent/Bluestar/LG)
SITC of Automatic Water cooling machine of double tap (One for normal water other for cold water) of 40 liter capacity. Make: Blue Star
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand: Polycab/Finolex/KEI) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. nency fittings as required, i) 2x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC
Supply & Fixing 240 V, 16A, 3 pin Modular type plug socket, 16A Modular type switch, without plug top, 16A switch type SP MCB on 4 Module GI Modular type switch board with 4 Module top cover plate (Brand approved by EIC) flushed in wall incl. S & F switch board and top cover plate and making necessary connections as required
Finishing of the PVC insulated wire ends by socketing with pin/ring type copper sockets and insulated tapes etc. including supplying sockets, tapes. 2.5 sqmm
Shed and protection cell by fabricated G.I. angle strips with net covering and shed over the top with sheet
UJJWAL MUKHERJEE (BID ID -7685595)
TITHI ELECTRONICS (BID ID -7686556)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .