Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.6 LAccepted-AOC III 6 7 2ND FLOOR ABOVE BANK OF BARODA GOPINATH BAZAR DELHI CANTT 110 010 | DELHI CANTT | NEW DELHI | DELHI | 110010 | L1 | Accepted-AOC being L1 | |
| 2 | L2₹23.8 L+₹19,570 (0.83%)Rejected-Finance 1 128 A SECOND FLOOR MOHAMMADPUR NEAR BHIKAJCAMA PLACE NEW DELHI 110066 | NEW DELHI | NEW DELHI | DELHI | 110066 | L2 | Rejected-Finance OTHER THAN L1 | |
| 3 | L3₹26.0 L+₹2.4 L (10.2%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN L1 | |
| 4 | L4₹26.7 L+₹3.1 L (13.3%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN L1 |
| Sl No | Description | Qty | Unit | MB Enterprises L1 | M/s Dhapola Elevator and Engineering L2 | V S BUILDER L4 | M/S BALAJI ENTERPRISES L3 |
|---|---|---|---|---|---|---|---|
| 1.00 | Design, Supply, installation, erection, testing and commissioning by OEM of passenger lift electrically operated of capacity 8 passenger (544 Kg) Gearless machine (Machine Room Less) and including fixing arrangement with Microprocessor controller (VVVF) based, selective collective control, speed 1.5 mtr per second serving ground floor and five upper floor (G+5), total six landings, infra red screen door sensor, over load warning indicator, intercom system with single automatic push button operation with/without attendant, having suitable car/case size, doors (Car & Landing) in SS hair line finish, stainless steel hand rail on rear wall of car cabin, floor annunciator with music/arrival chime, Car Operating Panel, emergency battery backup for light, Car Cabin made out of minimum 18 SWG Stainless Steel hair line finish as well as car cabin roof covered with 18 SWG stainless steel (hair line finish), cabin floor made of black polish granite stone and as per IS 14665 specifications complete all as specifed and directed. | 1 | Each Job | 18,95,000 ₹18,95,000 Lowest | 21,20,000 ₹21,20,000 | 23,50,000 ₹23,50,000 | 19,50,000 ₹19,50,000 |
| 1.01(a) Electrically operated with electric motor AC 415 Volts, 3 Phase 50 HZ of suitable capacity as per IS (efficiency class equivalent to IE 2) and operating gearless box with independent main sheave rim. | |||||||
| 1.02(b) Electric cabling and wiring in FRLS copper cable including all necessary PVC conduits ISI marked of suitable size | |||||||
| 1.03(c) Micro processor based VVVF type main controller with closed loop system. | |||||||
| 1.04(d) Car position indicator in car all fixture in SS face plate (both insided/out-side). All buttons should be with brail marking and luminous. | |||||||
| 1.05(e) Provn of travelling cable with copper conductor FRLS of suitable size & core or required wiring to intercom speaking & other accessories. | |||||||
| 1.06(f) Inbuilt ARD (Automatic Rescue Device) with maintenance free batteries operated to bring the car cage to the nearest floor level in case of power failure, which includes power failure of one or more phase. Emergency light and at least one fan inside the lift car shall be operational till the rescue operation and an audio and visual indicator shall be provided inside car to alert the persons trapped inside that they are being rescued. | |||||||
| 1.07(g) Provision of governor and governor rope of suitable size, buffer springs as per manufacture's design, car cabin having powered doors and inspection box at top of the car cabin, compact high efficiency drive combined with suspension Traction Media Technology. Grooved Belt and alongwith belt monitoring device which can ensure to prevent from any breakage of belt and taking elevator nearest landing. | |||||||
| 1.08(h) Provision of safety guarding equipments such as 02 Nos pit switches controller, guarding pit, pulley, guarding pit ladders, facia plate to cover free space between car cabin and hoist way & switches. | |||||||
| 1.09(j) Door sensor not less than 74 beam, 2D infra red full length | |||||||
Tender Value
₹27.0 L
EMD Value
₹54,080
Closing Date
25 Jun 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE NEW DELHI
HQ CWE NEW DELHI
SPL REPAIR REPLACEMENT OF 01 X BER LIFT AT BLDG NO P94 AT AHRR UNDER GE EM RR HOSP
2025_MES_711556_1
CWE-ND/14/2025-26
Open Tender
Civil Works - Others
Item Rate
120 days
DELHI
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE E/M RR HOSP
₹54,080
2 Sept 2025
30 May 2025
27 Jun 2025
30 May 2025
25 Jun 2025
13 Jun 2025
Amount
(a) Electrically operated with electric motor AC 415 Volts, 3 Phase 50 HZ of suitable capacity as per IS (efficiency class equivalent to IE 2) and operating gearless box with independent main sheave rim.
(b) Electric cabling and wiring in FRLS copper cable including all necessary PVC conduits ISI marked of suitable size
(c) Micro processor based VVVF type main controller with closed loop system.
(d) Car position indicator in car all fixture in SS face plate (both insided/out-side). All buttons should be with brail marking and luminous.
(e) Provn of travelling cable with copper conductor FRLS of suitable size & core or required wiring to intercom speaking & other accessories.
(f) Inbuilt ARD (Automatic Rescue Device) with maintenance free batteries operated to bring the car cage to the nearest floor level in case of power failure, which includes power failure of one or more phase. Emergency light and at least one fan inside the lift car shall be operational till the rescue operation and an audio and visual indicator shall be provided inside car to alert the persons trapped inside that they are being rescued.
(g) Provision of governor and governor rope of suitable size, buffer springs as per manufacture's design, car cabin having powered doors and inspection box at top of the car cabin, compact high efficiency drive combined with suspension Traction Media Technology. Grooved Belt and alongwith belt monitoring device which can ensure to prevent from any breakage of belt and taking elevator nearest landing.
(h) Provision of safety guarding equipments such as 02 Nos pit switches controller, guarding pit, pulley, guarding pit ladders, facia plate to cover free space between car cabin and hoist way & switches.
(j) Door sensor not less than 74 beam, 2D infra red full length
(k) Provision of fire man switch complete at ground floor fitted in box including SS face plate.
(l) Provision of "Press and Speak" system to be connected with lift complaint cell compatible with exchange. Provision of Automatic call registration in case of breakdown.
(m) Do's & Don’ts chart on stainless steel sheet min 5 mm thich of size not less than 18 x 12 ich to be installed inside the car cabin.
(n) A three Pin plug socket with switch for hand lamp shall be fitted on top of the lift car for use by person working there on.
(o) Provn of 40 mm SS handrail on three side of the lift.
(p) Provn of transparent space for highlights the imp instructions and Mobile Nos.
(q) Provn of RCCB/RCBO in SS enclosure.
M&L Earthig complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick, burried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanised iron strip 32x6mm as earthing lead by means of bolts, nuts, checks nuts and washers of galvanised iron of steel all as shown in electrical plate No 3 connect to earthing test point all as specified or indicatd including testing on completion.
M&L for Earth continuity conductor or main earthing lead fix to wall on batten or recess or chases or burried in ground or drawn in conduit /pipe or fix to pole or any other indicated situation for loop earthing extra as required but size 32 x 6 mm galvanised iron strip.
S&F Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw
S&F insulator for earth strip complete all as specified and as directed
S&F VTPN DB 4 way with MCCB incomer complete all as specified and as directed
M&L for taking down existing lift G+5 and deposit in MES store yard complete all as specified and as directed
S&F XLPE cable 16 sqmm 4 core armoured, heavy duty electric cable with aluminium conductor, 1100 volt grade fixing on wall with clips complete all as specified and as directed
S&F I-section beam 200x100 mm complete all as specified and directed.
Supply & fix shaft light of lift environmental friendly, ultra modren, energy saving LED fitting 20W with all connection incl wiring all as per site requirement complete all as specified and directed.
S&F Sub-main Wiring with 2-Runs of 1.5 Sqmm (nominal area) 1100 Volt, PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable and 1-Run of 1.5 Sqmm (nominal area) 1100 Volt, PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuty Cable along with the Wiring drawn in including PVC CONDUIT complete all as specified and as directed.
S&F PVC rectangular block for mounting switches,sockets,fan regulator etc with 3 mm thick plastic laminated sheet cover of size 200 x 150 x 50 mm including cutting for mounting of switches and sockets, complete all as specified and as directed by Engineer-in-charge.
S&F modular Socket Outlet 6 &16 Amp 2/3 pin combined 2 module, complete all as specified and as directed.
S&F Switch Piano 6 Amp, Flush type, Single Pole, 1-way and , complete all as specified and as directed. MAKE ANCHOR/KINJAL/SSK
Taking down cement plaster of any description on brick or stone walls etc including racking out joints hacking for key scrubbing down with water etc complete all as specified and as directed by the Engineer-in-Charge.
Demolition of un-reinforced Concrete of any description and in any position not otherwise specifically provided for complete all as specified
M&L rendering 15mm thick in CM 1:4 on external fair faces of brick work or concrete surface to fair and even without using extra cement complete all as specified and as directed
Providing and laying cement concrete floor (Indian Patent Stone) 40 mm to 65 mm thick to maintain required slope, P.C.C.(1:2:4) mix using 12.5 mm graded stone aggregate, adding fiber mesh @125 gms/cement bag and sunplex @ 330 gms /cement bag laid in alternate bays troweled smooth on top in neat cement and making lines on the top surface diagonally or square at spacing, curing for minimum 7 days, as directed etc. complete.
Demolition of brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles
M&L brick work with sub class ‘B’ bricks straight or curved on plan exc 6 m mean radius built in CM 1:6 with old size bricks
(a) M&L clean the surface, remove dust dirt, loose particles and unsound substrate and providing 20 mm thick cement screed (1:4) mixed with Dr Fixit or equivalent tonic liquid 200 gram/Bag over Dr Fixit or equivalent as approved by GE. (b) Applying primer coat with solvent based Bitumen primer @ 0.5 ltr/sqm. (c ) Dr Fixit or equivalent as approved by GE torch shield water proofing 3mm thick membrane use gas burner to heat substrate, press firmly from lower end to upper and with 100 mm overlap. (d) Heat both over lap with round tipped trowel to seal over lap . Excess compound smoothened, pressed into seam using hot trowel. (e) Seal edges well into grooves & protect with a poly sulphide sealant. (f) M&L hydraulically pressed burnt clay tiles plain size 300X300X19 mm laid over and including 15mm thick screed in CM 1:4 with WPC & pointed in CM 1:3 mixed with crude oil. (Note 1 :- WPC as per manufacturer's instruction shall be deemed to be included in unit rate quoted.) (Note 2 : Water proofing treatment shall be carried out through approved manufacturer's applicator). (g) Uploading of material shall be carried out by mechanical means, use of staircase is strically probihited
M&L for preparation of newly plastered surface of wall and applying two coat of weather proof exterior emulsion extra premium 100% acrylic emulsion as approved over a coat of primer complete all as specified and directed.
Providing & applying two coats of Acrylic Elastomeric Exterior waterproofing compound of “Dr. Fixit Raincoat” or equivalent approved make including putty and one coat of approved priming coat as per the waterproofing coating manufacturer to vertical wall/floor surfaces at any level and location including scaffolding etc. complete, as per instruction of the Engineer in Charge.
M&L for cleaning the surface of lift pit with wire brush complete all as specified and directed
Providing and laying injection grouting treatment by drilling GI threaded nozzles to 1/3rd the depth of the concrete of 15 mm dia at 0.75 mtr, c/c tied to reinforcement while chocking both ends of nozzles. After the concrete pour, pressure grouting the nozzles with hand machne of requisite pressure so that the cement slurry is injected into the capilaries and thereby creating dense concrete. Suitable grouting admixture like Dr Fixit PIDICRETE AM or equivalent in SIKKA/FOSROC/CHOCKSEY to be admixed with cement slurry so as to make the mix more flowable, non-shrink expanding and watertight. Flushing/ removing the nozzles from the structure and plugging the holes with Dr Fixit Epoxy Mortar or equivalent in Sikka/Pidilite complete all as specified and as directed. Note: Work has to be carried out by water proofing OEM
M&L for taking down kota stone/marbel complete all as specified and as directed.
M&L Machine Cut Kota stone 18-20 mm thick on floor/walls over cement screen base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab includding rubbing and polishing complete all as specified and as directed.
M&L for screen bed of mortar 10 mm thick in cm of 1:4, complete all as specified and as directed
M&L for fixing lift facia SS hairline finish with fire proof board 10 mm thick to be fixed on wall around lift door complete all as specified and as directed
S&F lift car cabin mirror 5 mm thick using nut/ bolts/studs complete all as specified and as directed
S&F acrylic transparent paper holder using studs complete all as specified and as directed.
M/s Dhapola Elevator and Engineering (BID ID -3327661)
M/S BALAJI ENTERPRISES (BID ID -3327841)
V S BUILDER (BID ID -3335743)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .