| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.9 LAccepted-AOC TAILOR MARKET MAIN BAZAAR MANDI ADAMPUR 125052 | HISAR | HARYANA | 125052 | ₹2.9 L | L1 | Accepted-AOC L1 |
| Sl No | Description | Qty | Unit | Prime Computers L1 |
|---|---|---|---|---|
| 1.01 | [23.7.6.2]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia. [Through Rate] | 90 | meter | 31 ₹2,790 |
| 1.02 | Supply and erection of Fire Extinguishers duly hang on wall with necessary hook complete in all respect. Make Make: Safex / Minimax / Cease Fire). ABC Dry Powder extinguisher 6 Kg Capacity. | 2 | Each | 4,850 ₹9,700 |
| 1.03 | Supply and erection of Fire Extinguishers duly hang on wall with necessary hook complete in all respect. Make Make: Safex / Minimax / Cease Fire). CO2 type 4.5 Kg Capacity. | 2 | Each | 7,450 ₹14,900 |
| 1.04 | SITC of Micro processor based 2 wire fault tolerant, networkable type Fire Alarm / Detection Control Panel (having nos. of 2 loops to suit minimum 20% extra over the nos. of fire detectors. The panel shall be able to give location of all fire / fault conditions of addressable units via the address codes. Further, the panel must be able to automatically switch ON/OFF respective control module when ever any alarm is triggered. The panel shall have rectifier, loop cards, minimum 160 characters LCD unit/ 5.7’’TFT to indicate Fire / Fault Signal with address and analog output, external/inbuilt printer to log all fire or fault events complete in all respects. The Panel Shall be sheet Steel power coated, sealed to IP30. The Panel shall have 20 Zones with individual LED Indicators, expandable to 80 LED Indicators. The Panel shall have 3 Serial Ports. The pane\ shall have a built in power supply and battery charger maintenance free 24 AH 2x12 W SMF LED battery capable of running for a minimum 24 hours with battery charger complete as required. And conforming to BS5839 standards and Duly Approved by EN 54/UL/VDS/ as per specification complete in all respect upto entire satisfaction of engineer incharge of work .Make:Honeywell Marlay DXE series /Bosch FPA 1000 series/ Cerberus by Siemens | 1 | Each | 1,68,500 ₹1.7 L |
| 1.05 | SITC of Glow Type Exit Sign Board photo luminescent of size 300 mm x 250 mm x 1.5 mm rigid sheet signage containing Zink Sulphate as bare chemical class - I material PSPA fixed on 3 mm acrylic sheet on both side showing marking (running man, Arrow and Exit) and hanged with the ceiling with chain and fastener including cost of labour and material required to complete the job in all respect up to entire satisfaction of Engineer-in-Charge of work.Make Pearl/Giolite/OMEX. | 2 | Each | 2,050 ₹4,100 |
| 1.06 | SITC of PVC unsheathed s/c stranded ( ISI marked ) copper conductor cable 1100v grade in existing pipe excluding cost and erection of pipe but including connection etc. with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer – in charge of work PVC unsheathed copper size 1.5 sq mm single core MAKE FINOLEX/POLYCAB/Plaza.. | 375 | Metre | 25 ₹9,375 |
| 1.07 | Supply Installation Testing and Commissioning of addressable multisensor detector with a combination of Optical and Thermal including mounting base, auto addressing feauture as required. Detetctor should have 2 as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements. High resistance to electromagnetic effects in accordance with EFSG agreement EFSG/F/97/005 .Detector should monitor Electromagnetic interference and report to the panel - current and average values. EMC safety for detector shall be 50 V/m. Shall be EN54/ VDs/UL certification. (Detectors without Inbuilt Isolators may be considered with an additional Isolator Module after 20 devices) Make: Honeywell Morley / Siemens Cerberus / Edwards | 18 | Each | 3,050 ₹54,900 |
| 1.08 | SITC of Analog Addressable type Manual Call Point having Surface or flush mounting option fully compliat to EN 54 having Rotary Decade switches for addressing with back box for mounting as required conforming to BS5839 standards and duly approved by EN54/UL/VDS required to complete the job in all respect up to the entire satisfaction of Engineer – in Charge of work. Make : Morley HM/MCP/Glass, Bosch FMC-210- DM-G-R, Siemens FDM22.(Rates are excluding GST). | 2 | Each | 3,810 ₹7,620 |
| 1.09 | SITC of Addressable Loop powered sounder with strobe/flasher complete with mounting base as required conforming to BS5839 standards and duly approved by EN54/UL/VDS required to complete the job in all respect up to the entire satisfaction of Engineer - in Charge of work. Make: Morley WSO-PR-N05,Bosch FNM-420, Siemens FDS224R (Rates are excluding GST). | 2 | Each | 6,500 ₹13,000 |
| 1.10 | SITC of minimum 1000 Mtr. Range Siren genertor provided at the roof of building with separate power supply, relay etc with all accessories required to complete the job in all respect up to the entire satisfaction of Engineer – in Charge of work. Make:- Kheraj / National. | 1 | Each | 9,400 ₹9,400 |
Tender Value
₹3.0 L
EMD Value
₹6,015
Closing Date
15 Dec 2025, 5:00 pmClosed
RAVI Ladwal
ED - Rewari
Rough cost estimate of providing Fire Alarm system for newly constructed record room in judicial complex at Narnaul.
2025_HRY_488551_1
2025DFCB835A FCEB 4615 8A2B D923471F4BE7668BAR
Open Tender
Civil Works
30 days
Narnaul
2 documents required · 2 mandatory
₹500
₹6,015
Yes
6 Jan 2026
8 Dec 2025
16 Dec 2025
8 Dec 2025
15 Dec 2025
8 Dec 2025
Amount
[23.7.6.2]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia. [Through Rate]
Supply and erection of Fire Extinguishers duly hang on wall with necessary hook complete in all respect. Make Make: Safex / Minimax / Cease Fire). ABC Dry Powder extinguisher 6 Kg Capacity.
Supply and erection of Fire Extinguishers duly hang on wall with necessary hook complete in all respect. Make Make: Safex / Minimax / Cease Fire). CO2 type 4.5 Kg Capacity.
SITC of Micro processor based 2 wire fault tolerant, networkable type Fire Alarm / Detection Control Panel (having nos. of 2 loops to suit minimum 20% extra over the nos. of fire detectors. The panel shall be able to give location of all fire / fault conditions of addressable units via the address codes. Further, the panel must be able to automatically switch ON/OFF respective control module when ever any alarm is triggered. The panel shall have rectifier, loop cards, minimum 160 characters LCD unit/ 5.7’’TFT to indicate Fire / Fault Signal with address and analog output, external/inbuilt printer to log all fire or fault events complete in all respects. The Panel Shall be sheet Steel power coated, sealed to IP30. The Panel shall have 20 Zones with individual LED Indicators, expandable to 80 LED Indicators. The Panel shall have 3 Serial Ports. The pane\ shall have a built in power supply and battery charger maintenance free 24 AH 2x12 W SMF LED battery capable of running for a minimum 24 hours with battery charger complete as required. And conforming to BS5839 standards and Duly Approved by EN 54/UL/VDS/ as per specification complete in all respect upto entire satisfaction of engineer incharge of work .Make:Honeywell Marlay DXE series /Bosch FPA 1000 series/ Cerberus by Siemens
SITC of Glow Type Exit Sign Board photo luminescent of size 300 mm x 250 mm x 1.5 mm rigid sheet signage containing Zink Sulphate as bare chemical class - I material PSPA fixed on 3 mm acrylic sheet on both side showing marking (running man, Arrow and Exit) and hanged with the ceiling with chain and fastener including cost of labour and material required to complete the job in all respect up to entire satisfaction of Engineer-in-Charge of work.Make Pearl/Giolite/OMEX.
SITC of PVC unsheathed s/c stranded ( ISI marked ) copper conductor cable 1100v grade in existing pipe excluding cost and erection of pipe but including connection etc. with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer – in charge of work PVC unsheathed copper size 1.5 sq mm single core MAKE FINOLEX/POLYCAB/Plaza..
Supply Installation Testing and Commissioning of addressable multisensor detector with a combination of Optical and Thermal including mounting base, auto addressing feauture as required. Detetctor should have 2 as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements. High resistance to electromagnetic effects in accordance with EFSG agreement EFSG/F/97/005 .Detector should monitor Electromagnetic interference and report to the panel - current and average values. EMC safety for detector shall be 50 V/m. Shall be EN54/ VDs/UL certification. (Detectors without Inbuilt Isolators may be considered with an additional Isolator Module after 20 devices) Make: Honeywell Morley / Siemens Cerberus / Edwards
SITC of Analog Addressable type Manual Call Point having Surface or flush mounting option fully compliat to EN 54 having Rotary Decade switches for addressing with back box for mounting as required conforming to BS5839 standards and duly approved by EN54/UL/VDS required to complete the job in all respect up to the entire satisfaction of Engineer – in Charge of work. Make : Morley HM/MCP/Glass, Bosch FMC-210- DM-G-R, Siemens FDM22.(Rates are excluding GST).
SITC of Addressable Loop powered sounder with strobe/flasher complete with mounting base as required conforming to BS5839 standards and duly approved by EN54/UL/VDS required to complete the job in all respect up to the entire satisfaction of Engineer - in Charge of work. Make: Morley WSO-PR-N05,Bosch FNM-420, Siemens FDS224R (Rates are excluding GST).
SITC of minimum 1000 Mtr. Range Siren genertor provided at the roof of building with separate power supply, relay etc with all accessories required to complete the job in all respect up to the entire satisfaction of Engineer – in Charge of work. Make:- Kheraj / National.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.00 MB
BOQ_566721.xls
BOQ • 0.24 MB
Download all tender documents and submit your bid