| 1 | L1₹22.7 LAccepted-AOC | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹26.9 L+₹1.8 L (7.04%)Rejected-Finance 202 NEW RAM VIHAR COLONY PINTO PARK MORAR GWALIOR 474005 | GWALIOR | GWALIOR | MP | 474005 | L2 | Rejected-Finance OTHER THAN L1 | |
| 3 | L3₹29.3 L+₹4.1 L (16.4%)Rejected-Finance 15 CP COLONY MORAR GWALIOR MP 474 006 | GWALIOR | GWALIOR | MADHYA PRADESH | 474006 | L3 | Rejected-Finance OTHER THAN L1 | |
| 4 | L4₹29.6 L+₹4.5 L (17.8%)Rejected-Finance 15 15 KHERIYA BHAN PURANI CHAWANI GWALIOR GWALIOR GWALIOR MADHYA PRADESH 474010 | GWALIOR | MADHYA PRADESH | 474010 | L4 | Rejected-Finance OTHER THAN L1 | |
| 5 | L5₹30.9 L+₹5.8 L (23.1%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN L1 |
| Sl No | Description | Qty | Unit | m/s anil traders L6 | M/S STEAD FAST L1 | BABA DEVELOPERS L5 | M/s Anupam Construction Co. L3 | M/S AUTOMATION AND SWITCHGEAR CONTROL L2 | AUTOMATION AND SWITCHGEAR PANELS L4 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Dismantling of air circuit breaker of capacity of 800 Amps to 1250 Amps of any pole/make/model from the panel, checking, servicing, cleaning of breaker with CRC-226, removal of old grease and re-greasing with recommended grease, checking the condition of moving and fixed contacts, checking the tripping mechanism, tripping of ACB manually through voltmetric release, adjust freeness of DN and volt metric release trip rod, checking the proper tightening of hardware, checking the presence of all circlips, alignment of jaw contact with cradle terminals, checking the condition of ACB wiring, adjusting the gap between hylem sheet and side plate, checking the condition of arc chutes, under voltage relay, shunt release, auxiliary contact, checking the release by secondary injection for O/L, S/C, E/F, setting of release as per the load, Checking the healthiness of the CTs, complete all as specified and directed.
Note:- Spares shall be measured and paid separately under the appropriate item in the schedule as supply only. | 10 | Job | 500 ₹5,000 Lowest | 3,400 ₹34,000 | 4,000 ₹40,000 | 5,000 ₹50,000 | 3,000 ₹30,000 | 4,000 ₹40,000 |
| 2.00 | All as per the above item but ACB of 1250 Amp to 2000 Amp complete all as specified and as directed. | 4 | Job | 500 ₹2,000 Lowest | 4,000 ₹16,000 | 3,000 ₹12,000 | 6,000 ₹24,000 | 4,000 ₹16,000 | 5,000 ₹20,000 |
| 3.00 | Supply only burnt-out closing tripping shunt, or UV coil of ACB, of existing make as per site through an authorized representative, including interlock wiring with suitable copper wire, complete all as specified and directed. | 2 | Each | 3,000 ₹6,000 | 1,000 ₹2,000 Lowest | 2,500 ₹5,000 | 1,000 ₹2,000 Lowest | 2,000 ₹4,000 | 2,500 ₹5,000 |
| 4.00 | Supply only charging motors 220 V AC suitable for ACB 800 Amp to 2000 Amp of existing make as per Site complete with all accessories | 2 | Each | 2,000 ₹4,000 | 1,500 ₹3,000 | 2,500 ₹5,000 | 700 ₹1,400 Lowest | 3,000 ₹6,000 | 3,500 ₹7,000 |
| 5.00 | Supply only Main Fixed contacts (Upper terminals) suitable for ACB 800 A to 2000 Amp of existing make as per Site complete with all accessories. | 2 | Each | 1,500 ₹3,000 | 700 ₹1,400 Lowest | 2,500 ₹5,000 | 700 ₹1,400 Lowest | 2,500 ₹5,000 | 1,500 ₹3,000 |
| 6.00 | Supply only Main isolating contacts (Jaw contacts) suitable for ACB 800 A to 2000 Amp, of existing make as per Site complete with all accessories. | 2 | Each | 1,000 ₹2,000 | 1,000 ₹2,000 | 2,400 ₹4,800 | 700 ₹1,400 Lowest | 3,500 ₹7,000 | 2,500 ₹5,000 |
| 7.00 | Supply only Arcing contact assembly (set of 01 No fixed & 01 No moving) suitable for ACB 800 to 2000 Amp, of existing make as per Site, complete with all accessories. | 2 | Each | 2,500 ₹5,000 | 650 ₹1,300 Lowest | 3,100 ₹6,200 | 1,000 ₹2,000 | 4,000 ₹8,000 | 2,000 ₹4,000 |
| 8.00 | Supply only manual charging handle for ACB 800 A to 2000 Amp of existing make as per Site complete with all accessories. | 4 | Each | 4,000 ₹16,000 | 800 ₹3,200 | 1,250 ₹5,000 | 500 ₹2,000 Lowest | 800 ₹3,200 | 1,800 ₹7,200 |
| 9.00 | Supply only Spring charged indication switch for ACB 1000 Amp to 2000 Amp of existing make as per Site complete all as specified and as directed | 5 | Each | 1,000 ₹5,000 | 700 ₹3,500 | 1,400 ₹7,000 | 70 ₹350 Lowest | 200 ₹1,000 | 2,500 ₹12,500 |
| 10.00 | M & L for removing of flashed carbon from Air Circuit Breaker, MCCB, Contactors, Bus Bar chamber etc of LT Panel, AMF Panel, Junction box by cleaning with cleaning agent properly and replacement of burnt out parts like spreader link, suitable size lugs, replacement of bus bar insulator, replacement of damaged handle of switchgears and applying heavy duty HVBT tape on bus bar with colour coding on each phase complete all as specified and directed by Engr-in-Charge.
Notes :- Cost of Lugs will be measured and paid seperately. | 200 | Job | 100 ₹20,000 Lowest | 200 ₹40,000 | 100 ₹20,000 Lowest | 200 ₹40,000 | 100 ₹20,000 Lowest | 100 ₹20,000 Lowest |
Tender Value
₹44.9 L
EMD Value
₹89,876
Closing Date
3 Sept 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) TA GWALIOR
GE (AF) TA GWALIOR-474020
REPAIR MAINTENANCE OF OF SWITCH GEARS AT PS-1 AND PS-2 AND VITAL AIRFIELD INSTALLATIONS AIR FIELD LIGHTING SYSTEM INCLUDING CERTAIN CONNECTED WORKS INSIDE TECHNICAL AREA OF AFS GWALIOR
2025_MES_723871_1
8900/1606/GWL/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Gwalior
Please ref tender documents
7 documents required · 7 mandatory
₹500
GE (AF) TA GWALIOR
₹89,876
Yes
17 Oct 2025
1 Aug 2025
10 Sept 2025
1 Aug 2025
3 Sept 2025
15 Aug 2025
Amount
Dismantling of air circuit breaker of capacity of 800 Amps to 1250 Amps of any pole/make/model from the panel, checking, servicing, cleaning of breaker with CRC-226, removal of old grease and re-greasing with recommended grease, checking the condition of moving and fixed contacts, checking the tripping mechanism, tripping of ACB manually through voltmetric release, adjust freeness of DN and volt metric release trip rod, checking the proper tightening of hardware, checking the presence of all circlips, alignment of jaw contact with cradle terminals, checking the condition of ACB wiring, adjusting the gap between hylem sheet and side plate, checking the condition of arc chutes, under voltage relay, shunt release, auxiliary contact, checking the release by secondary injection for O/L, S/C, E/F, setting of release as per the load, Checking the healthiness of the CTs, complete all as specified and directed. Note:- Spares shall be measured and paid separately under the appropriate item in the schedule as supply only.
All as per the above item but ACB of 1250 Amp to 2000 Amp complete all as specified and as directed.
Supply only burnt-out closing tripping shunt, or UV coil of ACB, of existing make as per site through an authorized representative, including interlock wiring with suitable copper wire, complete all as specified and directed.
Supply only charging motors 220 V AC suitable for ACB 800 Amp to 2000 Amp of existing make as per Site complete with all accessories
Supply only Main Fixed contacts (Upper terminals) suitable for ACB 800 A to 2000 Amp of existing make as per Site complete with all accessories.
Supply only Main isolating contacts (Jaw contacts) suitable for ACB 800 A to 2000 Amp, of existing make as per Site complete with all accessories.
Supply only Arcing contact assembly (set of 01 No fixed & 01 No moving) suitable for ACB 800 to 2000 Amp, of existing make as per Site, complete with all accessories.
Supply only manual charging handle for ACB 800 A to 2000 Amp of existing make as per Site complete with all accessories.
Supply only Spring charged indication switch for ACB 1000 Amp to 2000 Amp of existing make as per Site complete all as specified and as directed
M & L for removing of flashed carbon from Air Circuit Breaker, MCCB, Contactors, Bus Bar chamber etc of LT Panel, AMF Panel, Junction box by cleaning with cleaning agent properly and replacement of burnt out parts like spreader link, suitable size lugs, replacement of bus bar insulator, replacement of damaged handle of switchgears and applying heavy duty HVBT tape on bus bar with colour coding on each phase complete all as specified and directed by Engr-in-Charge. Notes :- Cost of Lugs will be measured and paid seperately.
Supplying and laying synthetic rubber insulated mats 2.5 mm thick of size 2m x 1m complete all as specified and directed.
Annual maintenance servicing and testing of APFC panel of capacity 600 KVAr, including checking of Phase cap capacitors in all capacitor banks, all MCCB's, duty contactors, st relay and all connected wiring, including refitting complete all as specified & directed. Note :- (a) Spares required for replacement shall be measured and paid separately.
All as per the above item but APFC panel of capacity 150 KVAr complete all as specified and as directed.
All as per the above item but APFC panel of capacity 125 KVAr, complete all as specified and as directed.
All as per the above item but APFC panel of capacity 75 KVAr complete all as specified and as directed.
All as per the above item but APFC panel of capacity 50 KVAr complete all as specified and as directed.
Supply only phase cap capacitor of capacity 5 KVAr in APFC panel completed all as specfied & directed.
Supply only phase cap capacitor of capacity 10 KVAr in APFC panel completed all as specified & directed.
Supply only power factor controller ST relay,230 Volt suitable for 600 KVAr APFC panel in APFC panel completed all as specfied & directed.
Supply only power factor controller ST relay ,230 Volt suitable for 150 KVAr APFC panel in APFC panel completed all as specfied & directed.
Supply only for duty contactor suitable for 5 KVAr capacitor and match with the existing complete all as specfied & directed.
Supply only for duty contactor suitable for 10 KVAr capacitor and match with the existing complete all as specfied & directed.
Supply and fix in replacement of first aid kit box / Emergency medical box wall mouted type made out of powder coated GI sheet of 18 gauge and the size of the box will be 36cm(H) x 26cm(W) x 13 cm(D) with front transparent acrylic glass and multi compartment 4 shelf for better organize of medicines with security lock on door openable window at front side with help of hinge at one side and locking arrangement at another side, openable window must painted with "FIRST AID" with red paint and whole box will fixed on wall at height not less than 2mtr including medicene and other items are as under :- Sterilized dressings(04), Cotton Wool 10 gm (02), Antiseptic Solution 100 ml (01), Burn Ointment (01), Scissor (01), Digital Thermometer (01), Disposal Gloves(02), Disposal Mask (20), Adhesive / Microporous Tape 1/2" (01), Band- Aid (10), safety pins(05), Sofraxime Cream (01), Cold Rub(01), Roller Bandage 5 cm (02), Roller Bandage 10 cm (02), cotton Buds (10), First-Aid Guide booklet, Hand Sanitizer (02), Handiplast (12), Antiseptic cream (01), Antiallergic medicene, Cough medicene, Pain killer, Fever and cold medicene and any other essential medicene as directed by Engineer-in-Charge.
M & L for uprooting up to 30 cm depth grass/weeds/plant by scrapping soil in roder to made free ground from all sort of vegetation and hand packing by carefully packing round pebbles of size approximately of size 20 to 40mm after carefully picking form heap of pebbles/stones complete all as specified and directed.
M & L for cleaning of vegetation and supply & spray chemical for prevention of growth of weed and grass in the electrical substation with spray gun as per the manufacturer's instructions, complete. (Make : GLYCEL 41% SL or equivalent as approved by Engineer-in-Charge
Supply and spread unslaked lime in the electrical substation to destroy the roots of grass and herbs, complete all as specified and directed by Engr-in-charge
Supply and filling dry sand in surrounding of E/M installations / sub stations /cable trenches including watering and consolidation complete all as directed by Engineer-in-Charge.
Supply and filling dry fine river crushed stone aggregate free from any foreign particles 25mm gradded for spreading in electrical sub station complete all as specified and directed.
Demolition brickwork or stone/Boulder masonry, built in lime mortar, including all quoins, arches, pillars, etc, built in cement mortar or cement lime mortar complete all as specified and as directed.
M & L Brickwork with sub class ‘B’ bricks (old size), straight or curved on plan, exc 6 m mean radius, built in CM (1:6) complete.
M&L for rendering 15mm thick, on fair faces of brick work or concrete surface in cement mortar 1:6 surface finished even & smooth without using extra cement all as specified & directed.
M&L for preparing new surfaces of wall and applying two coat of white wash on walls complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of old steel surfaces of any description over 10 cm width or girth and applying one coats synthetic enamel paint complete all as specified and directed.
Demolition of concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed.
M&L PCC 1:2:4 type B-1 using 20mm graded stone agreegate as in coping, benching etc complete all as specified and directed by Engineer-in-Charge.
M&L 75 mm thick Cement concrete type C-2, 1:3:6 (40 mm graded stone aggregate) for base of path/ hard standing complete all as specified and directed by Engineer-in-Charge.
S&F in repair steel plates, plain or chequered Fe 410 -W (GdeE- 250) qualityA 5mm thick or over in thickness in given sizes complete for covering cable ducts inside the sub stations or in any other locations complete all as specified and directed. .
S&F in repair MCCB, 4 pole, 630 Amps current rating and ultimate breaking capacity ics=Icu =100% 36 KA with adjustable overload setting and having thermal magnetic release and to be fixed in distribution board, complete all as specified and directed.
S&F in repair MCCB, 4 pole, 400 Amps current rating and ultimate breaking capacity ics=Icu =100% 36 KA with adjustable overload setting and having thermal magnetic release and to be fixed in distribution board, complete all as specified and directed.
S&F in repair MCCB, 4 pole, 315 Amps current rating and ultimate breaking capacity ics=Icu =100% 36 KA with adjustable overload setting and having thermal magnetic release and to be fixed in distribution board, complete all as specified and directed.
S&F in repair MCCB, 4 pole, 250 Amps current rating and ultimate breaking capacity ics=Icu =100% 36 KA with adjustable overload setting and having thermal magnetic release and to be fixed in distribution board, complete all as specified and directed.
S&F in repair MCCB, 4 pole, 160 Amps current rating and ultimate breaking capacity ics=Icu =100% 36 KA with adjustable overload setting and having thermal magnetic release and to be fixed in distribution board, complete all as specified and directed.
S&F in repair MCCB, 4 pole, 125 Amps current rating and ultimate breaking capacity ics=Icu =100% 16 KA with adjustable overload setting and having thermal magnetic release and to be fixed in distribution board, complete all as specified and directed.
S&F in repair MCCB, 4 pole, 100 Amps current rating and ultimate breaking capacity ics=Icu =100% 16 KA with adjustable overload setting and having thermal magnetic release and to be fixed in distribution board, complete all as specified and directed.
S&F in repair MCCB, 4 pole, 63 Amps current rating and ultimate breaking capacity ics=Icu =100% 16 KA with adjustable overload setting and having thermal magnetic release and to be fixed in distribution board, complete all as specified and directed.
S&F in repair bus bar box made out of 2mm thick MS sheet, 3 Phase, 4 wire, 415 volts AC supply outdoor cubical type, dist and vermin proof, floor block mounting type suitable for outdoor applications of size 600mm x 600mm x 450mm, using 40mm x 40mm x5mm angle iron frame with shutter and locking arrangement painted with two coats of synthetic enamel paint of approved colour over a coat of red oxide primer (internally and externally) for box, height above ground 600mm and graouted 300mm below ground, legs of frame shall be grouted in PCC 1:2:4 (size 300 x 300 x 300mm block) and complete includig 40mm x 10mm 04 nos 500 mm long aluminium busbar fixed on insulators with proper colour coding including making connecteions with cable of size 300 sqmm with necessary lugs and chromium plated glands complete all as specified and directed.
M&L for Stringing of existing all ACSR’s conductors and earth wires including cradles, of 10 to 13 mm dia or any description, size & shape and in any position, as in LT overhead lines, on existing poles, including opening of connections and binding wires, restringing and tightening of all conductors/earth wire in position, removing sag, binding to insulators with new aluminum wire, making and connecting jumper connections etc. including commissioning and testing complete all as specified and directed. The quoted rates shall be deemed to include the following provisions also :- (i) Setting/adjusting etc in position of cradles. (ii) Adjusting & tightening of stay assembly wherever required. (iii) Trimming/cutting of all trees branches upto 1M distance from either side of nearest conductor/earth wire as directed at site.
Supply and fix in repair of aluminium conductor steel reinforced (ACSR) of any size/description on LT poles/lines, including stringing, tightening, binding to insulators with aluminium wire, making and connecting jumpers, connections, etc, including testing and complete+A9 all as specified & directed.
Supply and fix in repair Advanced Digital multifunction meter accuracy class 1 with load hour measurement, power factor measurement, Ammeter, Voltmeter, LED Display type Flush mounted 3 phase ,aux supply 230 volt AC.complete all as specified and as directed. Note: The cost of fixing the meter in the existing LT Panel with all connections, CT's etc., are deemed to be included in the quoted rate.
Supply and fix in repairs pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut of size 100 mm height, 65 mm dia for 1100 volts grade complete all as specified and directed.
Supply and fix in repair Shackle type 75mm height and 90mm dia insulator, porcelain, vitreous, white, brown or green including galvanised mild steel strap 31mm X 3mm, insulator bolts 12mm dia with suitable washers and nut, suitable for working pressure upto & including 1100 volts fixed on LT poles complete all as specified and directed.
Supply and fix PVC insulated spacers, 12mm dia flexible type suitable for making / turning to any shape and size and suitable for 4 conductor runs including disconnecting, dismantling and taking down existing unserviceable spacers of any description and in any position from the LT electric overhead lines of any height complete all as specified and directed.
Cutting & removing of grass/ shrubs / plants / bushes /Trimming of tree stems etc around the pole / LT panels / earthing pits of the 3 Sqm area complete all as specified and directed.
Supply and fix in repair danger notice plate of size LT 20x 15 cm,1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed to Existing LT Panel complete all as directed .
Supply and fix in repair danger notice plate of size HT 25x 20 cm,1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed to Existing Panel complete all as directed .
Supply, erecting and fixing in true vertical position, steel tubular swaged pole (410 SP – 31), 09 mtr long, complete with cast iron base plate, pole cap/finial taper plug, bolts, nuts and washers, welded reduced section and longitudinal weld throughout entire length of pole and 2 coats of black bituminous paint externally upto planting depth and remaining exterior portion of pole shall be provided with one coat of red oxide primer and two coats of aluminium paint and numbering of the poles shall be done with synthetic enameled painted letter of shape & size including taking down the old unserviceable poles complete all as specified and directed . Note: Necessary excavation in any type of soil shall deemed to be included in this item and PCC work shall be measured and paid separately.
Supply and fixing in replacement for energy saving environment friendly, long life exclusive innovative die cast aluminium IP-65 street light 70 Watt LED 6000K with high power LEDS as light source complete including suitable fixing arrangement on pole, pillar, wall with appropriate fasteners, nut, bolts, clamps and making connection with three core copper conductor cable not less than 1.5 sqmm complete all as specified and directed.
Supply and fixing in replacement for stay assembly complete with all accessories as shown in electrical plate No 1 of SSR, Part-I, comprising of 16mm dia stay rod with and including all necessary loop type insulator, stay clamps, necessary excavation and earth work in any type of soil and PCC works in (1:3:6) type C-2 (using 40mm graded stone aggregate) complete all as specified including taking down the old unserviceable stay assembly. Note: The cost of the inclusive of stay wire, insulator, excavation, and PCC work is deemed to be included in the quoted rate.
S&F GI pipe light grade bracket 40mm dia, 1.5m long bent to shape as required for fixing of street lights on poles/walls including nuts, bolts, washers , Clamps (02 sets) of suitable size complete all as specified and directed.
Supplying, laying, jointing, and testing XLPE insulated, armoured, heavy duty, aluminum conductor cable 1100 volts grade, laid in trenches/ducts, floors, fixed to walls, etc., complete all as specified and directed for the following sizes:-. Note: The cost of retriving the old cable is deemed to be included in the quoted rate.
16 Sqmm, 4 core
25 Sqmm, 4 core
35 Sqmm 3 ½ core
Supply and laying HDPE DWC flexible pipe of Size 50mm external & 38 mm internal dia (ISI marked) including required clamps/couplers to be fix at 1.5 mtr interval on wall to fix the pipe properly and smooth suitable for insulation & protection of GI /copper /aluminium strip of any size complete all as specified and directed.
M&L for for Horizontal directional drilling (HDD) Boring of holes under road, pavement, hard standing, Runway/ PTT by trenchless technology using manual technique and necessary machine including privison of HDPE pipe of sie not less than 100 mm dia suitable for 0.4 mpa working pressure complete all as specified and directed.
M&L for Earthing complete for panels with galvanised steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 m deep below normal ground level with top edge of earth plate, not less than 1.5 m below normal ground level connected to galvanised iron earth strip of size 32x6 mm using bolts, nuts/check nuts and washers etc of galvanised iron, connected to main switch/control board including necessary excavation & earth work in any type of soil and PCC 1:3:6 type C1 for earth chamber, 40 mm thick RCC cover slab 1:2:4 type B1 with 6 mm dia TMT Bars at 140 mm c/c both ways, watering pipe 20 mm dia light grade GI, funnel, wire mesh, lugs, charcoal and common salt etc complete all as shown in Electrical plate No. 3 of SSR Part I and testing complete including taking down old unserviceable items complete all as specified and directed. Note:- (i) GI strip and GI pipe medium grade, up to 7.5mtr shall be deemed to be included in the rates quoted for earthing. (ii) Excavation and earth work in any type of soil strata,PCC pit etc shall be deemed to be included in rates quoted for earthing.
M&L for preparation of old painted surfaces of LT steel tubular pole/strut, of any description and in any position 9.00/8.50 Mtr height and scrapping of pole with emery paper and applying one coat of aluminium paint on all the metallic surfaces including protection pipe, cross arms, clamps, GI pipe bracket of street/security light, anti climbing devices etc and providing three Nos radium band strips complete all as specified and directed.
Supply and fixing in repair PVC insulated and PVC sheathed twin core Aluminium conductor of size 10 Sqmm 2 core for connecting from the bus bar box to the street light fittings/ OH line to the street light fitting, complete all as specified and directed.
Supply, fixing, connecting and testing in replacement integral LED High bay light luminaries at any height of building/Hangar ranging from 3m to 16 m, 150 watts, with scondary optics made in pressure die cast housing and heat sink in aluminium extrusion with IP66 with mounting bracket and all accessories and connecting the same to electric source with using copper conductor 1.5 Sq mm PVC insulated flexible three core cable , including all accessories and fixing the light fitting to walls/ ceiling etc complete all as specified and directed.
Supply and fixing in repair Digital type Ammeter, Flush mounted of size 96 mm x 96 mm 3 3-phase, 0-200 Amps auxiliary supply 230 volt AC, including a necessary CT of suitable capacity, complete all as specified and as directed.
Supply and fixing in repair Digital type voltmeter, Flush mounted of size 96 mm x 96 mm 3 3-phase, 0-200 Amps auxiliary supply 230 volt AC, including a necessary PT of suitable capacity, complete all as specified and as directed.
Supply and fix in repair Indicating lamps for three phases R,Y,B for LT panel complete all as specified and as directed
Supply and fixing in repair ON Load change over switch 415V in sheet metal enclosure 4 pole 315 Amps Capacity, complete including necessary fixing accessories on wall / panel complete all as specified and as directed.
Supply and fixing in repair ON Load change over switch 415V in sheet metal enclosure 4 pole 630 Amps Capacity, complete including necessary fixing accessories on wall / panel complete all as specified and as directed.
Supply, Installed, Testing and Commissioning CPRI approved cubical type LT Panel floor mounted out door type for 415V, 3 phase 4 wire system 50 Hz AC supply with Copper bus bar duly colour coded, for neutral supported with DMC/SMC insulators colour coded with heat shrinkable sleeve having short circuit current with stand minimum 21 KA for one second complete connection from bus bar to breakers with suitable copper cable , factory made fabricated with CRCA sheet totally enclosed, dust weather and vermin proof for outer shell and 2 mm thick for inner shell having TPN cpper bus bar rating 1.5 times that of controlling MCCB supported on SMC insulator with short circuit withstand capacity 35 MVA for 1 second, bottom base channel MS section not less than 100mm x 50mm x 5 mm thick, entire panel shall have a common copper earth bar of size 25mm x 5mm at the rear with 2 Nos earth stud, solid connection from main bus bar to switchgears with required size of copper wiring with minimum 1.5 Sqmm PVC insulated copper conductor cable , cable alleys, cable gland plates in two half , general construction confirming to IS-8623/93 and mounted on suitable PCC foundation for the complete panel base with follwoing detailed specification & control complete with suitable fixing accessories at Tech Area
The panel board shall be fabricated from the reputed CPRI approved firm and shall be suitable to accommodate the following complete all as specified and directed :- OUTER SHELL :- The outer shell shall be made of 3. mm thick CRCA body & MS angle section 50x50x6 mm frame with front & back openable, single door system lockable/ openable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. The bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequite size of glands. The dimension of the outer shell should be adequite to accomodate inner shell described below figing 50 mm space all around and shall be fabricated in such a way that the comple inner shell alongiwth its control gears and accessories should be taken outside without disturbing outer sheel. The outer shell shall be mounted on a zinc metal coated stand. Provision of threaded earthing studs at bottom and lifting lugs of suitable size at top to lift the feeder pillar box safely shall be made. Computer cut self adhesive vinly danger notice plate having conventional symbol of bone and skull shall be providid. The degree of protection of outer shell shall be IP-54.
INNER SHELL :- Inner shell made of 2.0 mm thick CRCA body compartmentalized for each control gear, front openable single door system lockable/openable by keys from both sides having chromium plated fancy locks (2 Nos in each compartment) having louvers and air vents gasket for natural flow of air "U' type gasket shall be used to make the inner shell completely vermin proof and to accomodate incomer/outgoing MCCB's and TPN copper bus bar and extension links of rating not less than the 1.5 times rated capacity of the respective MCCB's. The TPN bus bar and extension links shall be insulated with colour coaded heat, shrikable sleeve and shall be mmounted on suitable size 'F' class through out the length of the TPN bus bar. Computer cut self adhesive vinyl danger notice plate having conventional symbol of bone and skull shall be providid on bus bar chamber. All control wires shall be with not less than 1.5 Sqmm multistranded copper conductor and shall be properly bunched. tied, ferruled for proper identification and crimped with adequite size of lugs. The cubical shall have a bottom channel of size 75x50mm duly coated with zinc metal coating. A detachable predrilled gland plate of thickness 3.15 mm zinc metal coated should be used at the bottom, indicating lamps LED type, 230 Volt, AC at the incomer of the unit to show three phase availablity at the incomer. An inspection lamp with 11 Watt CFL shall be fitted on top side of inner shell. The degree of protection for inner shell shall be IP-42 and carry the following controls. :-
(A) Incoming :- (a) MCCB 4P,400A, 50 KA ics= icu 100% -01(Electronic/Microprocesssor type) (b) Indicating lamps for three phases - Qty 1 set of 3 Nos (c) Power lamp inside the panel alongwith connection from incoming power supply . (B) Out going :- (a) MCCB 4P, 160A, 26KA ics= icu 100% -02 No (Adjustable magnetic type) (b) MCCB 4P, 100A, 16KA ics= icu 100% -04 No (Adjustable magnetic type)
All as per above item but with following switch gears with incoming and outgoing at Tech Area (A) Incoming :- (a) MCCB 4P,250A,ics= icu 100% 36 KA -01(Electronic/Microprocesssor type) (b) Indicating lamps for three phases - Qty 1 set of 3 Nos (c) Power lamp inside the panel alongwith connection from incoming power supply . (B) Out going :- (a) MCCB 4P,100A,ics= icu 100% 25KA -01No (Adjustable magnetic type) (b) MCCB 4P, 160A,ics= icu 100% 25KA -04No (Adjustable magnetic type)
All as per above item but with following switch gears with incoming and outgoing at Tech Area (A) Incoming :- (a) MCCB 4P,400A,ics= icu 100% 36 KA -01(Electronic/Microprocesssor type) (b) Indicating lamps for three phases - Qty 1 set of 3 Nos (c) Power lamp inside the panel alongwith connection from incoming power supply . (B) Out going :- (a) MCCB 4P, 160A,ics= icu 100% 25KA -04No (Adjustable magnetic type) (b) MCCB 4P, 100A,ics= icu 100% 16KA -04No (Adjustable magnetic type) Note (Applicable for item no 72,73 and 74):- The rate includes the cost of earth work and PCC for grouting the panel with angle iron of size 50 x 50 x 6 mm, 90 CM below the ground level and 60 CM above the ground level.
S&F in repair Cable jointing kit for 1.1 KV cable for straight-through heat shrink type joint complete with jointing material and accessories suitable for 4 core XLPE armoured aluminium conductor cable of size 16 sqmm.
S&F in repair Cable jointing kit for 1.1 KV cable for straight-through heat shrink type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured luminium conductor cable of size 25 sqmm to 50 sqmm.
Carrying out energy audit which includes detailed audit report as per the format given by the Engineer in charge with qualified technician as described below for complete LT distribution system from Transformer LT panel to Distribution board inside the building complete all as specified and as directed for the following location. The energy audit shall comprise of the following. i) Recording of insulation resistance values and EN voltage values of all the connected cables from the main LT panel at the substation to distribution boards with a calibrated digital or analog insulation resistance meter. ii) Recording of Earthing values in the specified format with a calibrated earth resistance meter digital or analog. iii) Tighten the loose contacts of all ACBs/MCCBs/MCBs inside the panel and Distribution boards and record voltage and current values with calibrated testers. iv) Complete report as per the format provided for each location.
a) 24 End OPR, LT panels inside the substation, LT Panels outside the Sub Station, Distribution Boards inside 04 no buildings and 04 Blast pens..Earthings - 20 Nos
b) Complete MAFI PS-1 and PS-2, 15 Nos ACB's, LT panels inside the sub station - 04 Nos, LT Panels outside the Sub Station, Distribution Boards, Servo Voltage 600 KVA Stabilizer, Isolation transformer 600 KVA inside the substation, earthgs - 25 Nos
c) 24 MMPU, LT panels with ACB inside the substation - 02 Nos, LT Panels with ACB outside the substation - 02 Nos, APFC Panel - 01 Nos, LT Panel inside MICA and ESH - 02 Nos, Geset AMF Panels - 02 Nos, flame-proof Distribution Boards inside the building.Mica and ESH - 20 Nos, Earthings - 45 Nos
d) Bomb dump substation, LT panels-03 Nos inside the substation, LT Panels-01 Nos outside the substation and building, Servo Voltage stabilizer 150 KVA, and flameproof Distribution Boards-20 Nos, Earthings - 45 Nos.of 25 MMPU and Central AC Plant.
e) 26 MMPU building LT panels near the building - 02 Nos, Servo Voltage Stabilizer, and flameproof Distribution Boards - 10 Nos, DG AMF Panel-01, Earthings- 45 Nos.
f) LT panel outside WSA-01 Nos, LT panels near the DB-15 Nos, and flameproof Distribution Boards inside and DB's Nos, Genset AMF Panels - 03 Nos, Servo Voltage Stabilizers-03 Nos Earthings - 150 Nos.
g) Tech flight LT panel with ACB-01 Nos inside the substation, DG 500 KVA AMF Panel - 01 Nos, Servo Voltage stabilizer -01 Nos, and all flame-proof distribution boards-40 Nos in 05 Nos storage buildings, Earthing pits - 50 Nos.
h) 954 Sqn Radar Complex LT Panel inside the substation - 01 Nos, APFC Panel - 01 Nos, Servo Voltage Stabilizer - 01 Nos, Isolation Transformer - 01 Nos, Earthing pit- 45 Nos, Building distribution boards - 15 Nos, Out door LT PAnels- 03 Nos complete.
M&L for PCC type C1 (1:3:6) (using 40mm graded aggregate) for foundation of poles struts & stay assembly etc complete all as specified and as directed.
M&L for PCC (1:3:6) type C1 in coping of poles etc (using 20mm graded coarse aggregate) including fair finishing the exposed surface even and smooth without using extra cement and necessary form work for coping of poles all as specified and directed for the following
S&F in repair: Aesthetically designed LED Street light fitting with an aluminium enclosure, powered by high-power LEDs as the light source, and featuring a die-cast heat sink. This design exhibits a classic Victorian look with symmetrical light distribution and excellent heat dissipation for long life.35 Watt capacity, mounted on a 40mm light-grade GI pipe, not less than 3m lay including necessary excavation, PCC work, PVC junction box 350 x 250 x 150mm with terminals, and a 6 Amp SP MCB, complete all as specified and as directed. Note:- Necessary excavation, PCC, PVC Junction box with terminals, and 6 Amp MCB SP is deemed to be included in the quoted rate.
M/S AUTOMATION AND SWITCHGEAR CONTROL (BID ID -3415425)
M/s Anupam Construction Co. (BID ID -3408013)
AUTOMATION AND SWITCHGEAR PANELS (BID ID -3408285)
BABA DEVELOPERS (BID ID -3411957)
m/s anil traders (BID ID -3415139)
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .