GE AF Amla
GE AF Amla, Betul Dist 460553 (MP)
REPAIR/ MAINTENANCE OF COOLING APPLIANCES AT AFS AMLA
2022_MES_509836_2
8468/E8 of 2021-2022
Open Tender
Civil Works
Item Rate
335 days
GE AF Amla
Please refer Tender documents
8 documents required · 8 mandatory
₹500
GE (AF) Amla
₹30,000
Yes
10 May 2022
8 Mar 2022
30 Mar 2022
8 Mar 2022
28 Mar 2022
15 Mar 2022
60 days
Amount
Materials and Labour for servicing of Window type AC of capacity 1.5 TR by flushing condenser, cooling coil and refrigerant pipe line including complete removal of dust, dirt, bugs, grease, oil etc., brazing the leakages if any in connection pipes of compressor, condenser, cooling coil, pressure testing, checking for leaks, dehydrating and vacuumizing to the standard as per OEM's recommendations, charging of refrigerant as per OEM's recommendations and including testing and commissioning complete all as specified and directed. Note :- (i) Cost of spare parts replaced/ refringent gas refilling shall be measured and paid separately as supply only under relevant items herein after. (ii) Labour charges for replacement of spares parts if any required during servicing of AC’s deemed to be included in the quoted rate. [OEM: Carrier/LG/Samsung/Godrej/Bluestar/Voltas/Hitachi/Sidwal].
Materials and Labour for servicing of Window type AC of capacity 2 TR by flushing condenser, cooling coil and refrigerant pipe line including complete removal of dust, dirt, bugs, grease, oil etc., brazing the leakages if any in connection pipes of compressor, condenser, cooling coil, pressure testing, checking for leaks, dehydrating and vacuumizing to the standard as per OEM's recommendations, charging of refrigerant as per OEM's recommendations and including testing and commissioning complete all as specified and directed. Note :- (i) Cost of spare parts replaced/ refringent gas refilling shall be measured and paid separately as supply only under relevant items herein after. (ii) Labour charges for replacement of spares parts if any required during servicing of AC’s deemed to be included in the quoted rate. [OEM: Carrier/LG/Samsung/Godrej/Bluestar/Voltas/Hitachi/Sidwal].
Supply and fixing in replacement of factory sealed compressor including charging of refrigerant gas R-22 suitable for window AC of 1.5 TR capacity as per OEMs specification including necessary welding/brazing work to existing refrigerant pipe line and testing on full load complete all as directed. Note: - (i) Factory sealed compressor unit shall be of existing capacity and make. (ii) The rate quoted deemed to be included for the gas required. [OEM: Carrier/LG/Samsung/Godrej/Bluestar/Voltas/Hitachi/Sidwal].
Supply and fixing in replacement of factory sealed compressor including charging of refrigerant gas R-22 suitable for window AC of 2 TR capacity as per OEMs specification including necessary welding/brazing work to existing refrigerant pipe line and testing on full load complete all as directed. Note: - (i) Factory sealed compressor unit shall be of existing capacity and make. (ii) The rate quoted deemed to be included for the gas required. [OEM: Carrier/LG/Samsung/Godrej/Bluestar/Voltas/Hitachi/Sidwal].
Blank
Material and labour for charging of following type of refrigerant gas suitable for window AC/ Split type AC/ Refrigerator/ Deep freezer/ Water cooler etc., after vacuumizing the complete system and pressure testing with nitrogen to ensure complete system is leak proof and finally functional testing the window AC/ Split type AC/ Refrigerator/ Deep freezer/ Water cooler etc., for cooling effect to the entire satisfaction of Engineer in Charge complete all as specified and directed. Note:- (i) Contractor has to refill the gas without any additional payment in case of any leakage/ shortage of gas/shortage of cooling effect.
Supply only following spares required for replacement during the process of servicing/ repairing/ refixing of the Window AC’s 1.5 / 2 TR:-
Running Capacitor 36 / 45 mfd.
Potential Relay.
Thermostat with knob suitable for Window AC 1.5/ 2 TR
Control Knob.
Blank
OLP suitable for compressor
Supply and fix in repairs double ended fan motor suitable for Window AC 1.5TR with capacity 1/6 HP as per OEM's specifications [OEM:Carrier/LG/Samsung/Godrej/Bluestar/Voltas/Hitachi/Sidwal]
Supply and fix in repairs double ended fan motor suitable for Window AC 2TR with capacity 1/4 HP as per OEM's specifications [OEM:Carrier/LG/Samsung/Godrej/Bluestar/Voltas/Hitachi/Sidwal]
Servicing the Voltage Stabilizer 3 KVA single phase after opening covers, taking out the burnt out winding from the transformer rewind with super enamelled copper winding wire, insulate properly, setting/testing of buck/boost relay, including replacement of unserviceable electronic parts, re-assemble and fixing in its original position including testing complete all as specified and directed.
Servicing the Voltage Stabilizer 4 KVA single phase after opening covers, taking out the burnt out winding from the transformer rewind with super enamelled copper winding wire, insulate properly, setting/testing of buck/boost relay, including replacement of unserviceable electronic parts, re-assemble and fixing in its original position including testing complete all as specified and directed.
Servicing the Voltage Stabilizer 5 KVA single phase after opening covers, taking out the burnt out winding from the transformer rewind with super enamelled copper winding wire, insulate properly, setting/testing of buck/boost relay, including replacement of unserviceable electronic parts, re-assemble and fixing in its original position including testing complete all as specified and directed.
Overhauling and servicing of split type ACs of capacity 1.5 TR at different locations of AF station by dismantling the internal & external units and component parts such as fan motor, blower, housing, filters etc., for cleaning and replacing worn out/ damaged parts including reassembling, connecting up and testing complete all as specified and directed. Tasks required to be carried out during overhauling/ servicing of Split-type AC: - (a) Inspection taking down, opening (dismantling) washing the condenser and cooling coil complete with chemical followed with pressurized water jet complete as required and cleaning with air blower and testing complete (b) Checking / examine operation of condenser, blower motor, cooling coil and checking the air circulation to ensure complete movement of working part trouble free (c) Inspection of leakage in system (cooling) and removal obstruction if any (d) Checking and correction earth continuity of electric items (e) Checking servicing thermostat and over load and other spares and test its functioning (f) Inspecting all electrical connection and remove if any defects (g) Checking servicing and greasing oiling of blower motor (h) Checking the functional of electronic remote-control unit to ensure satisfactory functioning of unit complete all as specified and as directed
Overhauling and servicing of split type ACs of capacity 2 TR at different locations of AF station by dismantling the internal & external units and component parts such as fan motor, blower, housing, filters etc., for cleaning and replacing worn out/ damaged parts including reassembling, connecting up and testing complete all as specified and directed. Tasks required to be carried out during overhauling/ servicing of Split-type AC: - (a) Inspection taking down, opening (dismantling) washing the condenser and cooling coil complete with chemical followed with pressurized water jet complete as required and cleaning with air blower and testing complete (b) Checking / examine operation of condenser, blower motor, cooling coil and checking the air circulation to ensure complete movement of working part trouble free (c) Inspection of leakage in system (cooling) and removal obstruction if any (d) Checking and correction earth continuity of electric items (e) Checking servicing thermostat and over load and other spares and test its functioning (f) Inspecting all electrical connection and remove if any defects (g) Checking servicing and greasing oiling of blower motor (h) Checking the functional of electronic remote-control unit to ensure satisfactory functioning of unit complete all as specified and as directed Notes for item no 13 & 14 of above: - (i) Cost of spare parts replaced shall be measured and paid separately as supply only under relevant items herein after. (ii) Cost of refringent gas refilled shall be measured paid separately under relevant items herein after (iii) Labour charges for replacement of spares parts if any required during servicing of AC’s deemed to be included in the quoted rate. (iv) Any break down of AC’s will be attended by the contractor within 24 hrs on receipt of complaints from MES through telephonic/written message. (v) Test Report shall be submitted by the contractor after testing
Supply and fixing in replacement of sealed compressor, rotary type, including charging of refrigerant gas R22, suitable for split type AC of 1.5 TR capacity as per OEM's specifications including necessary welding/ bracing work to existing refrigerant pipes line and testing on full load complete all as specified and directed. Note:- Rates quoted deemed to be included for the gas required for charging [OEM: Carrier/LG/Samsung/Godrej/Bluestar/Voltas/Hitachi/Sidwal].
Supply and fixing in replacement of sealed compressor, rotary type, including charging of refrigerant gas R22, suitable for split type AC of 2.0 TR capacity as per OEM's specifications including necessary welding/ bracing work to existing refrigerant pipes line and testing on full load complete all as specified and directed. Note: Rates quoted deemed to be included for the gas required for charging [OEM: Carrier/LG/Samsung/Godrej/Bluestar/Voltas/Hitachi/Sidwal].
Supply and fixing in replacement of sealed compressor, reciprocating type, including charging of refrigerant gas R22, suitable for split type AC of 1.5 TR capacity as per OEM's specifications including necessary welding/ bracing work to existing refrigerant pipes line and testing on full load complete all as specified and directed. Note: Rates quoted deemed to be included for the gas required for charging [OEM: Carrier/LG/Samsung/Godrej/Bluestar/Voltas/Hitachi/Sidwal].
Supply and fixing in replacement of sealed compressor, reciprocating type, including charging of refrigerant gas R22, suitable for split type AC of 2.0 TR capacity as per OEM's specifications including necessary welding/ bracing work to existing refrigerant pipes line and testing on full load complete all as specified and directed. Note: Rates quoted deemed to be included for the gas required for charging. [OEM: Carrier/LG/Samsung/Godrej/Bluestar/Voltas/Hitachi/Sidwal].
Supply only following spares required for replacement during the process of servicing/ repairing/ refixing of the split type AC’s 1.5 / 2 TR:-
Dual Capacitor Starting & running 45 / 50 MFD capacity 25 / 085 / 21 MPP SH for Split type AC 1.5 ton / 2.0 ton, Window AC 1.5 ton/ 2.0 ton
Running capacitor 36/6 MFD 440VAC.
Relays for Split type AC 1.5 ton / 2.0 ton.
Running capacitor 45/2.5 MFD 440VAC.
Running capacitor 50/6 MFD 440VAC.
Running capacitor 50/2.5 MFD 440VAC.
Starting Capacitor of 80 / 100 mfd for Split type AC 1.5 ton / 2.0 ton, Window AC 1.5 ton/ 2.0 ton
Starting Capacitor of 36 / 45 mfd for Split type AC 1.5 ton / 2.0 ton.
Potential Relay for Split type AC 1.5 ton / 2.0 ton.
Remote Control with cord wire for Split type AC 1.5 ton / 2.0 ton.
Air filter for Split type 1.5 ton / 2 ton.
Capillary tube and strainer for split AC 1.5/2 TR
IDU blower motor suitable for 1.5 TR split AC.
IDU blower motor suitable for 2.0 TR split AC.
Condenser fan blade suitable for 1.5 TR split AC.
Condenser fan blade suitable for 2.0 TR split AC
Condenser fan motor suitable for 1.5 TR split AC.
Condenser fan motor suitable for 2.0 TR split AC.
Taking down split type AC up to 2 TR from existing location by dismantling indoor & outdoor units alongwith other connected accessories carefully and shifting the same to other location and re-installing dismantled units of split type AC at the locations as directed by Engineer-in-Charge including provision of new brackets (L type) clamps, GI nuts, bolts and washers etc., required for fixing of indoor/ outdoor units, making good disturbed surface and testing complete all as specified & directed. Note:- (i) PVC pipe protection/ drain pipe/ control cable, extra copper tubing of any size for suction/ discharge will be measured and paid separately. (ii) Gas charging if required will be measured and paid separately.
Taking down window AC up to 2 TR from existing location alongwith all connected accessories carefully and shifting the same to other location and re-installing at the location as directed by Engineer-in-Charge including provision of new brackets (L type) clamps, GI nuts, bolts and washers etc., required for fixing, making good disturbed surface and testing complete all as specified and directed. Note:- (i) PVC pipe protection/ drain pipe/ control cable, extra copper tubing of any size for suction/ discharge will be measured and paid separately. (ii) Gas charging if required will be measured and paid separately.
Material and labour for leak testing of split type AC of capacity 1.5/2 TR by dismantling indoor/ outdoor unit from installed position and arresting the leakages in condenser coil by brazing etc. including gas charging, re-fixing in same position and testing complete all as specified and directed. Note: Gas charging if any required will be measured and paid separately.
Supply and laying in replacement of refrigerant line copper tubing of size 5/8" with clamping on wall surface or concealed with both the ends connection as in repair complete all as specified and as directed by Engineer-in-charge
Supply and laying in replacement of refrigerant line copper tubing of size 3/8" with clamping on wall surface or concealed with both the ends connection as in repair complete all as specified and as directed by Engineer-in-charge
Supply and laying in replacement of refrigerant line copper tubing of size 1/2" with clamping on wall surface or concealed with both the ends connection as in repair complete all as specified and as directed by Engineer-in-charge
Supply and laying in replacement of refrigerant line copper tubing of size 1/4" with clamping on wall surface or concealed with both the ends connection as in repair complete all as specified and as directed by Engineer-in-charge
M&L for insulation to copper tubing of split type AC of cap 1.5 TR/ 2.0 TR with heavy duty rubber foam insulation as per existing density and thermal conductivity including packing material and pvc tie complete all as specified and directed by Engr-in-Charge.
M&L for rewinding condenser fan motor retrieved from split type AC of capacity 1.5 TR with suitable gauge winding wire, insulating papers, varnish etc., including taking down old motor from existing split AC and transporting it to civil work shop for winding, replacing ball bearing, shifting back to same location, refixing and testing complete all as specified and as directed.
Taking out AC Manager from position after by passing the power supply to split ACs, servicing the load manager for pro switching on/ off two Nos split ACs and re-fixing in same position complete all as specified and directed. Note: Spares shall be measured and paid separately.
S&F in repairs AC load manager with built in programme for on/ off of 2 Nos of 1.5 TR/2 TR capacity split type Acs suitable for operating on single phase 230 volts all as specified and directed.
Supply and fixing in replacement of copper condenser coil unit suitable for 1.5 TR window/ split type AC as per OEM's specification including charging of refrigerant gas R22 and welding/ bracing work etc., complete all as specified and directed. Note: Rates quoted deemed to be included for the gas required for charging [OEM: Carrier/LG/Samsung/Godrej/Bluestar/Voltas/Hitachi/Sidwal].
Supply and fixing in replacement of copper condenser coil unit suitable for 2 TR window/ split type AC as per OEM's specification including charging of refrigerant gas R22 and welding/ bracing work etc., complete all as specified and directed. Note: Rates quoted deemed to be included for the gas required for charging [OEM: Carrier/LG/Samsung/Godrej/Bluestar/Voltas/Hitachi/Sidwal].
Supply and fixing in repair Indoor Unit 1.5 TR for Split AC comprising of specification as per OEM's including provision of drain pipe, connecting up etc., and taking down old unserviceable indoor unit and testing complete all as specified and directed. [OEM: Carrier/LG/Samsung/Godrej/Bluestar/Voltas/Hitachi/Sidwal].
Supply and fixing in repair Indoor Unit 2 TR for Split AC comprising of specification as per OEM's including provision of drain pipe, connecting up etc., and taking down old unserviceable indoor unit and testing complete all as specified and directed. [OEM: Carrier/LG/Samsung/Godrej/Bluestar/Voltas/Hitachi/Sidwal].
Supply and fixing in repair swing motor suitable for split AC 1.5 TR with necessary accessories complete all as specified and directed.
Supply and fixing in repair swing motor suitable for split AC 2 TR with necessary accessories complete all as specified and directed.
Supply and fixing in repairs of electronic circuit board PCB suitable for window/split type AC indoor unit of any capacity as per the existing model & make complete all as specified and directed.
Material and labour for repairing/servicing of PCB of split/window AC with change of necessary spare parts/items as required and testing complete all as specified and directed.
S&F in repairs of PVC insulated and sheathed multistranded copper conductor cable 3 core of size 4 sq.mm dia for external connection of AC & voltage stabilizer complete all as specified and directed.
S&F in repair of PVC insulated and sheathed multistranded copper conductor cable 3 core of size 2.5 Sq.mm dia for external connection of water cooler, Refrigerator & voltage stabilizer complete all as specified and directed.
S&F in repair brass valve1/4" suitable for existing split AC of cap 1.5/ 2.0 TR complete all as directed.
S&F in repair brass valve1/2" suitable for existing split AC of cap 1.5/ 2.0 TR complete all as directed.
S&F in repair brass valve 5/8" suitable for existing split AC of cap 1.5/ 2.0 TR complete all as directed.
S&F in repair brass valve 3/8" suitable for existing split AC of cap 1.5/ 2.0 TR complete all as directed.
Supply and fixing PVC flexible conduit pipe 20mm dia medium grade including all accessories for drain out pipe all as directed.
Material and labour for servicing water coolers of 40 / 80 ltrs capacity complete with cleaning condenser coil with air blower, wet servicing of condensor coil unit with caustic soda etc, replacement of sheet metal screws wherever necessary applying oil in fan motor bushes checking and rectifying the wiring defects, proper setting of thermostat & other electrical/ refrigerant controls, connecting up all connections and testing all as directed.
Material and labour for servicing water coolers of 60 / 120 ltrs capacity complete with cleaning condenser coil with air blower, wet servicing of condensor coil unit with caustic soda etc, replacement of sheet metal screws wherever necessary applying oil in fan motor bushes checking and rectifying the wiring defects, proper setting of thermostat & other electrical/ refrigerant controls, connecting up all connections and testing all as directed.
Material and labour for servicing water coolers of 150 / 150 ltrs capacity complete with cleaning condenser coil with air blower, wet servicing of condensor coil unit with caustic soda etc, replacement of sheet metal screws wherever necessary applying oil in fan motor bushes checking and rectifying the wiring defects, proper setting of thermostat & other electrical/ refrigerant controls, connecting up all connections and testing all as directed.
Supply and replacement factory sealed compressor unit as per OEM’s Specification suitable for water coolers 40 / 80 Ltrs per Hr of cooling capacity, connecting refrigeration system after thoroughly flushing out the system and leak testing with CO2, vacuumising and gas charging with refrigerant gas, testing, re-installing in its original position/location connecting up all electrical connections, testing the complete unit all as directed. Notes:- (i) Sealed compressor unit shall be replaced with existing capacity/Make. (ii) The rate quoted deemed tobe included for the gas required.
Supply and replacement factory sealed compressor unit as per OEM’s Specification suitable for water coolers 60 / 120 Ltrs per Hr of cooling capacity, connecting refrigeration system after thoroughly flushing out the system and leak testing with CO2, vacuumising and gas charging with refrigerant gas, testing, re-installing in its original position/location connecting up all electrical connections, testing the complete unit all as directed. Notes:- (i) Sealed compressor unit shall be replaced with existing capacity/Make. (ii) The rate quoted deemed tobe included for the gas required.
Material and labour for arresting the leakages in condenser coil of water cooler 40/ 60 Ltrs per Hr cooling capacity by brazing etc., complete all as specified and directed. Note: - (i) Gas charging shall be measured and paid separately under relevant item
Supply only following spares required for replacement during the process of servicing/ repairing of Water Cooler herein before.
Starting capacitor 10 Mfd
Starting capacitor 6 Mfd
Starting capacitor 4 Mfd
Running capacitor 10 Mfd
Running capacitor 6 Mfd
Running capacitor 4 Mfd
Thermostat for water cooler 40 Litres / Hr or 60 litres/ Hr cooling capacity.
Potential relay for water cooler of 40Ltr/Hr or 60 Ltrs/Hr cooling capacity.
OLP suitable for compressor.
Fan motor suitable for water cooler capacity 40 Ltrs/Hr or 60 Ltrs/Hr cooling capacity
Fan blade of same size and design as existing at site.
Brass chromium plated push button tap outer/Inner thread suitable for water cooler of any type of size 15 mm
Copper Capillary tube-0.40 mm
Drier filter
Copper Condensor coil for water cooler 40/60 Ltrs/Hr cooling capacity.
Copper Condensor coil for water cooler 60/120 Ltrs/Hr cooling capacity.
15mm bore PVC ball valves high pressure with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe.
PVC connections pipe 15mm size with PTMT nuts of length 450mm
S&F in repairs of PVC flexible pipe 32 mm dia for water cooler drain out pipe complete all as specified and directed.
M&L for cleaning of the water cooler; cold water tank of storage of capacity upto 150 Liters by using PVC wire scrubber to remove dirt, scales from tank and washing the tank with bleaching powder to make the tank bacteria free and disposing off the rubbish/dirty water safely in low lying areas of defence land, writing “TANK CLEANED ON…..”(date), “DUE DATE ON…..(date) with 5 cm height x 5cm breadth size white letters on black back ground by engaging skilled artist using best quality synthetic enamel paint complete all as specified and directed. Note: Contractor has to maintain a register for cleaning of tank duly obtaining signature from user and Engineer-in-Charge for record.
Repairs to water cooler body, base frame with legs, door unit, storage tank, FHP motor base etc. of any capacity & make by cutting worn out / deteriorated portions of sheet steel and reconstructing body including providing ventilation grooves, hinges where required and steel storage tank to the existing shape and size using PGI sheet of 16 / 20 SWG as per the existing, necessary welding / bracing work to match with the existing surface, including all necessary items such as nuts, bolts, washers, drilling holes etc. and applying two coats of synthetic enamel paint on the affected previously painted area using spray gun over a coat of red oxide primer matching with the existing tint & shade complete all as specified and directed.
M&L for half yearly maintenance/ repair/ servicing of water purifier of any type and brand by taking down, dismantling, cleaning and replacing worn out/damaged parts such as carbon filter, UV lamp etc., including reassembling, refixing, connecting up and testing complete all as specified and directed. Note: (i) Cost of spare parts replaced during the process of repair/servicing shall be measured and paid separately as supply only under relevant item herein after. (ii) Labour charges for replacement of spares parts if any required during repair/ servicing deemed to be included in the quoted rate.
Supply only following spares required for replacement during the process of servicing/ repairing of water purifier herein before.
Carbon filter suitable for Aqua Guard/ Aqua Plus UV, RO, UF+
Carbon filter suitable for Kent UV, RO, UF+
UV Lamp Suitable fot Aqua guard/ Kent purifier
Suppy only booster pump of 100 GPD capacity
Material and labour for servicing Refrigerators up to 165 Ltrs capacity complete with cleaning condenser coil with air blower, wet servicing of condenser coil unit with caustic soda etc, replacement of sheet metal screws wherever necessary, checking and rectifying the wiring defects, proper setting of thermostat & other electrical/ Refrigerent controls, connecting up all connections and testing all as directed.
Material and labour for servicing Refrigerators 165 - 320 Lts capacity complete with cleaning condenser coil with air blower, wet servicing of condenser coil unit with caustic soda etc, replacement of sheet metal screws wherever necessary, checking and rectifying the wiring defects, proper setting of thermostat & other electrical/ Refrigerent controls, connecting up all connections and testing all as directed.
Supply and fixing in repairs factory sealed compressor unit suitable for refrigerator of capacity upto 165 Ltrs as per OEM's specification including taking down old unserviceable compressor, connecting up with copper piping by brazing & Copper tubing etc. complete all as specified and directed. Note:- (i) Sealed new compressor unit supplied by the contractor shall be of same capacity existing as per site and also conform to OEM’s specification of existing make. (ii) The rate quoted deemed to be included for the gas required.
Supply and fixing in repairs factory sealed compressor unit suitable for refrigerator of capacity above 165 to 320 Ltrs as per OEM's specification including taking down old unserviceable compressor, connecting up with copper piping by brazing & Copper tubing etc. complete all as specified and directed. Note:- (i) Sealed new compressor unit supplied by the contractor shall be of same capacity existing as per site and also conform to OEM’s specification of existing make. (ii) The rate quoted deemed to be included for the gas required.
Material and labour for arresting the leakages in condenser coil of Refrigerator of capacity upto 285 Ltrs by brazing etc., complete all as specified and directed. Note: - (i) Gas charging shall be measured and paid separately under relevant item of BOQ.
Supply only following spares required for replacement during the process of servicing/ repairing of refrigerator herein before.
Thermostat for Refrigerator 165 Ltrs / 250/320 ltrs.
Box type Relay for Refrigerators 165 Ltrs / 250/320 Ltrs.
OLP for Refrigerator 165 Ltrs / 250/320 ltrs
Auto defrost Thermostat switch complete
Pigmay bulb (Thick/Thin Thread) 230 Volt complete
Freezer Fan motor (as per sample) single phase 230 Volt, 50 Hz suitable for refrigerator of capacity 165 to 320 Ltr (Make : Marathon Electric / Frac Master / M Bajaj Electric)
Bi-metal for refrigerator
Timer for refrigerator
Material and labour for servicing Deep freezer upto 310 Lts capacity complete with cleaning condenser coil with air blower, wet servicing of condenser coil unit with caustic soda etc, replacement of sheet metal screws wherever necessary, checking and rectifying the wiring defects, proper setting of thermostat & other electrical/ Refrigerent controls, connecting up all connections and testing all as directed.
Supply and fixing in repairs factory sealed compressor unit suitable for Deep freezer of capacity 310 Ltrs including taking down old unserviceable compressor, connecting up with copper piping by brazing & Copper tubing etc. complete all as specified and directed. Note:- (i) Sealed new compressor unit supplied by the contractor shall be of same capacity existing as per site and also conform to OEM’s specification of existing make. (ii) The rate quoted deemed tobe included for the gas required.
S&F in repair fan motor suitable for existing deep freezer 310 ltr cap complete all as directed.
Repair/servicing of desert cooler of capacity upto 3000/4000 CFM by dismantling the fan, motor, pumps etc., including checking up/ rectification of wire connections, replacement unserviceable parts & accessories, cleaning of the water tank, replacement of piping system, khas pads, reassembling, connecting up and testing complete all as specified and directed. Note :- (i) Cost of spare parts replaced during the process of repair/servicing shall be measured and paid separately as supply only under relevant item herein after. (ii) Labour charges for replacement of spares parts if any required during repair/ servicing deemed to be included in the quoted rate.
Supply only following spares required for replacement during the process of servicing/ repairing of desert cooler herein before.
Supply only electric motor suitable for desert cooler fan of size 18" / 20" sweep, single phase 3 speed 100% water resistance, 100% dust proof withstand, voltage fluctuation 170 V - 270 V, rust proof totally enclosed with double ball bearing 900-1400 RPM, electric connection with copper cable of appropriate gauage all as specified and directed.
Supply only submersible pump 230 volts single phase suitable for desert cooler of cap 3000 CuM / Hr to 4000 CuM / Hr complete all as specified and directed.
Supply only wood wool pad (set of 03 Nos) heavy duty weight not less than 750 gm suitable for desert cooler of cap 3000 CuM / Hr to 4000 CuM / Hr complete all as specified and directed.
Supply only fan blade for desert cooler complete all as directed.
Supply only mounting bracket for fan motor with nut and bolts etc of desert cooler complete all as directed.
Supply only capacitor for 2.5/4MFD
Supply only capacitor for 5/6 MFD.
S&F in repairs single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of capacity 20 to 32 A
Supply and fixing in repair electronic voltage stabilizer single phase rating 12 Amps working range 170V-270V suitable for air conditioner/water coolers of capacity 4 KVA including depositing old u/s stabilizer to MES store all as specified and directed.
M & L for submain wiring with approved colour coding as per IS with single core PVC insulated but unsheathed FRLS cable of specified size multistranded copper conductor 1100 volts grade IS-694 marked drawn through through heavy duty ISI marked surface mounted PVC conduit, not less than 20mm dia with and including fittings all as per relevant IS all as specified complete for the following size:-
2 runs of 4 Sqmm size main cable and one run of 2.5 Sqmm size earth continuity conductor
Note:- The amount against the Schedule of Credit mentioned in the tender document shall be deducted from the total amount quoted against Sch 'A' while deriving the Contract Sum for Acceptance.
M/s Vinod Yadav
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .