Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.9 LAccepted-AOC | L1 | Accepted-AOC Lowest tender accepted | |
| 2 | L2₹2.9 L+₹1,550 (0.54%)Rejected-Finance | L2 | Rejected-Finance Other than lowest tender | |
| 3 | L3₹2.9 L+₹4,650 (1.61%)Rejected-Finance | L3 | Rejected-Finance Other than lowest tender | |
| 4 | L4₹2.9 L+₹5,500 (1.90%)Rejected-Finance | L4 | Rejected-Finance Other than lowest tender |
Tender Value
Refer Docs
Closing Date
8 Oct 2024, 6:00 pmClosed
GE (AF) Subroto Park Delhi Cantt
GE (AF) Subroto Park Delhi Cantt
PROVISIONING OF LT CABLING AND CONNECTING ACCESSORIES FOR INDOOR STADIUM AT SPORTS GROUND UNDER GE (AF) SUBROTO PARK
2024_MES_676811_1
3104/007/E3
Limited
Miscellaneous Works
Piece-work
30 days
Delhi Cantt
Please refer tender documents
1 document required · 1 mandatory
₹0
Exempted
14 Nov 2024
26 Sept 2024
10 Oct 2024
28 Sept 2024
8 Oct 2024
28 Sept 2024
Amount
JOB ORDER FOR : PROVISIONING OF LT CABLING AND CONNECTING ACCESSORIES FOR INDOOR STADIUM AT SPORTS GROUND UNDER GE (AF) SUBROTO PARK The following work are urgently required :-
Supply, Laying, Testing and connecting cable XPLE insulated armoured heavy duty electric cable with stranded aluminium conductor 1100 volts grade cross section area of 70 sqmm x 3.5 core copmlete all as directed by engineer-in-charge. KEI/Kalinga/Havells .Qty-110RM
Supply, Laying, Testing And Connecting Cable XLPE Insulated Armoured Heavy Duty Electric Cable With Stranded Aluminium Conductor 1100 Volts Grade Cross Section Area Of 25sqmm X 3.5 Core Complete All As Directed By Engineer-In-Charge. KEI/Kalinga/Havells. Qty-20RM
M&L for Fabricate, supply and install cubicle type, CPRI approved LT panel board, outdoor type, totally enclosed, dust & vermin proof (protection class IP 65) front opening with self locking arrangement made out of MS angle iron frame work, MS flat iron and CRCA sheet of 3.15 mm thick as per IS 5039 duly painted with powder coated paint of approved shade. The panel shall be suitable for 415 volts, 50 hz, 3 phase 4 wire system and shall be complete with 320 amp capacity copper bus bar, wiring the panel board with suitable size of PVC insulated, multi stranded cooper cables and all connected accessories required for functioning of panel board such as thimbles, glands, bolts, nuts, washers, etc including supply and fixing following accessories:- Qty- Each -01 INCOMING (a) MCCB 200 Amps, 4 poles, 25 KA DPX3 MCCB with Thermal Magnetic Protection Unit make Legrand equivlent make of Havells/ Simens/Schinder – 01 Nos (b) Digital type voltmeter – set 01 (c) Digital type ammeter with suitable rating CTs conforms to relevant IS specification,- set 01 (d) LED type indicator lamp set of red, yellow, and blue – set 01 OUTGOING (a) MCB 63 amps, 4 poles, 25 KA DPX3 63 of make Legrand/ Schinder/C&S – 03 Nos for Trishul House garden light Total=04 Nos (b) MCB 63 amps, 2 poles, 25 KA DPX3 63 of make Legrand/ Schinder/C&S – 02 Nos for Trishul House garden light Total=04 Nos Foundation- (i) Plateform for the panel with PCC 1:2:4 type D-2 with 40mm graded crushed stone 15 cm thick in foundation brick work in 1.6 with sub class “B” old size bricks with sandering 15mm in CM 1:6 of exposed surface and 100 mm thick PCC padding 1:3:6 type C-1 using 20mm graded crushed stomneaggregate on top plate from shall be such that it is of a height 45cm above nearest road level
M&L earthing complete with galvanized steel plate electrode 600x600x6.3mm, buried vertically in ground ( earth pit not less than 2.25 m deep below normal ground level) with top edge of plate vertically to a depth not less than 1.5 m below ground level, connected to galvanized steel earth lead wire 4.00 mm dia ( 8 SWG) of any length as reqd at site, by means of bolts, nuts, check nuts and washers of galvanized steel, earth lead wire encased in and including 15mm bore G.I light grade pipe from earth plate upto pole, upto 2.40 m height from GL by means of and including 25x3 mm M.S.F.I Clamps, bolts, nuts and washers etc. and GI Earth lead wire poles/feeders, gang operated air break switches etc with provision of charcoaldust and common salt packed all around the earth plate, including necessary excavation and earth work in any type of oil/ strata and testing complete all as specified and directed and shown on electrical plate No. 5 of SSR Part I (1991). Note – GI Wire more than 7.5m will be measured separately. Qty-2 Each
Supply and fix 4 mm dia GI wire all as specified and directed by Engr-in-charge. Qty-10RM
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in deep for foundation of pole/stay/cable etc and getting in soft/loose soil complete all as specified and as directed by engineer- in-charge.Qty-25Cum
Returning refilling including spreading, leveling , watering and well raming in layers each not exceeding 25 cm thickness complete all as specified and as directed by engineer- in-charge. Qty-9Cum
Removing surplus spoil to a distance not exceeding 50 m and deposited where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed by engineer- in-charge.Qty-16Cum
Sand cushioning for under ground cables provided with a layer of sand 8 cm deep before laying the cable and 15cm depth after punning down and stretching the cables all as specified and directed by engineer- in-charge.Qty-8Cum
Supply and laying GI pipes light grade galvanized with all fittings laid in trenches or fix on wall for cables protection of 40 mm bore complete all as directed by engineer- in-charge. Make- Jindal/Swastik/Tata . Qty-5RM
Material and labor for cutting of road/ hard standing up to a size not exceeding 20 cm width and not exceeding 60 cm in depth for laying of cable protection pipe including making good the disturbed road/hard standing by providing PCC (1:2:4) type B1 and block top with black bituminous upto existing surface level completer all as specified and directed by engineer- in-charge. Qty-5RM
M&L For PCC type D- 2 (1:4:8) using 40mm graded stone aggregates in foundation incl necessary from work and fair finis to exposed surface without using extra cement etc. complete all a specified. Qty-0.8Cum
Supply and lay well burnt as class “B” bricks as mechanical protection to under ground cables laying with length of bricks equal to the width of the trench all as specified and directed by engineer- in-charge .Qty-480Each
NOTE:- (a) AGE E/M-I Demand No 305-A/02/EM-I dated 22 May 2024 (b) CH Head : 51/757/00 .
M/S LADPURIA ENTERPRISES (BID ID -3132138)
Laxmi traders (BID ID -3131385)
M/s. Kansal Construction Co. (BID ID -3131392)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_756895.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .