Loading…
Tender Value
₹46.4 L
EMD Value
₹92,900
Closing Date
7 Sept 2026, 3:00 pm
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Deposit Work
Above/Below/Par
SIG/NORTH
14 conditions · 5 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
The tenderer shall clearly specify whether the tender is submitted on his own or on behalf of a partnership concern. If the tender is submitted on behalf of a partnership concern, he should submit the certified copy of partnership deed (PD) along with the tender and authorization to sign the tender documents on behalf of partnership firm. If these documents are not enclosed along with the tender documents, the tender will be treated as having been submitted by individual signing the tender documents. The tenderer whether sole proprietor, a limited company or a partnership firm if they want to act through agent or individual partners should submit along with the tender or at a later stage, a power of attorney(POA) duly stamped and authenticated by a Notary public or by Magistrate in favour of the specific person whether he or they be partners of the firm or any other person specifically authorizing him or them to submit the tender, sign the agreement ,receive money, witness measurement, sign Measurement Books, compromise, settle, relinquish any claims preferred by the firm and signed No claim certificate and refer all or any dispute to arbitration.
Tenderer should clearly state the status of firm and submit the relevant document in support of authentication, in absence of following/relevant documents the offer of tenderer is summarily rejected: (A)Self-declaration /proprietorship certificate in case of proprietor firm along with POA if any. (B) Partnership deed and power of attorney in case of partnership firm. (C)Certified copy of an extract of resolution passed by the board of directors in case of limited firm or Private Limited Company
(a) Sole Proprietorship Firm: (i)All documents in terms of Para 10 of the Tender Form (Second Sheet)of Tender document
(b) HUF: (i)A copy of notarized affidavit on Stamp Paper declaring that he who is submitting the tender on behalf of HUF is in the position of 'Karta' of Hindu Undivided Family (HUF) and 1.1.2 he has the authority, power and consent given by other members to act on behalf of HUF. (ii)All other documents in terms of Para10 of the Tender Form (Second Sheet)of Tender document
(c) Partnership Firm: (i)All documents as mentioned in para18 of the Tender Form document
(d) Company registered under Companies Act2013: (i)The copies of MOA (Memorandum of Association) / AOA (Articles of Association) of the company (ii)A copy of Certificate of Incorporation(iii)A copy of Authorization/Power of Attorney 1.1.4 issued by the Company (backed by the resolution of Board of Directors) in favour of the individual to sign the tender on behalf of the company and create liability against the company. (iv)All other documents in terms Para 10 of the Tender Form (Second Sheet) of Tender document
(e) LLP (Limited Liability Partnership): (i)A copy of LLP Agreement (ii)A copy of Certificate of Incorporation (iii)A copy of Power of Attorney/Authorization issued by the LLP in favour of the individual to sign the tender on behalf of the LLP and create liability against the LLP. (iv)An undertaking by all partners of the LLP that they are not blacklisted or debarred by Railways or any other Ministry / Department of the Govt. of India from 1.1.5 participation intenders / contracts as on the date of submission of bids, either in their individual capacity or in any firm/ LLP or JV in which they were/ are partners/members. Concealment /wrong information in regard to above shall make the contract liable for determination under Clause 62 of the Standard General Conditions of Contract.(v)All other documents in terms of Para 10 of the Tender Form(Second Sheet).
(f) Registered Society & Registered Trust: (i)A copy of Certificate of Registration (ii)A copy of Memorandum of Association of Society/Trust Deed (iii)A copy of Power of Attorney in favour of 1.1.6 the individual to sign the tender documents and create liability against the Society/Trust. (iv)A copy of Rules & Regulations of the Society (v)All other documents in terms of Para 10 of the Tender Form (Second Sheet) of tender document
Information as per Para 16 of GCC Part (1)(Tender form second sheet Annex-I) related to Employment/Partnership Etc. of Retired Railway Employees and Clauses 59 (9) & 62 (1) (xv) to GCC regarding employment etc. Of retired government officers by railway contractors
Certificate of Information regarding EMPLOYMENT/PARTNERSHIP etc. of Retired Railway Employees with the tender as per the attached proforma, Format 11 of tender document
Certificate of NO RELATIVE being an employee of Western Railway as per attached Performa Format10 of Tender document
Signalling work in connection with (1) Proposed 2 lane Road Over Bridge in lieu of LC. No. 81 at NWU Km 131/1-2.(2) Construction for crossing of MS pipeline with RCC box pushing at NDN Km 221/29-31 of Udhna- Jalgaon Section of Mumbai Division.
SG_216_2_71_132_WA~WR
SG_216_2_71_132_WA
Open
Works - General
6 Months
Mumbai, Maharashtra
₹0
₹92,900
11 Aug 2026
11 Aug 2026
24 Aug 2026
144 items across 2 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 26,68,134.71 | ||
| — | 2.00 | — | — | ||
| SS Location box made of Spl Grade SS 304 of size as per Drg. No.DRM/SG/948 dt. 26.04.2011 (Single app. Case) or latest. Manufacturer's certificate in regard to grade of stainless steel and its protection level shall be submitted at the time of supply. | — | — | — | 1,19,711.96 | |
| — | 2.00 | — | — | ||
| SS Location box made of Spl Grade SS 304 of size as per Drg. No. DRM/SG/945 dtd 03.03.2011 (Half app. Case) or latest.Manufacturer's certificate in regard to grade of stainless steel and its protection level shall be submitted at the time of supply. | — | — | — | 1,03,996.12 | |
| — | 4.00 | — | — | ||
| IS 13410: Glass Reinforced Polyester Sheet Moulding Compounds (SMC) Size of Sheet : 1000x1000x8. | — | — | — | 21,554.68 | |
| — | 4.00 | — | — | ||
| Phenolic laminated Sheet,grade P3 in standard size of1220 X 1220 x 10 mm as perspec. No IS 2036 of 1995 orlatest. Test report ofmanufacture to be supplied. | — | — | — | 17,771.72 | |
| — | 2.00 | — | — | ||
| Excavation and Casting of Apparatus Case foundation with contractor's own materials including cement and anchor bolts of standard size. The required scaffolding Ferma etc. for Casting of foundation will have to be brought by the contractor at his own cost.Single Case as per Drg No SK 748 or CSTE/5074 or SS Location | — | — | — | 14,325.26 | |
| — | 2.00 | — | — | ||
| Excavation and Casting of Apparatus Case foundation with contractor's own materials including cement and anchor bolts of standard size. The required scaffolding Ferma etc. for Casting of foundation will have to be brought by the contractor at his own cost.Half Case as per Drg No SK 747or CSTE/5074 or SS Location. | — | — | — | 10,975.72 | |
| — | 2.00 | — | — | ||
| Installation of Apparatus Cases with miniature 'E' type lock on CC foundation. This includes filling of location foundations with river bed sand and plastering on top of the sand. 'E' Type lock will be provided by Railway.Single Case | — | — | — | 2,152.58 | |
| — | 2.00 | — | — | ||
| Installation of Apparatus Cases with miniature 'E' type lock on CC foundation. This includes filling of location foundations with river bed sand and plastering on top of the sand. 'E' Type lock will be provided by Railway.Half Case | — | — | — | 1,314.3 | |
| — | 2.00 | — | — | ||
| Fabrication and fixing of SMC sheet in location box by providing all fixtures as per Railway Drawing including fixing of PVC coated string rods at the back side for cable support with contractor's own materials. The work shall be done as per Drg and arrangement similar to SK 783- 1/2. With latest alterations & as per instructions of Rly engineer at site. Single Case | — | — | — | 4,890.72 | |
| — | 2.00 | — | — | ||
| Fabrication and fixing of SMC sheet in location box by providing all fixtures as per Railway Drawing including fixing of PVC coated string rods at the back side for cable support with contractor's own materials. The work shall be done as per Drg and arrangement similar to SK 783- 1/2. With latest alterations & as per instructions of Rly engineer at site.Half Case | — | — | — | 1,555.56 | |
| — | 2.00 | — | — | ||
| Lettering / Numbering Termination particulars, equipments names etc., legibly and neatly inside location boxes. This includes supply of paints of Asian Paints/ Nerolac / Dulux / Berger make. Full Case. | — | — | — | 258.52 | |
| — | 2.00 | — | — | ||
| Lettering / Numbering Termination particulars, equipments names etc., legibly and neatly inside location boxes. This includes supply of paints of Asian Paints/ Nerolac / Dulux / Berger make. Halfl Case. | — | — | — | 176.36 | |
| — | 900.00 | — | — | ||
| ARA Terminal blocks with links made of PBT Spec No.IRS/75/2006(Rev - 2) with latest amendments and RDSO Drg.No.SA-23741A Alt.4. | — | — | — | 67,500 | |
| — | 900.00 | — | — | ||
| Fixing of ARA/ Wago screwless terminals and fuse block with provision of holes on hylum sheet and fixing by galvanised nuts & bolts. | — | — | — | 20,475 | |
| — | 900.00 | — | — | ||
| Printed PVC Ferrule FOR CTR / Locatiob Box And Junction Box (Colour coding and Ferrule counting provided by customer) Size: 50mm | — | — | — | 3,600 | |
| — | 50.00 | — | — | ||
| Transferring of Signaling/Telecom cables from existing Location box to New Location box . The work include breaking/ Dismantling o f Existing foundation o f locations, excavating and removing / segregating coils of 2C/6C/12C/19C/24C/30C/Quad cables which may be about 10 mtrs. in length. These cables are to be disconnected and removed from the existing location one by one as per the instruction and under the supervision of Railway staff present at site. The cable is then to be inserted and terminated i n new location box. The item includes neatly dressing o f cable, making wiring tree etc.The material required t o dressing /lacing will b e arrange b y contactor. The work is required to be done systematically and with due precaution during the block or disconnection within the time that may be allowed. The excavation work to be done carefully without damaging the cable to avoid undue failure. (Termination charges will be given separately). Note: Proportionate payment will be made if cable of other length. One No unit = One cable of 10 m length) | — | — | — | 14,650 | |
| — | 1.00 | — | — | ||
| PVC insulated Railway Signaling Indoor Single core wire conforming to IRS 76/89 (Amd3) or latest.Note: - Wire Colours shall be decided by engineer - in - Charge. (1 x 0.6 mm) | — | — | — | 2,712.13 | |
| — | 1.00 | — | — | ||
| Digital low current clamp meter to measure current leaks (parasitic draw down to 1 mA) and electric loads from 1mA to 100 Amp AC/DC, Voltages from 0 to 600V AC/DC, small jaw size to measure current in signalling circuit, 4 digit display. Make -Fluke, GTC/KEW, Scope or superior with better specification as mentioned with all accessories like test lead, batteries and carrying case, sample may be got approved from consignee before supply. | — | — | — | 18,194.34 | |
| — | 1.00 | — | — | ||
| Digital Multimeter of Fluke 287 Industrial, True RMS with temperature, Analog bar graph, Digital display, Backlight, 1000V AC/DC, measure up to 10A, 20A for up to 30 seconds or Superior. | — | — | — | 78,421 | |
| — | 1.00 | — | — | ||
| Supply of Digital Earth Resistance tester three terminal type with LED display, 1999 count, KOICO model 5600 or any reputed make approved by engineer in-charge. | — | — | — | 13,356.84 | |
| — | 1.00 | — | — | ||
| Supply of Digital Insulation Tester 100V/250V/500V range of Model Rish insu 20 Make :RISHABH or MECO or any reputed make approved by engineer in-charge. | — | — | — | 8,240.4 | |
| — | 1.00 | — | — | ||
| Portable Handheld Electronic Labeller with 05 nos. of tape cassette having following or better specifications:1) Print Resolution: 180 dpi,64 dots2) Print Speed: 20mm/sec3) No. of Lines Printable: 2 Lines4) Tape Cassette: 12mm 5) AC Adapter with rechargeable alkaline batteries.6) Accepted make: Brother/Epson/Casio | — | — | — | 46,259.22 | |
| — | 2.00 | — | — | ||
| Diagnostic Terminal :Multi section Portable operator console for on site programming of Axle Counters as per technical requirement | — | — | — | 1,82,802 | |
| — | 1.00 | — | — | ||
| Design of Cable Route Plan submission of Three paper copies for approval. | — | — | — | 9,873 | |
| — | 1.00 | — | — | ||
| Supply of final Cable Route Plan as per laid cable duly measured at every 30m clearly indicating distance of laid cable from fixed point of reference & indicating all track crossings and tail cables in original tracing along with Auto CAD in Pen Drive and Six set copies after approval. | — | — | — | 1,580 | |
| — | 1.00 | — | — | ||
| Design and supply of cable courage plan, location particulars, Cable termination rack particulars, cable meggeringreport, earth resistance particulars, Traction bonding diagram, 1/2 wire count sheet and any other drawing in AutoCAD inA3/A4 size. The contractor shall initially supply 3 sets of circuits complete for approval of Railways. Railways will return one set to the contractor duly approved with alterations/corrections, if any. The contractor shall incorporate Railway's alterations/corrections in the tracings without any deviation and submit all tracings complete in all respects to the Railways along with PENDRIVE & 4 sets of final approved drawings. This includes designing of cable coreage plan based upon I.P in consultation with engineer-in-charge For small/medium yards. LC / IBS / ABS | — | — | — | 19,772 | |
| — | 500.00 | — | — | ||
| Excavation of cable trench as per cable route plan, 1 Mtr. deep and of 0.3 Mtr. to 0.6 Mtr wide advised by Engineer-in-charge alongside the track in normal (all type) soil/strata, conforming to distances as per cable route plan and refilling. This work includes clearing of route from bushes etc., covering of cable laid in trench by loose soil for a layer of 50mm thickness approximately before covering by bricks. The work shall be done as per the extant practice on Western Railway and instructions of Railway Engineer at site. In case 1m depth of trench is not achievable due to site conditions, specific approval of JA grade officer will be required for each site where trench depth of 1m is not possible. Without the approval of JA Grade officer, no payment for trenching will be made for trench depth less than 1m. | — | — | — | 4,19,500 | |
| — | 50.00 | — | — | ||
| Digging of cable trench 0.3 Mtr. Deep and 0.3 Mtr. Wide on Asphalted Platform / Road / Hard rocky area. Refilling with earth leveling of trenches & restoring the original surface of trenches. | — | — | — | 25,638 | |
| — | 50.00 | — | — | ||
| Digging of trench 1.2 M deep from rail flange/ road level and, 0.3 Mtr to 0.6 Mtr wide and back filling after placing of DWC/ RCC/GI pipe. (Placing of DWC/RCC/GI pipe covered separately).The ballast disturbed be screened and dressed as required by Engineer-in-charge or his representatives and road tarred immediately. For track crossing, Drg. No. CSTE/3644 Pg.7 of 11 and for Road Crossing, Drg. No. CSTE/3644 Pg. 5 of 11 are to be followed. | — | — | — | 43,696.5 | |
| — | 200.00 | — | — | ||
| Horizontal direction drilling/boring without damage of surface road using Auger Machine. The bore shall be 150 mm Dia & shall be done at the depth of minimum 1200 mm from the ground level. The ground level shall be considered ignoring the bank height of the bank of the road. The length of the bore shall be minimum 4 Mtr long. The HDD with or without HDPE pipe as per direction of Engineer In charge. Note: HDPE pipe supply is taken as separate item. This item also includes cable laying (HDD boring). | — | — | — | 2,37,570 | |
| — | 200.00 | — | — | ||
| High density polyethylene pipes (HDPE) of 110 mm/125 mm outer Dia, 10 mm wall thickness, along with one coupler for every 6 Mtr. As per spec. No. Is 4984:2016 with latest amendments and material grade: PE 80. | — | — | — | 1,40,200 | |
| — | 1000.00 | — | — | ||
| Laying of S&T Cables of various cores/ pairs/ quads in trenches/ GI pipes/ RCC pipes/ DWC pipes/ Trucking. This also includes laying of cables in track crossings & road crossings. Item includes provision of labels of colored plastic adhesive tapes or any other identifiable material on each cable to give the cable number at each G.P.(Cables will be daggered before and after its laying by contractor under supervision of Railway Representative and he will submit the meggering report of each testing). Length of the cable laid includes the length of the cable coiled for termination purposes. | — | — | — | 9,370 | |
| — | 1000.00 | — | — | ||
| Half Round RCC pipes & collars of 150 mm internal dia (1 meter long) along with collars as per IS No. 458/2003 of NP type. Tenderer shall submit inspection/test report before supply for priorapproval by Engineer in charge. | — | — | — | 1,58,980 | |
| — | 400.00 | — | — | ||
| Supply and fixing of polyolefin cable channel (Injection Moulded Plastic cable Duct) of size width 100/200 mm, height 155/230 internal/external, length 1 meter produced of polyolefin with fire, protection class K-1 in accordance with DIN 53438 part all for laying signaling/telecom cables, channel attachable to each other with male female swallowtail connectors and having suitable detachable cover including supply of all fixing materials like Brackets,etc. , as per RDSO STS/E/cable laying Precise Vol-IV and as per technical specifications. | — | — | — | 6,35,600 | |
| — | 10.00 | — | — | ||
| Double Walled Corrugated (DWC) HDPEPipe with associated collars etc. as perRDSO Specification No.RDSO/SPN/204/2011 or latest anti-rodent& anti-oxidant and non-flame propagatingtype in 6 meters straight length and ofsize 120 mm outer die,& 103.5 mm innerdia. . One of the following couplingarrangements should also be suppliedwith each pipe as per the siterequirement. 1) Suitable snap fit couplerwith rubber 'O-Ring 2) Spacers 3) Tees 4)Bend, 5) End- cap (The total quantity ofabove items is equal to no. of pipessupplied.) DWC pipe shall be marked atevery 1 mtr length in such a way thatmanufacturer's name, vender name andyear of manufacture can be easily identified. Color-Bright Orange; TestCheck by Consignee & Sample check byJAG officer. | — | — | — | 19,122 | |
| — | 50.00 | — | — | ||
| Medium Class G.I. Pipes to IS: 1239 (Pt.)-2004 or latest; 100mm dia. (int. Dia) 3.65 mm thick or above with coupling. G.I. pipes shall have ISI mark on it and contractor should submit manufacturer's test certificate of G.I. pipes. | — | — | — | 58,514 | |
| — | 1000.00 | — | — | ||
| Transportation and Placing of DWC/RCC pipes along with collars in trenches at places of track and road crossings, platform cuttings etc. also for straight cable laying. (Cable laying is covered separately.) | — | — | — | 33,220 | |
| — | 10.00 | — | — | ||
| Supply and installation of RCC cable route marker engraved and painted on both side along the route every 50mm and route diversion as per Drg. No 4014/00/CC4 or latest/ Stone marker | — | — | — | 4,126.6 | |
| — | 10.00 | — | — | ||
| Miniature 'E' type lock complete with keys as per RDSO Drg. No. SA 3473, 3373 & spec. IRS(S) 30/64. Ward to be specified by Engineer - in - charge. | — | — | — | 20,815.2 | |
| — | 50.00 | — | — | ||
| Laying and fixing of Medium class GI pipes 100 mm Dia (4.5 mm thickness) as per IS 1239 ( Part 1) 2004 or latest with coupling on culverts/bridges, perforated at a distance of 20 cm or less with 10 mm Dia hole, or at any other locations as decided by Site Engineer. The GI pipe is to be filled with chattered compound. It includes supply of all material required for fi Xing arrangement. Contractor will also supply flexible/corrugated HDPE pipe at the end of GI pipe to protect the cables from sharp edges and sudden bends. The e laying and fi Xing to be done as per RDSO drawings No. SDO/cable laying/011 and SDO/cable laying/012, issued vide RDSO document No. RDSO/SI/G/2010 Version 1.1 dated 04.02.2014, or latest. | — | — | — | 20,903.5 | |
| — | 40.00 | — | — | ||
| Heavy Duty Slotted Angle Size (50mm x 50mm x 3.15mm thickness), Length 2440 mm (8 ft.) with 20nos M.S. Hex head bolt with suitable nut, with 02nos plain washer & one no. spring washer. Size of bolt- M8 x 30mm long property class-4.6 as per IS-1363 full set duly galvanized. | — | — | — | 7,320 | |
| — | 4.00 | — | — | ||
| Maintenance Free Earth Electrode of length 3m, including supply o f 3 bags o f Earth enhancement material for earthling (10KGs/bag) for each electrode & other accessories as per Drg. No. SDO / RDSO/ E&B/001 and RDSO Spec No. RDSO / SPN/197/2008. This item includes the following items: (a) Copper bonded steel earth electrode o f 3.0 meter long & 17.2 m m dia with Cu-bonding thickness of min 250 micron - 1 no. (b) Earth-enhancing compound (10 Kg/Bag) - 3 No. (c) Cu-strip 200 X 25 X 6 mm to terminate earth rod = 1no. (d) Cu-strip 300 X 25 X 6 mm (MEEB) = 1 no. (e) Cu- strip 150 X 25 X 6 mm (SEEB) = 1 no. (Inspection by RDSO) | — | — | — | 41,612.32 | |
| — | 4.00 | — | — |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
TD-71-132Deposit.pdf
ATTACHMENT
TD-71-132Deposit.pdf
CORRIGENDUM
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].