Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.5 LAccepted-AOC | L1 | Accepted-AOC The lowest e-tenderer | |
| 2 | L2₹14.6 L+₹2.7 L (22.8%)Rejected-Finance 1001 B BHAVESHWAR BLDG NO 03 BHAVESHWAR LANE GHATKOPAR EAST MUMBAI 400077 | MUMBAI SUBURBAN | MAHARASHTRA | 400077 | L2 | Rejected-Finance Not Meeting eligibility criteria | |
| 3 | L3₹19.2 L+₹7.3 L (62.0%)Rejected-Finance NAGPADA MUMBAI 10TH LANE KAMATHIPURA S P ROAD TELANG BLDG NO 23 ROOM NO 5 10TH LANE MUMBAI 400008 | MUMBAI | MUMBAI | MAHARASHTRA | 400008 | L3 | Rejected-Finance Not Meeting eligibility criteria |
Tender Value
₹14 L
EMD Value
₹28,000
Closing Date
10 Apr 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Shri T Rajasekharam, IDSE, SE (SAG)
Headquarters Commander Works Engineer (Army) 24 Assaye Building, Colaba Mumbai-400 005
REPAIR RENEWAL HT RINGMAIN SYSTEM AND VCBS UNDER GE N SANTACRUZ MUMBAI
2024_MES_646599_1
85116/N/E8
Open Tender
Civil Works
Item Rate
120 days
Garrison Engineer (N) Santacruz
please ref tender documents
7 documents required · 7 mandatory
₹500
Garrison Engineer (N) Santacruz
₹28,000
3 Jun 2024
15 Mar 2024
11 Apr 2024
15 Mar 2024
10 Apr 2024
29 Mar 2024
15 Mar 2024 - 3 Apr 2024
Amount
M&L for carrying out Lab test for ACIDITY of transformer oil for various transformers installed at sevoke road military station complex from State Electricity board approved laboratory and submission of test reports on the proper format as specified and directed.
M & L for dehydration of transformer oil through on load mobile stream line transformer oil filtration plant at site with all accessories connected to transformer and carryinjg out filtration of oil for desired dielectric strength ie not less than 45 KA at 4 mm gap.
Serving of of Ringmain unit of any make of rating 11 KV, upto 400 Amps dismantling / opening of the VCB for servicing / overhauling, taking out and removing unserviceable/defective parts including cleaning & servicing ,greasing, oiling of the parts etc and replacement of unserviceable parts with new one, reassembling the VCB after overhauling / servicing and Calibration and testing of 11KV VCBs indoor type alongwith control panel and control wiring, protection system and relays by injection system in primary / secondary side complete all as specified and directed by Engineer-in-Charge. (Note :- The quoted rates of the contractor includes for fixing the serviceable parts in position and replacement of unserviceable minor spare parts .
Disconnection of both HT and LT connection from cable end box, taking down the disconnected transformer(Outdoor type) from platform,and transportation of unserviceable transformer complete unit to workshop including loading/unloading of capacity 315KVA, 11/0.433 KV. (a) Disconnecting and taking down faulty / defective copper wound transformer , opening the top cover, draining out unserviceable insulation oil and carrying out the following work :- (b) Complete Rewinding of HT / LT leg coil complete using copper wire of appropriate gauge, size and turn as existing with double paper coated insulation including all requisite insulating materials like packing sleeves, separator, tapes etc. as specified and existing, heating, varnishing the core and winding assembly after framing up top and bottom steel structure of transformer all as specified and directed. ( HT / LT Leg coils copper wound shall be measured and paid separately under relevant item of Sch ‘A’ here-in-after). (c) Replacement of all insulating materials other than incorporated for rewinding of LT/HT coils as existing . (d) Fixing of HT porcelain bushing with studs, nuts, washers 3 Nos and LT porcelain bushing with studs, nuts and washers 4 Nos and connection with primary and secondary winding main terminals all as directed and specified. ( HT/LT bush with stud, nuts, washers shall be measured and paid separately under relevant item of Sch’A’ here-in-after) (e) Fixing only existing serviceable accessories as obtained from Ser No 4(a) after proper cleaning, minor repair etc all as required and directed (f) Replacement of all gasket materials in top cover, HT, LT bushing using rubberized gasket sheet 4.0/6.0 mm thick duly pasted with gasket cement. (g) Replacement of unserviceable bolts, fixing of existing serviceable bolts, nuts, washers of different size and tightening properly. (h) Repositioning of core and winding assembly inside the tank, assembling the complete unit and filling of transformer oil and subsequent testing complete all as directed. (j) Type Tests as per clouse 16.1.1 and routine test as per clouse 16.1.2 of IS-2026 (Part I)-1977. are to be carried out at manufacturer work shop all as directed. (j) Shifting the transformer from its original side to manufacturer work shop and retunbach after repair including reconnection of HT/LT cables and including subsequent testing complete all as directed. (k) Rewing works to be carried out in any reputed transformer manufacturer work shop and type test & routine test are to be done at said work shop as directedby Eng-in-charge as per IS provisions stated above. Note:- HT / LT Leg coils and transformer oil shall be measured and paid separately under relevant item of Sch ‘A’ here-in-after
Supply only LT leg coil of copper conductor/ strips for transformer of capacity up to 300 KVA complete with insulation, varnishing by vacuum impregnation and baking of coil assembly, etc. complete all as specified & directed by the EIC .
Supply only HT leg coil of copper conductor for transformer of capacity up to 300 KVA complete with insulation, varnishing by vacuum impregnation and baking of coil assembly, etc. complete all as specified & directed by the EIC
Disconnecting the transformer( plinth / pole mounted / outdoor/indoor 11 KV/433 volts) from HT/LT system and opening carefully by draining out the transformer oil for stopping the leakages by replacing the unserviceable spare parts of capacity 250 KVA to750 KVA including refilling the transformer oil and reassembling after repairs and ensuring no leakages, loose connection on HT/LT & charged the system. (a) Replacing LT bushing and gasket with brass/copper studs, washer & Rubber bush etc for 250 TO 750 KVA
(b) Replacing 11 KV HT bushing & brass/copper studs, gasket with-250 to 750 KVA
(c) Transformer Gaskets and seals made from a blend of nitrile rubber and cork complete for capacity250KVA to 750KVA transformer.
M&L for replacement of breather assembly transparent MS body with top and bottom portion pressed with metallic cover, filled with silica gel blue in colour and suitable for fixing on existing pipe of size 15/20/25 mm dia as per site requirement/ capacity of Transformer up to 250 KVA to 750 KVA
Material & labour for replacing the silica gel in the transformer breather of various capacity.
M & L for disconnecting the HT & LT supply of capacity 250 to 750 KVA 11KV/ 0.433 KV transformer, draining out complete insulating oil from transformer kept on plinth including removing transformer top cover, explosion vent pipe and lifting the core from the shell/ tank , wash/ cleaning the core winding, internal surface of shell container with clean dry oil by flushing out by means of pump set, removing complete composite sludge through drain valve. Reassembling top cover with conservator and explosion vent pipe, change of gasket for the top plate, cleaning oil level indicator and tightening all bolts and nuts & refilling new transformer oil through stream line filer to a required level with out any oil leakage, test & commissioning.
Disconnecting & taking out non functional indoor VCB of any description and any make of rating 11 KV, upto 400 Amps dismantling / opening of the VCB for servicing / overhauling, taking out and removing unserviceable/defective parts including cleaning & servicing ,greasing, oiling of the parts etc and replacement of unserviceable parts with new one, reassembling the VCB after overhauling / servicing and Calibration and testing of relays of VCBs indoor type alongwith control panel and control wiring, protection system and relays by injection system in primary / secondary side complete all as specified and directed by Engineer-in-Charge. (Note :- The quoted rates of the contractor includes for fixing the serviceable parts in position and replacement of unserviceable parts with new parts. The new replaced parts shall be measured and paid for separately under appropriate item of Sch `A’ as `supply only ‘)
Supply only following spare parts for 11 KV VCB, upto 400 Amps capacity indoor type . (a) Big gear for closing spring charge
(b) Small gear for closing spring charge
(c) Closing / triping coil assy of 11 KV VCB's type VE -12, 30 volts matching with the existing system complete.
(d) Spring charging motor& gear assy of 230 volts 0.25 HP, 8000 RPM of 11 KV VCB's type VE -12, 30 volts matching with the existing VCB system complete.
(e) Supply & fix PT 11 KV / 110Volt 3 phase Potencial transformer HT panel mounted, push fit with necessary fuses complete all as spd and directed.
(f) CT resin cast single phase 11 KV of ratio 30/5 Amps with suitable burden, conforming to IS 3156/1992, frequency 50 Hz , single phase, suitable VA burden and class-I accuracy for protection and metering equipments. matching with the existing VCB system complete.
(g) Indicator lamp LED type of different colour as per existing, 60 mm dia 30 volts incl taking down old unsv ones complete.
(h) One number panel mounted multi function trivector meter having the functions like voltage,current, active power, reactive power, power factor, time,frequency, RS-232 interfarance and provision direct comunication port etc .
(j) Explosion vent diaphragm suitable size as per sample
Supply & fix in repairs gate valve (Gun metal), ISI marked of size 25mm.
Supply for TOP Up ( topping) insulating oil for transformer conforming to IS-3356 at different Transformers & different locations.
Earthing complete with GI earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (Earth pit not less then 2.25m deep below ground level ) with top edge not less than 1.5m below ground level connected to GI earth strip 32 x6 mm by means of GI bolts,nuts, check nuts,washers & GI strip ,protected by 50 mm bore medium grade GI pipe up to 7,5mtr distace including necessary charcol, salt & 20Kg Benzonite powder Funnel with wire mesh , watering pipe20mm dia medium grade excavation earth work PCC (1:3:6) type C-1 earth chamber , 50mm thick RCC cover with 6mm nominal reinforcement etc complete all as shown electrical plate No. 5 of MES schedule part I all as specified and directed . .
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr depth and getting out in Hard / dense soil including forming bottom surface etc.for taking up existing unserviceable U/G cable and for laying new XLPE U/G cable.
Returning, filling in including spreading, levelling , and well ramming in layers not exceeding 25 cm thick complete.
Removing excavated material not exceeding 50 mtr and depositing where directed at a level not exceeding 50 mtr above the starting point.
Material and labour for crushed sand filling in trenches for cable crushioning below and above the cable complete all as directed by Eng- in -charge.
Supply & laying un -inforced precastconcrete with flat cover Factory made Class HV, type 1, size 300x180x40 mm complete .
Supply & laying un -inforced precastconcrete cable cover LV type flat size 250x150x40 mm complete .
Supply, laying & testing XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) with stranded aluminum conductor, 11000 volts grade, of size 120 sqmm, 3 core incl taking down unsv one complete.
Supply, laying & testing XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) with stranded aluminum conductor, 1100 volts grade, of size 150 sqmm, 3 core incl taking down unsv LT cable complete.
S&F Cable jointing Kit for 11KV (E) grade cable for indoor cable End termination cold shrink type joint complete with jointing material and accessories suitable for 11 KV(E) XLPE cable of size 3 core 95 sq mm with aluminium conductor
S&F microprocessor based electronic relay type IRI-PRO-V3-3I-EI complete including taking out old unsv defective/old vintage/obsolete model of relays from 11 KV VCBs including necessary additions/ alterations of VCB front panel including cutting welding of front size panel board/ position including necessary touch up to the panel board/ position including necessary touch up to the panel board all as complete and testing all as specified and directed.
Repairs to 30v fully automatic charger cum auxillary power supply unit suitable for VRLA batteries with constant voltage and constant current features input voltage 415V AC, output voltage 30V DC digital microprocessor type bost back battery charging unit three phase 415 v input and output 30v DC with and including 2 Nos of 12V , 65 AH maint free battery (complete for backup to relays and other protection system complete with replacement of following parts a. Replacement of bost back transformer unit-01 Nos b. Replacement of logic circuit unit-01 No c. Replacement of battery 12V 65 AH Model-Exide power safe-02 Nos
EVEREST POWER CONTROL ENGINEERS
SHREE SHIV ELECTRICAL
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .