Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.7 LAccepted-AOC ROOM NO 145 MASJID WALI GALLI GANESH MURTI NAGAR PART NO 2 COLABA MUMBAI 05 | L1 | Accepted-AOC Being Lowest Tenderer | |
| 2 | L2₹36.7 L+₹75,300 (2.09%)Rejected-Finance | L2 | Rejected-Finance Being Other than Lowest Tenderer | |
| 3 | L3₹38.8 L+₹2.8 L (7.92%)Rejected-Finance ROOM NO D 297 PART III GANESH MURTI NAGAR CUFF PARADE ROAD COLABA MUMBAI 400005 | MUMBAI | MAHARASHTRA | 400005 | L3 | Rejected-Finance Being Other than Lowest Tenderer | |
| 4 | L4₹39.9 L+₹3.9 L (10.9%)Rejected-Finance FLAT NO 301 PEARL APARTMENT PLOT NO 121 SECTOR 8A AIROLI NAVI MUMBAI 400708 | NAVI MUMBAI | THANE | MAHARASHTRA | 400708 | L4 | Rejected-Finance Being Other than Lowest Tenderer | |
| 5 | L5₹44.2 L+₹8.2 L (22.9%)Rejected-Finance | L5 | Rejected-Finance Being Other than Lowest Tenderer |
| Sl No | Description | Qty | Unit | Chakshu Enterprise L6 | ENJOY L8 | somnath engineering corporation L9 | R J ENTERPRISES L4 | sapana enterprises L7 | Shree Ayyappa Engineering L11 | cooltech engineering services L10 | BRITE INDUSTRIES L2 | GANGAJAL L3 | shree siddhivinayak engineers L5 | CHOUDHARY ELECTRICAL L1 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00Repairs/ Routine monthly basic maintenance of VRF plants of Toshiba/Carrier/Blue Star make of capacity ranging from 12 - 24HP having various outdoor units of following capacity including maintaining the plants for desired temperature of 21+/-3 degree celcius without interuption including repairs/ replacement of damaged/ unserviceable minor parts, controlling valves, copper tubings, nitrile rubber insulation, and all electrical/ electronics components, control wirings, sensors,Thermistors, thermocol inner packs,indoor/ outdoor fan motor windings, vibration pads, painting of rusted out door stands and connected accessories, drainage lines, pre filters control/ communication wirings,earthings, leak test and all other accessories not mentioned in this schedule complete all as specified and directed by Engineer-in-Charge. | ||||||||||||||
| 1.01 | Out door unit of capacity 07 HP -3 Nos. | 33 | Each job | 1,120 ₹36,960 | 1,260 ₹41,580 | 1,300 ₹42,900 | 900 ₹29,700 | 1,172 ₹38,676 | 1,309 ₹43,197 | 1,310 ₹43,230 | 500 ₹16,500 Lowest | 4,700 ₹1,55,100 | 2,500 ₹82,500 | 1,000 ₹33,000 |
| 1.02 | Out door unit of capacity 14 HP - 2 Nos. | 22 | Each job | 1,380 ₹30,360 | 1,550 ₹34,100 | 1,590 ₹34,980 | 1,100 ₹24,200 | 1,443 ₹31,746 | 1,614 ₹35,508 | 1,610 ₹35,420 | 500 ₹11,000 Lowest | 4,847 ₹1,06,634 | 2,700 ₹59,400 | 1,100 ₹24,200 |
| 1.03 | Out door unit of capacity 16 HP - 4 Nos. | 44 | Each job | 1,740 ₹76,560 | 1,965 ₹86,460 | 2,000 ₹88,000 | 1,400 ₹61,600 | 1,825 ₹80,300 | 2,035 ₹89,540 | 2,040 ₹89,760 | 500 ₹22,000 Lowest | 5,100 ₹2,24,400 | 3,000 ₹1,32,000 | 3,000 ₹1,32,000 |
| 1.04 | Out door unit of capacity 18 HP - 04 Nos. | 44 | Each job | 2,050 ₹90,200 | 2,310 ₹1,01,640 | 2,375 ₹1,04,500 | 1,650 ₹72,600 | 2,150 ₹94,600 | 2,405 ₹1,05,820 | 2,425 ₹1,06,700 | 500 ₹22,000 Lowest | 5,247 ₹2,30,868 | 3,200 ₹1,40,800 | 3,100 ₹1,36,400 |
| 1.05 | Out door unit of capacity 20 HP - 01 Nos. | 11 | Each job | 2,250 ₹24,750 | 2,530 ₹27,830 | 2,605 ₹28,655 | 1,810 ₹19,910 | 2,350 ₹25,850 | 2,642 ₹29,062 | 2,610 ₹28,710 | 500 ₹5,500 Lowest | 6,847 ₹75,317 | 3,300 ₹36,300 | 3,000 ₹33,000 |
| 1.06 | Out door unit of capacity 22 HP - 02 Nos. | 22 | Each job | 3,850 ₹84,700 | 4,330 ₹95,260 | 4,460 ₹98,120 | 3,100 ₹68,200 | 4,032 ₹88,704 | 4,505 ₹99,110 | 4,500 ₹99,000 | 500 ₹11,000 Lowest | 7,777 ₹1,71,094 | 3,500 ₹77,000 | 3,200 ₹70,400 |
| 1.07 | Out door unit of capacity 24 HP - 01 Nos. | 11 | Each job | 3,350 ₹36,850 | 3,770 ₹41,470 | 3,870 ₹42,570 | 2,700 ₹29,700 | 3,512 ₹38,632 | 3,925 ₹43,175 | 3,910 ₹43,010 | 500 ₹5,500 Lowest | 10,847 ₹1,19,317 | 3,600 ₹39,600 | 3,300 ₹36,300 |
| 1.08 | Four way casette type indoor Unit of any capacity -35 Nos. | 385 | Each job | 165 ₹63,525 | 185 ₹71,225 | 190 ₹73,150 | 134 ₹51,590 | 173 ₹66,605 | 191 ₹73,535 | 190 ₹73,150 | 100 ₹38,500 Lowest | 1,111 ₹4,27,735 | 1,100 ₹4,23,500 | 800 ₹3,08,000 |
| 1.09 | Split hi wall type indoor unit of any capacity -65 Nos . | 715 | Each job | 100 ₹71,500 | 115 ₹82,225 | 120 ₹85,800 | 98 ₹70,070 Lowest | 104 ₹74,360 | 120 ₹85,800 | 135 ₹96,525 | 100 ₹71,500 | 647 ₹4,62,605 | 500 ₹3,57,500 | 300 ₹2,14,500 |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
5 Feb 2026, 6:55 pmClosed
LT COL ANIL KUMAR S
GARRISON ENGINEER NW KUNJALI DR HOMI BHABHA ROAD NAVY NAGAR COLABA MUMBAI 400005
8262 REPAIR/ ROUTINE MAINTENANCE OF VARIOUS CAPACITY VRF SYSTEMS AND CONNECTED ITEMS AT NAVAL DOCKYARD UNDER GE (NW) KUNJALI
2026_MES_748911_1
8262/E8
Open Tender
Civil Works
Item Rate
183 days
GE (NW) KUNJALI
ALL AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
Yes
GE (NW) KUNJALI
₹98,000
Yes
18 Mar 2026
17 Jan 2026
7 Feb 2026
23 Jan 2026
5 Feb 2026
30 Jan 2026
17 Jan 2026 - 23 Jan 2026
Repairs/ Routine monthly basic maintenance of VRF plants of Toshiba/Carrier/Blue Star make of capacity ranging from 12 - 24HP having various outdoor units of following capacity including maintaining the plants for desired temperature of 21+/-3 degree celcius without interuption including repairs/ replacement of damaged/ unserviceable minor parts, controlling valves, copper tubings, nitrile rubber insulation, and all electrical/ electronics components, control wirings, sensors,Thermistors, thermocol inner packs,indoor/ outdoor fan motor windings, vibration pads, painting of rusted out door stands and connected accessories, drainage lines, pre filters control/ communication wirings,earthings, leak test and all other accessories not mentioned in this schedule complete all as specified and directed by Engineer-in-Charge.
Out door unit of capacity 07 HP -3 Nos.
Out door unit of capacity 14 HP - 2 Nos.
Out door unit of capacity 16 HP - 4 Nos.
Out door unit of capacity 18 HP - 04 Nos.
Out door unit of capacity 20 HP - 01 Nos.
Out door unit of capacity 22 HP - 02 Nos.
Out door unit of capacity 24 HP - 01 Nos.
Four way casette type indoor Unit of any capacity -35 Nos.
Split hi wall type indoor unit of any capacity -65 Nos .
(a) AC mechanic skilled (duly trained in one No) have to attend complaint for all the VRF units mentioned above in General shift or as and when required basis and shall report to the JE concerned for receiving the complaints. AC Mechanic will be responsible to rectify the minor faults, routine cleaning and dry servicing of plant & filters. Any number of helper required for his assistance will be provided by Contractor and for the same rates are deemed to be included in above quoted rates. (b) The cost of replacement of all Minor parts which are not mentioned in schedule shall deemed to be included in above quoted rates. (c) Contractor shall submit ID proof, police verification, Residential proof, Bank A/C details to department and obtain approval of Engr-in-charge before employing a person as AC Mechanic. (d) AC Mechanic must be experienced in VRF AC Plant & capable to carry out any type of maintenance required for smooth functioning of above mentioned Plants. (e) In case of any major breakdown the additional manpower if required shall be arranged by contractor and for the same rates are deemed to be included in above quoted rates. Any type of breakdown shall be attended within 24 hrs & get rectified in 72 hrs else a penalty of ₹. 1500/- per day shall be imposed.
Supply and charging of Refrigerant fresh gas R 410 complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement Compressor for Out door units according to the existing cat pt no. of VRF 18 to 16 HP Unit including testing complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement Control Board for Out door units according to the existing cat pt no. of VRF 18 to 16 HP Unit including testing complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement MNET Board, for Out door units according to the existing cat pt no. of VRF 18 to 16 HP Unit including testing complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement Noise filter for Out door units according to the existing cat pt no. of VRF 18 to 16 HP Unit including testing complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement Fan board for Out door units according to the existing cat pt no. of VRF 18 to 16 HP Unit including testing complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement Invertor board, for Out door units according to the existing cat pt no. of VRF 18 to 16 HP Unit including testing complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement Motor for Out door units according to the existing cat pt no. of VRF 18 to 16 HP Unit including testing complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement Compressor for Out door units according to the existing cat pt no. of VRF 14 to 10 HP Unit including testing complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement Control Board , for Out door units according to the existing cat pt no. of VRF 14 to 10 HP Unit including testing complete all as specified and directed.
Supply and fix in replacement MNET Board, for Out door units according to the existing cat pt no. of VRF 14 to 10 HP Unit including testing complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement Noise filter for Out door units according to the existing cat pt no. of VRF 14 to 10 HP Unit including testing complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement Fan board for Out door units according to the existing cat pt no. of VRF 14 to 10 HP Unit including testing complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement Invertor board, for Out door units according to the existing cat pt no. of VRF 14 to 10 HP Unit including testing complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement Motor YC9201A, for Out door units according to the existing cat pt no. of VRF 14 to 10 HP Unit including testing complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement Compressor for Out door units according to the existing cat pt no. of VRF 7 to 12 HP Unit including testing complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement Control Board , for Out door units according to the existing cat pt no. of VRF 7 to 12 HP Unit including testing complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement MNET Board, for Out door units according to the existing cat pt no. of VRF 7 to 12 HP Unit including testing complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement Noise filter for Out door units according to the existing cat pt no. of VRF 7 to 12 HP Unit including testing complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement Fan board for Out door units according to the existing cat pt no. of VRF 7 to 12 HP Unit including testing complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement Invertor board, for Out door units according to the existing cat pt no. of VRF 7 to 12 HP Unit including testing complete all as specified and directed by Engineer-in-Charge.
Supply and fix Motor in replacement for Out door units according to the existing cat pt no. of VRF 7 to 12 HP Unit including testing complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement PCB for four way casette/hiwall type indoor units of VRF Unit including testing complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement Drain Pump for four way casette/hiwall type indoor units of VRF Unit including testing complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement Blower motor for four way casette/hiwall type indoor units of VRF Unit including testing complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement Linear expansion Valve for four way casette/hiwall type indoor units of VRF Unit including testing complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement Addressing board for four way casette/hiwall type indoor units of VRF Unit including testing complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement Remote Controller for four way casette/hiwall type indoor units of VRF Unit including testing complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement perforated cable tray of size 300mm x 50mm and 2.0mm thick painted powder coated pre galvanised hot dipped complete all as specified and taking out old u/s damaged cable tray complete all as specified and directed by Engineer-in-Charge.
Taking down including Supply installation, testing & commissioning of mirror finish inside /outside refrigerant piping 25 to 42mm dia including thermal insulation out of hard drawn copper pipes suitable for VRV system including all fittings like bends elbows, tees with all internal joints type fittings pipe line must be tested for requisite pressure and must be supported at every 2.4mtrs in intervals. All refrigerant piping to be insulated with 19/13mm class "0" armaflex nitrile rubber complete refrigerant piping to be laid in GI tray and taking out old u/s damaged refrigerant Pipe all as specified and as directed by Engineer-in-Charge.
All as per item No 31.00 but 6.5mm to 16mm dia
Supply and fixing in replacement condenser coil for outdoor unit of VRF capacity 7 HP including leak testing by Nitrogen complete all as specified and directed by Engr-in-Charge”
All as per item No 33 above but capacity 10 HP
All as per item No 33 above but capacity 12 HP
All as per item No 33 above but capacity 14 HP
All as per item No 33 above but capacity 16 HP
All as per item No 33 above but capacity 18 HP
Supply and fixing in replacement cooling/Evaporator coil for four way/Hi-wall indoor unit of capacity 1.7/1.8 TR including testing complete all as specified and directed by Engr-in-Charge.
All as per item No 34 above but 2.8 TR
All as per item No 34 above but 3.2 TR
All as per item No 34 above but 3.9 TR
Supply and fixing in replacement Mother board for four way Cassette/HI-wall type indoor units of VRF Unit including testing complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of various type of sensors for four way Cassette/Hi-wall type indoor/outdoor units of VRF Unit including testing complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of Communication cable of size 1.5 sqmm 3 core non polarity cable with end termination between indoor to outdoor units, communication cbling between the individual controlers to the main central controller with suitable size PVC conduit incl accessories etc complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement solenoid valve for four way Cassette/Hi-wall type indoor units of VRF including testing complete all as specified and directed by Engr-in-Charge.
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.27 MB
8262TENDERDOCUMENTS.pdf
Tender Documents • 1.34 MB
BOQ_838699.xls
BOQ • 11.47 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .