Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.7 LAccepted-AOC | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹28.8 L+₹75,986 (2.71%)Rejected-Finance | L2 | Rejected-Finance Being Not Lowest | |
| 3 | L3₹29.4 L+₹1.4 L (4.89%)Rejected-Finance | L3 | Rejected-Finance Being Not Lowest | |
| 4 | L4₹29.9 L+₹1.9 L (6.77%)Rejected-Finance SECUNDERABAD | WARANGAL | TELANGANA | 506350 | L4 | Rejected-Finance Being Not Lowest | |
| 5 | L5₹30.4 L+₹2.4 L (8.51%)Rejected-Finance | L5 | Rejected-Finance Being Not Lowest |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
2 Nov 2021, 6:00 pmClosed
GE MCEME SECUNDERABAD
GE MCEME Secunderabad MCEME Campus, Trimulgherry (Post) Secunderabad - 500 015
SPECIAL REPAIRS TO 08X WASHROOMS IN BUILDING NO P21 OF CTW AT MCEME UNDER GE MCEME SECUNDERABAD
2021_MES_479977_1
GE/MCEME/TOK/32 OF 2021-22
Open Tender
Civil Works
Item Rate
180 days
SECUNDERABAD
Class E Category a(I)
8 documents required · 8 mandatory
₹500
GE MCEME SECUNDERABAD
₹50,000
Yes
15 Dec 2021
6 Oct 2021
5 Nov 2021
6 Oct 2021
2 Nov 2021
20 Oct 2021
Amount
Taking down plastering in cement mortar on brick or stone wall etc including racking out joints hacking for key scrubbing down with water etc. complete all as specified and directed.
M&L for cement mortar plaster 1:3, on fair faces of brick/concrete surfaces 5 mm thick incl finishing even and smooth without using extra cement on ceiling complete all as specified and directed.
M&L for rendering 15 mm thick on concrete surfaces of walls in CM 1:6 finished even smooth without using extra cement complete all as specified and directed.
M&L for Preparation of new plastered surfaces of ceiling and cornices, and applying two coats of oil emulsion distemper (OBD) complete all as specified and directed.
M&L for Preparation of old decorated surfaces of ceiling and cornices, spoiled by smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots by scraping and applying two coats of oil emulsion distemper (OBD) complete all as specified and directed.
M&L for application of high build polymer modified cement mortar (1:2.5) mixed with 3 kg SBR per bag of cement in ceiling surfaces 10 to 20mm thick in two layers surfaces over a coat of bonding agent Nito Bond SBR (1 Ltr SBR + 1 Ltr) water + 3 kg cement), complete all as specified and as directed by Engineer -in-Charge.
M&L for applying two coats of OBD over a coat of primer over 2 to 3 mm wall care putty finish including preparing the new plastered wall surfaces complete all as directed by Engr-in-charge
M&L for complete removal of existing wall surfaces and applying two coats of oil bound distemper over a coat of alkali resisitant primer and one coat ( 2mm thick) wall care putty complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutter from the frames ) not exceeding 1.5 Sqm each complete all as apecified
M&L Solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M S Square tube, supplying and fixing in opening as per manufacturers instructions all as directed complete all as specified
M&L Factory made solid panel laminated PVC door shutter 30mm thick (style) consisting of frame made out M.S tube for top & bottom rails. M.S Frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width struck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail : Panelling of plain colour PVC sheet to be fitted in the M.S frame welded/scaled the stiles & rails with suitalble PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specifications & drawing complete all as specified and directed.
S&F 100 mm long S/S butt hinges medium weight cold rolled and mild steel hinge pin complete all as specified and directed.
S&F 250 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified and directed.
S&F extruded aluminium anodised handle 125 mm fabricated type polished and fixed complete all as specified and directed.
M&L for 200 mm Aluminium anodised barrel tower bolts of extruded section rolled complete all as specified and directed.
S&F Aluminium ( Die cast ) body Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed and all as specified and directed by Engineer in charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing srviceable tiles to store and rubbish off the premises complete all as apecified
M&L for coloured Non Skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
M&L for 15 mm thick screed bed or bedding layer of mortar in cement mortar 1:6 for lying floor finishes complete all as specified and directed.
M&L for rendering 10mm thick in cement mortar 1:4 finished rough to receive wall tiles etc. complete all as specified and directed.
M&L for coloured Glazed ceramic tiles 450X 300X 7mm thick on vertical surfaces such as dados, set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified an directed.
Demoltion of cement Concrete of any description and in any position not otherwise specifically provided complete all as specified and as directed by Engr-in-Charge.
M & L Rendering 15mm thick in CM (1:3) on sunken concrete floor surfaces mixed with integral water proofing compound finished even & smooth without using extra cement. Note : WPC shall be measured & paid separately complete all as specified and directed.
M & L for PCC 1:4:8 type D2 using 40mm using graded stone aggregate as in foundations, filling in sunken portions and mass concrete complete all as directed by Engr-in-charge.
M&L for 25mm thick PCC 1:2:4 type B1 using 20mm graded stone aggregate as in (sunken floors/ WC area ) complete all as directed by Engr-n-Charge.
M&L APP based polymeric membrane minimum weighing 3 kg/sqm and minimum 3 mm thick reinforced with polster non woven fabric (wt. not less than 150 gms/sqm) laid on primed surfaced by torch applicaion complete all as specified including removal of existing treatment complete all as specified and as directed by Engr-in-Charge.
Supply only Integral water proofing compound complete all as specified and directed.
S&F in repair viterous china wash down closet pan (pedestal pattern) including connection to drain and flushing pipe etc and plastic seat cover complete all as specified and directed.
S&F in repairs PVC valveless syphonic action type flushing cistern 10 lit capacity low level white with inlet, ball valve, float and handle including brackets and 32mm PVC flush pipe complete all as specified and directed.
Taking up or down, 20mm dia bore, GI tubing, medium grade, complete all as specified and as directed by Engineer-in-Charge.
S&F in repairs 32mm dia for high density polythelyne pipes (CPVC) of pressure rating 06 kgf/cm2 fixed complete to concealed wall or in floors etc. complete all as specified and directed.
S&F in repairs wash hand basin in repair Vitreous china white flat back size 550x400mm excluding taps, waste, chain and plug and porcelain stopper but including brackets complete all as specified and directed.
Taking up or down, 15mm dia bore, GI tubing, medium grade, including removal from site, complete all as specified and as directed by Engineer-in-Charge.
S&F 15mm dia for high density polythelyne pipes (CPVC) of pressure rating 06 kgf/cm2 fixed complete to concealed wall or in floors etc. complete all as specified and directed.
S&F 20mm dia for high density polythelyne pipes (CPVC) of pressure rating 06 kgf/cm2 fixed complete to concealed wall or in floors etc. complete all as specified and directed.
S&F 15mm dia Pillar taps fancy type, chromium plated, screwed down high pressure, with or without lettered ‘Hot' or ‘Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed.
S&F 15mm bore Bib tap fancy type chromium plated screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
S&F PVC connection 15mm size with PTMT nuts of length 750mm complete all as specified and directed.
S&F 15mm dia brass Stop valves screwed down, high pressure, screwed both ends for iron pipe or for unions and fixed 15mmbore complete all as specified and directed.
S&F in repair Vitreous China Urinal, Half stall type, white all as specified including flushing pipe and waste pipe in repairs complete all as specified and directed.
S&F in CP 15mm, stop valves/ angle cock (Push type), cast copper alloy with crutch or butterfly handle, screwed down, high pressure, screwed both ends for iron pipe for urinals complete all as specified and directed.
M&L Granite (of any type) tiles 20mm thick machine cut, with grey cement slurry & pointed with white cement with admixure of pigment to match the shade of granite stone including cutting & polishing types and fixing to wall for urinal partition complete all as specified and directed.
S&F for chromium plated urinal spindle spreader 15mm fix to urinal complete all as specified and directed by engineer in charge.
S&F CP hand shower (Health faucet) with 15mm dia, 1.2m long flexible tube & wall hook complete all as specified and directed.
M&L PVC (SWR) floor trap 75mm dia plain with grating including jointing with solvent cement complete all as specified and directed.
S&F in repairs, PVC (SWR) gully trap 125/110mm, setting and jointing with solvent cement complete all as specified and directed.
S&F Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted & fixed in position all as specified in SSR Part-I 1000 Ltrs capacity including all fittings complete all as specified and directed.
S&F Gun-metal, globe or gate valves 20mm bore, with iron wheel head, screwed both end for iron pipe complete all as specified and directed.
Demolition and breaking up of drain pipes (Salt glazed ware, AC or Reinforced concrete) of 200mm internal dia set in cement mortar complete all as specified and as directed.
M & L RCC drain pipes of 200mm bore, class NP2, with collars laid and jointed, laid in tenches and jointed in CM 1:1 complete all as specified and as directed.
M&L for precast cement concrete 1:2:4, type B1 (using 20 mm graded stone aggregate), as in man holes cover slabs etc including necessary form work and set in CM 1:6, complete all as specified and as directed. Note:- Reinforcement will be measured and paid seperately
M&L for Mild steel TMT bars 10mm dia and over , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
S&F PVC (SWR) 100/110mm bore single socketed pipes in any length with rubber ring joints fixed to wall / floor with pvc clamps complete all as specified and directed.
S&F in repairs PVC(SWR) bend/shoe for 100/110 mm dia complete all as specified and directed.
Cutting into existing manholes for connecting new 150mm drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B1 smooth finished, and reforming benching as required for 200/225mm dia pipe complete all as specified and as directed.
S&F Ball brass valves 25mm bore, high pressure, with polythene float & flynut complete, screwed for iron pipe or brass ferrule complete all as specified and directed.
Taking down carefully copper/aluminum point wiring (light, fan socket or power) complete incl. (fitting such as switches, ceiling roses, pendants, regulators, lights,sockets etc), removing materials to store for keeping in safe custody and making good disturbed surfaces of walls, floors etc, complete all as specified and directed.
Taking down unserviceable sub main wiring of any size two/foue single core including earth wire and PVC conduit/ casing capping and removing materials from site and making good the disturbed surface of wall etc complete all as specified and directed
Material and labour for concealed point wiring with 1.5 Sqmm nominal cross sectional area single core 1100 Volts grade, multistranded, FRLS (ISI marked) PVC insulated unsheathed copper conductor cable in and including PVC concealed conduit of minimum 20mm dia of complete with and including all fittings & accessories and terminated to and including modular boxes and modular white cover plates of suitable size including continuous earth wire of size 1.5 Sqmm (nominal cross sectional area) single core, FRLS (ISI marked) PVC insulated multistranded copper conductor cable, unsheathed and connected to common earth and earth dolly for one light point controlled by one, one way switch, complete all as specified and directed. Note:- Cutting and chasing will be measured and paid seperately.
-ditto- All as per item No. 60 above but for one fan point control by one way modular switch
-ditto- All as per item No. 60 above but for one 3 pin modular socket outlet 6 amps, on same board with modular switches.
All as per item No. 60 above but using 4.0 Sqmm single core copper conductor cable multistranded PVC insulated unsheathed 1100 volts grade for 3 pin 6/16 Amps modular switch socket point including running 4.00 Sqmm copper conductor PVC wire as earth continuity conductor on independant board.
Supply and fixing switch modular type, single pole, one way 6Amp 230 Volt complete all as specified and directed.
Supply and fixing socket outlet modular type, 2 moduler, 6 Amp 5 pin, 230volts complete all as specified and directed.
Supply and fixing switch Modular type, single pole, one way 16 Amp 230volt complete all as specified and directed.
Supply and fixing socket outlet modular type 6/16 Amp 230volts complete all as specified and directed.
Supply and fixing ceiling rose, 3 phase, PVC/Polycarbonate, insulated body (ISI Marked) complete all as specified and directed.
Supply and fixing Exhaust fan, heavy duty, 300 mmsweep metal body with louvers, AC single phase, 230 Volts, 1400 rpm and connecting up with and including necessary 3 core PVC insulated copper flexible cord of size 23/0.019 from exhaust fan to the ceiling rose including making hole in the wall and making good edges in cement plaster complete all as specified and directed.
Supply and fixing angle lamp holder insulated body for fixing and including LED bulb 9 W non dimmable type complete all as specified and directed
Supply and fixing 10 W LED tube light fitting box type 2 feet, 220 V AC decorative type with driver including connecting up with copper flexible wire of suitable size complete all as specified and directed.
Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, LED tube light connecting up with copper flexible wire of suitable size from ceiling rose complete all as specified and directed .
Material and labour for Submain wiring with 2 runs of single core 4.0 sqmm PVC insulated unsheathed multistranded 1100 volts grade with copper conductor drawn through existing conduit including one run of single core 4.0 sqmm PVC insulated unsheathed multistranded 1100 volts grade with copper conductor cable as earth continuty conductor along with the wiring and connected from DB to DB/main board including removing the existing unserviceable sub main wiring and making good the disturbed surface to match with the existing all as specified and as directed.Note:-Two runs of cable, one run of earth contuinity conductor and one run of conduit shall be measured as one unit length.
Material and labour for Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of andings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed conduit wiring, etc., and making good all as specified and as directed
Supply and fixing sheet metal enclosure MCB DB 4 way SPN double door suitable for 240 V fixed flush on walls including cutting Knitch and making good disturbed surfaces complete all as specified and directed.
Supply and fixing MCB, SPN, AC, 240 volts of 06 to 40 Amps capacity "C" series and making connections complete all as specified & directed.
Supply,installation,testing and commissioning of water heater storage type, "5 star rated" suitable for single phase 230v, 50 HZ, AC supply, 2 KW heating element, thermostat for water temperature and safety thermostat stove enamel outer body including minimum 1 mtr of three core 2.5 Sq mm twistesd copper conductor cable PVC sheathed, three pin plug top with hot and cold PVC pipe for inlet and outlet of the connection suitable for 15 mm bore GI pipe confirming to relevant IS of 50 ltrs capacity complete with all fixing arrangement including other accessories required all as specifid and as directed by Engr-in-charge. Make :- Havells Model No GHWAMGSWH050 Monza Dx series or equivalent in Bajaj/Caldia/Recold/Usha.
Supply and fixing Mild steel galvanized steel tubing of 15 mm bore with screwed socket joints, medium grade, together with all fittings (such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc.) and fixed complete to walls and ceiling with clips, wall hooks, wooden plugs or laid in floors including , screwing and waste and for forged bends on piping as required , cutting through walls, floors and their making good to match with the existing specifications complete.
Supply and fixing Bib taps, cast copper alloy,screwed down, screwed for iron pipe, 15mm bore of pipe for hot water of geyser all as specified and as directed .
M & L Submain wiring on surface with 2 runs of single core FRLS 10 sqmm PVC insulated unsheathed multistranded 1100 volts grade with copper conductor drawn through and including non-metalic rigid PVC conduit and conduit accessories of medium grade not not less than 32 mm dia including two run of single core FRLS 10 sqmm PVC insulated unsheathed multistranded 1100 volts grade with copper conductor cable as earth continuty conductor along with the wiring all as specified and as directed.Two runs of cable, one run of earth contuinity conductor and one run of conduit shall be measured as one unit length.
Supply and fix in repair Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20A complete including taking down unserviceable enclosure all as directed by Engr in Charge. .
Supply and fixing MCB Single Pole (SP) C curve 10kA breaking capacity of 6 to 40 Amp housing in DB, 240 Volts in proper position all as specified and as directed
Supply and fixing MCB Single Pole and neutral (SPN) C curve 10kA breaking capacity of 6 to 40 Amp housing in DB, 240 Volts in proper position all as specified and as directed
Supply and replace MCB double door DB SPN 8 way with 200 Amps busbar including removing the existing unserviceable one and making good the distrubed surface to match with the existing surface.
Supply and fixing MCB, SP, AC, 240 volts of 06 to 40 Amps capacity "C" series and making connections complete all as specified & directed.
NEWS CONSTRUCTIONS
K LAKSHMAN SINGH AND CO
SAI RUPA CONSTRUCTIONS
Sri Associates
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .