| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.1 LAdmitted-Finance | ₹7.1 L | L1 | Admitted-Finance |
| 2 | Rejected-Technical | - | - | Rejected-Technical Reject |
| 3 | Rejected-Technical | - | - | Rejected-Technical Reject |
| 4 | Rejected-Technical | - | - | Rejected-Technical Reject |
| 5 | Rejected-Technical | - | - | Rejected-Technical Reject |
| Sl No | Description | Qty | Unit | RAJEEV BOHRE L1 |
|---|---|---|---|---|
| 1.00 | On grid Solar Photo voltaic Power Plant-Supply, Installation, Testing and Commissioning of on grid Solar Photo voltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections,earthing, mountedon Aluminium/GI structure of suitable strength with following components complete as required:- a) Solar Photo voltaic Module of capacity 330Wp or aove, manufactured in India, conforming to IS14286/ IEC61215, IS/IEC61730-Part-1, IS/IEC61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/systems must be warranted for their out put peak watt capacity, which should not be less than 90%at the end of 10 years and 80%at the end of 25 years. b) Power Conditioning Unit (PCU)of 350-800V DC Input voltage range and 400 VAC, three phase, 4wire, 50Hz+/- 2.5Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency.c) Data Monitoring System complete with accessories.d)Fixing of Array junction box & Main junction box with IP65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. e) Lightning and surge voltage protection. f)Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessories etc | 8 | KWp | 79,500 ₹6.4 L |
| 2.00 | Three phase whole current smart/other meter (10-200)A,(Meter cost and Meter testing charges) | 1 | each | 15,000 ₹15,000 |
| 3.00 | Single core PVC insulated FRLS cableSupplying and drawing single core PVC insulated cable FRLS with copper multi strand conductor ISI marked in existing rigid PVC
casing and capping/conduit in surface or concealed as per
specification.4 X 6.00 sq. mm. | 182 | meter | 300 ₹54,600 |
Tender Value
₹6.6 L
EMD Value
₹6,570
Closing Date
4 May 2026, 5:30 pmClosed
Rambabu Dinkar
Municipal Corporation Gwalior
Providing Supplying and Installation of Solar panel at Shabd pratap aashram file No. 09/26/x6/4.2nd Call.
2026_UAD_492225_2
MPGMC/09/26X6/4/Elec/2025-26
Open Tender
Miscellaneous Works
30 days
Electricity Department
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,000
₹6,570
1 Jun 2026
17 Apr 2026
6 May 2026
18 Apr 2026
4 May 2026
27 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | Item Code |
|---|---|---|---|---|---|---|
| 1 | On grid Solar Photo voltaic Power Plant-Supply, Installation, Testing and Commissioning of on grid Solar Photo voltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections,earthing, mountedon Aluminium/GI structure of suitable strength with following components complete as required:- a) Solar Photo voltaic Module of capacity 330Wp or aove, manufactured in India, conforming to IS14286/ IEC61215, IS/IEC61730-Part-1, IS/IEC61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/systems must be warranted for their out put peak watt capacity, which should not be less than 90%at the end of 10 years and 80%at the end of 25 years. b) Power Conditioning Unit (PCU)of 350-800V DC Input voltage range and 400 VAC, three phase, 4wire, 50Hz+/- 2.5Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency.c) Data Monitoring System complete with accessories.d)Fixing of Array junction box & Main junction box with IP65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. e) Lightning and surge voltage protection. f)Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessories etc | - | KWp | - | - | BI01010001010000000000000515BI0100001114 |
| 2 | Three phase whole current smart/other meter (10-200)A,(Meter cost and Meter testing charges) | - | each | - | - | BI01010001010000000000000515BI0100001115 |
| 3 | Single core PVC insulated FRLS cableSupplying and drawing single core PVC insulated cable FRLS with copper multi strand conductor ISI marked in existing rigid PVC
casing and capping/conduit in surface or concealed as per
specification.4 X 6.00 sq. mm. | - | meter | - | - | BI01010001010000000000000515BI0100001116 |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.03 MB
Annexures.pdf
Tender Documents • 0.05 MB
BOQ_604028.xls
BOQ • 0.23 MB
Estimate.pdf
Additional Documents • 3.51 MB
NIT.pdf
Additional Documents • 1.67 MB
Download all tender documents and submit your bid