| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.2 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹33.9 L+₹4.6 L (15.8%)Rejected-Finance SNEH NAGAR COLONY NEAR ABKARI OFFICE SHIVAJI WARD SAGAR MP 47000 | SAGAR | SAGAR | MP | 47000 | L2 | Rejected-Finance Not lowest bidder |
Tender Value
₹42 L
EMD Value
₹84,000
Closing Date
19 Feb 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINEER SAUGOR
Military Engineer services Garrison Engineer Saugor MP- 470001
Repair/replacement of disinfectants, standby sets and other misc E/M related works under GE Saugor.
2024_MES_638043_1
GE/SGR/TOK-68 OF 2023-24
Open Tender
Miscellaneous Works
Item Rate
180 days
Saugor
Class D category b (i) and as per tender documents
7 documents required · 7 mandatory
₹500
GARRISON ENGINEER SAGAR
₹84,000
Yes
13 Mar 2024
18 Jan 2024
21 Feb 2024
18 Jan 2024
19 Feb 2024
2 Feb 2024
19 Jan 2024 - 27 Jan 2024
Amount
M&L for checking of existing APFC panel every month total 11 times i.e. every month interval at different location ( Barthuma filtration plant, Chittora pump house and Rajghat pump house) should be capable of improvement of PF upto 0.99 on the average of monthly consumption in each phase, at the different loads of Pump set and during the off load entire installation in matching with Metering Equipment of MPEB overall the maintaining the PF 0.99 in APFC panel as well as MPEB meter including checking of all internal wiring and connection with relay, contactor, CT etc all as per site requirement of APFC panel complete all as specified and directed. (Note : (i) Quoted rates shall be deemed to include opening of panel accessories and taking the defective items to the approved workshop for relay adjustment with reference to variable capactior acoording to load requirement. (ii) Spare parts any shall be measured and paid separately under relevant items for fixing only. (iii) Records of checking of existing APFC panels should be submitted by the contractor.
M&L for checking of existing APFC panel at Area I and Area II should be capable of improvement of PF upto 0.99 on the average of monthly consumption in each phase, at the different loads of Pump set and during the off load entire installation in matching with Metering Equipment of MPEB overall the maintaining the PF 0.99 in APFC panel as well as MPEB meter including checking of all internal wiring and connection with relay, contactor, CT etc all as per site requirement of APFC panel complete all as specified and directed. (Note : Quoted rates shall be deemed to include opening of panel accessories and taking the defective items to the approved workshop for relay adjustment with reference to variable capactior acoording to load requirement. (iii) Digital records of checking of existing APFC panels should be subitted by the contractor
Supply only capacitor duty contactors type MO C 25 with add on accessories suitable for capacitor bank of existing APFC panel including thimbles connection complete all as specified and directed.
Supply only capacitor duty contactors type MO C 20 with add on accessories suitable for capacitor bank of existing APFC panel including thimbles connection complete all as specified and directed .
Supply only capacitor duty contactors type MO C 15 with add on accessories suitable for capacitor bank of existing APFC panel including thimbles connection complete all as specified and directed .
Supply only capacitor duty contactors type MO C 12.5 with add on accessories suitable for capacitor bank of existing APFC panel including thimbles connection complete all as specified and directed .
Supply only power factor relay RM-12/NAAC 3P12 for APFC panel of any size and any capacity including adjusting and setting up the power factor till 0.99 complete all as specified and directed.
Supply only MCB three pole 63 Amp 240 Volts 'C' series 10 KA complete all as specified and directed.
Supply only current transformer of ration 300/5 Amps complete all as specified and directed.
Supply only current transformer of ration 200/5 Amps complete all as specified and directed.
Supply only heavy duty capacitor cylindrical/box type 4 KVAR, 440V suitable for existing capacitor bank at site complete all as specified and directed and directed.
Supply only heavy duty capacitor cylindrical/box type 20 KVAR, 440V suitable for existing capacitor bank at site complete all as specified and directed and directed.
Supply only heavy duty capacitor cylindrical/box type 25 KVAR, 440V suitable for existing capacitor bank at site complete all as specified and directed and directed.
S&F in replacement of LED Street/Building Light fixture with IP-66 protected die-cast aluminium housing and heat resistive toughened glass. LED shall be having LM-79 and LM-80 complied as per L-70 standard. LEDs should be tested for minimum 10,000 burning hours with 5700-6000 K CCT. Maximum power consumption shall not exceed 45W and system lumens shall not be more than 9,000. Optics shall be properly designed with Polycarbonate Lenses to avoid dark patches on the road. Street light without lenses will not be acceptable. Driver shall be 3 stage "Constant Current Constant Voltage" with voltage range of 150-270V AC. Output voltage of driver should be complied to Safety Extra Low Voltage norms not exceeding 60 V DC. Note: (i) The item rate shall deem to include provision of weather proof PVC insulated aluminium conductor cable 1.5 Sqmm, 3 core as required. (ii) Contractor shall produce warrinty certificate and LEDs used in the product shall comply with EN-62471 for photo - biological safety and certificate for the same from manufacturer shall be provided. Luminaire manufacturer shall produce certificate of association with LED manufacturer for minimum two years.
S&F in replacement of LED Street/Building Light fixture with IP-66 protected die-cast aluminium housing and heat resistive toughened glass. LED shall be having LM-79 and LM-80 complied as per L-70 standard. LEDs should be tested for minimum 10,000 burning hours with 5700-6000 K CCT. Maximum power consumption shall not exceed 30W and system lumens shall not be more than 9,000. Optics shall be properly designed with Polycarbonate Lenses to avoid dark patches on the road. Street light without lenses will not be acceptable. Driver shall be 3 stage "Constant Current Constant Voltage" with voltage range of 150-270V AC. Output voltage of driver should be complied to Safety Extra Low Voltage norms not exceeding 60 V DC. Note: (i) The item rate shall deem to include provision of weather proof PVC insulated aluminium conductor cable 1.5 Sqmm, 3 core as required. (ii) Contractor shall produce warrinty certificate and LEDs used in the product shall comply with EN-62471 for photo - biological safety and certificate for the same from manufacturer shall be provided. Luminaire manufacturer shall produce certificate of association with LED manufacturer for minimum two years.
S&F in replacement of 150 watt LED flood light fittings having long life of high power LED with SMD LED exclusive innovative dia cast aluminium IP-66 built in IP-67 electronic driver with APFC, lower THD, open circuit protection, over voltage protection, surge protection up to 10KV with built in SPD & other safety as per IS-15885 part -2 ,Sec 13, IEC 60598-1 of operating voltage 140-270V avg life 50,000 hours complete manufacture prove all test certificate as per protection for minimum 2 years from manufacturing companies complete all as specified and directed.
S&F in replacement of 250 watt warm white LED flood light fittings having long life of high power LED with SMD LED exclusive innovative dia cast aluminium IP-66 built in IP-67 electronic driver with APFC, lower THD, open circuit protection, over voltage protection, surge protection up to 10KV with built in SPD & other safety as per IS-15885 part -2 ,Sec 13, IEC 60598-1 of operating voltage 140-270V avg life 50,000 hours complete manufacture prove all test certificate as per protection for minimum 2 years from manufacturing companies complete all as specified and directed.
S&F in replacement of LED decorative post-top light 35 watts, IP65, energy saving, environment friendly long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LED as light source complete all as specified and directed.
S&F in replacement of CONE LED bollard 8W, two feet height IP 65 series acts as a imposing street furniture. The elegant yet minimalsitic design acts silent observer and giving light, diffuser at the upper portion acts a beacon of path guidance in a landscape environment complete all as specified and directed.
S&F in repalcement of MUSHROOM (PRISMATIC) suitable for LED lamp upto 20W decorative gate light made up of high grade unbreakable polycarbonate material suitable for retrofit LED lamp B22 base with suitable size of flexible wire complete all as specified and directed.
S&F in repalcement of MOON (PRISMATIC) width 200mm suitable for LED lamp upto 20W decorative gate light made up of high grade unbreakable polycarbonate material suitable for retrofit LED lamp B22 base with suitable flexible wire complete all as specified and directed.
S&F in replacement of bollard light 15 watts, one meter long, IP 65, energy saving, environment friendly long life aesthetically designed aluminium landscape luminaire for difused lighting with high power LED as light source complete all as specified and directed.
S&F in repairs flat cable flexible copper of size 1.5 sqmm 3 core, 1100 volt grading complete all as specified and directed.
M&L in replacement of stranded aluminium conductor flat twin core PVC insulated unsheathed 1100V 10 Sqmm 2 core complete all as specified and as directed.
S&F in replacment of Nature switch complete with timer , contactor, relays and suitable rating MCB s for incoming and out going in built in suitable sheet metal enclosurr of single phase integrated models of cpacity 8 KW complete all as specified and as directed (Make:-Cat Part No. SWADEEP-02 EC 8kW 1P of Healer Enterprises or equivalent as approved by GE)
Supply, laying, connecting and testing in replacment of cable XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 Volt grade cross sectional area 16 Sqmm 4 core complete all as specified and directed.
All as Srl item No. 26 above but Size 10 sqmm 2 core
All as Srl item No. 26 above but Size 6 sqmm 2 core complete all as specified and directed.
Excavation in trenches in soft/ loose soil not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr depth for laying of cables/poles or foundation etc and getting out complete all as specified and directed.
Returning, filling, including spreeding leveling watering and well ramming in layers not exceeding 25 cm apart complete all as specified and directed.
Removing of surplus excavated soil to distance not exceeding 50 Mtr from starting point and depositing where directed at a level not exceeding 1.5 Mtrs above the starting point complete all as specified and directed.
M&L for river unwashed sand cushioning with a layer of sand 80mm thick before laying of cable and 150mm thick after laying of cable to trenches complete all as specified and directed.
Supplying and laying un-reinforced precast concrete cable cover, class LV, type 1, flat size 250mm x 150mm x 40mm complete all as specified and directed.
S&F in repair pipe galvanised iron light grade 40 mm dia (ISI marked) with all fittings laid in trenches or on pole, crossing of road,fixed on wall for protection of cables complete all as specified and directed.
M&L for checking and repair of all-in-one solar street light of existing from 15W to 30W in site/taking to workshop complete all as specified and directed
S&F in replacement of main circuit board for all-in-noe street light of existing suitable for 15 to 20W light complete all as specified and directed
S&F in replacement of main circuit board for all-in-noe street light of existing suitable for 24 to 30W light complete all as specified and directed
S&F in replacement of aesthetically designed decorative hot dipped galvanised mild steel step pole 3M height with grey powder finish, compatable for all post top range. Window-plasma cut & duly chamfered opening window of 300x110mm for terminal connectors & mounting accessories. window cover is fitted with allen screws to the pole complete all as specified and directed.
Supply and fixing swimming pool light underwater SMD (LED) Light Water Proof, stainless steel,High Brightness, Wall mounted round shape with Warm White/ Blue/ RGB 12 Volt 20/15 Watt with complete accessories all as specified. Make- Austin
S&F SMPS fuse mode power supply suitable for minimum 08 Nos swimming pools light (SMD (LED) Water Proof Resin filled.
M&L for plain cement concrete (1:3:6) type C-2 (using 40mm graded stone aggregates) as in foundation of stay assy/ pole etc, including form work complete all as specified and directed.
S&F PVC conduit 25mm dia including fixing on wall/pole with necessary fixing arrangement complete all as specified and directed.
S&F in replacement of EROS POST TOP 70W aesthetically designed IP 66 LED post top with aluminium enclosure, powered with high power LEDs as light source and die casted heat sink exhibiting calssic victorian look with symmetrical light distribution, suspended mounting arrangement and excellent heat dissipation for long life complete all as specified and directed.
S&F in replacement of EROS DECORATIVE ARMS orbit plus family decorative arms in different desigms, shaped and length to compliment the eros LED post top and poles family complete all as specified and directed
S&F in replacement of EROS CASTING POLES 3 mtr height family of decorative casting poles in different desighns, shaped and heights to compliment the eros LED post top family. These poles can infuse life into roads high importance and visibilty complete all as specified and directed.
M&L for Bus Bar Panel of capacity 400 Amps copper bus bar 04 Nos with fixed on insulator welded with iron angle of size 50x50x6 mm thick and 60cm height grouting in floor, 45 mm depth grouting with PCC 1:3:6 upto ground level complete all as specified and directed.
M&L for Bus Bar Panel of capacity 200 Amps copper bus bar 04 Nos with fixed on insulator welded with iron angle of size 40x40x6 mm thick and 60cm height grouting in floor, 45 mm depth grouting with PCC 1:3:6 upto ground level complete all as specified and directed.
Supply only bleaching powder 30% chlorine content complete all as specified and directed.
Supply only DOL starter suitable for 2.0 HP capacity motor as per existing sample complete all as specified and directed.
Taking down the existing worn out fanbelt ( V belt) for the existing Generator set installed at various installation and replaced with new fan belt complete all as specified and directed.
S&F battery 12V, 100AH for DG Set complete all as specified and directed.
S&F in repair AVR from alternator up to 90 KVA capacity DG Set complete all as specified and directed.
All as per item No. 53 above but alternator capacity 90 to 125 KVA complete all as specififed and directed.
shubhanshu traders
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .