Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.9 LAccepted-AOC 126 NARANG COLONY JANAK PURI NEW DELHI 110058 | NEW DELHI | NEW DELHI | DELHI | 110058 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹52.2 L+₹1.5 L (2.99%)Rejected-Finance NOT AVAILABLE | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹53.5 L+₹2.9 L (5.70%)Rejected-Finance | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹65.4 L+₹14.8 L (29.2%)Rejected-Finance | L4 | Rejected-Finance Being L4 |
Tender Value
₹66 L
EMD Value
₹1.2 L
Closing Date
25 Sept 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE (AF) Palam Delhi Cantt-10
HQ CWE (AF) Palam Delhi Cantt-10
RENOVATION OF FRONT BLOCK OF SINGLE LIVING IN ACCN OF CAMERO OFFICERS MESS UNDER GE (AF) SUBROTO PARK DELHI CANTT-10
2021_MES_454379_3
CA NO CWE/PM/SP-09/2021-22
Open Tender
Civil Works
Item Rate
180 days
GE (AF) Subroto Park Delhi Cantt
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
GE (AF) Subroto Park
₹1.2 L
Yes
5 Oct 2021
4 Sept 2021
27 Sept 2021
4 Sept 2021
25 Sept 2021
11 Sept 2021
60 days
Amount
BOQ PART-I (B/R WORKS)
Dismantling floor,hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete, all as specified and directed by Engineer-in-Charge.
Demolition of RCC, of any description and in any position not otherwise specifically provided for (incl reinforcement cut as required to facilities demolition) complete, all as specified and directed by Engineer-in-Charge.
M&L Virified Ceramic light shade tiles 9 to 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match flooring( in any pattern) and jointed with coloured cement matching with surfaces of tiles as in floor 15 mm thick cement screed in CM 1:4 and pointed with coloured cement matching with surfaces of tiles as in floor complete, all as specified and directed by Engineer-in-Charge.
All as per item No 1.03 hereinbefore but as in skirting including 10mm thick backing coat in cement mortar 1:4 complete, all as specified and directed by Engineer-in-Charge.
M&L for Glazed ceramic coloured tiles in vertical surface 300x450X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match including 10mm thick screed in cement mortar 1 :4 and pointed in white or coloured cement to match the shade complete, all as specified and directed by Engineer-in-Charge.
S&F non skid coloured ceramic tiles area of each tiles exceeding 0.11sqm but not exceedng 0.18 Sqm and 7mm thick as in floor set & jointed in neat cement slurry & pointed in coloured cement to match over 15mm thick screed n cement mortar1:4 complete, all as specified and directed by Engineer-in-Charge.
All as per item No 1.06 hereinbefore but as in skirting including 10mm thick backing coat in cement mortar 1:4 complete, all as specified and directed by Engineer-in-Charge.
Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc, laid in any mortar complete, all as specified and directed by Engineer-in-Charge.
Dismantling water tanks of capacity exc 250 liters & n exc 500 liters capacity and removing to store complete, all as specified and directed by Engineer-in-Charge.
S & F rotational moulded polyethylene water tank 500 litre capacity tripple layer (white colour) (cylindrical vertical with closed top) hoisted and fixed as specified in SSR Part-I complete, all as specified and directed by Engineer-in-Charge.
S&F 20 mm bore gun metal globe or gate valves with iron wheel head screwed both ends for iron pipe and fixed complete, all as specified and directed by Engineer-in-Charge.
S&F 20 mm ball brass valves high pressure with polythene float and flynut complete screwed for iron pipe or brass ferrule and fixed complete, all as specified and directed by Engineer-in-Charge.
S&F in repairs vitreous china wash basin white flat back of size 630x450mm including brackets and waste pipe complete, all as specified and directed by Engineer-in-Charge.
S&F in repairs single lever wash basin mixer with popup waste system and 450 mm long braided hoses chromium plated complete, all as specified and directed by Engineer-in-Charge.
S & F in repairs CP waste coupling 32mm size half threaded with 130mm height complete, all as specified and directed by Engineer-in-Charge.
S&F in repairs 15 mm bore angle valve chromium plated with wall flange and fancy type with high pressure screwed down with CP flange complete, all as specified and directed by Engineer-in-Charge.
S&F in repairs PVC bathroom mirror cabinet of size 450x600mm complete, all as specified and directed by Engineer-in-Charge.
S&F in repairs wall mounted vitreous china wash down water closet pan, white (including fixing bolts, Push cock flushing cistern and flush pipe) including connection to drain (or outgoing pipe) and to flushing pipe, anti syphonage pipe, Plastic water closet seat, black / white , closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device etc complete, all as specified and directed by Engineer-in-Charge.
S&F in repairs health faucet with 1.0 m long easy flex tube in chrome finish and wall hook complete, all as specified and directed by Engineer-in-Charge.
S & F in repairs CP paper holder of complete, all as specified and directed by Engineer -in-Charge.
S&F in repairs jet spray with necessary fixing arrangement complete, all as specified and directed by Engineer-in-Charge.
S&F in repairs CP towel ring of approved make complete, all as specified and directed by Engineer-in-Charge.
S&F in repairs bib tap cast copper alloy fancy type chromium plated with crutch or butterfly handle screwed down for 15mm bore pipe complete, all as specified and directed by Engineer-in-Charge.
S&F in repairs CP soap dish of complete, all as specified and directed by Engineer-in-Charge.
S&F in repairs corner glass shelf with bracket of complete, all as specified and directed by Engineer-in-Charge.
S&F in repairs 15mm bore chromium plated shower rose complete, all as specified and directed by Engineer-in-Charge.
S&F in repairs 15mm dia Brass CP wall mixer with provision for over head shower with 115 mm long bend pipe on upper side, connecting legs & wall flanges for mixing hot & cold water screwed down for iron pipe complete, all as specified and directed by Engineer-in-Charge.
S&F in repairs brass powder coated cloth hanging hooks set of six hooks complete, all as specified and directed by Engineer-in-Charge.
S&F in repairs 15mm bore two way angle valve chromium plated with wall flange and fancy type high pressure screwed down with CP flange complete, all as specified and directed by Engineer-in-Charge.
S&F in repairs Sheet glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12 cm wide with chromium plated bracket guard and railing 60 cm complete, all as specified and directed by Engineer-in-Charge.
S & F in repairs CP towel racks with lower hanger complete, all as specified and directed by Engineer-in-Charge.
S&F in repairs PTMT grating round of 100mm dia (Miniumum wt 50gms) complete, all as specified and directed by Engineer-in-Charge.
S&F in repairs PTMT grating round of 125 mm dia with waste hole (Minium wt 100 gms) complete, all as specified and directed by Engineer-in-Charge.
S&F in repair CP connection 15mm size for Hot & Cold water with CP nuts of length 450mm long all as specified and directed by Engineer-in-Charge.
Taking down steel tubing and connections 20mm bore complete, all as specified and directed by Engineer-in-Charge.
All as per item No 1.36 hereinbefore but 15mm bore complete, all as specified and directed by Engineer-in-Charge.
S&F 20mm bore tubes, 'medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete, all as specified and directed by Engineer-in-Charge.
All as per item No 1.38 hereinbefore but 15mm bore complete, all as specified and directed by Engineer-in-Charge.
Providing water proofing treatment to RCC sunken slab as specified and directed as under (a) cleaning the exisiting RCC sunken slab and vertical wall/RCC beam and hacking the surface (b) 15 mm thick plastering over the floor & vertical surface in CM 1:4, mixed with liquid water proofing compound @ 200 per 50 kg of cement trowelled to even and smooth finish without using extra cement (c) Filling the sunken portion with water for 72 hrs and carrying out the ponding test. (Any leakage/seepage noticed shall be repaired) (d) Applying two coats of elastometric acrylic water proof coating make : Dr Fixit of pidilite, Tapecrete from Cico or equivalent in sika as per sqm in each coat with roller application (Note: each coat of elastomeric acrylic compound requires 6-8 hrs to dry up itself second coat shall be applied on getting the first coat completely dired up. Min quantity required for coating as per manufacture instruction) complete, all as specified and as directed by Engineer-in-Charge.
M&L for PCC 1:4:8 type D2 (using 40mm graded stone aggregates) as in mass concrete in floors and sunken portion complete all as specified and as directed by Engineer-in-Charge.
Taking down cement or cement lime plaster on brick walls incl racking out joints hacking for key scrubbing down with water etc. complete all as specified and as directed by Engineer-in-Charge.
M&L for rendering 15mm thick in CM 1:6 on other than fair faces of brick work or concrete surfaces of walls, finished even and smooth (without using extra cement) complete all as specified and as directed by Engineer-in-Charge.
M&L for rendering 15 mm thick in CM 1:4 on fair faces of brick surfaces or concrete surfaces even and smooth without using extra cement complete all as specified and as directed by Engineer-in-Charge.
M&L for rendering 10 mm thick in CM 1:4 on concrete surfaces of ceiling, even and smooth without using extra cement. complete all as specified and as directed by Engineer-in-Charge.
Supply only liquid water proofing compund only complete, all as specified and directed by Engineer-in-Charge.
M&L for preparation of new plastered surfaces of walls, and applying two coats of distemper oil emulsion over a coat of primer incl 3mm thick elastomeric wall care putty on walls complete, all as specified and directed by Engineer-in-Charge.
M&L for preparation of new plastered surfaces of walls, and applying three coats of white wash on walls over a coat of primer complete, all as specified and directed by Engineer-in-Charge.
M&L for preparation of new plastered surfaces of walls, and applying two coats of cement based paint over a coat of primer complete, all as specified and directed by Engineer-in-Charge.
M&L preparation of new plastered or unplastered surface and applying three coats of white wash on ceiling complete, all as specified and directed by Engineer-in-Charge.
M & L for complete removal of existing treatment of surfaces by steel wire brushing, scraping down smoke soots, moulds, moss and efflorescent salts etc on wall and applying two coats of oil emulsion distemper over a coat of primer including 3mm thick wall care putty on wall complete, all as specified and directed by Engineer-in-Charge.
Taking down chowkats or frames not exc 1.5 Sqm each with shutters(without taking off shutters from the frames) and remove to store complete, all as specified and as directed by Engineer-in-Charge.
All as per Item No. 1.52 hereinbefore but exc 1.5 Sqm and n.exc 4 Sqm each complete, all as specified and directed by Engineer-in-Charge.
S&F in repairs for 18mm thick celuka PVC ply ends for supporting the hold of shelf / partition/drawers and shall provided 3 edges in size 18mm x 18mm as per required length. The front side of the edge visible in the front of the shelf / partition to be edge lipped by 18mm width x 1mm thick PVC sheet of density 600 kg/ cbm density manufactured by an ISO-9000 certified company, using solvent cement etc complete, all as specified and as directed by Engineer-in-Charge.
S&F telescopic GI powder coated drawer channel 450mm long with ball bearing complete, all as specified and directed by Engineer-in-Charge.
M&L 50mm dia polished cup board knob fixed in repair with nut, screw and washer of brass complete, all as specified and directed by Engineer-in-Charge.
Demolition of brick or stone boulder masnory, built in cement mortar including all quoins, arches, pillars, etc., but excluding ashlar facing, dressed stonework and percast concrete articles.complete, all as specified and directed by Engineer-in-Charge.
M&L for brick work with sub class 'B' bricks, staright or curved on plan exc 6.00 mtr mean radius, built in 1:6 cement mortar complete, all as specified and directed by Engineer-in-Charge.
M&L for brick work with sub class 'B' bricks, staright or curved on plan on plan to any radius in half brick thickness wall, built in 1:4 cement mortar complete, all as specified and directed by Engineer-in-Charge.
Demolition and breaking of 100mm dia drain pipes (salt glazed ware, AC or reinforcement concrete) set in cement mortar complete, all as specified and directed by Engineer-in-Charge.
S&F 110 mm dia bore PVC (SWR) bends, including removing for concrete and refixing with 1:2:4, type B1 (20 mm graded aggregate) or in 1:3 cement mortar complete, all as specified and directed by Engineer-in-Charge.
S&F PVC (SWR) 110 mm dia bore pipe single socketed, in any length with rubber ring joints fixed to walls, including necessary PVC clamps for fixing of pipes complete, all as specified and directed by Engineer-in-Charge.
M&L for reinforced cement concrete type B1, 1:2:4 (20 mm graded aggregate) as in chajjas, suspended slab etc, including necessary formwork complete, all as specified and directed by Engineer-in-Charge.
S&F mild steel bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete, all as specified and directed by Engineer-in-Charge.
M&L for preparation of old wooden surface of any despcription over 10 cm in width or girth and applying varnishing over a coat of filler coat of thin varnish to the existing hand rail at staircase and balcony and verandah complete, all as specified and directed by Engineer-in-Charge.
Cutting opening through brick wall built in cement mortar or cement lime mortar for door, window and other opening or enlarging existing openings, converting window into doors openings or cutting out defective brick work for under pinning, including providing fixing and removing shoring, cleaning and stacking bricks removing surplus serviceable bricks, hard core etc to store and rubbish not exec 50m complete, all as specified and directed by Engineer-in-Charge.
Supply and fixing in repairs MS powder coated in teakwood finish curtain rods (drapery) 25 mm dia, including set of brackets, channels etc complete, all as specified and directed by Engineer-in-Charge.
M&L for cement concrete type B0 1:2:4 (12.5 mm graded stone aggregate) providing cement concrete in roof kerbs or mud stops rounded or chamfered on edges, lintels upto 1.5 m clear span cills steps seismic and other similar bands plinth courses string courses lacing cources parapets and railing upto 60 cm in height coping kneelers apex stones bed plates kerbs not provided for in item 04028 water troughs and the like including weathering slightly rounded or chamfered angles and throating complete, all as specified and directed by Engineer-in-Charge.
S&F 100 mm size butt hinges extruded aluminium alloy with galvanised mild steel hinge pin anodised and fixed type C-21 complete, all as specified and directed by Engineer-in-Charge.
S&F 150 mm long aluminium anodised barrel tower bolts of extruded section and fixed complete, all as specified and directed by Engineer-in-Charge.
S&F 150 mm long aluminium handles cast type anodised complete, all as specified and directed by Engineer-in-Charge.
M&L for 75 mm thick PCC 1:3:6 type C2 as in plinth protection using 40 mm graded stone aggregate including making joints and filling with sand bitumen mastic complete, all as specified and directed by Engineer-in-Charge.
Demolition of cement concrete in ground floors and pavings n.exc. 15 cm thickness (below or above ground level) complete, all as specified and directed by Engineer-in-Charge.
M&L gunniting work to RCC work in col beams chajjas balcony slabs, landings, railings,parapets, projection etc by removing loose, concrete, cleaning of surfaces with wire brush and applying one coat of epoxy paint to rusted reinforcement with and incl welded wiremesh fabric or or wirenet of size not less than 95x95x 3mm, adhesive plaster grade for concrete admixture and providing gunniting pressure 2.5 Kg/sqm with admixture of one part of cement and 3.5 part of sand with thickness of 50mm average complete including and making the surface even & smooth incl 5mm thick plaster in CM 1;3 complete, all as specified and directed by Engineer-in-Charge.
All as per item No. 1.74 hereinbefore but 25mm thick for ceiling complete, all as specified and directed by Engineer-in-Charge.
Providing and fixing factory made UPVC white colour sliding window. three track made of extruded profiles with wall thickness of 2.3mm (+/0.2mm). Window profile with hollow section with multi chamber, frame (88mmx52mm), sliding sash (42mmx67mm), sliding mesh sash (42mm x 57 mm) sliding interlock (One vertical length in each shutters) (45.5mmx28mm) Glazing bead(24.5mm x 16mm ) will be mitered cut and fusion welded at all corners, including railing of holes for fixing hardware and drianage of water etc. making arrangement for fixing of hardware EPDM gasket 1.2 + 0.2 mm thick galvanised steel frame (30mmx18 mm) 2 Nos , sliding sash (30mmx18 mm), sliding mesh sash (26mm x 10 mm ) profile to be inserted in required profile, frame will be fixed to the wall with 8 mm x 100 mm long fasteners. Hardware [Touch lock of zinc alloyed (white powder coated) steel roller system stainless steel wire cloth 0.36 mm nominal dia of wire and average width of apreature 1.40mm and required accessories] complete, all as specified and directed by Engineer-in-Charge. Note :- The unit rate quoted by contractor including 5.5mm thick black glass, cost of glass and includes all other connected accessories. Net opening will be measured for payment purpose) area exceeding 2.00 sqm each .
Dismantling brick tiles or terracing tiles single layers laid on roof including removing the debris including mortar out side defence land complete, all as specified and directed by Engineer-in-Charge.
Taking out of APP modified water proofing membrane complete on roof surface and surface properly cleaned by wire brush complete, all as specified and directed by Engineer-in-Charge.
M&L for cement concrete in roof kerb and pcc bencing in cement concrete type B1 1:2:4 using 20 mm graded stone aggregate complete, all as specified and directed by Engineer-in-Charge.
M&L for preparation of plastered/concrete surfaces of roof and applying the under mentioned course of roof treatment complete all as specified and directed by Engineer-in-Charge.:- (a) 15 mm thick cement plaster (1:4) using Water proofing compound as per manufracturers instruction (b) Surface shall be throughly wire brushed, cleaned, washed, dried up properly and apply evenly a bituminuous primer coat conforming to IS @0.4 ltr /Sqm over concrete / plastered roof surface. (c) Applying evenly a tack coat of bitumen 85/25 grade @1.20 kg/ sqm. (d) Laying of 3mm thick APP membrane sheet (min weight 3 Kg/Sqm) consisting of a core of 160 gms/Sqm polyster non woven fabric mat protected on both sides with a high quality polymeric asphaltic mix again protected with thermo fusible HMHDPE FILM on dried primed surface by torch application method. APP membrane will normally be laid in length at right angle to the direction of slope. The over lap shall be minimum 100mm on longitudinal direction and 150mm on the transverse direction including cuttings, grooves etc. (d) Membrane bonded completely to the substrate & the over laps are then scaled/fused by flame. Note:- This treatement shall be done by the approved authorized applicators and guarantte of treatement shall be for 10 years.
M&L for cement concrete tiles 20 cm x 20 cm x 20 mm thick with grey cement and no pigment machine pressed over 15 mm thick screed bed or bedding layer of cement mortar 1:4 with liquid water proofing compound complete, all as specified and directed by Engineer-in-Charge. Note : Liquid WPC shall be measured and paid separately.
S&F stainless steel railing/grill pattern and design as approved and confirming to SS 304 complete, all as specified and directed by Engineer-in-Charge.
M&L for coloured granite slab, 20 + mm thick, as in Platforms of Kitchen and similar work etc., bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including Chamfering\Rounding the edges complete all as specified and as directed (colour & design approved by GE). Over 15mm thick screed bed in CM 1:4 complete, all as specified and directed by Engineer-in-Charge.
M&L for coloured granite slab, 12 to 15 mm thick, as in vertical surface of kitchen plateforms & similar work etc., bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including Chamfering\Rounding the edges complete all as specified and as directed (colour & design approved by GE). over 15 mm thick rendering in CM 1:4 complete, all as specified and directed by Engineer-in-Charge.
M&L for post construction anti termite treatment as per manufacturer's instructions complete, all as specified and directed by Engineer-in-Charge.
BOQ PART-II (E/M WORKS)
Taking down carefully copper/aluminium point wiring light, fan, light fittings, socket or power such as switches, ceiling roses, pendents, regulators, sockets and light fittings etc.removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditioned separately) and making good disturbed surface of walls, floors etc. complete all as specified and directed by Engineer-in-Charge.
M&L for point wiring with single core PVC insulated unsheathed 1100 volt grade cable with multi strand copper conductor of size 1.5 Sqmm FRLS (Nominal area) drawn through and including non metallic rigid PVC concealed conduit, medium grade, ISI marked not less than 20mm dia, concealed in wall, ceiling with GI saddles GI screws, rawl plugs (concealed conduit wiring) with all fittings including Tee, Junction boxes and provision of pressed steel terminal modular box with powder coating of suitable size for mounting switch/sockets and regulators and drawing continuous earth wire of PVC insulated unsheathed 1100 Volts grade cable with stranded copper conductor of size 1.5 Sq mm (Nominal area) complete all as specified and directed by Engineer-in-Charge. Note: Cost for cutting, chasing and making good to existing surfaces and cost of Modular metal flush box are deemed to be included in the Quoted rate.
All as per item No 2.02 above for one light point controlled by one SP switch
All as per item No 2.02 above for one fan/exhaust fan and wall mounted fan point controlled by one SP switch.
All as per item No 2.02 above for one light point controlled by two 2 - way SP switches
All as per item No 2.02 above for one bell point controlled by one number bell push
All as per item No-2.02 above but for one 3 pin socket out let, 6 Amps on same board with the cable 1.5 Sqmm size.
All as per item No-2.02 above but for one 3 pin socket outlet, 6 Amps on Independent board with the cable 1.5 Sqmm size.
All as per item No 2.02 above but with 2.5 Sq mm cable for Independent board one 3 pin 15 Amps socket outlet including S/C 2.5 Sq mm PVC insulated copper conductor unsheathed 1100 v grade IS -694 FRLS cable for continuous earth wire connected to box of required size all as specified and directed by Engineer-in-Charge.
All as per item No 2.02 above but with 4 Sqmm cable for independent board one 3 pin 15 Amps socket outlet including S/C 4 Sqmm PVC insulated copper conductor unsheathed 1100 v grade IS -694 FR LS cable for continuous earth wire connected to box of required size all as specified and directed by Engineer-in-Charge.
S&F Modular switch one way 6A, one modules suitable for 240 volt AC Complete all as specified and directed by Engineer-in-Charge.
S&F Modular Socket, 6A - 2/3 pin combined two module, suitable for 240 volt AC Complete all as specified and directed by Engineer-in-Charge.
S & F Modular switch two way 6A, one modules suitable for 240 volt AC Complete all as specified and directed by Engineer-in-Charge.
S&F Modular switch one way, 16A, one modules suitable for 240 volt AC Complete all as specified and directed by Engineer-in-Charge.
S&F Modular Socket, 16A - 2/3 pin combined two module, suitable for 240 volt AC Complete all as specified and directed by Engineer-in-Charge.
Supply and fix Modular bell push one Module, 5 Amps, suitable for 240 volt Complete all as specified and directed by Engineer-in-Charge.
Supply and fix bell AC 240 volt ding dong type complete, all as specified and directed by Engineer-in-Charge.
S&F modular electronic fan regulator rotary flush step type 120 watt, 240 volt complete .
Supply and fix white cover plate with frame, two module Complete all as specified and directed by Engineer-in-Charge.
Supply and fix white cover plate with frame, three module Complete all as specified and directed by Engineer-in-Charge.
Supply and fix white cover plate with frame, four module Complete all as specified and directed by Engineer-in-Charge.
Supply and fix white cover plate with frame, six module Complete all as specified and directed by Engineer-in-Charge.
Supply and fix white cover plate with frame, eight module Complete all as specified and directed by Engineer-in-Charge.
Supply and fix metal clad socket single pole and neutral sheet metal enclosure with 20A earth plug and socket compete with one single pole MCB 20A 240 Volts all as specified and directed by Eng-in-Charge.
Supply and fixing of ceiling roses, surface bakelite 65x50mm 3 terminals , PVC/Polycarbonate, isolated body fixed on PVC round block complete all as specified and directed by Engineer-In- Charge.
Supply and fixing wall mounted LED batten extruded aluminium heat shrink provided for efficient heat dissipation and integrated electronic driver ,20 watt LED fitting with tri colour 6500/4500/6500 K, 100 lumen/watt, 230 Volts, diffused optics ,etc complete with all accessories , connecting up with twin core twisted flexible copper conductor cable from ceiling rose to fitting, and testing complete all as specified and directed by the Engineer- In- Charge.
S&F LED light fitting 10 watt provided with high output diffuser 2 ft long, suitable for 120 volts to 270 volts of system efficacy not less then 90 lumen/watt, complete with all accessories, pre-wired including lamp and providing flexible copper wire, twin core cable complete all as specified and directed by Engineer-in-Charge.
S &F LED wall mounted light with decorative wall bracket luminaire suitable for 20 W including providing flexible copper wire, twin core cable complete all as specified and directed by Engineer-in-Charge.
S&F wall mounted LED bulk head fittings, 10 watt, warm white 230 Volts, diffused optics, etc complete wth all accessories, connecting up wth twin core twisted flexible copper conductor cable from ceiling rose to fitting, and testing complete all as specified and directed by Engineer-in-Charge.
Supply and fixing LED security light fitting 35 watt high pressure dia cast aluminium housing and secondary optical lens for superior light distribution , heat resistant thoughened glass with frame, IP66 protection complete with lamp & connected item and connection with suitable cable from ceiling rose to light fitting and fixing on GI bracket made out of suaitable GI Pipe medium garde 1.2 mtr long bent to shape and fixed on wall with flat iron clamps, nuts bolts washer etc all as specified and directed.
Taking down including disconnecting the electric connection of ceiling fan and dismantling blades,greasing and painting the whole assembly including marking MES No complete all as specified and directed
Hanging / fixing only ceiling fan received from above and connecting up including fastner and provision of suitable size of copper cable from connector of fans to ceiling rose complete.
S&F exhaust fans AC single phase 230/240 V of size 300 mm sweep with louver complete, all as specified and directed by Engineer-in-Charge. .
M&L for taking down existing geyser carefully without damaging of any capacity from bathroom and to be kept in safe custody untill completion of finishing work and re-fixing the same after completion of finishing work including cleaning the geysers and marking MES No, connecting,testing complete all as specified and directed by Engineer-in-Charge.
M & L for in replacement submain wiring with two run of 6.0 sqmm single core PVC insulated but unsheathed FRLS cable of specified size of multistranded copper conductor 1100 volts grade IS:694 marked and one run of 6.0 sqmm PVC insulated but unsheathed FRLS cable for earth continuty conductordrawn through and under suitable size of rigid non metallic PVC conduit , medium grade, ISI marked ( not less than 20 mm dia) complete with all acessories and fittings all laid/fixed concealed in wall/ceiling or surface in wall and surface conduit on ceiling, and also include the specified runs of specified size earth continuity conductor of similar type cable complete all as specified - two Runs of 6.0 Sqmm single core and one run of 6.0 sqmm single core cable.complete all as specified and as directed by Engineer-in-Charge.
M & L for in replacement submain wiring with two run of 4.0 sqmm single core PVC insulated but unsheathed FRLS cable of specified size of multistranded copper conductor 1100 volts grade IS:694 marked and one run of 4.0 sqmm PVC insulated but unsheathed FRLS cable for earth continuty conductordrawn through and under suitable size of rigid non metallic PVC conduit , medium grade, ISI marked ( not less than 20 mm dia) complete with all acessories and fittings all laid/fixed concealed in wall/ceiling or surface in wall and surface conduit on ceiling, and also include the specified runs of specified size earth continuity conductor of similar type cable complete all as specified - two Runs of 4.0 Sqmm single core and one run of 4.0 sqmm single core cable.
Taking down unserviceable submain wiring of aluminium two runs of any size cable including batten/conduit complete etc and making good disturbed surfaces complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement load line vertical distribution board 'A' frame made out of CRCA sheet,double door, surface mounting TPN 6 way 415 volts 200 Amps rated bus bar and stove enamels dust and vermin proof suitable forTP/FP 'A' frame MCCB of 125 Amps =01 No MCB for outgoing comlete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement MCB distribution board with Bus bar 200A neutral link , earth bar made out of CRCA mild steel sheet surface mounting SPN 8 way 230 volts double door type regal gray horizontal type complete all as specified and as directed by Engineer-in-Charge.
Taking down old unsv MCB DB of any sizecomplete, all as specified and directed by Engineer-in-Charge.
M&L for earthing complete with GI earth plate electrode 60cmx60cmx6.3mm thick buried directly in ground (earth pit not less than 2.25 meter deep below normal ground level) with top edge of the plate not less than 1.5 meter below normal ground level, connected to and including galvanized iron strip 4 mm dia as earth lead by means of GI bolts, nuts, check nuts and washers earth pit surrounded by picked layer of coal dust and 15 mm thick mixture in equal ratio of magnesium sulphate & copper sulphate in all around bottom and top and watering pipe 20mm bore of GI medium grade with funnel all as shown in electrical plate NO 5 of SSR Part I (1991) and connecting to earthing test point, including CI cover, frame and PCC (1:3:6) type C-2 using 20mm graded stone aggregate as in earthing pit with CI cover and framing including necessary earth work etc, complete all as specified Note :- 1. PCC chamber shall be constructed at least one meter away from building shall be provided in slanting manner complete, all as specified and directed by Engineer-in-Charge. 2. PCC pit cover shall be precast of RCC 1:2:4 type B-I 80 mm thick reinforced with XPM weighting not less than 4 Kg (sqm in lie of CI).
M&L in replacement of earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc as required 4 mm dia galvanized iron or steel wire complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of fixed thermal and fixed magnetic settings, 3 pole MCCB 100 Amps, 50 HZ, 415 volts with rupturing capacity 16 KA complete all as specified and directed by Engineer-in-charge.
Taking down the existing electric energy meter from cubicle type, meter box indoor type after disconnecting and depositng to MES Store complete all as required.
Fabricated,supply, install and commissioning cubicle type, meter box, indoor type, totally enclosed,dust & vermin proof (protection class IP43) made out of MS angle iron frame work, MS flat iron and CRCA sheet of 2.0 mm thick as per IS5039 duly painted with powder coated paint of approved shade. The meter box shall be suitable for accomodating 13 NOs single phase LT electric energy meter in an independent cubicles with fibre glass of suitable size fixed on front side of the cubicles to view the meter readings. The panel shall be suitable to be mounted on wall with suitable fixing arrangement. Each cubicles shall have openings for entry and exit of cables and locking arrangements. Refixing the existing meter (13 Nos) in the meter box complete all as specified and directed by Engineer-in-charge.
Taking down the defective cubicle type meter box with electric meter,indoor type with all connections and keeping in safe custody for giving credit to the contractor and keeping in safe custody the existing meter for refixing complete all as specified and directed by Engineer-in-charge.
Taking down unserviceable SP/SPN MCBs of any capacities from the MCCB DBs /MCB DBs after disconnecting the electric supply, complete all as specified and directed by Engineer-in-charge.
M&L taking down serviceable SP/SPN MCBs carefully without damaging of any size from various specifications from corridor/passages and rooms and to be kept in safe custody until completion of finishing work and re-fixing the same including cleaning and connection testing complete all as specified and directed by Engineer-in-charge.
S&F MCB SP 6 to 32 Amps 10 KA, 240 volt 'C' Series all as specified and directed by engineer-in-charge.
S&F MCB SP 40 Amps 10 KA, 240 volt 'B' Series all as specified and directed by engineer-in-charge.
S&F MCB SPN 40 Amps 10 KA, 240 volt 50 HZ 'C' Series all as specified and directed by engineer-in-charge.
Baljeet Builders & Interior Decorators
Rishi Constructions
Skyline Encon
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .