Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.3 LAccepted-AOC 705 646 MALVIA NAGAR ALLAHABAD UP PIN 211003 | PRAYAGRAJ | UTTAR PRADESH | 211003 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹35.4 L+₹44,132.73 (1.26%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹38.6 L+₹3.6 L (10.2%)Rejected-Finance | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹38.6 L+₹3.6 L (10.3%)Rejected-Finance 2ND 6 KEDIA HOUSE MA ROAD BYELANE 1 REHABARI GUWAHATI ASSAM 781008 | KAMRUP METRO | ASSAM | 781008 | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹39.0 L+₹4.0 L (11.4%)Rejected-Finance | L5 | Rejected-Finance Other than lowest bidder |
Tender Value
₹45.5 L
EMD Value
₹91,100
Closing Date
18 Nov 2022, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Bamrauli
GE (AF) Bamrauli
PROVN OF EXTERNAL FINISH IN HQ CAC BUILDING AT NORTH CAMP AT AF STATION BAMRAULI
2022_MES_553566_2
8752/E8
Open Tender
Civil Works
Works
180 days
GE (AF) Bamrauli
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE (AF) Bamrauli
₹91,100
Yes
13 Dec 2022
29 Oct 2022
19 Nov 2022
29 Oct 2022
18 Nov 2022
5 Nov 2022
Amount
Taking down cement or cement lime plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc., all as specified and directed.
Demolition of cement concrete (reinforced) in roof , floors (other than ground floor) , beam stair cases, landing , chajjas and similar supended works all as specified and as directed.
M&L for rendering 15mm thick on faces of brick work or concrete surfaces finished even and smooth without using extra cement in CM 1:4, all as specified and directed.
M&L water proofing compound make dr Fixit or equivalent all as specified and directed.
M&L for rendering 5 mm thick on ceiling surfaces of brick work or concrete surfaces finished even and smooth without using extra cement in CM 1:3 as in ceiling, all as specified and directed.
M&L for rendering 10 mm thick on ceiling surfaces of brick work or concrete surfaces finished even and smooth without using extra cement in CM 1:3 as in chajja/ceiling, with necessary scafolding all as specified and directed.
M&L wall care putty white 1.50 mm thick (to achieve smooth surface) for new plaster surface of wall complete. all as specified and directed.
M&L Complete removal of existing treatment on wall surface and applying wall care putty white 1.50 mm thick (to achieve smooth surface) complete all as specified and directed.
M&L Complete removal of existing treatment on ceiling surface and applying wall care putty white 1.5 mm thick (to achieve smooth surface) complete all as specified and directed.
S&F Formwork to chullah hoods, chajjas trought and similar items including edges all as specified and directed.
S&F Mild steel round bars 10mm dia and over, cut to length, bent to shape required, including ranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips Fe-410-W (Gde.E-250)Part- I quality-A orFe 290 (Gde -E-165
M&L for reinforcement cement concrete type B-1 (1:2:4) 20mm graded aggregate for chajjas all as specified and directed.
M&L for preparation of old painted surfaces, finishing walls with Acrylic Smooth weather proof exterior emlusion paint of required shade one coat applied @ 1.67 ltr/10 sqm over approved shade of colour obtain smooth finish etc by using spray machine/roller brushes complete all as specified and directed.all as specifed and directed.
M&L for finishing walls with Acrylic Smooth weather proof exterior emlusion paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) approved shade of colour obtain smooth finish etc by using spray machine / roller brushes complete all as specified and directed.
Taking down chowkats with shutters not exceeding 1.5 Sqm each (without taking off shutters from the frames). all as specified and directed.
Taking down chowkats with shutters not exceeding 1.5 Sqm each (with taking off shutters from the frames). all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) exceeding 1.5 Sqm but not exceeding 4 Sqm each. all as specified and directed.
M&L for MS work as in as in grills / Guards bars fillets for securing wire mesh and similar articles and hold fost, including demolition complete all as specified and directed.
S&F Aluminium (powder coated) frame for sliding windows, side hung windows and ventilators with necessary joining cleats, fastner etc to fix in existing opening complete Notes : (i) Thickness of powder coating (epoxy polyster) shall not be less than 50 micron. (ii) Shade/tint of powder coating (epoxy polyster) shall be as approved by GE. (iii) Gaps between frame and masonary/cill/lintel to be filled with silicon gel for water tightness. (iv) Rates quoted includes making good of jambs, soffits and cills etc.
M&L for aluminium window (Powder coated ) two track with anodized aluminium frame sliding/openable including wheel powder coated of section 62.5x37x2.5 mm thick shutter with bottom & middle rail of section 112.5x37x2.5mm and style & top rail of section 83x37x2.5mm thick with centrally locking arrangement with lock rail of rebate including joints cleat fixing of builders hardware fittings necessary and gazing with 5.0mm thick ordinary plain glass including wire mesh shutter necessary fittings fixuters & aluminium snap beads complete. Notes : (i) Glass filling in panels to windows shall be measured and paid for separately under respective item of this schedule as supply only (ii) Thickness of powder (epoxy polyster) coating shall not be less than 50 micron (iii) Shade/tint of powder coating (epoxy polyster) shall be as approved by GE. (iv) Frame shall be measured under respective item of this schedule
M&L for aluminium window (Powder coated ) three track with anodized aluminium frame sliding/openable including wheel powder coated of section 62.5x37x2.5 mm thick shutter with bottom & middle rail of section 112.5x37x2.5mm and style & top rail of section 83x37x2.5mm thick with centrally locking arrangement with lock rail of rebate including joints cleat fixing of builders hardware fittings necessary and gazing with 5.0mm thick ordinary plain glass including wire mesh shutter necessary fittings fixuters & aluminium snap beads complete. Notes : (i) Glass filling in panels to windows shall be measured and paid for separately under respective item of this schedule as supply only (ii) Thickness of powder (epoxy polyster) coating shall not be less than 50 micron (iii) Shade/tint of powder coating (epoxy polyster) shall be as approved by GE. (iv) Frame shall be measured under respective item of this schedule.” (v) Stainless steel wire cloth measured and paid for separately under respective item of this schedule.
S&F powder coated anodized aluminium grill powder coated shall be provided with minimum thickness 5.2 mm and weight of 2.4 KG/Sqm with 65x5 mm aluminium section having square gap of 100 mm thick with rail of channels 12-15 mm. Complete all as specified and directed.
S&F Stainless steel (Grade S-304) wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples
Supply only 5.0 mm thick tint glass/pin head type for aluminium ventilators / window etc. complete, all as specified and directed
Taking up or down steel tubing and connections, 15 mm bore complete all as specified and directed.
Taking up or down steel tubing and connections, 20 mm bore complete all as specified and directed.
M&L for Tubes, 15 mm bore 'medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed
M&L for Tubes, 20 mm bore 'medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
S&F in repair PVC (SWR) pipes 110mm bore single socketed in any length with rubber ring joints fixed to wall or laid in floors. complete all as specified and directed.
All as per item No. 29 as above but 75mm bore. complete all as specified and directed.
S&F 110mm bore PVC (SWR) bends, of any radius provided without access door. complete all as specified and directed.
All as per item No.31 as above but 75mm bore. complete all as specified and directed.
Demolition of brickwork built in any type of mortar, complete all as specified and directed.
M&L for brickwork with sub class 'B' bricks, straight or curved on plan exc 6m mean radius built in CM 1:6, complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises,
M&L Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match in floor etc set and jointed in neat cement slurry and pointed in white as coloured cement to match over and including 15mm thick screed bed in cement mortor (1:6) complete all as specified and directed
Demolition of concrete of any description and in any position not otherwise specifically provided for cement concrete reinforced.
M&L for cement concrete 50 mm thick 1:3:6 type C-1 ( using 20mm graded stone aggregate), in plinth protection laid in bays not exceeding 2 Sqm each and finishing even and fair on top without using extra cement with 6mm wide joints throughout the thickness of plinth protection in concrete bays all as specifed and directed.
M&L for Providing, cement concrete type B1 (1:2:4) 20mm thick stone aggregate in roof kerbs or mud stops, rounded or chamfered on edges , in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, ll as specified and directed.
S&F composit Panel 5mm thick with necessary fitting all as specified and directed by engr-in-charge
S&F powder coating anodised aluminium partion wall with frame size 101.60 x 44.45 x 2.00 mm thick and shutter aluminium anodised an top rail 47.62 x 44.45 x 1.50mm style 47.5 x 44.5 x 1.50 mm lock rail 83.5 x 44.45 x 1.50 mm and bottom rail 150.00 x 44.50 x 2.50 mm with 5 mm thick plain glass including lock and necessary fitting and fixture complete all as specified and directed.
M&L power coated anodised aluminium doors (sliding/ hanging type) with frame size 101.60 x 44.45 x 2.00 mm thick and shutter aluminium anodised and top rail 47.62 x 44.45 x 1.50 mm style 47.5 x 44.5 x 1.5mm, lock rail 83.50 x 44.45 x 1.50 mm and bottom rail 150.00 x 44.50 x 2.50 mm including necessary aluminium fittings like aluminium butt hinges 04 Nos, aluminium handle 150mm 02 Nos, aluminium tower bolts 200 mm 01 No, aluminium door stopper 01 Nos, jointing cleats glazing cleats, rubber packing, anodised aluminium tower bolts 200 mm 01 No, aluminium door stopper 01 Nos, jointing cleats glazing cleats, rubber packing, anodised aluminium shape beading screws etc with panelling in two parts with 12 mm thick prelaminted particle board in lower panel and 5 mm thick tinted glass in upper panels including all fittings & fixture complete all as specified and directed.
S&F Linoleum 2 mm thick, plain coloured, laid dry in floors including stretching, cutting and fitting and sealed down with an approved adhesive complete all as specified and directed.
Taking down carefully existing LT cable of any size rom roof/wallrefixing the same by proper camps with wall or in DLP trunking system/Ducts complete as directed by Engr-in-Charge.
M&L for sub main wiring with 2 run of single core PVC insulated and PVC Unsheathed, multistranded copper condutor of nominal area 6 sqmm FRLS, 1100 Volts grade cable drawn into and including rigid PVC Conduit including all fittings and one run of PVC insulated and PVC unsheathed, multistranded copper conductor of nominal area 6 sqmm FRLS 1100 volts grade cable continuous earth wire of green colour code complete including taking down old sub main wiring. Note:- (a) Two runs of 6.0 sqmm cable and one run of 6 Sqmm cable as earth lead with conduit shall be measured as one unit length for payment. (b) Quoted rate shall deem to be included cost of cutting chasses in wall for concealling conduit and making good to match with existing finish.
Supply and fix MCB DB SPN 12 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete all as directed by Engineer -in- Charge.
Supply and fix MCB DB TPN 8 way Horizontal, IP - 43 Protection double door 415 V AC 50Hz with for MCB Triple pole and neutral as incomer and SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete all as directed by Engineer -in- Charge.
Supply and fix MCB DB TPN 4 way Horizontal, IP - 43 Protection double door 415 V AC 50Hz with for MCB Triple pole and neutral as incomer and SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete all as directed by Engineer -in- Charge.
Supply and fix MCB DB SPN 4 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete all as directed by Engineer -in- Charge.
S&F in repair MCCB, four pole, 100 Amp rating, 25 KA ultimate breaking capacity , 415 Volt ,adjustable type fixed in DBs catered here-in-before.
S&F in repair MCB, SP, 6 to 32 Amp rating, 230 volt, 10 KA, 'C' series fixed in DBs catered herein before.
S&F in repair MCB, SP, 35 to 63 Amp rating, 230 volt, 10 KA, 'C' series fixed in DBs catered herein before.
S&F in repair MCB, SPN, 35 to 63 Amp rating, 230 volt, 10 KA, 'C' series fixed in DBs catered herein before.
S& F 2x2 occupancy sensor based recess mounted 36 watt 240 volts 50 Hzs 150 watt/lumens based high trasmitive diffuser suitable for indoor spaces aluminuim housing.
S&F LED Tube rod fittings in built sensor based 4 feet long surface / wall mounted LED batten extruded aluminium housing provided for efficiant heat dissipation with polycarbonate diffuser and intigrated electronic driver 20 watt including tube rod.
S & F DLP-S PVC trunking system and accessories of size 50x80 mm one compartment with complete fixing accessories , bends internla/external partion cover etc.
M&L for Repair/servicing /clenaing of trunking bus bar incl replacement of copper connector tightening of nuts bolts and reassembling the same after rectifying the fault.
M&L for Shifting and refixing of split type AC units of any make and any type after servicing and charging of gas (M410a/R134a/R-22/r32) by testing the leakage in system and repairing of leakage if any by gas welding work, cleaning and flushing out the complete system with gas, supply and replacing of drier/filter, making the complete system leak proof, vacuuming the system as existing and testing etc complete all as specified & directed. Note :(a) Dismantling and refixing of split AC are including in quoted rate. (b)Drier capillary,copper tubing,refrigernt gas,Insulation and LDPE pipe are inclusive in quoted rate.(c) making hole and filling the hole & Make good the disturbed surface with existing colour matching are inclusive in quoted rate.
S&F copper tubing of dia1/2" incl insultion with heavy duty foam for copper tubing and brazing work for discharge and suction of gas as per requirement and directed.
S&F copper tubing of dia1/4" incl insultion with heavy duty foam for copper tubing and brazing work for discharge and suction of gas as per requirement and directed.
S&F copper tubing of dia5/8" incl insultion with heavy duty foam for copper tubing and brazing work for discharge and suction of gas as per requirement and directed.
S&F copper tubing of dia 3/8" incl insultion with heavy duty foam for copper tubing and brazing work for discharge and suction of gas as per requirement and directed.
M&L for Earthing complete with galvanised steel earth plate electrode 60 x 60 cm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised iron wire 4mm dia as earth lead wire by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in Electrical plate No. 3, MES SSR Part I- 2009 with 15 mm dia medium grade GI pipe as a protection to earthing lead and 20 mm dia medium grade GI pipe for watering purpose including excavation & earth work in any type of soil, funnel, wire mesh, RCC pit with cover, cast iron frame complete and connected to earthing test point all as specified or indicated including testing on completion. Notes (i) The concrete pit shall be PCC (1:3:6) type C-1, 40mm thick precast cover slab of RCC with suitable Mild steel handle in lieu of cast iron cover shown in electrical plate No 3 of MES SSR Part-I (ii) PCC pit shall be provide at least 500 mm away from the earth pit and not on just on the eath pit and extra cost of additional length of water pipes and fittings junction etc shall be deemed to be included in the rate. (iii) Item includes the cost of 7.5 metre earth lead wire and GI pipe for protection of earth wire. Any varriation in quantity shall be adjusted.
M&L for earthing complete with GI electrode 600x 600 x 6mm, thick buried directly in ground vertically in a pit of depth not less than 2.25 mtr below normal ground level (with top edge of earth plate not less than 1.50 mtr below normal ground level connected to GI strip 32x6mm as earthing lead by means of bolt nuts, check nuts, and washers of brass connected including gun metal or phosphorus bronze of sixe 75x75x25mm drilled and screwed including 3 Nos 8mm dia 25 mm long hexagonal head screwed all as specified including excavation and earth work and disposal of surplus soil incl 40 mm GI tubing light grade and necessary fitting for protection of GI strip incl laying of alternate layer of charcoal dust and common salt PPC (1:2:3) type C-1 (using 20mm graded stone aggregate) for earth pit with 40 x 40 x 6mm MS angle iron frame for cover 40 mm thick (1:2:4) type B20 using 12.5 mm graded stone aggregate reinforced with 8 mm dia round bar @ 75mm C/C both way with MS handle 20mm dia plastering 15mm thick CM (1:6) internally and upto 150mm below ground level externally PGL funnel with ground wire mesh 20mm dia GI pipe Medium grade for watering complete all as shown on electrical plate No 3 of SSR Part-1 2009 and connected in earth test incl testing completed all as specified and directed. Note:- Galvanised strip and protection light grade GI pipe upto 7.5 mtr shall be deemed to be in the rates.
S&F 25X3 mm copper strip on surface or in recess for connection etc incl both end termination , suitablesize strip clamps etc from equipment to the earth pit termination / earth test link.
S&F 25X3.15 mm aluminium strip on surface or in recess for connection etc incl both end termination , suitablesize strip clamps etc from equipment to the earth pit termination / earth test link.
Taking down existing copper/aluminium earthing strip and refixing the same alongwith epoxy based insulator on wall roof.
Note :- Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items of this schedule. The same shall be recovered from various payment to contractor before handing over old material.
M/S JAI DURGA CONSTRUCTION
M.R. ENTERPRISES
Aditi Construction Company
Abhinav Builders
Agrawal Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .