Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.4 LAccepted-AOC | L1 | Accepted-AOC L1 bidder | |
| 2 | L2₹2.4 L+₹5,746.02 (2.43%)Rejected-Finance AT EKATALI NEAR SADAR PS JHARSUGUDA PIN 768216 | JHARSUGUDA | ODISHA | 768216 | L2 | Rejected-Finance Bidder is not L1 | |
| 3 | L3₹2.7 L+₹30,867.62 (13.1%)Rejected-Finance AT RANGIAMUNDA PO TANGARPALI DIST SUNDARGARH ODISHA | KENDRAPARA | ODISHA | 754217 | L3 | Rejected-Finance Bidder is not L1 | |
| 4 | L4₹3.0 L+₹65,336.60 (27.7%)Rejected-Finance 2ND FLOOR BLOCK B C 4 BALAJI HERITAGE SAKHIPADA SAMBALPUR ODISHA PIN 768001 | SAMBALPUR | SAMBALPUR | ODISHA | 768001 | L4 | Rejected-Finance Bidder is not L1 |
Tender Value
₹2.8 L
EMD Value
₹3,500
Closing Date
4 Nov 2024, 5:00 pmClosed
HOD ENM
HOD ENM CMPDI RI VII
Supply and installation of electrical fittings, point wiring and other accessories in D-6 quarter for establishment of office at exploration camp of CMPDI RI VII, orient area.
2024_CMPDI_319324_1
CMPDI/RIVII/BBSR/ENM/2024/4308
Open Tender
Electrical and Maintenance Works
Item Rate
60 days
Jharsuguda, odisha
Please refer Tender documents.
9 documents required · 9 mandatory
₹3,500
11 Dec 2024
19 Oct 2024
5 Nov 2024
19 Oct 2024
4 Nov 2024
19 Oct 2024
19 Oct 2024 - 26 Oct 2024
Amount
Supplying and fixing 12 way , Double door single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
Supplying and fixing 6 way , Double door single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
Supplying and fixing 63 A rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of Single pole and neutral (SPN) in the existing MOB DB complete with connections, testing and commissioning etc. as required.
Wiring for circuit/ submain wiring alongwith earth wire with the2 X 6 sq. mm + 1 X 6 sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
Wiring for circuit/ submain wiring alongwith earth wire with the2 X 4 sq. mm + 1 X 4 sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
Wiring for circuit/ submain wiring alongwith earth wire with 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
Wiring for circuit/ submain wiring alongwith earth wire with the 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.- Group A
Supplying and fixing 3 pin 5/6 A socket outlet piano type switch/ socket on the existing switch box/cover including connections etc. as required.
Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A piano type switch, connections,painting etc. as required
Supplying and fixing brass batten/ angle holder including connection etc. as required.
Supplying and fixing of ACCL SPN (Mains rating 6000W & DG rating 4000W) including connection etc as required.
Supplying and fixing of 20W indoor LED tube light fitting including connection etc as required.
Supplying and fixing of 9W indoor LED Bulb fitting including connection etc as required.
Supplying and fixing of 3pin, 5 Amps. Ceiling rose on the existing junction box/metal box including connection etc as required.
Supplying and fixing of 25W outdoor LED street light fitting including connection etc as required.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Total impact of GST for the purpose of CTC
S/H ENTERPRISES
GOURI BIDYUT CONSTRUCTION
NILADHRI POWER & CONSTRUCTIONS
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .