| 1 | L1₹8.1 LAdmitted-Finance | ₹8.1 L | L1 | Admitted-Finance |
| 2 | L2₹9.6 L+₹1.5 L (19.1%)Admitted-Finance | ₹9.6 L+₹1.5 L (19.1%) | L2 | Admitted-Finance |
| 3 | L3₹10.6 L+₹2.5 L (31.1%)Admitted-Finance | ₹10.6 L+₹2.5 L (31.1%) | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | IMPLA GENERAL SUPPLIERS L3 | A One Engineers L1 | Salafia Electricals L2 |
|---|---|---|---|---|---|---|
| 1.00Stablilization and improvement of 33KV Noubugh Chadoora Line | ||||||
| 2.00 | Supply and Erection of 11 Mtr. Long Steel Tubular Pole with welded steel base plate (of Designation ST-410 SP56) and top cap including excavation of pit and back filling by boulders as per REC construction Standard (with latest amendments if any). | 15 | No | 26,400 ₹3,96,000 | 26,000 ₹3,90,000 Lowest | 35,500 ₹5,32,500 |
| 3.00 | Providing and fixing of fabricated GI V cross arm with top bracket, Channel X-arm including belting, clamps and braces angle iron as per site reqirement. | 750 | Kg | 130 ₹97,500 Lowest | 130 ₹97,500 Lowest | 130 ₹97,500 Lowest |
| 4.00 | Providng,Laying,stringing ,tensioning and binding of 200 Sqmm ACSR Conductor as per REC construction standard (with latest amendments if any). | 0.4 | Kms | 3,50,000 ₹1,40,000 | 2,20,000 ₹88,000 | 1,50,000 ₹60,000 Lowest |
| 5.00 | Providing and fixing of PG Clamps for 200 mm² ACSR Conductor. | 18 | No | 200 ₹3,600 Lowest | 300 ₹5,400 | 200 ₹3,600 Lowest |
| 6.00 | Supply,installation,testing and commissioning of 33 kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm | 45 | No | 850 ₹38,250 | 800 ₹36,000 Lowest | 950 ₹42,750 |
| 7.00 | Supply,installation,testing and commissioning of 33 kV Polymeric composite Disc Insulator 36KV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm with fitting | 12 | No | 400 ₹4,800 | 850 ₹10,200 | 200 ₹2,400 Lowest |
| 8.00 | Supply,installation,testing and commissioning of 33 KV isolator with Earthing blades (36 kv,800A,Out door,3 pole,25 KA) | 1 | SET | 55,000 ₹55,000 Lowest | 60,000 ₹60,000 | 95,000 ₹95,000 |
| 9.00 | Providing and fixing of Gavanized Nuts & Bolts with washers of sorts as per site requirements. | 30 | Kg | 130 ₹3,900 Lowest | 150 ₹4,500 | 165 ₹4,950 |
| 10.00 | Providing and fixing of Danger Plates with clamps of standard make | 15 | No | 200 ₹3,000 Lowest | 200 ₹3,000 Lowest | 500 ₹7,500 |
Tender Value
₹9.3 L
EMD Value
₹18,597
Closing Date
7 Aug 2026, 4:30 pmClosed
Executive Engineer, STD-II, Rajbagh,Srinagar
Office of the Executive Engineer, STD-II, Rajbagh
Stablilization and improvement of 33KV Noubugh Chadoora Line
2026_PDD_315220_1
eNIT No. STD-II / 49 of 2026-27 Dated 04-07-2026
Open Tender
Electrical Works
Turn-key
Budgam
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Executive Engineer, STD-II, Rajbagh,Srinagar
₹18,597
14 Aug 2026
9 Jul 2026
10 Aug 2026
9 Jul 2026
7 Aug 2026
9 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Stablilization and improvement of 33KV Noubugh Chadoora Line | - | - | - | - |
| 2 | Supply and Erection of 11 Mtr. Long Steel Tubular Pole with welded steel base plate (of Designation ST-410 SP56) and top cap including excavation of pit and back filling by boulders as per REC construction Standard (with latest amendments if any). | 15 | No | - | - |
| 3 | Providing and fixing of fabricated GI V cross arm with top bracket, Channel X-arm including belting, clamps and braces angle iron as per site reqirement. | 750 | Kg | - | - |
| 4 | Providng,Laying,stringing ,tensioning and binding of 200 Sqmm ACSR Conductor as per REC construction standard (with latest amendments if any). | 0.4 | Kms | - | - |
| 5 | Providing and fixing of PG Clamps for 200 mm² ACSR Conductor. | 18 | No | - | - |
| 6 | Supply,installation,testing and commissioning of 33 kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm | 45 | No | - | - |
| 7 | Supply,installation,testing and commissioning of 33 kV Polymeric composite Disc Insulator 36KV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm with fitting | 12 | No | - | - |
| 8 | Supply,installation,testing and commissioning of 33 KV isolator with Earthing blades (36 kv,800A,Out door,3 pole,25 KA) | 1 | SET | - | - |
| 9 | Providing and fixing of Gavanized Nuts & Bolts with washers of sorts as per site requirements. | 30 | Kg | - | - |
| 10 | Providing and fixing of Danger Plates with clamps of standard make | 15 | No | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.49 MB
Tendernotice_2.pdf
PDF • 1.60 MB
BOQ_1021796.xls
BOQ • 0.26 MB
ext1.pdf
PDF • 0.38 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .