GE AF LOHEGAON
GE AF LOHEGAON LOHEGAON PUNE-411032
REPAIR AND REPLACEMENT AND MAINTENANCE,OF DEFECTIVE ITEMS OF INTERNAL ELECTRIFICATION, FLAME PROOF LIGHT FITTINGS COMPREHENSIVE MAINTENANCE AND MISC ITEM AT 9BRD AFS PUNE AND REPAIR, REPLACEMENT AND MAINTENANCE, OF DEFECTIVE ITEMS OF AIRFIELD CABL
2023_MES_627977_1
8752
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
GE AF LOHEGAON
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE AF LOHEGAON
₹96,000
Yes
5 Feb 2024
11 Nov 2023
18 Dec 2023
11 Nov 2023
11 Dec 2023
25 Nov 2023
Amount
Taking down the existing surface batten type point wiring of aluminium for Light, fan, Sockets, power sockets, stair case light point complete with switch socket regulator , bracket fitting etc and making good disturbed surfaces for wall, floors etc as directed by Engr- in charge.
Taking down cearfully by unscrewing the unserviceable DB Boxes, MC distribution boards SP & TPN with porcelain cutouts etc all as directed.
Taking down the sub main wiring of any dia / sq mm on teak wood batten / PVC conduit GI earth wire all as directed.
Material and labour for providing point wiring with two runs of 1.5 Sqmm multi stranded copper conductor FRLS PVC insulated single core 1100 volts grade & with one run of 1.5 Sqmm single core multi stranded copper conductor FRLS PVC insulated 1100 Volts grade wire for continuous earthing complete in and including PVC casing and caping with all fittings/fixture etc and open recessed type Plastic Enclosure( Plastic Switch Board ) ISI Marked (IS:14772) for housing switches / sockets all a specified and directed
(a) One light point controlled by one switch .
(b) One Fan point controlled by one regulator/switch.
c) One two way point controlled by two 2 way switches
(d) One 3 pin socket 5 A on independent board.
(e) One 3 pin socket 5 A on the same switch board.
(f) One bell point controlled by one bell switch.
Material and labour for providing point wiring with two runs of 2.5 Sqmm multi stranded copper conductor FRLS PVC insulated single core 1100 volts grade & with one run of 2.5 Sqmm single core copper stranded FRLS PVC insulated 1100 volts grade wire for continuous earthing complete in and including PVC casing and caping with all fittings / fixture etc and open recessed type Plastic Enclosure (Plastic Switch Board) ISI marked for housing one 15 A Switch / sockets all a specified and directed
M/L for sub main wiring with two runs of single core 1.5 Sq mm FRLS PVC insulated unsheathed multi stranded copper conductor 1100 V grade with colour code and one run of 1.5 Sq mm single core FRLS PVC insulated unsheathed multi stranded copper conductor green colour cable for continuous earthing complete in & including PVC casing & caping with all fttiing & fixtures all as directed and specified. (Note:- Two runs of 1.5 Sqmm copper cable & one run of 1.5 sqmm copper cable including PVC casing & caping shall be mesured and paid as one length)
M/L for sub main wiring with two runs of single core 2.5 Sq mm FRLS PVC insulated unsheathed multi stranded copper conductor 1100 V grade with colour code and one run of 2.5 Sq mm single core Flame retardan PVC insulated unsheathed multi stranded copper conductor green colour cable for continuous earthing complete in & including PVC casing & caping with all fttiing & fixtures all as directed and specified. (Note:- Two runs of 2.5 Sqmm copper cable & one run of 2.5 sqmm copper cable including PVC casing & caping shall be mesured and paid as one length)
M/L for sub main wiring with two runs of single core 4.0 Sq mm FRLS PVC insulated unsheathed multi stranded copper conductor 1100 V grade with colour code and one run of 4 Sq mm single core Flame retardan PVC insulated unsheathed multi stranded copper conductor green colour cable for continuous earthing complete in & including PVC casing & caping with all fttiing & fixtures all as directed and specified. (Note:- Two runs of 4 Sqmm copper cable & one run of 4 sqmm copper cable including PVC casing & caping shall be mesured and paid as one length)
M/L for sub main wiring with two runs of single core 6.0Sq mm FRLS PVC insulated unsheathed multi stranded copper conductor 1100 V grade with colour code and one run of 6.0 Sq mm single core FRLS PVC insulated unsheathed multi stranded copper conductor green colour cable as earth continuity conductor drawn in & including casing & caping all as directed and specified . ( Note:- Two runs of 6 Sqmm copper cable & one run of 6 sqmm copper cable including PVC casing & caping shall be measured & paid as one length )
M/L for sub main wiring with two runs of single core 10.0Sq mm FRLS PVC insulated unsheathed multi stranded copper conductor 1100 V grade with colour code and one run of 10.0 Sq mm single core FRLS PVC insulated unsheathed multi stranded copper conductor green colour cable as earth continuity conductor drawn in & including casing & caping all as directed and specified . ( Note:-Two runs of 10 Sqmm copper cable & one run of 10 sqmm copper cable including PVC casing & caping shall be measured & paid as one length )
S&F Sub main wiring with 4 X 4 sqmm single core cable PVC insulated unsheathed of copper multi strandard conductor cable , 1100 votls grade drawn in PVC casing caping and including PVC casing caping and insulated 1X 4 sqmm unsheathed multistranded FR-LS copper conductor cable for earth continuity and connected to common earth dolly complete all as specified and directed by Engineer-in-charge. (Note:- 4 lengths of 4 Sqmm & 1 length of 4 sqmm cable and PVC casing caping will be measured as one length).
S&F of Sub main wiring with 4 X 6 sqmm single core cable PVC insulated unsheathed of copper multi strandard conductor cable , 1100 votls grade drawn in PVC casing caping and including PVC casing caping and insulated 1X 6 sqmm unsheathed multistranded FR-LS copper conductor cable for earth continuity and connected to common earth dolly complete all as specified and directed by Engineer-in-charge. (Note:- 4 lengths of 6 Sqmm & 1 length of 6 sqmm cable and PVC casing caping will be measured as one length).
S&F of Sub main wiring with 4 X 10 sqmm single core cable PVC insulated unsheathed of copper multi strandard conductor cable , 1100 votls grade drawn in PVC casing caping and including PVC casing caping and insulated 1X 10 sqmm unsheathed multistranded FR-LS copper conductor cable for earth continuity and connected to common earth dolly complete all as specified and directed by Engineer-in-charge. (Note:- 4 lengths of 10 Sqmm & 1 length of 10 sqmm cable and PVC casing caping will be measured as one length).
S&F of Sub main wiring with 4 X 16 sqmm single core cable PVC insulated unsheathed of copper multi strandard conductor cable , 1100 votls grade drawn in PVC casing caping and including PVC casing caping and insulated 1X 16 sqmm unsheathed multistranded FR-LS copper conductor cable for earth continuity and connected to common earth dolly complete all as specified and directed by Engineer-in-charge. (Note:- 4 lengths of 16 Sqmm & 1 length of 16 sqmm cable and PVC casing caping will be measured as one length).
Supply and fix switch piano flush type 5 Amp one way.
Supply and fix Socket out let 2in 1, 5 pin 5 Amp
Supply and fix switch socket combination 5 A, 2 in 1, flush type.
Supply and fix switch socket combination 5 / 16 A, 5 in 1, flush type.
Supply and fix switch piano flush type 15 Amps complete all as specified and directed.
Supply and fix Socket out let 2 in 1, 3 pin 5 and 15 Amps complete all as specified and directed.
Supply and fix switch piano flush type 5 Amp two way.
Supply and fix Piano switch bell push type switch 5 A.
Supply and fix bell electric 230V single pole complete as directed.
S/F Fan Regulator electronic step type 100 W complete as directed
S&F angle / batten holder insulated body with back plate for batten fittings
Supply and fix ceiling rose surface type bakelite / PVC three terminal 65 x 50mm.
Supply and fix high quality indoor Surface and wall mounted batten suitable for 20 Watt T8 Tube rod 4 feet long , including LED retrofit Tube rod 20 Watt T8 Tube rod 4 feet long 6000K colour temperature with extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver with industrial grade heavy duty driver having THD<10%. complete with all accessories internally pre-wired and including connecting up with three core 0.5 Sqmm flexible copper conductor cable ceiling rose to fitting terminal.
Supply and fixing LED mirror light fitting 10 Watt 2 feet long including electrical connections complete as directed.
S & F Recessed mounted LED down lighter with electronic driver 21 Watt powder coated aluminium housing with integrated electronic driver complete Iincluding making all nacessary arragement to fix and connection as required on site complete all as specified and directed.
S & F Recessed mounted LED down lighter with electronic driver 18 Watt complete Iincluding making all nacessary arragement to fix and connection as required on site complete all as specified and directed.
Supply and fix in replacement electronic driver for recess mounted LED panel fitting 36 Watt suitable for 2x2 grid in roof including electronic connections and testing as directed.
Supply and fix Energy efficient recess mounted LED panel fitting 36 Watt suitable for 2x2 grid in white colour with high quality diffuser for uniform light & high Efficiency. Made from CRCA sheet, Pre-coated white color. Separate replaceable electronic driver, lumen constant of 6000K colour temperature with current electronic connections as directed including 2 core wire upto ceiling rose complete.
Supply & fix LED street light fitting Energy saving and environmental friendly long life LED street light fittings 35 Watt made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having IP65 protection and Impact resistance of IK07 with 10KV Built-in Surge Protection Device The light fittings shall be fixed on pole/bldg with complete all as specified and.
S&F Vertical double door Distribution board TPN 4 way with busbar consisting of MCCB. 100A 10KA - 1 NO complete including connecting LT cable and outgoing submain wiring etc and testing complete all as specified and directed by Engr-In-charge.
Supply and fix sheet metal enclosure MCB DB double door SPN 12 way 230 V with neutral link and connecting to wiring complete all as specified and directed by Engr-In-charge.
Supply and fix sheet metal enclosure MCB DB double door SPN 8 way 230 V with neutral link and connecting to wiring complete all as specified and directed by Engr-In-charge.
Supply and fix sheet metal enclosure MCB DB double door SPN 4 way 230 V with neutral link andand connecting to wiring complete all as specified and directed by Engr-In-charge.
Supply and fix MCB SPN 240 V, 32 Amps. complete all as directed at site.
Supply and fix MCB SP 240 V ,6 to 32 Amps complete all as directed at site.
M/L for providing earthing complete with galvanised steel earth plate electrode 600 mm x 600 mm x 6mm thick buried directly in ground earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level connected to galvanised earth lead wire 4.00mm dia by means of bolts, nuts, checknuts & washers of GI or steel and connecting to earth dolly all as shown in electrical plate No. 3 of SSR Part I of 1991 & testing complete including 15mm dia light grade GI pipe upto 7.5mtr long, excavation in any type of strata, PCC ( 1:3:6 ) type C1 earthing chamber, pre cast slab 50 mm thick in cement concrete ( 1: 2 : 4 ) type B 1 ( reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg / Sqm with frame, test box , funnel, wire mesh with GI watering pipe etc.
Taking down ceiling fan single phase 240 V 1200 mm /1400mm sweep from the existing position including disconnecting supply cable from ceiling rose / connector opening ceiling fan carefully and taking out worn out/defective spare parts such as bearing/ bush shaft , blades, split pin condenser rubber reel nuts and bolts and washer etc cleaning and washing the bearings /bushs thoroughly and applying necessary lubricants etc and reassembling of ceiling fan after replacement of wornout parts and hanging in original position connecting and testing complete all as directed by Engr - in - Charge [Note :- Replacement of spares for ceiling fan shall be measured and paid seperately]
All as per item No 46 above but for exhaust fan 300 / 450 mm sweep
All as per item No 46 above but for wall mounting fan any sweep
Supply and fix ball bearing 6201
Supply and fix ball bearing 6202
Supply and fix ball bearing 6203
S&F Gunmetal bush
Supply and fix capacitor 2.5 Mfd /3.15 mfd
Supply and fix capacitor 4 Mfd
Supply and fixing PVC unsheathed 3 core cable copper flexible wire 0.5 Sqmm size
M&L for rewinding of ceiling fans of 1200 / 1400 mm sweep with suitable size of copper winding wire of same gauge & number of turns complete with insulation all as directed by Engineer-in-Charge.
M&L for rewinding of exhaust fans of 300 / 380 / 450 mm sweep with suitable size of copper winding wire of same gauge & number of turns complete with insulation all as directed by Engineer-in-Charge.
M&L for rewinding of wall fans of 400 mm sweep with suitable size of copper winding wire of same gauge & number of turns complete with insulation all as directed by Engineer-in-Charge.
S&F fan clamp suitable for ceiling fan complete as directed.
S&F fan blade suitable for existing wall mounting fan / exhaust fan/ Ceiling fan 1200mm complete as directed
Taking down Geyser 25/50 Ltrs from the existing position including disconnecting supply cable from connector opening geyser carefully and taking out worn out/defective spare parts such as Thermostat, appratus terminal plate, glass wool, element etc cleaning and reassembling of geyser after replacement of wornout parts and hanging in original position connecting and testing complete all as directed by Engr - in - Charge [Note :- Replacement of spares for geyser shall be measured and paid seperately]
Supply and fix thermostat suitable for geyser of any make and any size.
Supply and fix indicating neon lamps suitable for geyser of any make.
Supply and fix apparatus terminal plate assembly with provision of inlet and outlet copper tubing including nuts bolts and washers suitable for geyser of any type and any make as per site requirement.
Supply and fix PVC connecting pipe heavy duty 15 mm dia for inlet and outlet with brass coupling .
Supply and fix geyser element 250 V 2/1.5 KW suitable for 25/35/50 ltrs capacity.
Supply and fixing in replacement of Single pole and neutral sheet metal enclosure with a two pin and earth plug and socket, one single pole 20 Amps, 240V MCB complaints complete all as specified and directed
M&L for Carrying out day to day comprehensive maintenance of Technical area 9BRD Buildings] internal eletrification complaints by Collecting from complaints cell daily between 9.00 am to 10.00 am and repairs in situ or attending of complaints of domestic area. After rectification the specified complaint job card shall be returned on same date. Nature of defects such as repair/replacement of switches, fuse wires, DB, MCB (light/ power), Tube light, lamp holder (bracket, pandent, batten) bell/buzzer, push button, ceiling rose, capacitors and other similar electrical items/fittings, repairing of fan and geysers etc including providing electrical connection using pvc copper cable of size 1.5 sqmm to 10 sqmm single core/ two core and length not exceding 1.5 mtrs complete all as specified and directed. (Note :- any accessories as mentioned above found unserviceable shall be measured and paid separately under respective items of this Sch. However any minor requirement essential for making overall system serviceable is deemed to be included in the quoted rate of this item.) Note for Ser Item No : (i) Contractor shall provide his representative’s authorized contact No (i.e) Cell / Mobile no and local address to contact and communicate the message of any breakdown/complaint. Contactor’s representative shall visit the Office to collect day to day complaints of any nature/type. For essential services, Contractor’s representative shall be available 24x7 to attend complaint as called upon by Engr-in Charge. (ii) Penalty for not rectifying the defect in given time shall be charged to contractor at the rate of ₹100 per complaint from due payment of works/RAR/Final bill.Manpower requirement for attending and completing day to day complaints may vary day to day and cost of same shall deemed to be included in the quoted rate.Contractor is advised to quote accordingly. (iii) Complaints shall be treated as rectified only after production of user’s “Satisfactory Job Slip duly signed” to Engr-in-Charge. (iv) Old material obtained from replaced items under this item shall be contractor's property and shall be measured as Schedule of credit and shall be Issued to contractor . (v) Cost of minor spares i.e, insulation tape, lugs, thimbles etc are deemed to be included in the quoted rate. Labour required to carryout the maint / repairs including testing and commissioning shall be deemed to be included in item rate as quoted by the contractor.Items replaced shall be measured and paid seperately. (vi) Cost of T&P i.e, ladders, tools, brazing, welding, soldering required and transportation is deemed to be included in quoted rates. (vii) Making good the area / cleaning the area will be mandatory for the contractor & failing which penalty of Rs. 50/- shall be charged. (viii) Complaints of OTM Bldgs will be considered as one unit on replacement upto five accessories/rectifications upto five defects
S & F Modular switch 1 way 6A, 1 module matching to as existing on site complete all as specified and directed.
S & F Modular switch 1 way 16A, 1 module vmatching to as existing on site complete all as specified and directed.
S & F Modular Bell push 1 module, 5 amp matching to as existing on site complete all as specified and directed.
S & F Modular socket 6 A 2 module matching to as existing on site complete all as specified and directed.
S & F Modular socket 16 A 2 module matching to as existing on site complete all as specified and directed.
S & F Modular stepped Fan Regulator 120W 2 module matching to as existing on site complete all as specified and directed.
S & F modular cover plate with frame 4 module matching to as existing on site complete all as specified and directed.
S & F modular cover plate with frame 6 module matching to as existing on site complete all as specified and directed.
S & F modular cover plate with frame 8 module matching to as existing on site complete all as specified and directed.
S & F modular cover plate with frame 3 module matching to as existing on site complete all as specified and directed.
S & F PVC switch box for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 100 mm x 100 mm and 50 mm deep including screws, plastic plugs etc complete all as specified and directed.
Ditto all as per Ser Item No. 79.00 above but 175 x 100 x 50 mm complete all as specified and directed.
Ditto all as per Ser Item No. 79.00 above but 200 x 150 x 50 mm complete all as specified and directed.
Supply and fix exhaust fan, steel body heavy duty AC single Phase. 230V of size 450 mm sweep with, blades, and frame and louver complete all as specified and directed.
Supply and fix exhaust fan, steel body heavy duty AC single Phase. 230V of size 380 mm sweep with, blades, and frame and louver complete all as specified and directed.
Supply and fix exhaust fan, steel body heavy duty AC single Phase. 230V of size 300/230 mm sweep with, blades, and frame and louver complete all as specified and directed.
Supply and fix wall fan AC single Phase. 230V of size 400 mm sweep complete all as specified and directed.
Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300 mm complete all as specified and directed.
Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250 mm complete all as specified and directed.
S & F PVC Casing & Capping of size 25 mm width with connected accessories
Supply & fixing in replacement 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 meter apart including 4mm suspension wire one twin core cables stranded conductor flat or circular 6 Sqmm complete all as specified and directed.
Supply & fixing in replacement 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 meter apart including 4mm suspension wire one twin core cables stranded conductor flat or circular 10 Sqmm complete all as specified and directed.
Supply & replace 3 pin 15 Amps Plug Top 250 Volts heavy duty PVC complete all as specified and as directed.
Taking down carefully aluminum/copper Flame proof point wiring for light complete with fitting such as switches, tube lights, ceiling rose, MCB DB, MCB'S,Main switch from control board and making good disturbed surfaces of walls, floor to match with existing specification complete and all as specified.
M & L for Flame proof point wiring with 1.5 Sqmm 1100 volts grade PVC insulated FRLS copper conductor single core multi strand flexible cable with proper colour coding in and incl ERW rigid steel conduit & fittings (ISI marked) and accessories incl flame proof bends, copules junctions boxes etc fixed on wall/ceiling with proper fixing arrangements incl proper conductor 1.5 Sqmm PVC insulated unseathed multi stranded FRLS copper conductor single core cable (green color) as earth lead continuity conductor fixed to earth terminal and metalic body of light fittings complete all as suitable for one/two independent light point controlled by one way one switch all as specified and directed.
M&L for Flame proof submain wiring with two single core PVC insulated flexible copper conductor multistranded cable (FRLS) of size 4 sqmm with proper color coding and one single core PVC insulated flexible copper conductor multistranded cable green colour of size 4 Sqmm as earth lead in & incl ERW rigid steel conduit & fittings (ISI marked) and accessories incl flame proof bends, copules junctions boxes etc fixed on walls for laying conduit and making good the disturbed wall surfaces to match with existing specification all as required at site or directed by Engr-in- charge.
Supply an Fix CMRI certified LED flame proof tube light fitting 1 X 20/16 Watts, with driver & LED tube rod, IP 65 protection, including connecting up with three core flexible multi strand copper conductor of size 1.5 Sqmm with flexible metal conduit, including mounting brackets and Fixing including anchor fastners, nut bolts, hooks, chain etc.
Supply and Fixing of Flameproof cum Waterproof LED Bulk Head light fitting of 30W, IP66 protection of Cast Aluminum alloy material and Heat and Impact resistance toughen 'A' clear glass having Anti corrosive epoxy powder coated finish complete with all accessories pre wired and including connecting up with three core flexible copper conductor cable with suitable size including fixing using anchor fastners, nut bolts, hooks, chain etc. on ceiling or wall all as specified and directed by engr-In-charge.
Supply and fixingreplacement in CMRI certified explosion proof rotary switch, single pole ON/OFF with cable termination box in LM6, 16 Amps rating 240 volts all as specified and directed, including taking down of old unserviceable switch and connecting with existing cable & wire all as directed..
S& F in replacement Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 16A, 250V, 2P+earth rating 240 volts all as specified and directed, including taking down of old unserviceable switch and connecting with existing cable & wire all as directed..
S&Fix in replacement wall mounted outdoor type double door LT Panel made out of 3 mm thick CRCA Sheet, th panel shall comprise of flame proof MCB DB 8 Way made out of Cast aluminium alloy LM6, inside and out side light gray epoxy powder coating shade, with 1 No cable entry for incoming cable/submain wiring and three Nos cable/sub main entry for out going circuits with and including cable gland and stopping plug, 1 No MCB SPN 32 Amp as incoming and 6 Nos MCB SP 6 Amps for out going connections IP 65 protection as per IS 2147/1962. Including making good the distrubed surfaces, connecting existing cables all as direted at site Note - The contractor shall submit the Layout Drawing of Panel and got approved by GE before the panel fabrication
M&L for Attending E-N voltage complaints, checking the wiring circuit for attaining desired E-N voltage, including fine tuning isolation transformer connections , checking all incoming and outgoing circuits, cleaning and servicing of isolation transformer complete upto satisfaction of Engr-In-Charge. (Note : Any minor spare part found faulty during checking and cable lugs , minor wire pieces including cost of T&P, multimeter etc shall be included in quoted rates of this item)
S&F in replacement copper wound transformer for servo stablizer of rating 5KVA to 10 KVA as per existing winding including taking down old transformer and making connection of new transformer as per original and testing complete all as specified and directed
S&F in replacement copper wound transformer for servo stablizer of rating 15KVA to 20 KVA as per existing winding including taking down old transformer and making connection of new transformer as per original and testing complete all as specified and directed
M&L for Servicing of 3 phase/single phase servo stabliser upto 30KVA including checking of tap changer, servomotor, cleaning of winding coils, tightning incoming and outgoing connections, arresting any minor oil leakage, checking of dimmer, contact relay etc complete upto satisfaction of Engr-In-Charge. (Note : Any minor spare part found faulty during checking such as contact relay and cable lugs , minor wire pieces including cost of T&P, multimeter etc shall be included in quoted rates of this item)
Supply and fix MCB TPN 415 V, 32 Amps 10 KA C Curve in DB complete all as directed at site.
Supply and fix MCB TPN 415 V, 40 to 100 Amps 10 KA C Curve in DB complete all as directed at site.
M&L for painting of Ceiling fan 1200/1400 mm as per existing colour or opal white enamel paint using spray gun painting including fan blades, hanging rod, canopy etc carefully at site or contractors work shop complete all as directed and as specified by Engr-In-Charge.
Supply and fix in replacement Metal clad plug top 20 Amps rating with eath pin ISI marked in DB complete all as directed at site.
Supply and fix in replacement Metal clad socket 20 Amps rating with eath pin ISI marked in DB complete all as directed at site.
Supply and fixing front facia sheet of illuminated information guidance board fo runway, Taxilink. Front facia sheet shall be made out of 4 mm thick Polycarbonate sheet duly pasted with 3M HIP retroreflective sheet on front surfce. Details of information i.e letters, numbers, symbol, background cololurs to be painted in facia sheet alongwith size of each individvial facia sheet is enclosed in particular specification. Contractor has to submit coloured layout diagram of sinage board duly indicates letter size, Stroke width confirming to ICAO standared and shall be got approved from GE and user including opening of existing sinage board, removing old facia sheet and refixing the new facia sheet, including making good the distrubed area all as directed.
Supply, fixing, testing and commissioning of LED Driver suitable for Runway sinage board AMA LED module with the following specifications, Constant current range 2.8 - 6.6 Amp, Frequency range - 50 Hz, Power factor > 0.95, DC voltage Maximum 36 Volt, Maximum power 100 watts, working temperature - 40 to + 70 C and IP rate is IP 67 all as specified and directed at site.
Supply, fixing, testing and commissioning of LED module suitable for Runway illumination of the guidance sign with the following specification, LED hours (as per LM80 report) is 1,00,000 hrs, LED strip make AMA LEDM, LED Strip size 730 mm x 30 mm. Wattage 1/2 watt, No of LED in each strip 22 Nos, Output voltage is 36 volts, Operating current is 150 mA , operating wattage is 5.4 watt and operating temp of LED is < 85 C all as specified and directed at site.
Supply and fix in replacement of adhasive EPDM gasket 15 mm to 25 mm wide and of thickness 2 mm to 5 mm suitable for replacement of rubber gaskets of existing signage board installed for indicating at runway/taxilink etc all as specified and directed.
T.H.ASSOCIATES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .