CWE MAMUN
HEADQUARTERS CWE MAMUN PIN-145001
PROVN OF GUARD ROOM WITH TOILET AND CERTAIN SANCTIONED WORKS UNDER GE(N) MAMUN AT MAMUN MIL STN
2022_MES_570998_3
CWE/M-47/2022-23
Open Tender
Civil Works - Others
Lump-sum
270 days
GE (N) MAMUN
Class C a i
7 documents required · 7 mandatory
₹1,000
GE (N) MAMUN
₹1.3 L
15 Apr 2023
22 Mar 2023
12 Apr 2023
22 Mar 2023
10 Apr 2023
29 Mar 2023
Amount
NOTE: Schedule ‘A’ Part I to III under Ser No. 1.10 to 1.30 are Prepriced by MES.
Lump sum price worked out by the Contractor for “BUILDING WORK” as listed in Schedule ‘A’ Part-I
Lump sum price worked out by the Contractor for “B/R WORK” as listed in Schedule ‘A’ Part-II
Lump sum price worked out by the Contractor for “E/M WORK” as listed in Schedule ‘A’ Part-III
SCHEDULE `A' PART - IV MISC B/R & E/M ITEMS is not prepriced by MES and prepriced rates indicates 0.0 under column 6 signified this fact only.
Supply and fixing box type steel windows comprised of tubular frame and shutters made out of 1.25mm thick MS sheet tube factory made with double side shuters wire gauged shutter & glass glazed shutter (wire cloth and glass panes shall be measured and paid separately) with side hung shutters with steel handle and steel peg stay dovetailed or welded including 2 Nos tower bolts, 1500mm long for each leaf and 10mm square bar grills at spacing as shown on Drg welded to FI frame work, including other fittings, hinges, handles, tarred hold fasts, PCC blocks etc all as shown on Drg No CEPZ-TD-354/09 sheet 1/3 to 3/3 including two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Material & labour for Preparing new wall surface including making surface clean, dry and free from any loose paint film, dirt, chalk, grease, fungus and algae and applying two coats of acrylic antifungal emulsion exterior weather proof paint over primer on external surfaces, complete all as specified.
Supply and fixing of 25mm bore Mild steel powder coated, single curtain rod (wall thickness not less than 1mm) including fancy type PVC powder coated brackets, funnels etc suitable for single curtain rod etc complete all as specified and directed.
Material & labour for APP modified roof treatment over non-accessible RCC roof slab / chajjah / canopy / parapet wall to be executed through approved applicator of the membrane manufacturer with following specification complete all as directed :- (a) Cleaning existing surface properly. (b) Applying oil bound bitumen primer @ 0.30 liter/Sqm manufactured by the same agency as that of APP with a density 0.87-0.89 Kg per liter at 25 degree centigrade on prepared surface. (c) Laying not less than 3mm thick APP modified water proofing membrane weighing not less than 3.60 Kg/Sqm reinforced with non woven polyster fiber weight not less than 160gsm/Sqm using butane torch by torch application with 10cm side laps and 15cm end lap. Laying of membrane, Physical property of membrane shall be as under :- (i) Membrane weight not less than 3.60 Kg/Sqm. (ii) Non woven polyester weight not less than 160 gsm/Sqm. (iii) Softening point of membrane not less than 150 degree Celsius. (iv) Joint tensile strength-longitudinal not less than 650/Sqcm and transverse not less than 450/sqcm at 230 degree Celsius. (v) Tear strength - longitudinal not less than 300 N & transverse not less than 250N. (vi) Elongation of reinforcement not less than 30%. (vii) Impermeability under water pressure not less than 3 Kg/Sqcm. (d) APP membrane shall be laid using butane torch by Torch application with minimum 10cm side overlap and 15cm end lap. (e) Top of membrane shall be provide with solar reflective bituminous aluminum paint @ 0.1 Kg/Sqm as prescribed by manufacture of membrane.
Material & labour for LLDPE septic tank for 25 users designed to carry sewage and sullage water including excavation in any type of soil, PCC 1:4:8 for foundation, sand filling in side of LDPE tank, connection etc. complete all as specified and directed.
Supply & fixing Lamp holder, insulated body, with back plate for batten fittings including 12W LED lamp, complete all as specified and directed.
Supply & fixing MCB single pole (SP) 240 volts, 6 to 32 Amps, 10KA (C-series) complete all as specified and directed.
Supply & fixing MCB SPN 240V, 50Hz, 10 KA,of rating 32Amps complete all as specified and directed.
Supply and fixing Energy saving, surface mounted bulk head luminaire 10W made of pressure die cast aluminium housing with IP 65 protection complete including connecting up with cord flexible overall sheathed copper conductor cable of suitable size complete all as specified and directed.
Supply and fixing of 20W surface/wall mounted box type batten LED luminaire, extruded aluminium housing with PC diffuser and integrated electronic driver with high efficiency long life, CRI=80(Minimum), PF>0.95, luminous efficacy > 100 lumens/Watt operating voltage 140V-240V, colour temperature (CCT) = 5700 + 300K, THD < 10% complete with all accessories internally prewired and including connection up with cord flexible overall sheathed copper conductor cable of suitable size from ceiling rose to connector of LED fitting complete all as specified and as directed.
Supply and fixing of box type 10 Watt LED 2 feet length as mirror light with all accessories internally prewired and including connection up with cord flexible overall sheathed copper conductor cable of suitable size from ceiling rose to connector of LED fitting complete all as specified and as directed.
Supply & fixing sheet metal enclosure MCB distribution board. Single pole & neutral 240 volts 6 way with IP-43 IK-09 protection double door complete with appropriate size bus bar and neutral link fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed.
Material and labour for cutting and threading to existing 40mm bore GI pipe line in position for insertion of Tee, branches including fitting like tee etc., complete all as directed.
Material and labour for cutting and threading to existing 50mm bore GI pipe line in position for insertion of Tee, branches including fitting like tee etc., complete all as directed.
M/S NARESH KUMAR SHARMA
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .