| 1 | L1₹42.8 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹46.4 L+₹3.6 L (8.33%)Rejected-Finance 7TH MILE UPPER SHILLONG P O NONGLYER SHILLONG 793009 MEGHALAYA | EAST KHASI HILLS | MEGHALAYA | 793009 | L2 | Rejected-Finance Not lowest bidder | |
| 3 | L3₹46.5 L+₹3.6 L (8.44%)Rejected-Finance OPPOSITE GATE NO 2 NORTH BENGAL UNIVERSITY PO N B U DIST DARJEELING WB | DARJEELING | DARJEELING | WEST BENGAL | 734013 | L3 | Rejected-Finance Not lowest bidder | |
| 4 | L4₹46.8 L+₹3.9 L (9.17%)Rejected-Finance 100 GIRISH GHOSH ROAD DONBOSCO LILUAH HOWRAH WEST BENGAL 711202 | HOWRAH | WEST BENGAL | 711202 | L4 | Rejected-Finance Not lowest bidder | |
| 5 | L5₹46.8 L+₹4.0 L (9.23%)Rejected-Finance B 8 2ND FLOOR VIVEKANANDA SUPER MARKET HILL CART ROAD SILIGURI 734001 | SILIGURI | DARJEELING | WEST BENGAL | 734001 | L5 | Rejected-Finance Not lowest bidder |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
28 Nov 2022, 6:00 pmClosed
GE BENGDUBI
Bengdubi Military Station, PO-Bengdubi, Dist-Darjeeling, Pin 734424
REPAIR MAINT OF ELECTRIC GEYSERS FAN AND OTHER MISC E M WORKS FOR OTM MD ACCN UNDER AGE E M OF GE BENGDUBI MIL STN
2022_MES_561044_1
8397/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE BENGDUBI
MES Enlisted/ Un-enlisted contractor of D and above with category b(i)
8 documents required · 8 mandatory
₹500
GE BENGDUBI
₹90,000
Yes
13 Dec 2022
2 Nov 2022
30 Nov 2022
2 Nov 2022
28 Nov 2022
18 Nov 2022
3 Nov 2022 - 9 Nov 2022
Amount
Comprehensive repair/maintenance of storage type electric water heater (Geyser ) vertical or horizontal type of capacity 50 Ltrs comprising of the following :- (a) Inspection, taking down, opening or dismantling, de-scaling, brushing and thoroughly cleaning the storage tank. (b) checking of all stop cock, pressure release valves, fusible plugs for its serviceability etc. in situ to ensure free movement of the parts including supply and replacing the washers/gasket nut etc. (c) Checking and rectify earth continuity of the Electrical circuits of the Geysers and power point. (d) Checking thermostat and re-adjust. (e) De-scaling the immersion type heating element (f) Checking of indicator lamp for it serviceability . (g) Re-assembling the Geyser, re-install and testing complete. Note : Parts / components of geysers found unserviceable shall be replaced by the contractor. New parts/components required shall be measured and paid separately under item No 3.00 to item No 10.00 here-in-after as supply only and labour charges required for replacement are deemed to be included in the quoted rate.
All as per item No. 01 here-in-above but Geyser of capacity 25 ltrs complete all as specified and directed.
Supply only thermostat of Type EST 11 / 20A, 240 Volt of approved make and having complete all as specified and directed.
Supply only thermostat of Type EST 7 / 15A, 240 Volt of approved make and having complete all as specified and directed.
Supply only heating elements of capacity 2 KW AC 240 volts suitable for storage type electric water heater as per site requirement (press type /screw type/ triangular/ circular base or ceramic cartige type), complete all as specified and directed.
Supply only heating elements of capacity 1.5 KW AC 240 volts suitable for storage type electric water heater as per site requirement (press type /screw type/ triangular/ circular base or ceramic cartige type), complete all as specified and directed.
Supply only PVC insulated PVC sheathed flexible round stranded copper wire 2.5 sqmm, 3 core complete all as specified and directed.
Supply only safety valve suitable for 25 Ltr/50 Ltr geyser complete all as specified and directed.
Supply only Apparatus plate suitable for 50 ltrs capacity geysers.
Supply only Apparatus plate suitable for 25 ltrs capacity geysers.
Supply and fixing in replacement switch socket combination multipurpose 3 pin 15 amp flush type all as specified and as directed. Make:Anchor/Plaza/ Kinjal.
S & F plug top 3 pin, 16 amps complete all as specified and directed.
S & F plug top for earth plug socket C-Curve complete all as specified and directed.
S & F earth plug socket with top and MCB incl taking down old unserviceable one complete all as specified and directed.
S & F indicating lamp LED Neon type, 240 volt AC suitable for 25/50 ltrs capacity Geyser complete all as specified and directed.
S & F chromium plated connecting pipe for hot water/cold water of length upto 60cm long, including two connecting nut with gasket and connecting up complete all as specified and directed.
S & F PVC connecting pipes with brass adapter 450mm long complete all as specified and directed.
S & F non return valve any size as per site requirement complete all as specified and directed.
S & F of wall anchor bolt fastner rust proof rawal bolt, brass type, size 10 x 70 cm for mounting the geyser complete all as specified and directed.
Taking down and checking of ceiling fan/exhaust fan/wall fan any type and any size at site on daily basis after disconnecting the electrical connection including replacement of unserviceable spares parts with new parts , lubricating with approved grade of grease and necessary minor work (if required) and refixing the fan in same position including all electrical connection Note : i) New spare parts required shall be measured and paid separately . ii)Labour cost for replacing spare parts are deemed to be inclusive in the quoted rate.
Taking down carefully ceiling fan any sweep and any make after disconnecting the electrical connection, dismantling the blades and removing fan incl blades to the work shop for Rewinding including cleaning and dismantling the fan into parts and segregation of unserviceable parts, replacement of unserviceable spares parts with new parts including necessary machining work and lubricating with approved grade of grease and necessary minor soldering work (if required) and re-assembling the fan , testing and refixing the fan in same position including all electrical connection and material and labour for replacement of two nos split pins, one connection block and one rubber reel all as specified and as directed. Note : i) Rewinding work of armature shall be measured and paid separately. ii) New spare parts required for replacing old burn out parts shall be measured and paid separately. iii)Labour cost for replacing spare parts are deemed to be inclusive in the quoted rate.
Material and labour for taking out and removing burnt copper winding, cleaning the armature, rewinding the fan armature for 1200mm sweep fan with new super enamelled copper wire of existing gauge including supply and fixing necessary insulating materials etc and varnishing with approved grade of insulation varnish and heating up and testing all as specified and as directed.
All as pr item No.22 above but for 1400mm sweep ceiling fan all as specified and as directed.
Taking down carefully Exhaust Fan any sweep and any make after disconnecting the electrical connection, dismantling the blades and removing fan incl blades to the work shop for Rewinding including cleaning and dismantling the fan into parts and segregation of unserviceable parts, replacement of unserviceable spares parts with new parts including necessary machining work and lubricating with approved grade of grease and necessary minor soldering work (if required) and re-assembling the fan , testing and refixing the fan in same position including all electrical connection and material and labour for replacement of two nos split pins, one connection block and one rubber reel all as specified and as directed. Note : i) Rewinding work of armature shall be measured and paid separately. ii) New spare parts required for replacing old burn out parts shall be measured and paid separately. iii)Labour cost for replacing spare parts are deemed to be inclusive in the quoted rate.
Material and labour for taking out and removing burnt copper winding, cleaning the armature, rewinding the fan armature for upto 300 mm sweep exhaust fan with new super enamelled copper wire of existing gauge including supply and fixing necessary insulating materials etc and varnishing with approved grade of insulation varnish and heating up and testing all as specified and as directed.
All as pr item No.25 above but for above 300mm and upto 450 mm sweep Exhaust fan all as specified and as directed.
Material and labour for painting of ceiling fans complete of any sweep and any make with one coat of first quality synthetic enamell paint of approved tint by spray including preparation of old painted surface and removing all dust, oil mark etc and filling cavaties with filler materials,and writing serial / MES number as specified (with paint of black colour with each letters/figures in Block of height n.exc2 cm ) complete all as specified and as directed.
All as per item no-27 above but for painting to exhaust fans with blade complete of any sweep/make all as specified and as directed.
Supply only bearing No.6201/6202 for ceiling /Exhaust fan (Make - TATA/SKF/NBC/HCH ).
Supply only bearing No.6203/6204 for ceiling/ Exhaust fan (Make - TATA/SKF/NBC/HCH ).
Supply only fan condensor 3.15 mfd oil filled .(Make - USHA/UNIVERSAL/Havells/Tibcon}.
Supply only fan condensor 3.15 mfd dry type .(Make - USHA/UNIVERSAL/Havells/Tibcon}.
Supply only fan condensor 2.5 mfd oil filled (Make - USHA/UNIVERSAL/Havells/Tibcon).
Supply only fan condensor 2.5 mfd dry type (Make - USHA/UNIVERSAL/Havells/Tibcon).
S & F electronic fan regulator socket type(step 0-5).MAKE ANCHOR/HAVELLS/CROMPTON
S & F electronic fan regulator switch type (step 0-5).MAKE ANCHOR/HAVELLS/CROMPTON
S & F in replacement Modular Regulator Step Type 100 watt, 2 module complete all as specified and directed by Engineer-in charge.
Supply only gun metal bush of any size complete all as specified and directed.
Supply only mounting clamp assembly complete for ceiling fan 1200mm/1400mm sweep brass type with amp,bolt,nut,washers, safety/ split pins and rubber bush and all as specified and as directed.
Supply only down rod complete suitable for any type any size of ceiling fan complete all as specified and as directed.
Taking down carefully Wall Fan any sweep and any make after disconnecting the electrical connection, dismantling the blades and removing fan incl blades to the work shop for Rewinding including cleaning and dismantling the fan into parts and segregation of unserviceable parts, replacement of unserviceable spares parts with new parts including necessary machining work and lubricating with approved grade of grease and necessary minor soldering work (if required) and re-assembling the fan , testing and refixing the fan in same position including all electrical connection and material and labour for replacement of two nos split pins, one connection block and one rubber reel all as specified and as directed. Note : i) Rewinding work of armature shall be measured and paid separately. ii) New spare parts required for replacing old burn out parts shall be measured and paid separately. iii)Labour cost for replacing spare parts are deemed to be inclusive in the quoted rate.
Material and labour for taking out and removing burnt copper winding, cleaning the armature, rewinding the fan armature for wall fan of any size with new super enamelled copper wire of existing gauge including supply and fixing necessary insulating materials etc and varnishing with approved grade of insulation varnish and heating up and testing all as specified and as directed.
Material and labour for flexible multi stranded copper wire twin twisted two core of size 0.75sqmm all as specified and as directed.(Make:Havells/Plaza/Polycab)
S & F aluminium based fan blade (set of 3 nos.) suitable for any type any size of fan with nut bolt complete all as specified and directed.
S & F ceiling fan canopy as per existing size complete all as specified and directed.
S&F MS type hook suitable for any type any size of ceiling fan all as specified and as directed.
Excavation of trenches in soft/loose soil n.exc 1.5 metre wide and n.exc 1.5 metre depth and getting out complete all as specified and directed.
Returning filling in approved earth, including spreading leveling watering and well ramming in layers not exceeding 25cm in soft/loose soil complete all as specified and directed
Removing of excavated surplus soil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.50metre above the starting point complete all as specified and directed.
Taking out old U/S underground LT cable of any size, any position from trenches, floors and walls, complete all as specified and directed.
Supply, laying,testing and commissioning XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables ( heavy duty) with stranded aluminum conductor, 1100Volt grade with fixing acessories of 6 Sqmm, 2 Core complete all as specified and directed.
All as per item No. 51 here-in-before but size of cable 10 sqmm, 2 core
M&L for sand cushioning (dry) in trenches for protection of UG cables (below, above and around the cable laid in trenches) of 230mm spreding thickness and consolidated ( punned) upto 180mm thickness complete all as specified and as directed.
M&L for horizontal boring under the road below 1 mtr from the road surface and dia of hole not exc 100 mm without damaging the existing road getting out and disposal of soil to a distance not exceeding 50 m from the site of work complete all as specified and as directed.
S&F in repair of GI pipe 50 mm light grade including all necessary fittings to poles/laid under road through boring for protection of under ground cable including making good the disturb surfaces complete all as specified and directed.
S&F in repair of GI pipe 40 mm light grade including fittings to poles/laid under road through boring for protection of under ground cable including making good the disturb surfaces complete all as specified and directed.
Supply & laying Sub-Class old size B Bricks, well burnt, laid breadth wise along the length of cable laid in trenches over sand cushion for UG cable protection complete all as specified and directed.
Laying only old serviceable brick as in cable protection retrived from taking out of cable complete all as specified and directed.
Relaying of serviceable cable retrieved from item No 50 detecting the fault and making straigth through jointing kit of LT 440 volt under ground system of LT feeder/location of size 6 Sqmm 2 core to 16 Sqmm 2core complete all as specified and directed.
Relaying of serviceable cable retrieved from item No 50 detecting the fault and making straigth through jointing kit of LT 440 volt under ground system of LT feeder/location of size 10 Sqmm 4 core to 95Sqmm 3.5core complete all as specified and directed.
S&F in repair/replacement of energy saving, environmental friendly, long life, pressure die-cast aluminium housing with toughened glass with IP66 protection street light with high power LEDs as light source connecting and testing LED street lights of 60 watts capacity complete all as specified and directed.
All as per item No.61 here-in -before but of 45 Watts capacity.
Supply and fixing in repair/replace of energy saving, environmental friendly, long life, pressure die-cast aluminium housing with IP66 protection flood light with high power LEDs as light source connecting and testing LED flood lights of 200 watts capacity complete all as specified and directed by the Engr-in-charge. Make : Make : Orient/Indiabulls/Havells/Crompton
All as per item No. 63 above but of 120 W capacity LED Flood light
M&L for 3 core cable 1.5 sqmm FRLSH PVC insulated copper conductor weather proof in existing surface/ recessed/on pole complete all as specified and directed.
M&L for PVC conduit pipe medium grade 20mm dia (ISI Marked) including necessary clamps, nuts, bolts etc. as required complete all as specified and directed.
S&F in repair street light bracket made out of GI tubing 32 mm bore medium grade 1.50 Mtr long bend to required shape as in bracket for street light fittings fixed with two pair or MS flat iron 50mm x 6mm size and 30cm long clamp of required shape with bolts nuts and washers suitable for steel tubular pole including painting of mild steel flat iron surfaces with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. Make: Tata/Jindal/BST
Cutting and trimming of tree branches, bushes n.exc 5 Mtr girth all along HT/LT overhead lines/guard wire and removing branches out of defence land complete all as specified and directed.
M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to galvanised iron earth lead wire 4.00 mm dia by means of bolts, nuts, checknuts and washers of galvanised iron or steel, GI earth wire protected by 15mm bore light grade GI pipe and other end connected to earthing test point or main switch board as directed including funnel with watering pipe of 20mm bore light grade GI, wire mesh, charcoal or coke and common salt in alternate layer of 15cm compacted thickness all around the earth electrode PCC (1:3:6) type C-1 earth pit, cast iron cover and frame, including necessary excavation and earth work and refilling of black soil good conductor of earth and necessary testing complete all as specified and directed and shown on electrical plate No 3 of MES Schedule Part I
M&L for preparation of old rusted steel surface of LT steel tubular swaged pole (of any length upto 9 mtr) and applying one coat of black synthetic enamel paint upto 1.2 mtr height as per the existing pattern above the PCC coping and one coat of aluminium paint beyond 1.2 mtr height (for the rest portion) including cross arms brackets and re-writing pole numbers and and cutting vegetation growth all around the pole upto 1 mtr radius complete including replacement of self adhesive fluorescent colour tape as per existing pattern and size complete all as specified and directed
M&L for preparation of surfaces by scrapping of PCC poles of any length and applying two coats of weather coat paint black in colour upto 1.2 mtr height as per the existing pattern above the PCC coping and applying two coats of weather coat paint crimson colour includng applying alluminium paint to cross arms brackets and re-writing pole numbers and cutting vegetation growth all around the pole upto 1 mtr radius complete including replacement of self adhesive florescent copor tape as per existing pattern and size complete all as specified and directed
S&F MCCB 100 Amps, 4 pole,415 Volt adjustable type with breaking capacity 16 KA, and 100 % Icu including spreader terminals and connected acessories complete all as specified and directed.Make: Legrand/L&T/Havells/HPL
S&F MCCB 63 Amps, 4 pole,415 Volt adjustable type with breaking capacity 16 KA,and 100 % Icu including spreader terminals and connected acessories complete all as specified and directed.Make: Legrand/L&T/Havells/HPL
S&F 1100 volts grade heavy duty cable 4.0 sqmm PVC insulated stranded aluminum conductor served with inner sheathing of PVC tape and overall PVC sheathed for service connection suspended by insulating hangers not more than 1 mtr apart including 4mm dia suspension wire one twin core cable flat or circular type including taking out unserviceable one complete all as specified and directed.
All items as per Ser No 74 here-in-before but 6 Sqmm
All items as per Ser No 74 here-in-before but 10 Sqmm
M&L for surface dressing averaging 15cm depth in soft/loose soil for cleaning and cutting /removal of green vegetation in and around the installations and removal of the soil outside of the installation including spreading thin layer of anti vegetation chemical to prevent abnormal growth of grass/bushes complete all as specified and directed.
S&F in replacement of junction box made of thermoplastic, IP 66 of size 205mm x 255mm x 112mm consisting of 4 Nos terminal on porceline support inside enclosure,5 way insulated fo cable glands (incl locknut) with MCB SP 6 Amps and using 40 x 6mm size MS clamps of required shape & size with bolts, nuts & washers and making connection by providing suitable size of lugs / binding and testing directed complete all as specified and directed. Make : Hensel /C&S/BCH
Labour only for finding fault in ACSR Conductor including jumpper/wire in street light feeder and remove the carbon in jumper or Street light service wire complete all as specified and directed.
M&L for taking out the loop of any size of cable and checking the cable thoroughtly including cleaning and taking out defective porting including necessary excavation/ earth work and making connection by providing suitable size of lugs/binding and testing and reconnect the cable to the electrical equipment complete all as specified and directed.
M&L for lowering of high mast carriage carefully from 20 mtr high structure for repairing light luminaries and raising latern carriage after repairing the light luminarises and adjust to its proper postion serving to winch mechanism pulleys steel wire ropes end terminal of SWR and greasing drain gearbox oil and toping up complete all as specified and directed.
S&F in repair Digital timer switch , surface mounting complete all as specified and directed.
S&F analog timer 20 Amps rating for automatic operation of street light complete all as specified and directed
S&F in repair contactor modular type with ON/OFF indicator and label holder 4 pole 230 V 40-63 Amps coil operating voltage 230 volt complete all as specified and directed.
S&F in repair contactor modular type with ON/OFF indicator and label holder 3 pole 230 V 40-63 Amps coil operating voltage 230 volt complete all as specified and directed.
Schedule of Credit refer Srl Page No 31 of the Subject Tender
S K ENTERPRISE
M/S Vaishno Constructions
M/S R. K. INDUSTRIES
TECHNOSOFT
M/S POWER ENGINEERS
NEO BUILDERS
SRI A B SEN
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .