Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1st₹74.5 LAccepted-AOC SHOP NO 4 SUN STAR CHS LTD PLOT NO 309 SECTOR 21 NERUL EAST NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | ₹74.5 L Quoted ₹76.1 L | 1st | Accepted-AOC M/s Paramatama Enterprises is L1 bidder being accepted |
| 2 | 2nd₹78.9 L+₹2.9 L (3.79%)Rejected-Finance ROOM NO 220 2ND FLOOR DEVGIRI BUILDING NO 65 B LALLU BHAI COMPOUND MANKHURD MUMBAI 400043 | MUMBAI SUBURBAN | MAHARASHTRA | 400043 | ₹78.9 L+₹2.9 L (3.79%) | 2nd | Rejected-Finance Not being L1 |
| 3 | 3rd₹80.1 L+₹4.1 L (5.33%)Rejected-Finance B 12 VISHAKARMA JYOTI SUBHASH LANE MALAD E MUMBAI 400097 | MUMBAI SUBURBAN | MAHARASHTRA | 400097 | ₹80.1 L+₹4.1 L (5.33%) | 3rd | Rejected-Finance Not being L1 |
| 4 | 4th₹85.8 L+₹9.8 L (12.8%)Rejected-Finance F 402 AMBIKA APARTMENT PLOT A 9 SECTOR 20 NERUL W NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | ₹85.8 L+₹9.8 L (12.8%) | 4th | Rejected-Finance Not being L1 |
| 5 | 5th₹87.4 L+₹11.3 L (14.9%)Rejected-Finance 302 SIDDHIVINAYAK APPT A WING MUMBAI K K MARG JACOB CIRCLE MUMBAI CITY MAHARASHTRA 400 011 | MUMBAI | MAHARASHTRA | 400011 | ₹87.4 L+₹11.3 L (14.9%) | 5th | Rejected-Finance Not being L1 |
| Sl No | Description | Qty | Unit | mp construction co L2 | Parmatma Enterprises L1 | Vishal Builders L3 | the bhimani group of companies L5 | OM INFRA L7 | Advait Enterprises L4 | LUCKY DECOR L6 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Demolition of brick work built in cement mortar including all quoins, arches, pillars, PCC coping etc, but excluding ashlar facings, dressed stonework and precast concrete articles and removing of debris outside MD land complete all as specified and as directed by Engineer-in-Charge. | 3 | Cum | 200 ₹600 Lowest | 300 ₹900 | 500 ₹1,500 | 200 ₹600 Lowest | 499 ₹1,497 | 500 ₹1,500 | 200 ₹600 Lowest |
| 2.00 | M&L for brick work with sub class 'B' bricks straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and as directed. | 2 | Cum | 3,900 ₹7,800 | 700 ₹1,400 Lowest | 8,500 ₹17,000 | 9,000 ₹18,000 | 6,500 ₹13,000 | 5,000 ₹10,000 | 4,900 ₹9,800 |
| 3.00 | M&L brick work with sub class 'B' bricks, straight or curved on plan to any radius in 1/2 brick thick walls, built in cement morter 1:4 complete all as specified and as directed. | 20 | Sqm | 700 ₹14,000 Lowest | 700 ₹14,000 Lowest | 900 ₹18,000 | 800 ₹16,000 | 1,200 ₹24,000 | 1,000 ₹20,000 | 1,600 ₹32,000 |
| 4.00 | Demolition cement concrete (unreinforced) in ground floors and pavings not exc 15 cm thickness (below or above ground level), including tiles complete all as specified and directed. | 15 | Cum | 200 ₹3,000 | 300 ₹4,500 | 700 ₹10,500 | 500 ₹7,500 | 600 ₹9,000 | 500 ₹7,500 | 190 ₹2,850 Lowest |
| 5.00 | Dismantling of wrought iron or mild steel work of any description not otherwise provided for | 10 | Qtl | 10 ₹100 Lowest | 200 ₹2,000 | 500 ₹5,000 | 500 ₹5,000 | 1,000 ₹10,000 | 500 ₹5,000 | 190 ₹1,900 |
| 6.00 | Dismantling of Asbestos Cement corrugated sheet in roof coverings | 355 | Sqm | 1 ₹355 Lowest | 5 ₹1,775 | 10 ₹3,550 | 40 ₹14,200 | 30 ₹10,650 | 10 ₹3,550 | 30 ₹10,650 |
| 7.00 | M&L for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. | 3,500 | Kg | 100 ₹3,50,000 | 100 ₹3,50,000 | 110 ₹3,85,000 | 135 ₹4,72,500 | 120 ₹4,20,000 | 95 ₹3,32,500 | 85 ₹2,97,500 Lowest |
| 8.00 | M&L preparing new steel surfaces of any description, over 10 cm in width or girth, and applying two coats of synthetic enamel paint over a coat of red oxide primer. | 200 | Sqm | 80 ₹16,000 | 80 ₹16,000 | 75 ₹15,000 | 120 ₹24,000 | 120 ₹24,000 | 110 ₹22,000 | 60 ₹12,000 Lowest |
| 9.00 | S&F pre-painted galvalum aluminium zinc coated GI based colour corrugated steel sheet 0.5mm thick of any colour having tensile strength of 550 mpa as in wall cladding and roof fixed with self tapping screws as per manufacturers instruction/recommendations complete all as specified and directed by Engr-in-Charge. | 320 | Sqm | 700 ₹2,24,000 | 700 ₹2,24,000 | 780 ₹2,49,600 | 900 ₹2,88,000 | 850 ₹2,72,000 | 700 ₹2,24,000 | 660 ₹2,11,200 Lowest |
| 10.00 | S&F pre-painted galvalum aluminium zinc coated GI based plain steel sheet 0.5mm thick of any colour having tensile strength of 550 mpa as in wall cladding and roof fixed with self tapping screws as per manufacturers instruction/recommendations complete all as specified and directed by Engr-in-Charge. | 35 | Sqm | 550 ₹19,250 Lowest | 600 ₹21,000 | 650 ₹22,750 | 850 ₹29,750 | 850 ₹29,750 | 700 ₹24,500 | 700 ₹24,500 |
Tender Value
₹1.1 Cr
EMD Value
₹1.9 L
Closing Date
27 Nov 2025, 6:00 pmClosed
Shri Vinay Kumar, IDSE, SE (SAG), CWE
HQ Commander Works Engineer (Army) Mumbai 24 Assaye Building Colaba Mumbai-05
SPECIAL REPAIRS TO P-144 (OR MD ACCN) AT KALINA UNDER GE (NORTH) SANTACRUZ MUMBAI
2025_MES_737839_1
85237/N/E8
Open Tender
Civil Works
Item Rate
270 days
North Santacruz
As per NIT and tender documents
8 documents required · 8 mandatory
₹1,000
GE NORTH SANTACRUZ
₹1.9 L
Yes
21 Feb 2026
31 Oct 2025
29 Nov 2025
31 Oct 2025
27 Nov 2025
21 Nov 2025
Amount
Demolition of brick work built in cement mortar including all quoins, arches, pillars, PCC coping etc, but excluding ashlar facings, dressed stonework and precast concrete articles and removing of debris outside MD land complete all as specified and as directed by Engineer-in-Charge.
M&L for brick work with sub class 'B' bricks straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and as directed.
M&L brick work with sub class 'B' bricks, straight or curved on plan to any radius in 1/2 brick thick walls, built in cement morter 1:4 complete all as specified and as directed.
Demolition cement concrete (unreinforced) in ground floors and pavings not exc 15 cm thickness (below or above ground level), including tiles complete all as specified and directed.
Dismantling of wrought iron or mild steel work of any description not otherwise provided for
Dismantling of Asbestos Cement corrugated sheet in roof coverings
M&L for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc.
M&L preparing new steel surfaces of any description, over 10 cm in width or girth, and applying two coats of synthetic enamel paint over a coat of red oxide primer.
S&F pre-painted galvalum aluminium zinc coated GI based colour corrugated steel sheet 0.5mm thick of any colour having tensile strength of 550 mpa as in wall cladding and roof fixed with self tapping screws as per manufacturers instruction/recommendations complete all as specified and directed by Engr-in-Charge.
S&F pre-painted galvalum aluminium zinc coated GI based plain steel sheet 0.5mm thick of any colour having tensile strength of 550 mpa as in wall cladding and roof fixed with self tapping screws as per manufacturers instruction/recommendations complete all as specified and directed by Engr-in-Charge.
Taking down Chowkhats or frames not exc. 1.5sq. m each (Without taking off shutters from the frames ) including fittings complete all as specified and as directed by Engineer-in-Charge.
Taking down Chowkhats or frames exc. 1.5 sqm but n exc 4 sqm. m each (Without taking off shutters from the frames) including fittings complete all as specified and as directed by Engineer-in-Charge.
Taking down Shutters of any description exc 1 sq. m and n exc 2 sq. m each including fittings complete all as specified and as directed by Engineer-in-Charge.
Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 65 x 100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant 152 SECTION 8 and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.
Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 65 x 125 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant 152 SECTION 8 and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.
M&L for Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 35mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. Note : SS butt hinges and necessary SS screws shall be paid separately
S&F 35mm thick 2nd class hard Sal wood glazed & skeleton shutters open rebated and prepared to receive glass, gauge etc (without sash bars) edges of framing plain chamfered or rounded fitted with cut and mitred beads for securing glass etc. complete all as specified and as directed by Engineer-in-Charge.
S&F PVC door frame of size 50 mm x 47 mm made of 5 mm prelam PVC sheet and edges will be painted to match with prelam sheet.
S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame, made out of M. S. tubes for top & bottom rails. M.S. frame shall be covered with heat molded plain colour PVC `C` channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, fixing in the frame at site as per specification & drawing on Serial Page No 149 of SSR Part II (pertaining to item No 08080)complete all as specified and as directed by Engineer-in-Charge.
M&L for mild steel work in hold fast & similar small articles conforming to Fe 290 Gd 165 complete all as specified and as directed by Engineer in Charge
M&L for 1:3:6 (20mm graded aggregate) , in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, HOLD FAST string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed.
S&F 150mm floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor.
S&F 100 mm long butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21, and fixed.
S&F 125 mm long butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21, and fixed.
S&F aluminium anodised barrel tower bolt of extruded section size 150mm ISI marked.
S&F 100 mm long extruded aluminium alloy handles fabricated type anodised ISI marked.
S&F 150 mm long extruded aluminium alloy handles fabricated type anodised ISI marked.
S&F aluminium alloy, anodised, 300mm long sliding door bolt with hasp, staple(bolt type) and fixing clips of sheet.
M&L for Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket Aluminium sections shall be smooth, rust free, straight, mitredand jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ panelling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge. Note : (i) Glass panes will measured & paid separately . (ii) Rubber beading will not be weighed.
M&L for Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ panelling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-charge.
S&F Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineering- charge.
S&F 4 mm thick Sheet glass ordinary quality in square n exc 0.5 Sqm each complete all as specified and directed.
S&F 4 mm thick Sheet glass ordinary quality in square exc 0.5 Sqm each complete all as specified and directed.
S&F 4 mm thick figured glass, pin head type in square not exceeding 0.5 sqm each pane
S&F aluminium anodised wire cloth 0.45 nominal dia of wire and average width of aperture 1.40 and fixed with stainless steel wire staple.
S&F in repairs aluminium anodised wire cloth 0.45 nominal dia of wire and average width of aperture 1.40 and fixed with stainless steel wire staple.
S&F in repairs PVC low level flushing cistern of capacity 10 ltr. white with inlet, ball valve, float and handle including brackets, flush pipe of polyethylene of low or high density or PVC 32mm dia and connection to pipes and fixing of chains and pull or lever.
S & F in repairs health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified.
S&F in repairs wash basins, vitreous china(flat back or angle back type) size 550 X 400mm, including cutting for and pinning in ends of brackets or erecting stand but exclusive of supply and waste pipe complete all as specified and directed by Engr-in-Charge.
S&F in repairs fancy type 15mm dia pillar taps swan neck , cast copper alloy, with capstan heads, chromium plated complete all as specified and directed by Engr-in-Charge.
S&F in repairs, bib taps fancy type chromium plated, cast copper alloy, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or brass ferrule of 15mm bore complete all as specified and directed.
S&F in repairs, conceal stop valve fancy type cast copper alloy, fancy type, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipes or for unions of 15mm bore complete all as specified and directed.
M & L in repairs for 75mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement all as specified and as directed by Engr-in-Charge.
M & L in repairs for PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement all as specified and as directed by Engr-in-Charge.
M&L for 15mm thick rendering in cement mortar (1:3) on SUNKEN floor including water proofing compound as per specified including vertical surfaces up to 450 mm height and using and applying a coat of Raincoat solution of Make Dr Fixit and equivalent with uniform surfaces and S & F for vitreous china squatting pan, 'Orrisa' pattern/pedestal pattern, size 580 x 440mm including 'P' trap and connector pieces of CI Pipe as per required upto T /Y joint Including filling PCC 1:4:8 type D2 and over 40 mm thick PCC 1:2:4 for sub base type B 2 for uniform surfaces and GI Spout with 50 mm dia to provide that 450mm long to be extended front out surfaces of wall all as specified ad directed by Engr-in Charge .
S&F in repair, vitreous china wash down water closet pan (Pedestal pattern), white with 'p' or 's' trap (excluding flushing cistern and flush pipe), including connection to drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe etc. complete all as specified and directed.
S & F in repairs vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests (excluding flushing cistern and flush pipe) including Squatting pan including connection to trap, and to flushing pipe, anti-syphonage pipe, etc. complete including making good to floor
S&F in repairs sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm
S & F in repairs Harrison rails, mild steel, chromium plated with fixing brackets, stops, rollers etc.
S & F brass chromium plated 125mm Swivel shower of PTMT any colour for fixing with 15mm pipe. (Minimum weight 40gms)
S&F Mild steel galvanized steel tubing medium grade 15 mm bore with all fittings and fixed complete to walls and ceiling or laid in floors complete including taking down old u/s pipes
S&F Mild steel galvanized steel tubing medium grade 20 mm bore with all fittings and fixed complete to walls and ceiling or laid in floors complete including taking down old u/s pipes
S&F Mild steel galvanized steel tubing medium grade 25 mm bore with all fittings and fixed complete to walls and ceiling or laid in floors complete including taking down old u/s pipes
S & F PVC SWR Single socketed rain water pipes/soil waste pipes with rubber ring joints 110mm dia fixed to wall including taking down old u/s pipes
S & F PVC SWR Single socketed rain water pipes/soil waste pipes with rubber ring joints 75mm dia fixed to wall including taking down old u/s pipes
S&F 110mm bore PVC (SWR) bends any radius
S&F 75mm bore PVC (SWR) bends any radius
S&F PVS(SWR) Vent cowl 110mm dia.
S&F PVS(SWR) Vent cowl 75mm dia.
M & L for PCC 1:2:4 type B0 using (12.5mm graded aggregate) with 2% by weight of cement or as per manufacturer instruction waterproofing as in levelling course haunching, coping and similar works over RCC roof surface and RCC overhead tank top surface including rounded and chamfered on edges and formwork etc all as specified and directed
S & F for Rotational moulded polyethylene water storage tanks of capacity 2000 ltr (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I, etc all as specified and directed
S & F for Rotational moulded polyethylene water storage tanks of capacity 2000 ltr (cylindrical vertical with closed top) hoisted and fixed in position, including taking down old one all as specified in SSR Part I, etc all as specified and directed
S & F for 25mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed etc all as specified and directed
S & F in repairs for 25mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed etc all as specified and directed
S & F for 20mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed etc all as specified and directed
S & F in repairs for 20mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed etc all as specified and directed
S & F in repairs Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm-142gms/ 2 0 m m - 2 1 0 g m s . / 25mm-455gms/ 40mm - 690 gms)
S & F Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm-142gms/ 2 0 m m - 2 1 0 g m s . / 25mm-455gms/ 40mm - 690 gms)
M & L for Treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall
M & L for Treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors
M & L Broken stone or boulder Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for 75mm thick cement concrete (1:4:8) type D-2 using 40 mm graded stone aggregate as in sub base of flooring/ hard standing path and finishing the surface even and fair without using extra cement all as specified and directed.
M&L for 100 mm thick (1:2:4) Type B-1, Plain cement concrete with using 20mm graded aggregate as in ground floors finished even and smooth without using extra cement, complete all as specified and directed.
M & L for 25mm thick as in levelling course cement concrete type B1, 1:2:4 (20mm graded aggregate)
Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles up to a lead of 5 Km and rubbish off the premises complete all as specified and directed.
M & L for light shade vitrified ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick screed bed in CM 1:4 complete all as specified and directed.
M & L for vitrified ceramic tiles 10 mm thick (square/ rectangular) polished as in skirting, area of each tiles not exceeding 0.36 sqm, in skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10 mm thick screed bed in CM 1:4 complete all as specified and directed.
M&L for Non skid ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 but not exceeding 0.18 sqm, in floors etc, set and jointed in neat cement slurry and pointed in coloured cement including 15 mm thick screed bed in CM 1:4 .
S&F glazed ceramic Coloured tiles over vertical surface of wall,350x250x 7mm/ 450x350x7mm thick (or nearest size), set and jointed in neat cement slurry and pointed in coloured cement to match including backing coat of 10mm thick in CM(1:4) complete all as specified and directed.
Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc. laid, bedded and pointed in any mortar.
M&L for 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and the like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite., including 15 mm thick screed bed in CM 1:6 ,
M&L for Providing edge moulding to 18-20mm thick granite stone of counters vanities etc. including machine polishing to edge to give high gloss finish etc. complete all as specified and directed
M&L for Green Marble work of 18 to 20mm thick (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement in CM (1:2) using marble dust with admixture of pigment to match with marble shade of green marble., including 15 mm thick screed bed in CM 1:6 complete all as specified and directed by Engr-in-Charge.
M & L for mirror polished Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing including Screed bed or bedding layer of mortar 15 mm thick in CM (1:6) for laying floor finishes complete all as specified and directed.
M & L for mirror polished Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed including backing coat Rendering 10mm thick on fair faces in CM 1:4 of brick work or concrete surfaces complete all as specified and directed.
M & L for Machine cut cudappah stone slab over cooking plateform 20-25mm thick over cement screed base, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete
S&F of 18mm thick rajashri celuka ply of one sides prelam/rigidlam and other side plain white colour to make kitchen cabinet shutter/drawer front shutters complete all as per specifications and as directed by Eng-in-charge. (taking down taken in Item No 11)
S&F of 18mm thick rajashri celuka ply of plain colour fixed with screws, solvent cement/adhesive to make kitchen cabinet sides , top and bottom and shelves inside the cabinets complete all as per specifications and as directed by eng-in-charge
S&F of auto closing hinges openable at 0 degree for kitchen cabinet shutters as per directed.
S&F of SS handles of 100mm size for kitchen cabinet shutters, etc. as per directed.
M&L for preparing old wood based surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified & directed by Engineer-in-Charge.
Demolition of reinforcement cement concrete (reinforcement cut as required to facilitate demolition) of any position (column, Beam, chajja, fins, RCC water tank and Roof slab etc) ground floor/other than ground floor complete all as specified and as directed by Engr-in-charge.
Providing and applying rust cleaner (Re-backler solution) to exposed corroded reinforcement @ 0.20 Litre/Sq or approved make over prepared reinforcement, including removing concrete all around reinforcement including from behind the reinforcing bars by manual methods such as hammering the rebar, using wire brushes, chiselling, etc. and applying rust removing solution of approved make with cotton waste swab to reinforcements etc. complete as directed by Engineer-In-Charge.
Providing and applying two coats of anticorrosive epoxy phenolic rebar protective system IPNet RB or equivalent of approved make and quality comprises of resin and hardener mixed in equal proportion by volume with minimum 9-10 hours between the coats, sprinkling dry sand when 2nd coat is tacky so as to provide rough finish and ensuring air curing of minimum 10 hours after the top coat before any subsequent treatment etc. including scaffolding etc. complete all as specified and as directed by Engr-in-Charge. NOTE:- New Reinforcement shall be measured and paid separately under respective item. (b) Cost of welding deemed to be included in quoted rates.
Providing and applying a priming cum bonding coat of two component Epoxide Resin conforms to ASTM-C-882-91 of approved make and quality to clean and sound concrete area by brush or any other established method by mixing Base and curing agent in 2:1 proportion by weight for joining old and new concrete as per technical specifications of manufacturer. Work shall be carried out as per the manufacturers specifications & certificate on this account shall be taken from consultant and as approved by Engineer-in-charge etc. Complete.
M & L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips
M & L for TMT bars 6 to 8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips
Providing & Fixing MS/TS dowel pins/staple/shear pins including drilling holes in concrete and providing labour and but including the materials for grouting the pins. Etc complete all as specified and as directed by Engr-in-Charge.
Providing and fixing the formwork of to pour the micro concrete/concrete using steel shutters or 12mm marine ply to have the form finish including de-shuttering etc complete all as specified and as directed by Engr-in-Charge.
Providing and casting and repairing the damage concrete portion by using superfluid dual shrinkage compensated structural grade M-40 Micro concrete including providing, applying, finishing, curing etc complete all as specified and as directed by Engr-in-charge.
Material and labour for surface preparation of existing concrete components including grinding/rubbing carefully by grinder without damaging the existing concrete including cleaning the surfaces by blower, removal of external plaster wherever exists. Cost inclusive of transportation, labour conveying debris away from the Defence land, tools and tacklers, lead and lift and clean water thoroughly complete all as specified and directed by Engr-in-Charge
Material and labour for providing and laying average 20 mm thick polymer modified mortar over identified RCC members in one layer in proportion 1:5:15 by weight of polymer, cement and filler material of approved make, blended to a required consistency and applying and finishing by floating, curing after initial setting time, including providing and inserting 10 mm mild steel shear key bars (minimum 3 nos per sqm) wherever required, bonding slurry etc., complete all as specified and as directed by engineer in charge.
Taking down cement plaster on brick / concrete surface etc on internal / external surface of wall / ceiling surface including racking out joints hacking for key, scrubbing down with water complete all as specified and as directed by Engr-in-Charge and deposited the debris outside the MD land complete all as specified and as directed by Engineer-In-Charge.
Material and labour for rendering 10mm thick on internal wall surfaces using factory manufactured pre mix/ready mix plaster of 'Roofit Mix' of M/s Premier Floor to Roof Materials Pvt Ltd / 'Easy plast' of M/s Walplast Products Pvt Ltd / 'Readiplast' of M/s Ultratech Cement Ltd / Sound last PMC-1 of M/s Sound Buildcare Pvt Ltd / or other approved equivalent make, having minimum composition of C:S : 1:3 using fully treated dry, well graded natural sand conforming to IS 383 suitable for plastering, having low rebound properties, low water demand for curing properties, mechanical mixing with water in a metallic tray only to make good consistency as per the specification of the Manufacturer and applied over masonry and concrete surfaces and finishing with sagol finish not less than 1mm thick, including cleaning the surfaces, curing etc complete all as specified & directed by Engineer-in-Charge
Material and labour for rendering 5 mm thick on ceiling using factory manufactured pre mix/ready mix plaster of 'Roofit Mix' of M/s Premier Floor to Roof Materials Pvt Ltd/Easy plast' of M/s Walplast Products Pvt Ltd/Readiplast of M/s Ultratech Cement Ltd / Sound last PMC-1 of M/s Sound build care Pvt Ltd/or other approved equivalent make, having minimum composition of C:S : 1:3 using fully treated dry, well graded natural sand confirming to IS 383 suitable for plastering in ceiling, having low rebound properties, low water demand for curing properties, mechanical mixing with water in a metallic tray only to make good consistency as per the specification of the Manufacturer and applied over concrete surfaces and finishing with sagol finish not less than 1mm thick, including cleaning the surfaces, curing etc complete all as specified & directed by Engineer-in-Charge.
Material and labour for rendering 15 mm thick cement plaster (incl. dubbing out) in CM 1:4, two coats using factory manufactured pre mix/ready mix of 'Roofit Mix' of M/s Premier Floor to Roof Materials pvt.ltd/ 'Easy plast' of M/s Walplast Products pvt.ltd/ 'Readiplast' of M/s Ultratech Cement Ltd/'Soundplast PMC-1' of M/s Sound buildcare pvt.Ltd/ or other approved equivalent make, having minimum composition of C:S: 1:4 using fully treated dry, well graded natural sand conforming to IS 383 suitable for external plastering, having low rebound properties, low water demand for curing properties, mechanical mixing with water in a metallic tray only to make good consistency as per the specification of the Manufacturer and applied over exterior masonry and concrete surfaces with base coat of 10 mm thick and finishing coat of 5 mm thick final rendering with water proofing compound @3% as per manufacturer's instructions, including using richer mix for making corners if necessary, at all floors and level, including making grooves of existing size wherever required, including sagol finish including cleaning the surfaces, curing including provide of 150mm chicken wire mesh fixed with nails at the junction of RCC columns/walls/ beams/ lintels and brick masonry at external faces before plastering including scaffolding at any height and all safety materials required for execute work etc. complete all as per specifications & as directed by the Engineer-in-Charge.
M&L for Rendering 10mm thick cement plaster on fair faces of brick work or concrete surfaces in CM 1:6, including finishing the surface even and smooth without using extra cement complete all as directed
M&L for rendering 5mm thick cement plaster in cement mortar 1:3 on fair faces of brick work or concrete surfaces of ceiling and finishing the surface even and smooth without using extra cement complete all as specified and as directed.
M&L for rendering 15mm thick cement plaster in two coats (10mm under coat and 5mm finishing coat) in cement mortar 1:4 on fair faces of brick work or concrete surfaces and finishing the surface even and smooth without using extra cement, both coats mixed with water proofing compound @ 3 % by the weight of cement complete all as specified and as directed. Note :- Water proofing compound shall be measured and paid separately.
Supply only integral water proofing compound.
M&L for preparation of new plastered ceiling surfaces and applying two coats of Distemper oil emulsion over a coat of priming plastered and other surfaces with alkali resistant priming paint complete all as specified and directed.
M&L for preparation of newly plastered surfaces of wall and applying two coats of Distemper oil emulsion over a coat of Priming plastered and other surfaces with alkali resistant priming paint , complete all as specified and directed
M & L for finishing newly plastered walls with Acrylic Smooth exterior paint of required shade Two coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
M&L for complete removal of existing treatment of paint on wall and applying two coats of Distemper oil emulsion plastered and other surfaces on wall upto the height of bldg with all safety belts/formwork/ scaffolding etc complete all as specified and directed
M & L for 1.5mm thick Putty wall care putty on wall/ ceiling.
M&L for opening out cracks in wall surfaces in 'V' shape by mechanical grinder and removing the loose material, filling with crack filler of Dr. Fixit crack-X, shrink free or equivalent all as per manufacturer's instructions and finishing the surfaces to match with existing finish complete all as specified and as directed.
M & L Surface preparation of existing concrete components including grinding/rubbing carefully by grinder without damaging the existing concrete including cleaning the surfaces by blower , removal of external plaster wherever exists. Cost inclusive of transportation, labour conveying debris away from the Defence land, tools and tacklers, lead and lift and clean water thoroughly complete all as specified and directed by Engr-in-Charge.
Material and labour for providing and laying average 20 mm thick polymer modified mortar over identified RCC members in one layer in proportion 1:5:15 by weight of polymer, cement and filler material of approved make, blended to a required consistency and applying and finishing by floating, curing after initial setting time, including providing and inserting 10 mm mild steel shear key bars (minimum 3 nos per sqm) wherever required, bonding slurry etc., complete all as specified and as directed by engineer in charge.
Taking down carefully surface aluminium or copper point wiring with PVC casing-capping/ stove enamelled steel conduit (steel conduit, light, fan, socket, bell or power) including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc and making good disturbed surfaces complete all as directed.
M&L for point wiring with 1100 volts grade PVC insulated FR-LSH multistranded copper conductor cable 1.5 sqmm (Phase - R /Y/ B, Neutral - Black) and earth continuity conductor 1.5 sqmm (Green) drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all conduit fittings / fixing accessories and sunken galvanized pressed modular steel terminal boxes of appropriate thickness covered with suitable and required size of modular box, plate with cover for mounting modular switches, sockets, fan regulators complete including cutting chases in wall/floor/ceiling and making good wall surfaces with matching colour on wall for the following including (a) One light point controlled by one switch.
(b) One fan/ Exh fan point controlled by one switch.
(c) One socket outlet 6 amp controlled by one switch on the same board with other switches.
(d) One socket outlet 6 amp controlled by one switch on independent board.
(f) One bell point controlled by one bell push.
M&L for Point wiring with 1100 volts grade PVC insulated FRLSH multistranded copper conductor cable 2.5 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 2.5 sqmm (Green) drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all conduit fittings / fixing accessories and sunken galvanized pressed steel terminal box of appropriate thickness covered with suitable and required size of modular box, plate with cover for mounting modular switches for one 16 amp socket outlet controlled by one switch on independent board complete including cutting chases in wall/floor/ceiling and making good wall surfaces with matching colour on wall complete all as specified and as directed by Engr-in-charge.
S&F modular switch one way 6 amp 1 module ISI marked all as specified and directed
S&F modular switch one way 16 amp 1 module ISI marked all as specified and directed
S&F modular socket 6/16 - 2/3 pin combined 2 module ISI marked all as specified and directed
S&F modular socket 6 amp 2/3 pin combined 2 module ISI marked all as specified and directed
S&F Ceiling rose 6 amp, 3 plates polycarbonate body complete
S&F modular hum free electronic step fan regulator, 100 watt 2 module all as specified and directed
S&F bell multi music type, AC, 240 volts complete. Make-Anchor or SSK or Havells Reo as approved.
S&F bell push, modular type, 6 amp 240 volts complete.
M&L for Point wiring for Geyser with 1100 volts grade PVC insulated FRLSH multistranded copper conductor cable 4 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 4 sqmm (Green) drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all conduit fittings / fixing accessories and sunken galvanized pressed steel terminal box of appropriate thickness covered with suitable and required size of modular box, plate with cover for mounting modular switches for one 16 amp socket outlet controlled by one switch on independent board complete.
S&F MCB distribution board SPN, 240 volts, 8 ways double door powder coated, CRCA steel sheet constructed as per IS : 8623, degree of protection IP 43 - IK 09 with metal door, recess mounted, having insulated 100 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required.
S&F in replacement existing UNSV LED batten (1.2 m) made of Aluminium housing with a PC glossy diffuser duly prewired connection having a nominal system lumen output of 2000 lumens at a minimum system efficacy of 100+ lumens per watt and total power consumption not less than 20 watt including driver. It has a rated system life time of 40000 burning hours at L70 and should have a color temperature of 6500K, CRI>80, THD < 10% and PF > 0.95 complete.
S&F in replacement existing UNSV LED 35W streetlight made up of pressure die cast housing with prismatic polycarbonate diffuser and individual LED's with secondary optics and IP65 protection complete with fixing arrangement and connections as directed
S&F in replacement existing UNSV LED light fitting mirror type with high output diffuser 2 feet, 10 watt 220V AC decorative type with driver holder LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete.
M&L for submain wiring alongwith earth continuity conductor with PVC insulated FRLSH multistranded copper conductor cable (Phase - Red, Neutral - Black, Earth - Green) drawing into and including concealed rigid non metallic PVC conduit, medium grade, ISI marked ivory colour along with accessories of following nominal sizes:- (a) 2x6 sqmm + 1x6 sqmm earth continuity conductor in 20/25 mm dia conduit..
(b) 2x4 sqmm + 1x4 sqmm earth continuity conductor in 20 mm dia conduit..
M&L for earthing complete with galvanized steel earth plate electrode 60cmX60cmX6mm thick buried directly in ground (earth plate not less than 2.25 mtr deep below the normal ground level) with top edge of plate not less than 1.5 mtr below the normal ground level connected to galvanized earth lead wire of 4.0mm dia by means of nuts bolts, washers, check nuts of iron or steel including PCC pits and RCC cover in PCC 1:2:4 (type B-1) and necessary earth work in any type of soil medium grade GI watering pipe 20 mm dia with funnel and wire mesh and 15mm bore GI pipe light grade protection pipe upto test point etc including excavation and charcoal, common salt surrounded with 15cm all around the plate all as specified and shown in EP-5 of SSR Part-I. all specified
S&F MCBs as per load requirement 'C' series of breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs of following ratings:- (a) Single pole 6 to 32 amp.
(b) Double pole 32 amp.
Taking down carefully aluminium or copper submain wiring with PVC surface conduit or casing capping and making good disturbed surfaces complete.
Taking down MCB distribution boards with incoming and outgoing controls any make, any capacity after disconnecting complete.
Taking down Ceiling Fan/ Exh fan of any make, type and sweep by disconnecting Electric Connection and keeping in MES store yard.
Hanging only old ceiling fan/ Exh fan obtained from taking down and connecting up including provision of cable from ceiling rose or connector to fan.
S&F air ventilation fan 250 mm in toilet in rectangular in shape, PVC body, white colour 230V including louber shutter complete all as specified and directed, including hole & make good the wall surface complete.
Supply & fix exhaust fans AC single Phase 230/240 V of size 300 mm sweep, metal body including cutting hole & making good the wall surface complete.
Supply and fix in repairs Indoor Decorative light, wall mounting, Metal, glass home, 220-240 V with E27 LED bulb of 9 Watts including connecting up with three core flexible copper conductor cable of suitable size including taking down existing light fittings etc complete all as specified and directed by Engr-in-charge.
Dismantling and taking down old unserviceable meter cabinet of any description after necessary disconnection of all incoming and outgoing connections complete and supply, installation, testing and commissioning of indoor type, meter cabinet for suitable size made out of 2.0 mm thick CRCA MS sheet with front door having glass window for viewing KWh meter and other doors shall be opaque. All doors should have gasket and locking arrangement. The cabinet shall be painted both internally and externally with two coats of synthetic enamelled paint (Shade- Smoke Grey) over a coat of red oxide metal primer duly sprayed with the compressor. The cabinet shall be dust and vermin proof with degree of protection of IP 43. The cabinet shall be comprising with the following accessories :-
(a) Supply and fix of four pole MCCB, 100 Amps, with breaking capacity 16 KA having adjustable thermal and fixed magnetic release. (b) Supply and fix of copper bus bar of cross section 25 x 3 mm duly mounted on FRP/DMC insulators and necessary drilling (1 Incoming & minimum 4 Outgoing) for connections and duly covered with heat shrinkable PVC sleeves of stranded colour code-04 Nos (Bus bar chamber shall be covered with necessary CRCA sheet cover duly screwed so that the live part shall not be exposed). (c) Re fixing of Single phase KWh meter of rating 10-60 Amps, base mounting, electronic temper proof type with optical port suitable for AC 230 volts, 50 Hz supply. (d) Supply and fix MCB SPN 63A - 08 Nos (e) Supply and fix MCB SPN 16 A- 01 No (f) Internal wiring of meter / MCB / Cable connector, shall be carried out with 10 Sqmm multicore flexible copper wire with FR grade PVC insulation of 1100 volts rating including necessary lugs / nuts / bolts / washers etc.
mp construction co (BID ID -3480594)
Vishal Builders (BID ID -3482372)
Advait Enterprises (BID ID -3489867)
the bhimani group of companies (BID ID -3482898)
LUCKY DECOR (BID ID -3481571)
OM INFRA (BID ID -3489113)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.46 MB
Tenderdocuments85237.pdf
Tender Documents • 1.28 MB
BOQ_826174.xls
BOQ • 0.47 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .