Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹56.2 LAccepted-AOC D 1 KHOTTA TOLA KUNGRAGHAT GORAKHPUR | GORAKHPUR | GORAKHPUR | UTTAR PRADESH | 273008 | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹62.9 L+₹5.9 L (10.3%)Rejected-Finance | L2 | Rejected-Finance BEING NOT LOWEST | |
| 3 | L3₹63.8 L+₹6.8 L (11.9%)Rejected-Finance HOUSE NO 8 T SHIVPUR MAHADEV JHARKHANDI TUKRA NO 1 P O KUNRAGHAT DISTT GORAKHPUR UTTAR PRADESH 273008 | GORAKHPUR | GORAKHPUR | UTTAR PRADESH | 273008 | L3 | Rejected-Finance BEING NOT LOWEST | |
| 4 | L4₹73.3 L+₹16.3 L (28.6%)Rejected-Finance | L4 | Rejected-Finance BEING NOT LOWEST |
Tender Value
₹97 L
EMD Value
₹1.7 L
Closing Date
7 Oct 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE (AF) BAMRAULI
HQ CWE (AF) BAMRAULI Allahabad 211012
ADDITION ALTERATION OF EXISTING ELECTRICAL WIRING / FIXTURE AND PROVISION OF SPECIAL POWER SUPPLY INSIDE TECHNICAL BUILDING AT AF STATION GORAKHPUR
2020_MES_370774_1
87071/C/E8
Open Tender
Civil Works - Others
Item Rate
273 days
Gorakhpur
Please refer Tender documents.
9 documents required · 9 mandatory
₹1,000
GE (AF) Gorakhpur
₹1.7 L
Yes
7 Nov 2020
3 Sept 2020
10 Oct 2020
3 Sept 2020
7 Oct 2020
23 Sept 2020
90 days
Amount
Excavating in trenches, not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for wall foundation etc or for manholes etc not exceeding 10 Sqm area on plan and not exceeding 1.5 metre in depth and getting out in soft/loose soil complete all as specified and directed by Garrison Engineer / Engr-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers each not exceeding 25 cm thick in soft/loose soil complete all as specified and directed by Garrison Engineer / Engr-in-Charge.
Removing excavated surplus soil to a distance not exceeding 50 metre and depositing where directed at level not exceeding 1.5 metre above the starting point complete all as specified and directed by Garrison Engineer / Engr-in-Charge.
Supply and lay sand cushioning for under ground cable with locally available sand for protection of cable 8cm before laying cable and 15cm deep over the cable including spreading and consolidations, complete all as specified and directed by Garrison Engineer / Engr-in-Charge. Note :- Punned thickness will be measured and paid.
Supply and laying in trenches dry well burnt locally available sub class 'B' bricks best class locally available laid over sand cushioning for protection of cable complete all as specified and directed by Garrison Engineer / Engr-in-Charge.
Supply and fix 80mm bore steel tubing galvanised “Light Grade” in trenches/poles, under floors, roads, along poles for protection of cables, including sealing ends all as specified complete all as specified and directed by Engineer-in-Charge. Note :- Clamps for fixing pipe on poles shall be included the unit rate quoted by contractor.
Taking down carefully aluminium batten point, wiring for light/fan/socket/bell or power point including all fittings i.e. switch, sockets, ceiling rose, regulators, batten holders, etc. Complete and making good disturbed surfaces of wall/floor to match with the surroundings of wall/ceiling/floor etc including taking down old light fittings security light with bracket etc complete all as specified and directed by Garrison Engineer / Engr-in-Charge. Note :- Contractors quoted rate of this item deemed inclusive of unscrewing of the old light fittings, security light fitting and fixture as directed and shall be deposited in the MES store yard and necessary receipt shall be obtained before claiming the payment of new light fittings.
Point wiring with PVC insulated, unsheathed single core, nominal area 1.5 sqmm with multistranded copper conductor FRLS Cable 1100 volts grade drawn into and included rigid PVC conduit (concealed) with all PVC conduit fittings such as Tees, elbows, bend, reducers etc and 1.5 sqmm unsheathed copper conductor earth wire connected to earth dolly including metal junction box, grid plate and base plate suitable for modular switches, sockets for one sockets outlet on same board controlled by one switch 5/6 Amps complete all as specified and directed by Garrison Engineer / Engr-in-Charge. Note :- (i) Contractors quoted rate of this item deemed inclusive of unscreasing of the service fitting and fixture as directed and kept in safe custody for refixing i.e like fans, regulator, geysers, light fitting, DBs etc if not specified in this item of schedule. (ii) Quoted rate also deem to be included cost of cutting chases for taking out concealed conduit and nitch for terminal box. (iii) Decision of GE shall be final and binding in respect of serviceability of fittings/fixture. (iv) The cost of chases cutting on wall for concealing conduit, metal boxes, grid plate and base plate quoted rated are included in the unit. (v) Switches, sockets, etc shall be measured and paid for separately.
Point wiring with PVC insulated, unsheathed single core, nominal area 1.5 sqm with multistranded copper conductor FRLS Cable 1100 volts grade drawn into and included rigid PVC conduit (concealed) with all PVC conduit fittings such as Tees, elbows, bend, reducers etc and 1.5 sqmm unsheathed copper conductor earth wire connected to earth dolly including metal junction box, grid plate and base plate suitable for modular switch, socket for one sockets outlet on independent board controlled by one switch 5/6 Amps complete all as specified and directed by Garrison Engineer / Engr-in-Charge. Note :- (i) The cost of chases cutting on wall for concealing conduit, metal boxes, grid plate and base plate are included in the unit quoted rate. (ii) Switch, and socket, shall be measured and paid for separately.
Point wiring with PVC insulated, unsheathed single core, nominal area 4 sqm with multistranded copper conductor FRLS Cable 1100 volts grade drawn into and included rigid PVC conduit (concealed) with all PVC conduit fittings such as Tees, elbows, bend, reducers etc and 4 sqmm unsheathed copper conductor earth wire connected to earth dolly including metal junction box, grid plate and base plate suitable for modular switch, socket for one sockets outlet on independent board controlled by one switch 15/16 Amps complete all as specified and directed by Garrison Engineer / Engr-in-Charge. Note :- (i) The cost of chases cutting on wall for concealing conduit, metal boxes, grid plate and base plate are included in the unit quoted rate. (ii) Switch, and sockets, shall be measured and paid for separately.
Supply and fix switch modular flush 10 Amps single pole one way (one module) 230 volts AC complete all as specified and directed by Garrison Engineer / Engineer-in-Charge.
Supply and fix Ceiling rose, surface bakelite, 60 x 25, mm three terminals complete all as specified and directed by Garrison Engineer / Engineer-in-Charge.
Supply and fix modular socket 10/16 Amp, 2/3 pin combined (two module) 230 volts AC complete all as specified and directed by Garrison Engineer / Engineer-in-Charge.
Supply and fix modular socket 10 Amp, 2/3 pin combined (two module) 230 volts AC complete all as specified and directed by Garrison Engineer / Engineer-in-Charge.
Supply and fix switch modular flush, 15/16 Amp, single pole, one way 230 volts AC complete all as specified and directed by Garrison Engineer / Engineer-in-Charge.
Supply and fix fan regulator 120 watts (two module) 230 volts AC step type complete all as specified and directed by Garrison Engineer / Engineer-in-Charge.
Supply and fix bell push modular flush type, 10 Amp, single pole, one moudle 230 volts AC complete all as specified and directed by Garrison Engineer / Engineer-in-Charge.
Supply and fix industrial socket with single pole and neutral sheet metal enclosure with a two pin and earth plug and socket 240 V 50 Hz complete with one single pole MCB, 20 Amp, 'C' series complete all as specified and directed by Garrison Engineer / Engineer-in-Charge..
Supply and fix call bell ding dong single pole, 230 volts AC complete all as specified and directed by Garrison Engineer / Engineer-in-Charge.
Supply and fix flame proof weather proof switch socket and plug combined in , 16Amp, 250V, 2P+earth complete all as specified and directed by Garrison Engineer / Engineer-in-Charge.
Material and labour sub main wiring with 2 run of single core PVC insulated and PVC Unsheathed, multistranded copper condutor of nominal area 2.5 Sqmm FRLS, 1100 Volts grade cable drawn into and including mild steel stove enamelled Conduit of size not less than 25mm dia including all fittings fixed in wall / ceiling surface and one run of PVC insulated and PVC unsheathed, multistranded copper conductor of nominal area 2.5 sqmm FRLS 1100 volts grade cable continuous earth wire of green colour code complete all as specified and directed by Garrison Engineer / Engr-in-Charge. Note:- (a) Two runs of 2.5 sqmm cable and one run of 2.5 Sqmm cable as earth lead with MS conduit shall be measured as one unit length for payment. (b) Quoted rate shall deem to be included cost of cutting chasses in wall for concealling conduit and making good to match with existing finish where ever is required.
Material and labour sub main wiring with 2 run of single core PVC insulated and PVC Unsheathed, multistranded copper condutor of nominal area 10 Sqmm FRLS, 1100 Volts grade cable drawn into and including PVC rigid Conduit of size not less than 25mm dia including all fittings fixed in wall / ceiling surface and one run of PVC insulated and PVC unsheathed, multistranded copper conductor of nominal area 10 sqmm FRLS 1100 volts grade cable continuous earth wire of green colour code complete all as specified and directed by Garrison Engineer / Engr-in-Charge. Note:- (a) Two runs of 10 sqmm cable and one run of 10 Sqmm cable as earth lead with PVC conduit shall be measured as one unit length for payment. (b) Quoted rate shall deem to be included cost of cutting chasses in wall for concealling conduit and making good to match with existing finish where ever is required.
Suply and fix engineering plastic batten with white acrylic cover LED light 6000 K 4 fit long ( integrated LED channel) natural white,energy saving of 20 W complete with its all acessories internally perwired and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed by Garrison Engineer / Engr-in-Charge. Make : Philips Cat part No Smart Bright 20W 4fit, Havells Cat part No ENDURALINEARNEOBS20WLED865SPCWH and CG Cat part No TRIMLINE LDL-20-NW or equivalent model of make specified in appendix 'B' to particular specifications.
Supply and fix Flame proof / weather proof LED tube light fittings 2x20 watt (4 feet) with all fixture , wire guard and reflector complete fixed to walls/hang test properly complete all as specified and directed by Garrison Engineer / Engr-in-Charge. Note :- (i) Unit quoted rate shall deemed to inclucde the cost of double stiff pedent as required. (ii) Make of sudhir cat part No FF/OA/1271/402 or equivalent model of make specified in appendix 'B' to particular specifications.
Supply and fix LED Flood light 150 watt IP 66 protection including necessary electric connection with twin core twisted flexible copper conductor cable of suitable size and length including discoonection connection and taking out existing unserviceable high bay light fitting of any description and fixed in any position from hanger deposited to store yard of AGE EM of GE (AF) Gorakhpur duly verified receipt from AGE EM and AAO of GE (AF) Gorakhpur complete. . Make : Philips Cat part No BVP LED 150 CW HE NB FG XTFCL S4, Havells Cat part No JETAIRISFLS150WLED757PSYMLTG. and CG Cat part No PLUTO NEO LFLN-150-CDL/60-M or equivalent model of make specified in appendix 'B' to particular specifications.
Supply and fix factory made sheet metal enclosure distribution boards, (protection class IP-42) double door, suitable for mounting MCBs conforming to IS : 13032, IS : 8623, BS : 5484 with 200 Amps rating copper bus bar, vertical tripple pole and neutral, 4 ways, 415 volts 50 Hz complete all as specified and directed by Garrison Engineer / Engr-in-Charge. Note :- MCBs shall be measured and paid for separately as supply only under respective item of this schedule.
Supply and fix factory made sheet metal enclosure distribution boards, (protection class IP-42) double door, vertical type suitable for mounting isolator fixing MCCB/MCBs conforming to IS : 13032, IS : 8623, BS : 5484 with 200 Amps rating copper bus bar, triple pole and neutral, 4 ways, 415 volts 50 Hz complete all as specified and directed by Garrison Engineer / Engr-in-Charge. Note :- MCBs and MCCB shall be measured and paid for separately under respective item of this schedule.
Supply and fix factory made sheet metal enclosure distribution boards, (protection class IP-42) double door, suitable for mounting MCBs conforming to IS : 13032, IS : 8623, BS : 5484 with 200 Amps rating copper bus bar, single pole and neutral, 8 ways, 240 volts 50 Hz complete all as specified and directed by Garrison Engineer / Engr-in-Charge. Note :- MCBs shall be measured and paid for separately under respective item of this schedule.
Supply and fix MCCB, with enclosures four pole, 415 Volt, 50 Hz, 400 Amp rating, 35 KA ultimate breaking capacity fixed in DBs catered herein before complete all as specified and directed by Garrison Engineer / Engr-in-Charge.
Supply and fix MCCB, four pole, 415 Volt, 50 Hz, 125 Amp rating, 36 KA ultimate breaking capacity fixed in DBs catered herein before complete all as specified and directed by Garrison Engineer / Engr-in-Charge.
Supply and fix MCB, SP, 6 to 32 Amp rating, 230 volt, 10 KA, 'C' series fixed in DBs catered herein before complete all as specified and directed by Garrison Engineer / Engr-in-Charge.
Supply and fix MCB, in repairs tripple pole and neutral, 415 volt, 63 Amp rating 10KA, C series fixed in DBs catered herein before complete all as specified and directed by Garrison Engineer / Engr-in-Charge.
Supply and fix MCB, in repairs tripple pole and neutral, 415 volt, 40 Amp rating 10KA, C series fixed in DBs catered herein before complete all as specified and directed by Garrison Engineer / Engr-in-Charge.
Supply and fix MCB, Single pole and neutral, 230 volt, 40 Amp rating 10KA, C series fixed in DBs catered herein before complete all as specified and directed by Garrison Engineer / Engr-in-Charge.
Supply and fix tripple pole and earth enclosure with a three pin and earth plug and socket with one tripple pole 63 Amp, 'C' series MCB (3P+N+E) Industrial wall mounted plug socket suitable for IP - 67 degree of protection complete all as specified and directed by Garrison Engineer / Engineer-in-Charge.
Supply and fix Wall mounted fan 450mm sweep and connecting up including three core PVC insulated multistanded copper conductor cable size 1.5 sq.mm from ceiling rose. Note :- Make of fan shall be Havells model No. Airbol High speed or equivalent model of make as specified in Appendix 'B' to particular specifications
Supply and fix ceiling fans 1200 mm sweep white in colour of Aluminium blades(three numbers) and body,double ball bearing, down rod.fan motor,pair of canopy, shackle, assembly kit etc suitable for SP 230 to 250 volts, 50 Hz, AC supply including three core PVC insulated multistanded copper conductor cable size 1.5 sq.mm from ceiling rose including taking down old ceiling fan and deposited to store yard of AGE EM of GE (AF) Gorakhpur complete all as specified and directed by Garrison Engineer / Engr-in-Charge. Note :- (i) Make Havells CAT No ES-50, 5 star (energy saving fan) or equivalent model of make specified in Appendix 'B' to particular specifications.
Supply and fix exhaust fans (metallic) of 450 mm sweep, heavy duty, four blade, double ball bearing ,1400 RPM, minimum suitable for SP, 230 / 250V, 50 Hz, AC supply with louver shutters including making holes in brick wall of suitable size and disturbed surfaces shall be made good to match the existing finishes complete all as specified and directed by Garrison Engineer / Engr-in-Charge. Note :- (i) Make Havells Model No : Ventil Air or equivalent model of make mentioned in Appendix 'B' to particular specifications. (ii) Unit rate quoted by tenderer is deemed to include the cost of demolition /dismanting of brick work in wall for making hole and making good the surfaces to match existing schedule of finishes.
Supply and fix exhaust fans (metallic) of 300/308 mm sweep, heavy duty, four blade, double ball bearing ,1400 RPM, minimum suitable for SP, 230 / 250V, 50 Hz, AC supply with louver shutters including making holes in brick wall of suitable size and disturbed surfaces shall be made good to match the existing finishes complete all as specified and directed by Garrison Engineer / Engr-in-Charge. Note :- (i) Make Havells Model No : Ventil Air or equivalent model of make mentioned in Appendix 'B' to particular specifications. (ii) Unit rate quoted by tenderer is deemed to include the cost of demolition /dismanting of brick work in wall for making hole and making good the surfaces to match existing schedule of finishes.
Supplying, laying, testing and commissioning of XLPE insulated, PVC bedded, galvanised steel strip armoured, heavy duty electric cable with stranded aluminium conductor, 1100 Volts grade, connecting both end with suitable lugs of cross sectional area 50 sqmm 3.5 core, complete all as specified and directed by Garrison Engineer / Engr-in-Charge. Note :- Excavation, earth work, sand cushioning, protection cover and pipe shall be measured and paid for separately under respective items of this schedule.
Supplying, laying, testing and commissioning of XLPE insulated, PVC bedded, galvanised steel strip armoured, heavy duty electric cable with stranded aluminium conductor, 1100 Volts grade, connecting both end with suitable lugs of cross sectional area 120 sqmm 3.5 core, complete all as specified and directed by Garrison Engineer / Engr-in-Charge. Note :- Excavation, earth work, sand cushioning, protection cover and pipe shall be measured and paid for separately under respective items of this schedule.
Supplying, laying, testing and commissioning of XLPE insulated, PVC bedded, galvanised steel strip armoured, heavy duty electric cable with stranded aluminium conductor, 1100 Volts grade, connecting both end with suitable lugs of cross sectional area 185 sqmm 3.5 core, complete all as specified and directed by Garrison Engineer / Engr-in-Charge. Note :- Excavation, earth work, sand cushioning, protection cover and pipe shall be measured and paid for separately under respective items of this schedule.
Earthing complete with galvanised steel earth plate electrode 60 x 60 cm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised iron wire 4 mm dia as earth lead wire by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in Electrical plate No. 3, MES SSR Part I- with 15 mm dia medium grade GI pipe as a protection to earthing lead and 20 mm dia medium grade GI pipe for watering purpose including excavation & earth work in any type of soil, funnel, wire mesh, RCC pit with cover, cast iron frame complete and connected to earthing test point all as specified or indicated including testing on completion complete all as specified and directed by Garrison Engineer / Engr-in-Charge. Notes (i) The concrete pit shall be PCC (1:3:6) type C-1, 40mm thick precast cover slab of RCC with suitable Mild steel handle in lieu of cast iron cover shown in electrical plate No 3 of MES SSR Part-I. (ii) PCC pit shall be provide at least 500 mm away from the earth pit and not on just on the eath pit and extra cost of additional length of water pipes and fittings junction etc shall be deemed to be included in the rate. (iii) Item includes the cost of 7.5 metre earth lead wire and GI pipe for protection of earth wire. Any varriation in quantity shall be adjusted.
Earthing complete with galvanised steel earth plate electrode 60 x 60 cm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised steel strip 32 x 6 mm as earth lead wire by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in Electrical plate No. 3, MES SSR Part I- with 15 mm dia medium grade GI pipe as a protection to earthing lead and 40 mm dia medium grade GI pipe for watering purpose including excavation & earth work in any type of soil, funnel, wire mesh, RCC pit with cover, cast iron frame complete and connected to earthing test point all as specified or indicated including testing on completion complete all as specified and directed by Garrison Engineer / Engr-in-Charge. Notes (i) The concrete pit shall be PCC (1:3:6) type C-1, 40mm thick precast cover slab of RCC with suitable Mild steel handle in lieu of cast iron cover shown in electrical plate No 3 of MES SSR Part-I. (ii) PCC pit shall be provide at least 500 mm away from the earth pit and not on just on the eath pit and extra cost of additional length of water pipes and fittings junction etc shall be deemed to be included in the rate. (iii) Item includes the cost of 7.5 metre earth lead wire and GI pipe for protection of earth wire. Any varriation in quantity shall be adjusted.
Material, labour, errecting and testing copper earth plate of size 90 x 60 x 5 mm chemical earthing with pit, high conductive, corrotion restistant CPRI tested Earth, Earthing Electrode of copper earth strip 32x6mm in copper pipe of 80mm dia thickness not less than 2.5mm 3000 mm lenght (Model MRC-C80) duly filled with Crystal Conductive Mixture (CCM) and between earth pit and pipe with Earth resistance Improvement Compound (ERIC) for achieving ohmic value equal to or less than 1 Ohm including PCC earth pit with cover of size 450x450mm and multiway testing point complete all as specified and directed by Garrison Engineer / Engr-in-Charge. Note:- Unit quoted rate shall include the cost of testing to achiev the desired result without any extra cost to the Govt.
Supply and fix Air termination single pointed Aluminium rod, 12 mm dia, 300mm long fix in position complete all as specified and directed by Garrison Engineer / Engr-in-Charge.
Supply and fix Test point terminal block made of gun metal or phosphorus bronze size 75X75X25mm drilled and screwed including 3 numbers, 8mm dia 25mm long hexagonal head screw complete all as specified and directed by Garrison Engineer / Engr-in-Charge.
Supply, install, fixing and commissioning split type air conditioner of capacity 1.5 TR, five star rated inverter type with cordless remote control unit and in built air ioniser, plasma filter for better indoor air quality, star rated suitable for wall mounted, single phase, 230/250 volt AC including breaking necessary hole in wall for fixing indoor and outdoor unit and making good to disturbed surfaces with cement mortar to match with existing finishes after commissioning, making necessary connections unplasticised PVC pipes medium duty 25 mm dia for draining out condensed water all as required including necessary connection complete all as specified and directed by Garrison Engineer / Engr-in-Charge. Note :- (i) Quoted rates deem to be included cost of drain pipe, copper tubing and 4 sqmm multi standard copper cable (all 3 mtr length) , bracket, hole in brick wall etc. (ii) Air conditioner shall be of make Carrier Model No 18K DURAFRESH NEO-X / Daikin Model No : Indoor unit - JTKJ50TV16U, Outdoor unit - RKJ50TV16U / Blue star Model No : DATU / LG Model No : KS-Q18ENZA or equivalent model of make specified in Appendix 'B' to particular specifications. (iii) Installation and commissioning to be done through OEM / its authorised service centre / agency.
Supply and fix ON Load change over switch 415 Volt in sheet metal enclosures four pole of capacity 125 Amps complete all as specified and directed by Garrison Engineer / Engr-in-Charge.
Supply and fix static frequency convertor 208 volts (phase-phase) 3 phase 0.8 pf 400 Hz from 415 volts 50 Hz three phase AC supply with 6 module and all accessories for this convertor complete all as specified and directed by Garrison Engineer / Engr-in-Charge.
Supply, installing, commissioning and testing complete of manufacturer or OEM (Original equipment Manufacturer) manufatured and tested silent static Diesel Engine driven generating set capacity of delivering 35 KVA continuous rating, and at 10% overload for 1 hour in 12 hours continuous operation, 415 volts, AC 3 phase, 4 wire system of supply, 50 Hz at power factor 0.8 minimum, 1500 RPM self exicited self regulated brushless AC generator installed including accoustic enclosures suitable for ambient condition at Gorakhpur and automatic main failure panel confirming to condition under IS 4722/1460, BS 5514/2613/5000 ISO 8526/3046. The DG set shall consist of a diesel engine coupled directly to a matching alternator, and mounted on Dunlop metallastik foundation pads on a common base frame and thereafter installed in the CPCB approved acoustic enclosure complete with control panel standardised by manufacturer, fuel tank with mounting arrangement and inlet, outlet, return oil arrangement, flexible exhaust pipe complete all as specified and shall comprises of the following :- (i) Engine (prime mover) :- Diesel engine 1500 RPM,as per relevant IS/BS - 5514 with an overload capacity 10% overload for 1 hour in 12 hours continuous operation of suitable BHP, fluid cooled, turbo charger, 12 Volts electric one number maintenance free batteries, complete with fly wheel and vibration damper, radiator and all standard fittings/fixtures as per standard manufacturing design practices and including suitable instrument panel with RPM meter, lubricant oil temperature and pressure gauge, water temperature gauge and freqency meter (digital type), battery charging ammeter and fuses, and also including self starter (12 V), battery charging alternator etc and complete with HWT & LLOP alarm and shut down safeties. (ii) Alternator : AC alternator, brushless, 415V, AC 50 Hz, 3 phase, 4 wire type, rated for continuous output of 35 KVA, PF 0.8, 1500 RPM insulation class 'H' enclosure SPDP (IP 23), self excited and self regulated with AVR for ± 1% voltage regulation, coupled directly/suitably to and to match the above engine. The alternator will be suitable for tropoical climate and shall confirm to BS 2613/5000/IS-4722 at Gorakhpur.
(iii) Base plate : Made out of structural steel as per manufacturer's recommended design/specifications. (iv) Fuel tank : Capacity of fuel tank shall be as per manufacturer recommendation (minimum for 12 hours continous run) and provided with level indicator, drain plug, air vent float, gauge and fuel float switch. (v) Safeties : for high enclosures temperature and emergency shut-down from outside. 1 number, 150 AH, 12V lead acid battery and adequate size copper conductor cable leads with terminals. (vi) Engine control panel : Made of 14 gauge CRCA MS sheet, dust and vermin proof, (protection class IP 41 or superior), duly fitted with the equipment/ metres specified in particular specifications. (vii) Automatic mains failure (AMF) control panel : fabricated from minimum 14 gauge CRCA steel sheet (including CPRI type certified), dust and vermin proof, protection class IP -54 suitable for 415 volts, 3 phase, 4 wire, 50 Hz, AC supply system with adequate layers of powder coating floor mounting type with front opening, and panel shall comprises of all necessary accessories as per Manufacturer or OEM including one number onload change over switch 200 Amps four pole 415 volts, 50 Hz with front operated rotary handle for by pass arrangement of electric supply to be fixed by manufacturer in AMF panel. (viii) Platform/Plinth/Base shall be provided as per manufacturers recommendations however minimum 1.00 metre space should be available all around the DG set and height of plinth shall not be less than 0.60 metre and for foundations and finishes refer as per drawing No : CE/ALD/TD-190, Sheet No. 1/1. (ix) Tool kit : Operation and Maintenance catalogue, 2 year spare part list, overhauling manuals, guarantee card etc shall be provided as per manufacturer standard practices.
Supply and fix voltage stabilizer copper wound for automatic operation single phase, naturally air cooled indoor type and designed for input voltage between 130 volt to 300 volts with output voltage stabilized at 230 V ± 2.5% with time delay relay, and suitable for fixing / mounting on wall of capacity 4.00 KVA complete all as specified and directed by Garrison Engineer / Engr-in-Charge. . Note :- (i) Make of voltage stabilizer shall be as per Appendix 'B' to particular specifications.
Taking down carefully sub main, wiring Aluminimum / copper of any size including earth continuity conductor on teak wood batten or conduit and removing from site and making good the surfaces of wall etc to meet the existing finishes etc complete all as specified and directed. Note :- Material retrieved under this item is contractor property and necessary amount as per schedule of credit shall be deducted from the contractor dues.
Taking down existing DB TPN 4 way and DB SPN 8 ways of any capacity and size and removing from site and making good the surfaces of wall etc to meet the existing finishes complete all as specified and directed by Garrison Engineer / Engr-in-Charge. Note :- Material retrieved under this item is contractor property and necessary amount as per schedule of credit shall be deducted from the contractor dues.
M/s Suresh Traders
M/S Rajeev Kumar
M/S SHANKER TRADERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .