Col Sachin Sharma CWE
Military Engineer Services, Commander Works Engineer, Udhampur, PO - Garhi, Udhampur-182121
SPECIAL REPAIR/RENOVATION OF CHAJJA, ROOF PLASTERING, PERIODICAL, TOILET FITTINGS, SEWAGE PIPE LINE, DRAIN, ELECTRIC FITTINGS AND WIRE, DOORS AND WINDOWS REPLACEMENT OF VIDYALAYA BUILDINGS UNDER GE (NORTH) UDHAMPUR
2022_MES_554810_1
CWE/U(N)-66/2022-23
Open Tender
Civil Works
Item Rate
270 days
UDHAMPUR
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹1,000
GE (N) UDHAMPUR
₹2.2 L
Yes
11 Nov 2022
28 Sept 2022
5 Nov 2022
28 Sept 2022
3 Nov 2022
22 Oct 2022
Amount
Taking down cement plaster, any description on brick or stone or cement concrete walls including raking out joints, hacking for key, removing all type of vegetation (like peeple tree etc) scrubbing down with water complete, all as specified and as directed by Engr-in-Charge.
15 mm thick rendering in two layer (10mm + 5mm) on fair faces of brick /concrete on wall including facia chhajja etc.surfaces in cement mortar 1:4 and finished even and smooth without using extra cement including mixing Liquid water proofing compund in the proportion as mentioned in manufacturer's instructions complete all as specified and as directed by Engr-in-Charge. Note : Water proofing compund to be measured and paid for separately as supply only.
10mm thick rendering on fair faces of brick or concrete surfaces in cement mortar 1:6, finished even and fair without using extra cement, complete all as specified and as directed by Engr-in-Charge.
5mm thick rendering on brick or concrete surfaces as in ceiling in cement mortar 1:3, and finish the surface even and fair without using extra cement, complete all as specified and as directed by Engr-in-Charge.
Applying two coat of cement base paint over a coat of alkali resistant primer paint including preparation of newly plastered surfaces of wall, complete all as specified and as directed by Engr-in-Charge.
M&L for applying of old plastered rubbing, stopping of existing treatment applying one coats of cement base paint on old plastered/ unplastered surfaces of wall, including complete all as specified & directed.
Applying two coats of oil bound distemper over and including a coat of primer and 1 mm thick a layer of wall care putty including preparation of new plastered/ unplastered surfaces of wall, complete all as specified & directed by Engr-in-Charge.
M&L for preparation of old plastered or un-plastered surface of walls by brooming down or steel wire brushing,scraping down smoke soot, moulds moss and efflorences salts and trading oil and greasy spots and filling nails marks with compound of wall putty and sand papering and applying one coat of distemper oil emulsion white or tinted, complete all as specified and directed.
M&L for preparation of old plastered or un-plastered surface of ceiling by brooming down or steel wire brushing,scraping down smoke soot, moulds moss and efflorences salts and trading oil and greasy spots and filling nails marks with compound of wall putty and sand papering and applying one coat of distemper oil emulsion white or tinted, complete all as specified and directed.
M&L for preparation new surfaces plastered or unplastered and applying three coats of white wash on ceiling complete all as specified and directed.
M&L for prepartion plastered or unplastered old surfaces of ceiling and applying two coats of white wash, complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floor and in paving not exceeding 15 cm thickness (below or above ground level), complete all as specified and directed.
75mm thick Plain cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregates) as in sub base, complete all as specified and as directed by Engr-in-Charge.
Demolition of Brickwork or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone-work and precast concrete articles complete all as specified and directed.
M&L for brick work with old size sub class 'B' bricks, straight or curved on plan to any radius built in cement mortar 1:6, complete all as specified and directed.
M&L for brick work with old size sub class 'B' bricks, straight or curved on plan exc 6 m mean radius in half brick thick built in cement mortar 1:4, complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutters from frames) area not exceeding 1.50 square metre each, including cutting holes for taking out hold fasts or dismantling brick work (holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt.), complete all as specified and directed by Engineer-in Charge.
Description all as per item No 17 above but area exceeding 1.50 square metre and not exceeding 4 square metre each.
Taking down shutters of any descriptions area not exceeding 1 square metre each and refixing complete all as specified and as directed by Engr-in-Charge.
Taking down shutters of any descriptions area exceeding 1 square metre and not exceeding 2 square metre each and refixing in same opening complete all as specified..
Taking down shutters of any descriptions area exceeding 2 square metre each and refixing complete all as specified and as directed by Engr-in-Charge.
Pressed steel frames for doors, made out of 1.25 mm thick MS sheet, with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc. complete, of frame size 125 mm x 60 mm, including one shop coat of red oxide zinc chrome primer, including filling voids with PCC 1:3:6 type C-0 complete all as specified and as directed by Engr-in-Charge.
Description all as per item No 22 above but frame size 105 x 60 mm.
18/19 mm thick MDF boards grade 2 quality enterior grade, Commercial type, ply wood face pannels and both face is covered with decorative face veneer fixed with screw or Steel fram/Timber frame incl teak wood lipping,6mm thick fixed with Nail complete all as specified and directed.
Extra over rates of block board or veneered particle board for external teak wood lipping, 6mm thick fixed with nails complete all as specified and directed.
35 mm thick, factory made, 2nd class hard wood, plain framed, paneled shutters (two panels) with lock rail and panel of 9 mm BWP commercial ply or 12 mm veneered particle board with commercial veneering on both faces, the size of rail and stile as per IS-1003 (Part-I), kiln seasoned and chemically pressure treated, complete all as specified and directed by Engr in Charge.
35mm thick, factory made 2nd class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete, all as specified and directed by Engr in Charge.
Magnetic catcher of size 50 x 25 mm fixed with stainless steel screws, suitable for cupboard & rubber wood shutter complete all as specified and as directed by Engr-in-Charge.
18-20 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including cutting and polishing over and including 15 mm thick screed bedding/ backing layer in CM 1:3, complete all as specified and as directed by Engineer-in-Charge.
Complete removal of existing treatment by scrapping, washing rubbing down and stopping of old painted steel and iron surfaces exceeding 10 cm width or girth and applying two coat of aluminium paint , complete all as specified.
Preparation of new or previously untreated steel and iron surfaces exceeding 10 cms width or girth and applying two coats of synthetic enamel paint (Ordinary tint) over a coat of primer, complete all as specified and as directed by Engr-in-Charge.
Preparation of new or previously untreated wood and wood surfaces exceeding 10 cms width or girth and applying two coats of synthetic enamel paint (Ordinary tint) over a coat of primer, complete all as specified and as directed by Engr-in-Charge.
Preparation of old painted surfaces of wood and wood surfaces exceeding 10 cms width or girth and applying one coats of synthetic enamel paint (Ordinary tint) over a coat of primer, complete all as specified and as directed by Engr-in-Charge.
RCC M-25 Design mix, (using 20 mm graded crushed stone aggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like all as specified and as directed by Engr-in-Charge. Note: Design/Sectional detail of RCC structure shall be decided by Engr-in-Charge as per ground requirement.
M&L TMT mild steel bars, 8mm dia and over, as in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with and including MS wire (annealed not less than 0.9mm dia) , complete all as specified and as directed by Engr-in-Charge.
Use and waste of form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) etc to obtain rough flat finished surface of concrete complete all as specified and as directed by Engr-in-Charge.
M&L Factory made Machine pressed / vibro mechanically floated coloured interlocking cement paver block ISI marked, any shape and size conforming to IS 15658-2006 of 80mm thickness, M-40 Grade, with topping of cement with imported pigment. Shape shall be approved by Engr-in-Charge.
M&L Sand cushioning under floors including watering and consolidation complete all as specified and as directed.
S&F in repairs steel window (box type) factory made with side hung shutters including pintol hinges, steel handles, steel peg stay and all locking arrangement complete with glazing bars dovetailed or welded including one shop coat of red oxide primer complete all specified and as directed. Notye : i) The window shall be fabricated as per Drg No CEUZ/TD/1269/2008 Sheet 1/3 to 3/3 (ii) MS fillets, glazing, wire gauge shall be measured and paid separately.
Dismantling timber scantlings in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section, complete all as specified and directed.
S&F in repairs 3 mm thick sheet glass ordinary quality and glazing with oil putty or wooden beads in squares not exceeding 0.50 Sqm in each pane complete all as specified.
Mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted or forged into spikes, framed guard bar, barred iron doors; ladder, framed balusters; railing; frame work for water tanks, cooler stand etc and similar work conforming to FE 290-0 or Gde-E-165, complete all as specified and as directed.
M&L Cement concrete 1:2:4 type B-2 (using 40mm graded crushed stone aggregates) in walls or retaining walls, any thickness, size or shape including pilasters, buttresses columns, pillars, boundary pillars and posts (including caps and bases) , complete all as specified and as directed by Engr-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed by Engr-in-Charge.
Glazed ceramic coloured tiles 350mm x 250mm x 7 to 8mm /450 mm x 300 mm x 7 to 8mm thick on vertical surfaces of walls as in dado/skirting etc., set and jointed in neat cement slurry and pointed in coloured cement to match the surface over and including 10 mm thick screed bedding/ backing layer in CM 1:4, complete all as specified and as directed by Engr-in-Charge.
Non skid, coloured ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc, set and jointed in neat cement slurry and pointed in coloured cement to match over and including 15 mm thick screed bed or bedding layer in cement mortar 1:6, complete all as specified and as directed by Engr-in-Charge.
S&F Powder coated (of approved colour ) aluminium sections as in frame & shutter of doors, windows (sliding), ventilators (louvers/fixed type) and fixed frame etc fixed to wall including, preparation of disturbed portion both side (internal & external surfaces of wall) match with existing surface treatment and all sides of aluminium frame shall be sealed with silicon sealent (inner/outer face) including taking down of existing frame complete all as specified as directed by Engr-In-Charge.
S&F Stainless steel mosquito proof wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium flat/channel and screws complete, all as specified and directed by Engr in Charge.
S&F 5mm Sheet glass, tinted/ frosted as approved quality and glazing with rubber neoprene packing for aluminium doors/windows in square/rectangular exc 0.5 sq. m in each pane, complete all as specified and as directed.
S&F 150 mm aluminium anodised, barrel tower bolts of extruded section complete all as specified and directed. (ISI Mark)
S&F 200 mm aluminium anodised, barrel tower bolts of extruded section complete all as specified and directed. (ISI Mark)
S&F Powder coated aluminium anodised, tower bolts hinges 200 mm long match with door shutters fixed to door shutters with screws, complete all as specified and directed. (ISI Mark)
S&F 300mm long mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed, complete all as specified and as directed by Engr-in-Charge.
S&F 200 mm long mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed complete all as specified and as directed by Engr-in-Charge.
S&F Mild steel cold rolled butt hinges medium weight 100 mm log fixed to steel /angle iron frame by welding, if required complete all as specified.
100mm butt hinges ,medium weight ,stainless steel all as complete all as specified and directed.
S&F Aluminium alloy, anodised, Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg complete, all as specified. (ISI Mark)
S&F Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor of overall length of cover plate 150mm, complete all as specified.
S&F 100 mm aluminium handles, extruded aluminium alloy handles, cast type, anodised complete all as specified and directed. (ISI Mark)
S&F 150 mm aluminium handles, extruded aluminium alloy handles, cast type, anodised complete all as specified and directed. (ISI Mark)
S&F Curtain rod, anodised aluminium alloy, chromium plated with fixing brackets, stops, rollers etc. complete all as specified and directed by Engr-in- Charge.
S&F Continuous ( piano) hinges mild steel ,bright finish or electrogalvanised , width of flap (when open ) 30mm , complete all as specified and directed by Engr-in- Charge.
S&F Mild steel, 300 mm, ordinary rat tail rod pattern door spring including roller and roller plate complete all as specified.
Taking up or down steel tubing of 15 mm bore with connections for cleaning for refixing or removing to store yard/from site, complete all as specified and as directed by Engr-in-Charge.
Taking up or down steel tubing of 25 mm bore with connections for cleaning for refixing or removing to store yard/from site, complete all as specified and as directed by Engr-in-Charge.
Taking up or down steel tubing of 40 mm bore with connections for cleaning for refixing or removing to store yard/from site, complete all as specified and as directed by Engr-in-Charge.
S&F 15 mm bore steel water tubing medium grade galvanised with and including all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete with all fittings( such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) complete all as specified and as directed by Engr-in-Charge.
S&F 25 mm bore steel water tubing medium grade galvanised with and including all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete with all fittings( such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) complete all as specified and as directed by Engr-in-Charge.
Description all as item No 68 above but except tubing.
S&F 40 mm bore steel water tubing medium grade galvanised with and including all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete with all fittings( such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) complete all as specified and as directed by Engr-in-Charge.
Description all as item No 70 above but except tubing.
S&F Gun metal globe of gate valve with iron wheel head, screwed both ends of size 25mm fixing in repair,complete all as specified.
S&F Gun metal globe of gate valve with iron wheel head, screwed both ends of size 40mm fixing in repair,complete all as specified.
S&F Fancy towel rail 600mm long,brass chromium plated, complete all as specified and as directed by Engr-in-Charge.
S&F PVC connection 15mm size with PTMT nuts of length 600mm fixed in repair complete all as specified and as directed by Engr-in-Charge.
S&F 600 mm x 450 mm bevelled edge mirror of thickness 5/5.5mm of slected quality glass, mounted on 6 mm thick commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete, fixed in repairs all as specified and as directed by Engr-in-Charge.
Bib taps , fancy type cast copper alloy, chromium plated, with crutch or butterfly handle screwed down for iron pipe or for brass ferrule for bore of pipe 15 mm, fixed in repairs, , complete all as specified and as directed by Engr-in-Charge.
Viterous china wash basin, white flat back size 580 x 450mm excluding traps, waste , chain , plug and porcelain stopper incl CI brackets of iron 65 x 65 x 6mm embedded in PCC block with PCC 1:2:4 type B-1 incl PVC waste pipe 32mm dia & CP grating with holes with pedestal of china ware complete, all as specified and as directed by Engr-in-Charge.
Pillar taps, fancy type, cast copper alloy, with capstan heads, chromium plated, screwed down, high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts, screwed for iron pipe of bore 15 mm, fixing in repair, complete all as specified and as direceted by Engr-in-Charge.
Soap dish, vitreous China white, approximate size 160x 160x90mm complete all as specified and as direceted by Engr-in-Charge.
Stop valves, fancy type, chromium plated, cast copper alloy, with long shank and cup (concealed type) screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions of bore 15mm , complete all as specified and as direceted by Engr-in-Charge.
Dismantling water tank of capacity exceeding 1000 ltrs but not exceeding 2000 ltrs each and removing from site/to store, complete all as specified and as directed by Engr-in-Charge.
Rotational moulded polyethylene water storage tank , two layers, ISI marked (cylinderical vertical with closed top) hoisted with Threaded Cap and fixed in position all as specified in SSR Part-I of Capacity 2000 litres each including all accessories (i.e GI nipples and Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe of bore 20mm/25mm (Minimum weight 210 gram) etc), complete all as specified and as directed by Engr-in-Charge.
Vitreous china water closet, 'Orissa pattern, including lime concrete bedding, size 580 x 440 mm white with integral foot rests excluding flushing cistern and flush pipe but including connection to trap, anti syphonage pipe etc. complete , complete all as specified and as directed by Engr-in-Charge.
10 ltr capacity PVC valveless, symphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets with twin flush provision, fixed in repair complete all as specified and as directed by Engr-in-Charge.
Vitreous China wash down water closet pan and seat cover (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) including P or S trap and including plastic water closet seat, black, closed pattern with flat bottom and cover and mild steel chromium plated or aluminium hinging device, including connection to drain pipe (or out going pipe) and to flushing pipe, antisyphonage pipe, etc. including cast iron 'P' or 'S' trap for 100mm bore of pipe, fixed in repairs complete all as specified and as directed by Engr-in-Charge.
Chipping / removing loose concrete up to reinforcement bars without damaging the reinforcement , removing all the loose materials and to make all the exposed surfaces free from oil dust and all impurities etc. complete all as specified and directed.
Removing corrosion of steel reinforcement by mechanical means like wire brushing, chipping to remove loose rust and then applying rust removal solution by using brush application , leaving the surface for at least 15 to 30 minutes then removing loose materials by scrubbing or with brush and applying polymer bond to the old concrete surface before applying Polymer mortar. Make : “SIKA - SIKA Rust off 100 or SIKA S.B.R or Lalex power” ” FOSROCK – Reebaklens RR or Nitobond AR” or BASF Emaco S420 or equivalent makes mentioned in Particular Specifications.
Application of Corrosion Inhibitor Providing & applying One coat of Concrete Penetrating Corrosion Inhibitor ( Surface applied ) which works on Bipolar Inhibition Mechanism on entire concrete surface to be repaired by using brush or spray at 250 ml per Sq. Mt./ Coat or as per manufacturer's specification and prior to application of first coat of anti corrosive coating to reinforcement. Make:- Sika Sikadur 32 LP/ Fosroc Nitobond EP/ Equivalent in BASF or equivalent makes mentioned in Particular Specifications. Note:- Site for application is at various locations and height varies up to 15.0M Proper stable Scaffolding is must for working
Providing Micro Concrete jacketing to walls / columns or beams of thickness upto 75 mm using Polymer modified cement premixed quartz sand aggregate packed in bags of standard manufacture for high early strength of 40 N / mm sq.cm of approved brand. The dry product is to be mixed with 12.5 % water by weight , along with washed and poured into rigid form work molds & tamped properly & cured for 3 days . [Payment is to be made by weight premixed of micro concrete product consumed as per site register records. No extra payment shall be made for shuttering or any other material, complete all as specified and as directed by Engr-in-Charge. Make:- SIKA – Sika Rep microconcrete - 4” ” FOSROCK – Rendero CRG” or equivalent makes mentioned in Particular Specifications. Note:- Site for application is at various locations and height varies up to 15.0M Proper stable Scaffolding is must for working
Providing and applying Polymer modified cement mortar of average thickness 15 -20mm using Polymer in one or more layers in proportion 1 : 5:15 of Polymer Cement Quartz Sand as manufacturer's specifications in specific layers , curing the surface after 72 hours of application with wet gunny bags etc and by finishing the surface with 12mm thick ( 1:3 ) Cement sand plaster, complete all as specified and as directed by Engr-in-Charge.Make:- SIKA or FOSROCK or BASF or equivalent makes mentioned in Particular Specifications.
Providing and applying Polymer modified cement mortar of average thickness 30-40mm using Polymer in one or more layers in proportion 1 : 5:15 of Polymer Cement Quartz Sand as manufacturer's specifications in specific layers , curing the surface after 72 hours of application with wet gunny bags etc and by finishing the surface with 12mm thick ( 1:3 ) Cement sand plaster, complete all as specified and as directed by Engr-in-Charge.Make:- SIKA or FOSROCK or BASF or equivalent makes mentioned in Particular Specifications.
Shear Connectors: Make 10/12 mm dia holes using heavy duty electrically operated hammer drills in the concrete of RCC members to a depth of about 75 mm at 500 mm c/c or at suitable grid in zig - zag fashion, clean the holes using air jet and fix pre- fabricated 100 x 50 mm L - shape 8 mm dia rebar using Anti Corrosive protective coating so that 75 mm out of 100 mm is inserted inside the concrete and 25 mm remain outside along with 50 mm bend . The shear connectors are used to tie the additional reinforcement bars, complete all as specified and as directed by Engr-in-Charge.Make : FOSROCK – HILTI, Fischer or equivalent in SIKA or BASF or makes mentioned in Particular Specifications.
Bond Coat : Providing & applying One coat of structural grade epoxy bond coat by brush conforming to ASTM - C - 882-87 to the prepared concrete surface to be repaired / strengthened . This is applied prior to the application of polymer repair mortar / epoxy mortar / Microconcrete to have monolithic action between old concrete surface and new concrete surface, complete all as specified and as directed by Engr-in-Charge.Make:- SIKA or FOSROCK or BASF or equivalent makes mentioned in Particular Specifications.
Note:- For items 87 to 94 (i) Work shall be executed only through authorised/approved applicators of the Manufacturer only. (ii) Site for application is at various locations and height varies up to 15.0M (iii) All Scaffolding work and safety measures such as provision of props and supports shall be of steel and extent of provision shall be entire tosatisfaction of GE. (iv) Mode of measurement for items: For the purpose of the measurement of these items the surface area of the patch of the concrete considered of repair shall be taken. (v) Testing of cube strength of polymer modified cementious mortar shall be independantly carried out as per manufacturers instructions and record shall be maintained. (vi) After obtaining approval of the make of the products the contractor shall give a letter from the manufacturer regarding the details of the agency and the name of person to be deployed for carrying out repair & Supervision of the work. (vii) The T&P shall be strictly as per manufacturers instructions. (viii) Necessary Jacks shall be erected to support various floors before exposing columns/ bveams for repair & it shall also be ensured that no damage is made to existing structure during the repair process & all safety norms shall be followed.
Demolition of reinforced cement concrete as in roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work, complete all as specified and as directed by Engr-in-Charge.
Roughening surfaces of old concrete surfaces by picking up, sweeping, cleaning and washing down with water to remove dust etc including taking down tarfelt and brushing neat cement slurry @ 3 kg/Sqm ,providing 15 mm thick rendering in CM (1:3) on RCC roof incl mixed with WPC, applying bituminous primer on roof surfaces @ 0.40 ltr/Sqm and applying one coat of hot blown bitumen of grade 85/25 @ 1.20 Kg/Sqm and provide modified polymeric five layred APP (Atactic Polypropylene) Modified Polymeric Membrane with 100 micron high molecular high density polyethylene film, Min wt of membrane will be 3.5 Kg/Sqm and bonded completely to the surfaces with min end overlap of 15 cms and side lap 75 mm (overlaps to be bounded with thermo fused by flame) and over APP applying one coat of hot blown bitument 85/25 @ 1.2 Kg/Sqm blinded with fine sand in dry condition @ 0.5 Kg/Sqm, complete all as specified and as directed by Engr-in- Charge.
Material and labour 40mm plain Cement concrete type B-0, 1:2:4 (12.5mm aggregate) in two layer (each 20mm), in leveling course as in roof including chiken wire mesh size of 20mm X20mm and thickness of mesh 0.91 mm provide between the layer of PCC and even and smooth with false grooves at 450x450mm, complete all as specified and as directed by Engineer-in charge.
M&L Chequered reflective ceramic tiles of size 30cm x 30cm and 10mm thick, machine pressed; set jointed and pointed in neat cement slurry with grey cement as in roof/floor, and cut and polished , over and including 15 mm thick screed bed or bedding layer in cement mortar 1:6 for laying floor finishes, complete all as specified and as directed by Engr-in-Charge.
Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples, complete all as specified and as directed by Engr-in-Charge.
Supply only Integral water proofing compound, complete all as specified and as directed by Engr-in-Charge.
Excavating in trenches, n exc 1.5 m wide and n.exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, for laying cables/pipes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth in any type of soil, complete all as specified and as directed by Engr-in-Charge.
Excavation over areas exceeding 1.5 metre not exceeding 3.0 metre deep and getting out in any type of soil, complete all as specified & as directed.
Returning, filling in (soil) including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick in any type of soil, complete all as specified and as directed by Engr-in-Charge.
Removing excavated material exc. 250m and depositing where directed at a level n exc. 500 m above the starting point, complete all as specified and as directed by Engr-in-Charge.
Plain cement concrete (1:5:10) type E2 using 40mm graded stone aggregate as in foudation, filling, sub base and mass concrete all as specified.
Plain cement concrete 1:2:4 type B-2 (using 40mm graded crushed stone aggregates) as in surface channels and drains including necessary form work, complete all as specified and as directed by Engr-in-charge.
Plain cement concrete 1:2:4 type B-0 using 12.5mm graded crushed stone aggregates as in coping, benching and similar work etc including necessary form work complete all as specified and as directed by Engr-in-Charge.
Brick work with old size sub class 'B' bricks, straight or curved on plan exc 6 m mean radius built in cement mortar 1:4, complete all as specified and as directed by Engr-in-Charge.
Description all as per item No 109 above but except bricks.
Demolition & breaking up SGSW drain pipes of 100 bore pipe, complete all as specified and as directed by Engr-in-Charge.
M&L for HDPE DWC ( Double wall corrugated) pipes confirming to IS - 16098 of 100 mm internal dia pressure ratting SN - 08 fixed with rubber seal and coupler required with and including suitable bends 90/60/45 degree etc. single Y Jncomplete all as required fixed as per manufacturing instructions laid in treches for sewage line complete with collars, complete all as specified and as directed by Engr-in-Charge.
Demolition & breaking up SGSW drain pipes of 150mm bore pipe, complete all as specified and as directed by Engr-in-Charge.
M&L for HDPE DWC ( Double wall corrugated) pipes confirming to IS - 16098 of 170 mm internal dia pressure ratting SN - 08 fixed with rubber seal and coupler required with and including suitable bends 90/60/45 degree etc. single Y Jncomplete all as required fixed as per manufacturing instructions laid in treches for sewage line complete with collars, complete all as specified and as directed by Engr-in-Charge.
Demolition of Reinforced Cement Concrete (reinforcement cut as required to facilitate demolition) of any description and in any position not otherwise specifically provided for, complete all as specified and as directed by Engr-in-Charge.
Plain cement concrete 1:3:6 type C-2 (using 40mm graded aggregate) as in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for 150mm bore pipes all as specified. Note:-(i) Thickness of bed below barrel of pipe-10 Cms. (ii) width of bed- outer dia of pipe plus 30 cms.
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as requiredcomplete all as specified and directed.
Taking down eaves gutters and rainwater pipes/soil pipes (any size, type or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., for (measured overall as fixed along the centre line over fittings and accessories), complete all as specified and as directed by Engr-in-Charge.
110mm bore, PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls, fixed in repairs, complete all as specified and as directed by Engr-in- Charge.
110mm bore, PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors, complete all as specified and as directed by Engr-in- Charge.
Refixing only 110mm bore, PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls but Except pipe, complete all as specified and as directed by Engr-in- Charge.
110 mm bore PVC SWR bends any radius with acess door and fixed solvent etc complete all specified and as Directed (ISI Marked)
Dismantling cast iron work of any description, complete all as specified and as directed by Engr-in-Charge.
Cast iron soil, waste and vent pipes (Sand cast pipes) in any length with or without ears, with cement joints laid in trenches or in floors of 100mm bore, complete all as specified and as directed by Engr-in-Charge.
Description all as per srl item No 124 above but except pipes, with clamps complete all as specified and as directed.
Cast iron soil, waste and vent pipes (Sand cast pipes) in any length with or without ears, with cement joints laid in trenches or in floors of 75mm bore, complete all as specified and as directed by Engr-in-Charge.
Description all as per srl item No 126 above but except pipes, with clamps complete all as specified and as directed.
Cast iron vent cowl for 100mm bore pipe, complete all as specified and as directed by Engr-in-Charge.
100mm Cast iron floor traps with grating including jointing to waste pipe fixed cncrete type B1 (1:2:4), complete all as specified and as directed.(ISI Mark)
Cast iron branch pieces, single/double (equal or unequal) ordinary or inverted (spigot or socket type) or with parallel branches 100 bore, fitted with oval access door as in repairs complete all as specified and as directed.
Cast iron branch pieces, double (equal or unequal) ordinary or inverted (spigot or socket type) or with parallel branches 75 bore, fitted with oval access door as in repairs complete all as specified and as directed.
Systematically cleaning of the water closer including nahani trap, floor trap and gully traps by bambo0 / wire / kandi rotary cleaner up to first manhole any type of die, complete all as specified and as directed by Engr-in-Charge.
Systematically cleaning of the sewage lines including gully traps by passing ropes , Knots bamboo / wire / kandi rotary cleaner etc for any type of dia of sewage pipe, complete all as specified and as directed by Engr-in-Charge.
Cleaning and desludging of manholes of any size, shape and any depth including pumping out liquid waste if any, removing all solid waste materials such as stones bricks , pipes , plastic etc pluggings / diverting of flow if required and removing the debries outside MD land etc including all precautionary and safty measures, complete all as specified and as directed by Engr-in-Charge.
Cleaning and desludging of existing mini septic lank or Manholes or gully trap of capacity n exc 10 Users and including inlet and outlet chambers and soakage well, taking out sludge in any form alongwith all other foreign materials by mechanical equipment or by way of other suitable means and removing waste material / sludge ( desludging n exc 0.5 cum and dewatering n exc 0.5 cum from each septic tank ) etc to a distance n exc 50 mtr including digging burying in ground Complete all as specified and as directed. Note: (i) Work shall be done in foul conditions, necessary precautionary measures / equipment to be adopted by the contractor. (ii) The solid or semi solid sludge shall be burried in pits and fully covered with a layer of lime powder and earth. (iii) Rates quoted by the contractor shall be deemed to have considered all such contingencies including removal and refixing man hole covers.. ( iv ) Any damage caused during cleaning shall be made good by the contractor to the entire satisfaction of Engr- in-Charge without any extra crist to Govt.
Same as item No. 135 above but 300 users capacity ( desludging n exc 12.0 cum and dewatering n exc 12.00 cum from each septic tank ) complete all as specified and as directed by Engr-in-Charge.
Pre-cast RCC cement concrete 1:2:4 type B-1 (20mm graded) as in manhole cover slab and in similar works bedded and jointed in cement morter 1:6, complete all as specified and as directed by Engr-in-Charge.
Taking down carefully copper /aluminium, point wiring (light, fan, socket or power) complete including fittings and fixtures such as light fittings, switches, ceiling roses, pendants, regulators, sockets etc. and making good disturbed surfaces of wall, ceiling, floors etc, complete all as specified and as directed by Engr-in-Charge.
Dismantling and taking down fluorescent tube light single / double of any wattage or size street light fittings for repair or replacement of burnt / worn out accessories or carrying to MES store for reuse or taking in schedule of credit ( Accessories or components to be provided free for replacement by department ), complete all as specified and as directed by Engr-in-Charge.
Taking down unserviceable / serviciable MCB DB's / AC's box to deposit in store for keeping in safe custody for reuse or taking in schedule of credit of any size / rating, complete all as specified and as directed by Engr-in-Charge.
Point wiring with 1.5 Sqmm PVC insulated, unsheathed (FRLSH) cable with multi stranded copper conductor wiring in and including PVC concealed conduit medium grade (ISI marked) 20mm dia and over, wall thickness not less than 2.00 mm thick , and all accessories for one light / bell controlled by one switch with 1.25mm thick pressed steel terminal anodized box concealed on walls, 3mm laminated plastic sheet cover for mounting of switches, socket outlet, regulator etc or suitable for modular type switches, socket outlet, regulator etc , fixed by suitable size of 4 Nos cadmium screws along with PVC insulated and unsheathed FRLSH 1.5 Sqmm multistrand copper conductor earth wire connected to common earth and earth dolly, complete all as specified and as directed by Engr-in-Charge.
Point wiring with 1.5 Sqmm PVC insulated, unsheathed (FRLSH) cable with multi stranded copper conductor wiring in and including PVC concealed conduit medium grade (ISI marked) 20mm dia and over, wall thickness not less than 2.00 mm thick , and all accessories for one fan/Bell point/exhaust controlled by one, one way switch with 1.25mm thick pressed steel terminal anodized box concealed on walls, 3mm laminated plastic sheet cover for mounting of switches, socket outlet, regulator etc or suitable for modular type switches, socket outlet, regulator etc , fixed by suitable size of 4 Nos cadmium screws along with PVC insulated and unsheathed FRLSH 1.5 Sqmm multistrand copper conductor earth wire connected to common earth and earth dolly, complete all as specified and as directed by Engr-in-Charge.
Description all as per item No 141 above but one 3/5 pin 5 Amp socket outlet on the same board with other switch.
Description all as per item No 141 above but one 3/5 pin 5 Amp socket outlet on independent board .
Description all asper item No 141 above but one 3/5 pin 15 Amp socket outlet on independent board with PVC insulated, unsheathed FRLSH cable 2.5 Sqmm copper multistrand conductor, along with PVC insulated and unsheathed FRLSH 2.5 Sqmm multistrand copper conductor earth wire connected to common earth and earth dolly complete all as specified and as directed by Engr-in-Charge.
Description all as per item No 141 above but one 3/5 pin 15 Amp socket outlet on independent board with PVC insulated, unsheathed FRLSH cable 4 Sqmm copper multistrand conductor for AC point, along with PVC insulated and unsheathed FRLSH 4 Sqmm multistrand copper conductor earth wire connected to common earth and earth dolly complete all as specified and as directed by Engr-in-Charge.Note: Rates are deemed to be inclusive of chases of conduits and sunking of single pole and neutral enclosure boxes, cutting and making holes in wall/floors for passing in or through conduits from DB to existing location and making good the distubed surfaces to match with existing specifications , complete all as specified and as directed.
Switch socket outlet, 2 in 1, 3 pin, 5 Amp flush type, complete all as specified and as directed by Engr-in-Charge.
Socket outlet, 6 pin, 5 &15 Amp flush type, complete all as specified and as directed by Engr-in-Charge.
Sheet metal enclosure single pole & neutral with 2 pin and earth plug and socket 20Amps, 240V complete with one single pole MCB of any cap from 5 to 32 Amps of breaking capacity 10KA, complete all as specified and as directed by Engr-in-Charge.
Switch piano flush button single pole one way 5 Amp, 240 Volts, complete all as specified and as directed by Engr-in-Charge.
Switch piano flush button single pole one way 15 Amp, 240 Volts, complete all as specified and as directed by Engr-in-Charge.
Sheet metal enclosures for distribution board when MCB to be used SPN 12 way with IP-43, IK-09 protection 240V with 200 Amps rated bus bar, double door type including cutting chases in walls for fixing DBs making good the distubed surfaces to match with existing specifications ,fixing in repairs complete all as specified and as directed.
MCB SPN, 40 to 63 Amps,240 Volts, rupturing capacity 10 KA "C" Curve including providing aluminuium thimbles for outgoing cable, complete all as specified and as directed by Engr-in-Charge. Note : The exact capacity of MCB shall be as directed by Engr-in-Charge.
MCB SP, 6 to 32 Amps,240 Volts, rupturing capacity 10 KA "C" Series including providing aluminuium thimbles for outgoing cable , complete all as specified and as directed by Engr-in-Charge. Note : The exact capacity of MCB shall be as directed by Engr-in-Charge.
Decorative ultra slim linear surface mounted LED lighting fixture (4 feet length), 20Watt LED with integral electronic driver complete making connection and testing after fixing all as specified and directed by Engr-in-charge.The specification of light fitting should meet the following : - (a) Housing of Light fitting : Aluminium Extruded (b) Operating Voltage : Between 150 V- 270V (c) Operating Temperature : -10 to +45 Degree Centigrade (d) Lumen efficacy : Not less than 110 lm/W (e) System Lumens : Not less than 2000 lm (f) Colour Temperature : Not less than 5700K (g) Surge Voltage Protection : Up to 2KV (h) Ingress protection : IP 20 (j) Total Harmonic Distortion (THD) : Not less than 20% (k) Power factor : Not less than : 0.90 (l) Line protection : Under/Over voltage Protection (m) Input Frequancy : 50 Hz
Decorative ultra slim linear surface mounted LED lighting fixture (2 feet length), 12 Watt LED with integral electronic driver complete making connection and testing after fixing all as specified and directed by Engr-in-charge.The specification of light fitting should meet the following : - (a) Housing of Light fitting : Aluminium Extruded (b) Operating Voltage : Between 150 V- 270V (c) Operating Temperature : -10 to +45 Degree Centigrade (d) Lumen efficacy : Not less than 100 lm/W (e) System Lumens : Not less than 1000 lm (f) Colour Temperature : Not less than 5700K (g) Surge Voltage Protection : Up to 2KV (h) Ingress protection : IP 20 (j) Total Harmonic Distortion (THD) : Not less than 20% (k) Power factor : Not less than : 0.9 (l) Line protection : Under/Over voltage Protection (m) Input Frequancy : 50 Hz
Sub main wiring with two runs of 2.5 Sqmm ( 2x2.5 sqmm ) 1100 volts grade single core FRLSH PVC insulated unsheathed multistranded copper conductor conforming to IS-694 drawn through and including non-metalic PVC rigid conduit 25 mm dia medium grade (ISI marked) with all conduit accessories mounting on suface of walls /roofs / ceiling etc with one run of 2.5 Sqmm (1x2.5sqmm ) single core FRLSH PVC insulated unsheathed copper conductor cable as earth wire, in repair, complete all as specified and directed by Engr-in-Charge. Note:- 2 runs of 2.5 Sqmm (2x2.5sqmm ) ,one run of 2.5 Sqmm (1x2.5 sqmm ) cable and one metre of conduit will be measured as one unit.
Sub main wiring with two runs of 10 Sqmm ( 2x10 sqmm ) 1100 volts grade single core FRLSH PVC insulated unsheathed multistranded copper conductor conforming to IS-694 drawn through and including non-metalic PVC rigid conduit 25 mm dia medium grade (ISI marked) with all conduit accessories mounting on suface of walls /roofs / ceiling etc with one run of 10 Sqmm (1x10sqmm ) single core FRLSH PVC insulated unsheathed copper conductor cable as earth wire, fixed in repair, complete all as specified and directed by Engr-in-Charge. Note:- 2 runs of 10 Sqmm (2x10sqmm ) ,one run of 10 Sqmm (1x10 sqmm ) cable and one metre of conduit will be measured as one unit.
Taking down and fixing only ceiling fans after painting and Necessary repairs / servicing including replacement of hanging assembly , bush bearing , U/S capacitor , flexible copper cord three core PVC sheathed of size 23 / 0.0076 of required length from ceiling rose or connector to ceiling fan for giving connection complete all as specified and as directed by Engineer - in - Charge .
Ceiling rose, surface bakelite 65x 50mm two to three terminals fixed on PVC Round Block, complete all as specified and as directed by Engr-in-Charge.
Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.0mm thick buried directly in ground, (Earth pit not less than 2.25 mtr deep below ground level) with top edge of plate not less than 1.5 mtr below normal ground level, connected to and including 4 mm dia galvanised earth lead wire by means of bolts, nuts, check nuts and washers of galvanised standard iron or steel all as specified or indicated in electrical plate no 3 of MES Part-I, including testing on completion including the material and labour of the following :- (a) Excavation and earth work for drilling hole for electrode in any type of soil. (b) PCC pit in cement concrete 1:2:4 type B-1. (c) Precast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than 1.87 Kg/Sqm. (d) Funnel with watering pipe of GI 20 mm nominal bore medium grade and copper lugs etc all as specified.
Srl item No 161 Contd … (e) 15 mm nominal bore light grade GI protection pipe 5 mtr long for protection of earthing lead from mechanical injury or tempering. (f) Requisite quantity of common salt and charcoal. (g) Testing of earthing. Note : (a) On testing after completion of earthing, if the desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk and cost to the entire satisfaction of the Engineer-in-Charge.
Stepped type fan regulator 300W, 230V 50 C/S, electronic, hum free suitable control speed of fan from 0 to 100 % and connecting electrically complete all as specified and as directed by Engr-in-Charge.
S&F sheet metal TPN DBs - DPX3 200 MCCB DBs 04 way ( DPX³ 200 + 12 ) with metal door 415 volts grade IP 43 Protection Grade fixed flush to wall complete including connections should be provide with necessary reducer lugs, complete all as specified and as directed by Engr-in-Charge.
S & F DPX3 thermal msgnetic MCCB 4 pole 200 Amp 415 Volts 16 KA including making necessary arrangement all as specified and directed by Engineer.
S & F in repair MCB SPN 63 Amps , 240 Volts, complete all as specified and as directed by Engr-in-Charge.
Supply and fixing LED flood light 70 Watt 230V AC outdoor type with thermal management in multiple optic and equipped with IP66 protection , with impact and corrosion resistant complete with driver and lamp, complete all as specified and as directed by Engr-in-Charge.
New generation energy saving and environmental friendly long life LED street light of 35 watt with high power LED as lighting source and lens embedded PC cover having TOP OPENING seperate driver compartment and impact resistance of IK07 with High efficiency long life LED with SMD LED on MCPCB Powered by Built-in, isolated electronic LED driver (SMPS based constant current supply) complete making connection and testing after fixing, fixed in repair complete all as specified and directed by Engr-in-charge. The specification of light fitting should meet the following : - (a) Housing of Light fitting : Aluminium Die Cast (b) Diffuser : High efficient LENS Optics (c) Operating Voltage : Between 140 V- 270V (d) Operating Temperature : -10 to +50 Degree Centigrade (e) Lumen efficacy : Not less than 100 lm/W (f) System Lumens : Not less than 2500 lm (g) Colour Temperature : Not less than 5700K (h) Surge Voltage Protection : Up to 4KV (j) Ingress protection : IP 65 (k) Total Harmonic Distortion (THD) : Not less than 20% (l) Power factor : Not less than 0.9 (m) Line protection : Under/Over voltage Protection (n) Input Frequancy : 50 Hz
Street light Bracket complete made of GI pipe, light grade of suitable size, 1.2m long bent to shape as per site requirement alongwith MS flat iron clamps with nuts, bolts, washers including grouting the same with wall , complete all as per the direction of Engg-in-Charge.
M & L for earthing in repair complete with galvanized steel earth electrode 60cmX60cmx6 mm thick buried directly in ground ( earth pit not less than 2.25m deep below ground level ) with top edge of the plate not less than 1.5m below normal ground level connected to earth lead by means of bolts nuts and washers of GI steel and including earthing pit charcoal , common salt , GI 25X4mm strip as earthing lead 20mm GI medium grade watering pipe 15mm bore light grade protection pipe 5 Mtr length with wire mesh and funnel PCC pit in PCC 1 : 2 : 4 type B - 1 using 20mm graded stone aggregate , angle iron frame and RCC cover and earth work complete all as shown in electrical plate No.3 of SSR 2009 ( Part - 1 )
Taking down care fully old electric panel by descrewing from wall after all incoming and outgoing connections and making good all disturbed surface of wall including taking out all energy meters and MCCB 200 Amps four pole without damaging for fixing in new panel complete all as directed
supply and installation testing and commissioning factory made LT control panel board of adequate size totally enclosed front opening type cubical; floor mounted and indoor type made out of 2.00 mm thick MS sheet with base frame of angle iron of size 0.90x0.60x0.45 mtr thick provided with copper bus bar - 04 nos with colour coated sleeves of capacity 1.5 times of incommer and internal wiring with PVC insulated copper conductor cable of adequate size for making connections to various eqpts / accessories incl powder coated painting ( internal & externally ) complete over a coat of red oxide primer all as specified CPRI approved and with PCC foundations complete with consisting of the following accessories : ( a ) Fixing only electric meters with complete -08 Nos properly isolated from panel body by means of providing backelite sheet not less than 3.00 mm thick as base plate cable connections ( b ) S & F MCCB 200 Amp TPN Four pole 415 Volt- 08 Nos ( c ) S & F MCB TPN 40 to 63 Amp 415 Volt - 08 Nos ( d ) S & F RYB indicator ( set of three ) -01 sets ) .
Supply and lay in replacement XLPE Insulated screened PVC bedded , galvanized steel strip or wire armoured , electric power cables ( heavy duty ) 1100 Volts grade with stranded aluminum conductor of size 70 sq mm 3.5 core in trenches / floor / pole / Gl pipe complete including cutting / chasing to any surface and making good to the disturbed surface to match the existing , complete all as specified and as directed by Engr-in-Charge.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point, complete all as specified and as directed by Engr-in-Charge.
Dry coarse sand as cushioning to under ground cable provided with layer of 8 cms deep before laying the cable and 15 cms deep after laying and stretching the cable, punned to 18 cm thick complete all as specified and as directed. NOTE Only punned thickness shall be measured for payment purpose.
Sub class ‘B’ old size well burnt bricks, laid flat with width equal to length of brick in trenches as protection to cable complete all as specified and as directed.
GI tubing light grade 70mm bore along the wall/in trenches/in duct/in culvert/road crossing and including provisioning of suitable mild steel flat iron clamps and bolts, nuts and double washers etc for holding of GI pipe alongwith poles complete all as specified and as directed by Engr-in-Charge.
M&L for bore hole for passing of cable through / insection of 40/80 mm dia Gl pipe under PCC / Road / Taxy Track / Runway / Hardstanding not less than 1200 mm deep complete all as directed. Note:- (i) Cost of equipments , tools and plants , material required for boating shell be deemed to be included in unit quoted rate above . (ii) Cost of GI pipe 50/80 mm dia shell be deemed to be included in unit quoted rate above . (iii) Cost of air compressor for boating shell be deemed to be included in unit quoted rate above .
Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube in opening as per specification & drawing, complete all as specified and as directed by Engr-in-Charge.
Factory Made Solid PVC Moulded Door Shutter wall nut colour, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, with particle board core, supplying & fixing in frame at site as per specification & drawing as per specification & drawing, complete all as specified and as directed by Engr-in-Charge.
Note:- For items 01 to180 The quoted rates shall be deemed to include for items of surfaces finshes of Bldg upto G+3 height above all external/ internal surface finishes and include the following:- 1. Use of all scaffolding, trestles, ladders, cradles etc. necessary for execution of work and protective measures. 2. Removing of nails, making good holes, cracks etc. 3. Work in patches, and in narrow/ widths, bands, cornices, plasters etc and cutting in edges to line where necessary. 4. Spreading and removing covering to doors, windows, floors, fitting etc to protect them from splashes. 5. Removing and replacing furniture, movable cupboard, chicks, blinds, etc washing floors, cleaning glass, joinery, electric fittings, wiring, etc of drops and splashes and leaving premises, clean and tidy followed.
M/S VED PARKASH GUPTA
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .