| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.8 LAccepted-AOC 10 2 NARAYAN BAG INDORE M P | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹36.9 L+₹1.1 L (3.10%)Rejected-Finance | L2 | Rejected-Finance Being not lowest | |
| 3 | L3₹38.9 L+₹3.2 L (8.88%)Rejected-Finance | L3 | Rejected-Finance Being not lowest |
| Sl No | Description | Qty | Unit | Ms Kailash Chandra Babulal L2 | AGARWAL BUILDERS L3 | S.S. Engineers L1 |
|---|---|---|---|---|---|---|
| 1.00 | Excavating in trenches, in any type of soil not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, etc or not exceeding 10 Sqm on plan and not exceeding 1.5m in depth for shafts, cesspits, manholes, pier holes, etc and getting out in any type of soil complete. | 668.25 | CUM | 85 ₹56,801.25 Lowest | 110 ₹73,507.5 | 120 ₹80,190 |
| 2.00 | Description all as per item No 1.00 above but for each additional 1.5 m or part thereof in depth beyond the first 1.5 mtr | 1.62 | CUM | 100 ₹162 Lowest | 200 ₹324 | 140 ₹226.8 |
| 3.00 | M&L for Cement concrete 1:2:4 type B 2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete all as specified and directed. | 0.16 | CUM | 3,500 ₹560 Lowest | 6,000 ₹960 | 3,800 ₹608 |
| 4.00 | M&L for Cement concrete 1:4:8 type D 2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete all as specified and directed. | 0.16 | CUM | 2,800 ₹448 Lowest | 3,000 ₹480 | 3,200 ₹512 |
| 5.00 | M&L for Cement concrete 1:3:6 type C 1 (using 20 mm graded stone aggregate) as in roof kerbs or pole coupling of size 300x300 mm or chamfered on edges all as specified and directed. | 1.52 | CUM | 3,000 ₹4,560 Lowest | 4,000 ₹6,080 | 3,400 ₹5,168 |
| 6.00 | Returning, filling in excavated approved soil, including spreading, leveling, watering and well ramming in layers not exceeding 25cm each complete. | 358.18 | CUM | 30 ₹10,745.4 Lowest | 40 ₹14,327.2 | 580 ₹2,07,744.4 |
| 7.00 | Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete. | 310.07 | CUM | 30 ₹9,302.1 Lowest | 40 ₹12,402.8 | 38 ₹11,782.66 |
| 8.00 | M&L Sand cushioning with locally available dry unwashed sand in trenches for protection of cables complete.all as specified and as directed. | 239.64 | CUM | 600 ₹1,43,784 | 700 ₹1,67,748 | 38 ₹9,106.32 Lowest |
| 9.00 | S& F Old size sub class ‘B’ bricks, laid in trenches as cable covers complete | 19.8 | 1000 Nos | 5,500 ₹1,08,900 | 5,500 ₹1,08,900 | 5,000 ₹99,000 Lowest |
| 10.00 | Supply and fixing Steel tubes, galvanised, light grade, ISI marked 40mm bore for protection of cable under floor, road and on wall complete. | 60 | RM | 300 ₹18,000 | 400 ₹24,000 | 280 ₹16,800 Lowest |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
10 Jul 2025, 6:00 pmClosed
GE AWC MHOW
GE AWC MHOW
REPAIR/MAINT OF LT DISTRIBUTION SYSTEM, SUBSTATION AND CONNECTED ITEMS IN OTHER THAN AREA OF AWC UNDER GE (AWC) MHOW
2025_MES_711257_1
88365(AWC) /MHOW / OF 2025-26
Open Tender
Civil Works
Item Rate
180 days
GE AWC MHOW
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE AWC MHOW
₹80,000
21 Aug 2025
29 May 2025
12 Jul 2025
29 May 2025
10 Jul 2025
17 Jun 2025
Amount
Excavating in trenches, in any type of soil not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, etc or not exceeding 10 Sqm on plan and not exceeding 1.5m in depth for shafts, cesspits, manholes, pier holes, etc and getting out in any type of soil complete.
Description all as per item No 1.00 above but for each additional 1.5 m or part thereof in depth beyond the first 1.5 mtr
M&L for Cement concrete 1:2:4 type B 2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete all as specified and directed.
M&L for Cement concrete 1:4:8 type D 2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete all as specified and directed.
M&L for Cement concrete 1:3:6 type C 1 (using 20 mm graded stone aggregate) as in roof kerbs or pole coupling of size 300x300 mm or chamfered on edges all as specified and directed.
Returning, filling in excavated approved soil, including spreading, leveling, watering and well ramming in layers not exceeding 25cm each complete.
Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete.
M&L Sand cushioning with locally available dry unwashed sand in trenches for protection of cables complete.all as specified and as directed.
S& F Old size sub class ‘B’ bricks, laid in trenches as cable covers complete
Supply and fixing Steel tubes, galvanised, light grade, ISI marked 40mm bore for protection of cable under floor, road and on wall complete.
Supply and fixing Steel tubes, galvanised, light grade, ISI marked 80 mm bore for protection of cable under floor, road and on wall complete.
M&L for dismantaling of old cracked /unserviceable PCC poles /MS pole struts any type and size incl deposited at a suitable locations not more than 50 RM away complete all as specified and as directed .
Supply and fix Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 ,9.0 metres long comlete all as specified and as directed .
M&L for attending external electric complaints by opening / disconnecting the electrical connection of defective / burnt out underground LT cable of any size & any core from main switch / DB / junction box / LT panel / L T O/H line etc. and taking out the required length of cable from existing loop and remove/ cut the defective cable,replace the same with new cable as per existing size including providing necessary thimbles / connectors at cable end and reconnecting the cable in previous location with existing main switch / DB / Junction box / LT panel / OH line etc. and make electic connection as functionable in all repspects including testing on completion all as specified and directed. Note:- (A) The rate quoted shall deemed to be inclusive of the following: (i) Necessary earth work excavation in any type of soil, returning, filling and removing extra soil. (ii) Existing bricks, sand,GI protection pipe etc. shall be removed carefully and stacks neatly near site and same shall be re- laid after attending fault/defect. (iii) Distrubed surface of road, floor etc. shall be make good to match with existing surface. (iv) Minimum two numbers of electrician and two numbers of helpers shall be deployed for attending complaints regulerly on daily basis and contractor shall collect the complaints details from complaint cell of AGE E/M No.2 and same shall be rectified/ attanded within an hour and report shall be submitted to Engineer-in-charge or their authorised representative. (B) Please note that payment shall be made to contractor one time only for this items. if any fault/ default occured again on the same location/ DB/junction box/panel during currency of contract, the same shall be rectified by the contractor without any extra cost to Govt. in terms of condition 46 of IAFW of genral condition of contracts. (C) Additional bricks,sand,GI pipe etc. as required for cable protection and cushioning shall be measured and paid separetely under relevent item.
M&L for dismantling / disconnecting / removing the faulty / burnt out overhead conductor of any type / size from insulator of HT / LT pole any type by making proper shutdown from department and removing of tree / branches if any fell on Over Head Line, loose the binding wire in each insulators and disconnecting cable connection as required, remove the burnt / damage conductor / earth wire and making necessary joint with new ACSR conductor of suitable size as per existing as directed, restretching all the loose spans of ACSR conductors, earth wire etc. with insulator and providing binding wire of existing size to tigheting and making LT/HT cable in existing position and make electric connection as functionable in all respects including testing on completion allas specified and directed by Engineer in charge. Note:- The rate quoted shall deemed to be inclusive of the following:- (i) Tools and plants such as ladder,rope, cutter, axes, knife etc. as required for cutting and removing tree/branches if any fall on OH line. (ii) Insulator,binding wire etc. as required in addition to existing shall be provided by the contractor. (iii) Minimum two numbers of electrician and two numbers of helpers shall be deployed for attending complaint regularly on daily basis and contractor shall collect the complaint details from complaint cell of AGE E/M No. 2 (iv) Additional ACSR conductor and earth wire shall be measured and paid separetely under relevant items.
Supply and fixing in replacement for LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.
Supply and fixing in replacement for LED street light fitting 120 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.
Supply and fix LED driver of capacity 60/70 watts rating 240 Volt, 50 Hz complete all as specified Make:- Philips, Bajaj, Havells
Supply and fix in repair of 40 watt All-In-One Solar Street Light is compact & Fully integrated Intelligent designed Luminaire with Lithium Ferro Phosphate battery, solar panel and charger built into the luminaire,100% Solar Powered, 100% Energy saving,Solar panel Dusk to dawn Operation with Short circuit protection, Over charge protection, Deep discharge protection, Reverse voltage polarity protection and PV reverse voltage polarity protection,Modern portable Off Grid Connection design can be installed anywhere.Rust-proof Aluminum Extrusion housing, dust proof and waterproof,Solar Differential dimming profile : First 0 to 2 Hrs - 100%, Next 2 to 4 Hrs - 60%, Remaining Hrs - 30%,Luminaire efficacy* >150lm/w,Correlated Color Temperature 5665±355K,Color Rendering Index >70,Maintenance of lumen output 50,000 hrs.Operating Temperature Range -10°C to 50°C , Beam Angle 135° x 85° ,Charge controller MPPT ,Charge controller Efficiency >90% ,Autonomy** 2Days with Differential Dimming ,Charging Time# 1 day ,Ingress Protection IP 65 ,Impact Protection IK 07,Product Dimensions (AXBXC)(mm) 1012 x 500x 55 , MINUMUM weight should be 22 kg ,Luminous flux (lm) 6000lm, Solar panel 70Wp (Mono) 18V ,Battery-LiFePO4 460 Wh.
Taking down old unserviceable capacitor of any capacity and replace with new Duca Power XD capacitor, withstand Harmonic overloads upto 4 Amp Max current, low losses 0.2 watt/KVAR, three phase, temperature range (-) 25 degree centigrate to 70 degree centigrate of the following rating :-
(a) 1 KVAR
(b) 2 KVAR
(c) 5 KVAR
(d) 10 KVAR
(e) 25 KVAR
Trimming/pruning of tree branches touching to the LT over head line or near to the LT over head line as per direction of AGE E/M /JE in charge complete including removing the tree branches from site complete all as specified and directed . NOTE - (a) Prior shut-down shall be obtained from concerned JE / AGE E/M before taking out the trimming work , by contractor (b) span from one pole to next pole (30 to 50 m) will be considered as a job. (c) T & P such as ladder , rope, cutter , axes and safety of workmen, will be provided by the contractor
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular of size 10 sqmm.
S & F in replacement XLPE insulated and PVC armoured heavy duty electric cables with aluminum conductor, 1100 volt grade of size 10 sqmm,4.0 core in trenches/through pipes/ducts or on poles/walls jointing to O/H conductor, LT panels, main switch with suitable size aluminum lugs and testing complete all as specified & directed for the following sizes:- Note : (a) Excavation shall be measured and paid seperately under respective items of Sch 'A' . (b) All redq lugs of suitable sizes according to laying of cable measured and paid seperately under respective items of Sch 'A'
Description all as above Item No. 23.00, but 16 Sqmm 4.0 core.
Description all as above Item No. 23.00, but 25 Sqmm 3.5 core.
Description all as above Item No. 23.00, but 35 Sqmm 3.5 core.
Description all as above Item No. 23.00, but 50 Sqmm 3.5 core.
Description all as above Item No. 23.00, but 70 Sqmm 3.5 core.
Description all as above Item No. 23.00, but 95 Sqmm 3.5 core.
Description all as above Item No. 23.00, but 120 Sqmm 3.5 core.
Supply and fix in repairs Aluminium lugs of size 16 sqmm
Supply and fix in repairs Aluminium lugs of size 25 sqmm
Supply and fix in repairs Aluminium lugs of size 35 sqmm
Supply and fix in repairs Aluminium lugs of size 50 sqmm
Supply and fix in repairs Aluminium lugs of size 70 sqmm
Supply and fix in repairs Aluminium lugs of size 95 sqmm
Supply and fix in repairs Aluminium lugs of size 120 sqmm
Supply and fix in repairs Aluminium lugs of size 185 sqmm
Supply and fix in repairs Aluminium lugs of size 240 sqmm
Supply and fix in replacement of MCCB 3 Pole, 415 V, fixed type, 25 to 100 Amps with breaking capacity 16 KA.
Description all as above Item No. 33.00, but capacity of 125 amps.
M & L in replacement for MCCB 3- pole, 415 volts, adjustable type 160 amps with breaking capacity 36 KA.
Description all as above Item No. 35.00, but 200 amps.
Description all as above Item No. 35.00, but 250 amps.
Description all as above Item No. 35.00, but 350 amps.
Description all as above Item No. 35.00, but 400 amps.
M & L for replacement MCCB 4 pole, 415 volts, adjustable type 250 amps with breaking capacity 36 KA
Description all as above Item No. 40.00, but 350 amps.
Description all as above Item No. 40.00, but 400 amps.
M & L for replacement pin type polymer, insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100 mm height, 65 mm dia for 1100 volts grade.
M & L for replacement shackle type polymer, vitreous, insulator including galvanised mild steel straps, washers, insulator bolts, washers and nuts, of height 75 mm and max dia 90 mm suitable for working pressure 1100 volts grade.
M & L for replacement disc insulator, polymer, 145 mm high and 255,, dia suitable for single disc asst for tension with tension clamps for conductors, working pressure 11000 volts grade.
Fixing in repairs of aluminium conductor steel re inforced, any sizes for replacement of broken over head line conductor of any type and length as required at site including removing of foreign objects/ obstacle, if any on the over head line, all as specified and directed ( New ACSR conductor used for replacement will be measured and paid under respective item)
Supply in repairs aluminium conductor steel re-inforced, any sizes as directed for use as replacements as line jumper or repairs of any brocken OH Line as material under the Item Ser No. 46.0 above complete.
Restringing of loose over head conductor/GI earth wire of any size and type after untyeing binding wire from insulators/cross arms to achieve permissible sag limit of over head line including new binding wire of proper size and pruning of tree branches of concerned spans and jointing of jumpers properly complete all as specified and directed at site. Note:- (i) One job consist one span of 3-phase, 4-wire over head line. (ii) The distance of one span is approx 30 to 50 meter.
M &L for repalcement straight through joint ( Epoxy joint) for following size PVC insulated and sheathed aluminium cable complete for following sizes :-
(a) 3.5 core, 50 sq mm
(b) 3.5 core , 70 sqmm
(c) 3.5 core , 95 sqmm
(d) 3.5 core , 120 sqmm to 150 sqmm
(e) 3.5 core , 185 sqmm
Material and labour in Painting and welding (both weldind and painting whenever required) of old exiting LT panel of any size with two coat of synthethic enemelled paint of approved colour internally and externally , after cleaning to rusted portion of panel and finishing the surfaces including one coat of primer by Skilled Painter complete all as specified and as directed. Note :-Repairs to LT panel boards complete incl. necessary welding works to door , replacement of unserviceable hings and all drop bolt , etc.
Supply and fix in repairs MCB TPN, 415V, 40 Amps, 'B' series complete incl all connections.
Supply and fix in repairs MCB TPN, 415V, 63 Amps, 'B' series complete incl all connections.
Supply and fix in repairs MCB SPN, 32 Amps, 240V, complete incl all connections.
Supply only MCB SP 6 to 32 Amps 230 Volt complete all as specified and as direcetd
M & L for Painting to street light pole of steel tubular swaged/ swan neck type with two coat of aluminium paint after cleaning to rusted portion of pole and finishing the surfaces including one coat primer top to bottom, painting on cross arms/FI clamps/street liht brackets of any type including making alternative blak and yellow strip with synthethic enemelled paint up to 1.5 Mtr height from ground level & writing of pole numbers with black paint on poles all as specified and directed.
M&L for painting of LT PCC poles 09 Mtr. with acrylic paint after apply two coat of cement base primer and making the surface smooth including painting of cross arms, clamps, etc with two coat of aluminium paint and providing alternative strip of 30 cm width (3 black and 2 yellow) from bottom of pole to 1.5 m height, writing of pole numbers in yellow circle 15 cm with black paint on poles complete all as specified and directed.
Supply and Errecting LT Bus Bar Panel outdoor type mounted and fixed with PCC foundation , made out of MS sheet factory assembled and factory fabricated out of 3.15 mm thick sheet steel with suitable size MS angle duly spray painted with two coat of gray synthetic enamel paint over one coat of red oxide zinc chrome primer after preparation of surface , with required civil work & wiring with copper cable of suitable size, connecting including indication lamp LED type for each phase , Aluminium bus bar - 400 Amps rating - 03 Nos. for phases and 400 Amp rating - 01 No. for neutral, incl inbuilt industrial type locking arrangments , front openable incl necessary arrangments for fixing with suitable, clamps,nuts, bolts wahers etc, & incl Danger notice board , feeder marked,testing and commissioning , size 600 x600x 300 mm, complete all as specified and directed
Supply and fixing cable path indicator made of MS sheet of size 200 mm x 150 mm x 3 mm thick and spot welding with angle iron of size 40 x 40 x 5 mm thick, 750 mm long embedded in PCC (1:2:4) type B-1( using 12.5 mm graded granite stone aggregate) including providing one coat of synthetic enamlled black paint over one coat of red oxide primer and sign writing with white paint showing size of cable HT /LT complete all as specified & directed .
Cutting the Existing bituminouse road for passing of UG Cable in road crossing and making good of disturbed surgace of road to match the existing all as specified and directed.
Supply and fixing in replacemnt moulding compound Street light junction box of size 250 mm x 200 mm x 105mm complete with shock and rust proof, termite resistant, tamper proof , front openable type and including suitable provision for single phase, two wire cable (size upto 25 Sqmm 2 Core) incomming & outgoing loop -in loop connection and including one no. MCB SP 6 Amp including non metallic clamps and GI nut bolts and washers of suitable size and fixed on pole / wall complete.
M&L in repair for Earthing Supply, installation¸ testing & commissioning of waterless and maintenance free earthing with earth (grounding) electrodes and PCC pit with cover. (a) Earth Electrode: 17.2 mm dia copper bonded MS rod shall be in-situ cast in electrically conductive concrete earth enhancing material mixed with cement. Size of embedding of electrically conductive concrete earth enhancing material shall be 85 mm dia. The electrode of 3000mm should be able to withstand a fault current upto 35kA (Peak) for 1 second duly tested from recognized National Test laboratories like CPRI, ERDA, ERTL, MSME etc (not more than 18 months old). The ratio of mixing of conductive concrete to cement should be 3:1. Other hardware like nut, bolts and washers should be of stainless steel. connected to earthing test point all as specified or indicated including testing on completion Note : Main earth lead beyond 7.5 meter shall be measured and paid saperatly.
M&L earthing complete with galvanised steel earth plate electrode of size 600 x 600 x 6 mm thick buried directly in ground in vertical position (earth pit not less than 2.25 m deep below the normal ground level) with top edge of the earth plate not less than 1.5 m below normal ground level, connected to galvanised earth strip of size 25 x 4 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel, all as shown in electrical plate no. 3 of SSR Part - 1, connected to earthing test point and complete all as specified and directed. Note:- The unit rate shall also include for earth work in any type of soil, PCC 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate) earth chamber, RCC 1:1.5:3, type A-1 cover slab, 40 mm thick reinforced with 6 mm dia TMT bar @ 150 mm C/C both ways, 10 mm dia plain bar lifting handle embedded in cover slab, 20 mm bore medium grade GI watering pipe, 40 mm bore GI light grade earth lead protection pipe, funnel, wire mesh, copper lugs, charcoal and common salt in alternate layer etc. (b) GI earth strip and GI protection pipe upto 7.5 mtr from under pole is deemed to be included in quated rates.
Supply only fibre glass discharge rod 20 ft long in three section made from best quality suitable for 11 KV/33 KV working pressure including all accessories all as specified and directed.
Supply only electrical rubber hand gloves suitable on working pressure of 11 KV all as specified and directed.
Supply only electrical rubber hand gloves suitable on working pressure of 33 KV all as specified and directed.
Supply and Fix in replacement of Transformer C&R panel Protection Relay of BCF1/REF615 Model REF615 is a dedicated feeder protection and control relay for protection, control, measurement and supervision of overhead lines and cable feeders in utility and power distribution systems, including radial, looped and meshed distribution networks all as specified and directed.
Ms Kailash Chandra Babulal (BID ID -3329873)
AGARWAL BUILDERS (BID ID -3334379)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .