| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.5 LAccepted-AOC 60 310A 3 KHERIA MOD JAGNER ROAD AGRA 01 | AGRA | UTTAR PRADESH | 282001 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹38.3 L+₹1.4 L (3.80%)Rejected-Finance 25 SHIV SAROVER COLONY GARH ROAD MEERUT 250002 | MEERUT | UTTAR PRADESH | 250002 | L2 | Rejected-Finance Found in order but L2 |
| Sl No | Description | Qty | Unit | A.V. ASSOCIATES L2 | rohan traders L1 |
|---|---|---|---|---|---|
| 1.00 | Demolition of brick work or stone/boulder masonary built in cement mortar incl all quoins arches pillars etc.complete all as specified & directed. | 8 | Cum | 500 ₹4,000 | 200 ₹1,600 Lowest |
| 2.00 | M&L brick work with sub class fly ash bricks straight or curved on plan exc 6 m mean radis built in CM 1:6 complete all as specified & directed. | 6 | Cum | 5,500 ₹33,000 | 5,000 ₹30,000 Lowest |
| 3.00 | M&L brickwork with subclass `B' bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 except bricks complete all as specified & directed. Note :- Old bricks retrived from demolition shall be re-used under this item. | 2 | Cum | 2,500 ₹5,000 | 1,500 ₹3,000 Lowest |
| 4.00 | Dismantling, floor, hearth or wall tiling including cement mortar bedding but not backing and removing rubbish off the premises complete all as specified & directed. | 458.54 | Sqm | 50 ₹22,927 | 10 ₹4,585.4 Lowest |
| 5.00 | M&L Non skid ceramic coloured tiles 7-8mm thick (Square/rectangular) area of each tile exceeding 0.11Sqm but not exceeding 0.18 Sqm in floors set and jointed in neat cement slurry and pointed with white or colour cemnt to match including 15 mm th screed ded in cm 1:6 complete all as specified & directed. | 76.3 | Sqm | 700 ₹53,410 Lowest | 700 ₹53,410 Lowest |
| 6.00 | M&L for PCC 1:2:4 type B-1 (using 20mm graded stone agg) 25 mm thick for Sub base flooring complete all as specified & directed. | 248.3 | Sqm | 145 ₹36,003.5 | 100 ₹24,830 Lowest |
| 7.00 | S&F Vitrified Ceramic tiles 8 to 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.18 Sqm but not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement over 15mm screed bed in CM 1:6 complete all as specified and directed. | 202 | Sqm | 700 ₹1,41,400 Lowest | 1,000 ₹2,02,000 |
| 8.00 | S&F Vitrified Ceramic tiles 8 to 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.18 Sqm but not exceeding 0.36 sqm, in skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement over 10mm thick rendering in CM 1:4 complete all as specified and directed. | 24.24 | Sqm | 650 ₹15,756 Lowest | 1,050 ₹25,452 |
| 9.00 | S&F Coloured Glazed colour ceramic tiles in vertical surfaces 450x300x7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match over 10mm thick plaster in CM(1:4) joint free with grout of matching shade complete all as specified & directed. | 156 | Sqm | 600 ₹93,600 Lowest | 700 ₹1,09,200 |
| 10.00 | Demolition of Stone slabs and tiles of any description or thickness in floors, aprons laid and pointed in any mortor etc. complete all as specified & directed. | 4.5 | Ten Sqm | 500 ₹2,250 | 100 ₹450 Lowest |
Tender Value
₹38.9 L
EMD Value
₹77,800
Closing Date
23 Oct 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
HQ CWE MEERUT
29J The Mall Road Meerut Cantt Uttar Pradesh 250001
ADDN/ALTN TO BLDG NO P-62 OFFR MD ACCN AT SN PARK UNDER GE (NORTH) MEERUT CANTT
2025_MES_732426_1
94269/MRT/2025-26/E8
Open Tender
Civil Works
Item Rate
180 days
MEERUT CANTT
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE (NORTH) MEERUT
₹77,800
Yes
4 Dec 2025
24 Sept 2025
28 Oct 2025
24 Sept 2025
23 Oct 2025
9 Oct 2025
Demolition of brick work or stone/boulder masonary built in cement mortar incl all quoins arches pillars etc.complete all as specified & directed.
M&L brick work with sub class fly ash bricks straight or curved on plan exc 6 m mean radis built in CM 1:6 complete all as specified & directed.
Dismantling, floor, hearth or wall tiling including cement mortar bedding but not backing and removing rubbish off the premises complete all as specified & directed.
S&F Vitrified Ceramic tiles 8 to 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.18 Sqm but not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement over 15mm screed bed in CM 1:6 complete all as specified and directed.
S&F Vitrified Ceramic tiles 8 to 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.18 Sqm but not exceeding 0.36 sqm, in skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement over 10mm thick rendering in CM 1:4 complete all as specified and directed.
M&L Non skid ceramic coloured tiles 7-8mm thick (Square/rectangular) area of each tile exceeding 0.11Sqm but not exceeding 0.18 Sqm in floors set and jointed in neat cement slurry and pointed with white or colour cemnt to match including 15 mm th screed ded in cm 1:6 complete all as specified & directed.
M&L for PCC 1:2:4 type B-1 (using 20mm graded stone agg) 25 mm thick for Sub base flooring complete all as specified & directed.
M&L machine cut prepolished kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with gray cement slurry mixed with pigment to match the shade of slab including rubbing and polishing upto Granite finish complete factory made bull nosed as in riser of steps, skirting/dadolaid over 10mm thick in cm 1:4 complete all as specified & directed.
S & F for 30mm thick Factory made single extruded WPC (Wood Polymer Composite) solid Moulded WPC door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N edge),minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge.(Note: stainless steel butt hinges and necessary S S screws shall be paid separately)
S & F for Factory made double extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/Chowkhat of size 65x125 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof,water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (Rates inclusive of M.S. hold fast/ lugs or SS dash fasteners). ® Note: For WPC solid door/window frames,minus 5mm tolerance in dimension i.e.depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be madecomplete all as specified & directed.
S&F for 30 mm thick second class hardwood factory made Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part-I, Section 8, clause 8.24 (b); supplied and fitted to chowkats complete all as specified and directed.
S&F for factory made gauzed shutter made out of U shape iron 35 mmx 35 mmx 5 mm and 25 mmx 25 mmx 5 mm and 1.5 mm thick, 10 mm square bars grill with stainless steel fly proof wire mesh having stainless steel 0.5mm nominal dia wire and 1.20mm average width of aperture including two coats of synthetic enamel paint over a coat of red oxide primer complete all as specfied and directed.
Supply and fixing factory made three track three shutter sliding window with frame incl stainless steel fly proof wire mesh having 0.56mm nominal dia of wire and average width of aperture 1.18mm & 5.5 mm thick glass (As approved by GE) panes fixed (Two nos. glazed & one no. wire mesh panels) made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 (+) (-) 0.2 mm and single glazing bead/ double glazing bead of appropriate dimension uPVC white colour sliding glazed window comprising uPVC multi chambered frame with inbuilt roller track and sash extruded profiles duly reinforced with 1.60 (+) (-) 0.2 mm thick alvanized mild steel section made from roll forming porcess of required length (shape & size according to uPVC profile) including appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing grame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. Rate inclusive of (Single/ double glass panes, wire mesh and silicon sealent and shall not be paid separately) Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.
Supply and fixing factory made ventilator with frame incl stainless steel fly proof wire mesh having 0.56 mm nominal dia of wire and average width of aperture 1.18 mm & 5.5 mm thick glass (As approved by GE) panes fixed (partially glazed & partially wire mesh) made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 (+) (-) 0.2 mm and single glazing bead/ double glazing bead of appropriate dimension uPVC white colour sliding glazed ventilator comprising uPVC multi chambered frame with inbuilt roller track and sash extruded profiles duly reinforced with 1.60 (+) (-) 0.2 mm thick galvanized mild steel section made from roll forming porcess of required length (shape & size according to uPVC profile) including appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. Rate inclusive of (Single/ double glass panes, wire mesh and silicon sealent and shall not be paid separately) Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.
S & F for 30 mm thick Flush shutters, solid core construction, with block board core and plywood face panels,commercial type on both sides face is covered with decorative sunmica with lipping/frame to match complete all as specified & directed.
M&L for 18/19mm thick WPC Solid board, exterior grade, prelaminated one side with decorative choice laminations and other side balanceing white lamination, fixed with SS screws to WPC frame work in cup boards, and kitchen cabinet rebated complete all as specified and directed.
M& L for 75mm long Brass handles, cast type, polished bright fixed with ss screw complete all as specified & directed.
M&L for making joint to existing CI/DI line incld making hole of desired size if required along with reducer and other accessories etc complete all as specified & directed.
S&F aluminium sliding bolt 300 long bolt type with bright bolt not less than 12 mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate complete all as specified & directed.
M&L for 15mm thick rendering in cement mortar 1:6 on fair faces of brick work or concrete surfaces finished even and fair complete all as specified and directed.
S&F aluminium anodised barrel tower bolt with bright bolt 200 mm long. complete all as specified & directed.
Taking down of cement plaster of any description from brick or stone wall etc. including raking out of joints, hacking for key, scrubbing down with water etc. complete all as specified & directed.
Preparation of old surface of existing treatment by mechanical means complete all as specified and directed
M&L for applying 2.00mm thick wall care putty making smooth surface complete all as specified and directed.
M&L Rendering 5 mm thick on fair faces of brick work or concrete surfaces, finished even and smooth on ceiling in cement mortar (1:3), complete all as specified & directed.
M&L for preparation of old/new decorated/undecorated surface of exterior/Interior wall/Ceiling of projection/chajja by complete removing existing treatment with mechanical sander (rpm 1500-2700) along with internal dust extraction system for clean environment certified by reputed paint manufacturers and including cutting/ uprooting trees/ wild grass complete then washing the surface with Bleaching powder solution for treatment of fungal and applying 1 mm thick white cement base wall care putty to obtain smooth finishes complete all as specified and as directed at site by Engineer-in-Charge & incl applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces of wall/ceiling of projection/chajja. , of approved make all as specified and prescribed by manufacture of paint and as directed at site by Engineer-in-Charge. Note:- (i) The work must be got executed through authorised applicator of manufacture after concluding an MoU with manufacture for company back guarantee for a minimum period of 04 years by the contractor. The authorised applicator of manufacture shall be got approved from GE before commencement of work. (ii) All the material to be incorporated on the work shall be brought by contractor to MES store yard which will be subsequently issued by deportment for incorporation in the work to ensure the quantity to be consumed all
M & L for applying ready mix plaster 15 mm thick rendering CM 1:4 on brick / concrete surfaces of external walls finished even and fiar, using water proofing compound @ 3% by weight of cement or as per manufacturer instructions, complete all as specified and directed : Note:- Water proofing compound shall be measured and paid sepratly
M&L for Two coat of OBD using spray machine for painting complete over one coat of primer complete all as specified & directed.
M& L preparing plastered un plastered old surfaces on ceiling and applying two coats of white wash on ceiling surface complete all as specified & directed.
M& L preparing plastered un plastered new surfaces on ceiling and applying three coats of white wash on ceiling surface complete all as specified & directed.
Demolition of reinforced concrete of any description and any poisition not otherwise specifically provide ( reinforcement cut to faciliatate demolition) complete all as specified & directed.
as per recommendation of manufacture. (iii) After carrying out preparation of surface the same shall be got approved from GE before application of primer and paint for each building. (iv) The colour/shade will be all as approved by GE. (v) The cost of scaffolding wherever required are deemed to be included in the rates quoted by the contractor complete all as specified and directed. The work shall be executed at a height from ground floor up to 15m (max). (vi) The old surface must be prepared in a manner so that there should not be any impression of dent and it should be made even all as per manufacture instruction to the satisfaction of Engineer-in-Charge before application of exterior paint. The cost of materials, labour & T&P required for preparation of surface are deemed to be included in the rates quoted. (vii) The application of acrylic paint/ weather coat shall be with fully automatic airless spray machine with a flow speed of min 1 litre per minutes having pressure of 3300 PSI by allowing 6 to 8 hrs to dry the surface before painting of subsequent coat. However, where it is not possible to apply acrylic paint by using the spray machine the work will be carried out manually by using roller.
M&L brickwork with subclass `B' bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 except bricks complete all as specified & directed. Note :- Old bricks retrived from demolition shall be re-used under this item.
M&L Form work to sides and soffits of beams lintels etc finished rough complete all as specified & directed.
Taking up or down steel tubing and connection 15 mm bore pipe and removing from site complete all as specified & directed.
S&F (in repair)chromium plated towel rail 20mm dia D type 600 mm long as a approved quality.complete all as specified and directed.
Supply & fix PVC connections of 450mm long suitable for 15mm dia iron pipe including PTMT nuts complete all as specified & directed.
M&L for dubbing out average 20mm thick on irregular faces of walls and ceilings CM 1:4 complete all as specified & directed.
S&F in Floor 140mm over all length with flap door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified & directed.
S&F in repair Gun metal globe or gate valves with Iron wheel head screwed both ends for iron pipe 20 mm dia complete all as specified & directed.
S&F in repair Gun metal globe or gate valves with Iron wheel head screwed both ends for iron pipe 25 mm dia complete all as specified & directed.
Supply & fix in repair 50 mm wide rubber beading for doors of required size complete all as specified & directed.
Material and labour for Water proofing treatment to sunken floors of kitchen, toilets, laboratories, bath anc WC's etc shall be as under :- (a) Application of Two component Acrylic modified cementitious coating (i) The surfaces to be applied shall be completely dry and free from containments such as dirt, dust, oil, surface treatments and old coatings. Concrete substrates must be mechanically prepared using abrasive blast cleaning or milling to remove cement laitance, existing coatings and achieve a gripping profile that is clean, dry and free from laitance and any other form of surface contamination. The installation instructions in manufacturer's published literature should be strictly complied with, including but not limited to the following (ii) Chipping out any visible cracks in "V-Groove" pattern as applicable. Special attention on this part. Cleaning of cracks & then filling those cracks with SIKA latex SBR 100 putty/ Dr Fixit 302 SBR latex / Perma latex SBR / FOSROC Nitabond SBR latex / Asian Paints latex as required. Final cleaning of surface with power grinder, wire brush, hair brush & vacuum pressure if required. (iii) Dampen all surfaces immediately ahead of application of Acrylic modified Cementitious coating of Sika Top Seal - 107 / Brush Bond FOSROC/ Dr Fixit/ STP/CICO. (iv) Whilst the surface is still damp from saturation (S.S.D), apply one coat of Acrylic modified Cementitious coating of Sika Top Seal - 107 / Brush Bond FOSROC/ Dr Fixit/ STP/CICO of viscosity as per manufacturer's instructions. |(v) Apply Glass Fabric Sheet of Sika Fab 1 / FOSROC/ Dr Fixit/ STP whilst the first coat is wet. (vi) Once touch dry, apply second coat of Acrylic modified Cementitious coating of Sika Top Seal - 107 / Brush Bond FOSROC/ Dr Fixit/ STP/CICO of viscosity as per manufacturer's instructions on the entire area. (vii) Second coat shall be applied after 6-8 Hrs of application of previous coat and in the direction right angle to the previous coat. (viii) Material & labour for suitable thickness of PCC 1:5:10 type E-2 (using 40mm graded broken brick aggregate) for filling in the sunken portion of slab up to its floor level.(g) Supply & fix of 32mm dia GI pipe medium grade, 450mm long (for draining out the water) complete all as specified and directed.
M & L for cutting of bushes small trees (Peepal small plants etc) trunks shrubs of any dia and girth from roof projection, chajjas , wall junction parapet etc at any height by necessary demoliton of brick work etc if requried and making good distrubed surfaces to match with existing finihes with and incl material and labore in CM 1:4 mixed with WPC /PCC 1:3:6 type B0 /Bk work in CM 1:4 as required at site and as directed by Engr-in-Charge
S & F in repair Harrison rails, mild steel, chromium plated with fixing brackets, stops, rollers etc.complete all as specified & directed.
Supply and fix in repais 110mm bore PVC (SWR) Pipes single socketed in any length with rubber ring joints, fixed to walls and floor etc. as in waste and rain water pipes complete all as specified & directed.
S&F stainless steel plate rack of size 750 x 600 mm incl. shelves , rod to put plates etc made out of 0.80mm thick stainless steel sheet after taking down old one complete all as specified & directed.
Taking down old existing water proofing treatment from the top of RCC/ arch slab, including taking down existing PCC padding or plaster and hacking the top of RCC slab, cleaning with water and disposal of rubbish off the premises complete all as specified & directed.
Material & labour for cleaning of concrete or plastered surface of roof and applying priming coat using with bituminous primer @ 0.30Kg per Sqm followed evenly by a tack coat @ 1.20 Kg per Sqm using 85/25 grade industrial hot blown bitumen, over it laid with 3mm thick APP modified polymeric water proofing membrane minimum weight 3.6 kg per Sqm reinforced with non-woven polyester fabric (weight not less than 160gm per sqm) unrolled & bonded to substrate with side and end laps 75mm and 100mm as per manufactures instructions and applying over it of tack coat using 85/25 grade industrial hot blown bitumen @ 1.20Kg per Sqm and finally finish the top by providing 40mm thick brick tiles kiln burnt, laid over & including 15mm thick screed bed in cement mortar 1:6, joints of the tiles grouted and flush pointed with cement sand mortar 1:3 mixed with 5% crude oil by weight of cement, complete all as specified and directed. (Note:- Dismantling of existing water tank on roof disconnected and after cleaning same position re-connecting shall be deemed included in quoted rat
e of item).
M & L repair to overhang portion of chajja, facia, dropwall etc. for continuous work by providing PCC(1:2:4) Type B-0 and finished with CM(1:3) after taking down of damaged portion of RCC work by maintaining same level and finished the surface to match with the existing surface by providing same finish. (Height of work to be considered upto 7m from FFL of Ground Floor.) (Note : Wherever reinforcement is required to be provided will be paid separately under relevant item and contractor have to inform the department one day in advance after binding of reinforcement for measurement otherwise no payment will be considered on this account)
Material & Labour for PCC 1:2:4 type B-O(using 12.5 mm graded stone aggregates) complete all as specified & directed.
M & L for repairing existing RCC structure work by gunting to damaged edge bottom of beam , chajja, slab 40 to 60mm thick and part of RCC member in CM 1:3 & depositing material/ mortar with spray gun under a pressure of 20 to 30 N/CM2 including skefolding and welding wire mess 2 mm dia and size of wiremesh 50mm X 50 mm including cutting welding and placeing position as directed by Engr in-charge.
Supply only liquid water proofing compound complete all as specified & directed.
Material and labour for damproofing to wall with two component Acrylic polymer cementitious water proof elastomeric coating four grade mix to form uniform slurry and apply with paint brush as first coat then laying a layer of fibre glass mesh cloth as first coat is still green with overlap of joints of fibre mesh not less than 100 mm, then finally apply second layer mix by brush to entire surface of container covering 0.6 - 0.75 Sqm /Kg at 1 mm thickness in two coat depending on the level of substrate and curing it for minimum 3 days. Note: Quoted rate shall be deemed to be inclusive of materials all labours, tools and plants, scaffolding and working upto height 6 metre etc. Make :- Pidilite Industries Ltd/ Fosroc India Ltd/ IWL India Ltd, BASF/T-Guard ANTC of Make - Trermax, complete all as specified and directed.
Material & labour for cement concrete (1:4:8) type D-2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete and sub base of floor complete all as specified and directed.
Material & labour for 40mm thick cement concrete 1:2:4 type B-1 including mixed with hardener (as per manufactures instructions, using 20mm graded stone aggregate) as in flooring, surface finished even and smooth by using extra cement including demolition of old PCC complete all as specified and directed .
S & F GI tubing, medium grade, 50 mm bore ISI marked complete with all fittings, laid in trenches or laid under floors, fixed on walls with and providing clamps etc complete all as specified & directed,.
Surface excavation n.exc (not exceeding) 30cm deep and averaging 15cm deep and getting out in soft /loose soil complete all as specified & directed.
Supply and fix PVC (SWR) bends 75mm bore, any radius complete all as specified & directed.
S & F GI tubing, medium grade, 25 mm bore ISI marked complete with all fittings, laid in trenches or laid under floors, fixed on walls with and providing clamps etc complete all as specified & directed,.
Each Job
M & L concrete bed to drain pipes including packing under, and hunching against the sides of pipes after they are laid and tested in cement concrete 1:4:8 type D2 for 150 mm dia pipe work in foul position complete all as specified & directed.
-ditto- but one fan point control by one 1- way switch complete all as specified & directed.
-ditto- but exhaust fan point control by one 1- way switch complete all as specified & directed.
-ditto- but security light point control by one 1- way switch complete all as specified & directed.
-ditto- but bell point control by one 1- way switch complete all as specified & directed.
-ditto- but control by two 2- way switch for light or fan complete all as specified & directed.
-ditto- but one out let socket point 3pin 5 amps on independent board complete all as specified & directed.
-ditto- but on the same board with other switches complete all as specified & directed.
-ditto- but using 2.5 sqmm copper conductor with 2.5 sqmm earth wire for one 15 amps socket outlet on independent board complete all as specified & directed.
-ditto- but using 4 sqmm copper conductor with 4 sqmm earth wire for one 20 amps socket outlet on independent board complete all as specified & directed.
M&L for each additional light point with 1.5 sqmm copper conductor on the same switch circuit for staircase lighting and sequrity light complete all as specified & directed.
S&F Modular Switch, 1 module, 6A, AC, 240V, one way ISI Marked and complete all as specified & directed.
S&F Modular 2-way Switch, 1 module, 6A, AC, 240V, one way ISI Marked and complete all as specified & directed.
Removing excavated material n exc 50 m and depositing where directed at a level n exc 1.5 m above the starting point soil complete all as specified & directed.
Taking down carefully any type of battens or conduit point wiring with conduit (light, fan, socket or power) complete including fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, pendent light fittings, MCBs / isolators, fan regulators, tube light fittings etc removing material from site to match the existing complete all as directed by Engineer - in - Charge.
S&F Modular Socket, 2 module, 6A, 2/3 pin combined, AC, 240V, ISI Marked and complete all as specified & directed.
S&F Modular Socket, 2 module, 6A / 16A, 2/3 pin combined, AC, 240V, ISI Marked and complete all as specified & directed.
S&F 1 module modular blank plate complete all as specified and directed.
S&F Modular Bell Push, 1 module, 6A, AC, 240V, ISI Marked and as specified.
S&F Modular Switch, 1 module, 16A, AC, 240V, one way ISI Marked wirh indicator and complete all as specified & directed.
S&F 15 watt LED bulb 2 pin B22 base,100 Lumems per watt,PF≥0.9, voltage surge protection 4kV ,6500K/3000K cool white,operating voltage 100-240V complete all specified and directed.
Supply and fixing wall mounted LED tube light fitting 20 watt with polycarbonate housing with all accessories and fixing material complete all as specified and directed.
Supply and fixing Bell,AC , 230 volts ,Single pole complete all as specified & directed.
Supply & fixing lamp holder (Angular / Straight), insulated body, with back plate complete all as specified & directed.
Supply and fixing decorative LED tube light fitting 10 watt 2' wall mounted with extruded polycarbonate ,integrated lamp & driver with opal diffuser and decorative end plates complete with all accessories and fixing material complete all as specified and directed.
S&F pressure die-cast alluminium housing 12 Watt LED flush / surface/reccesd mounting down light luminaire powder coated finish in round or square shape with integral electronic driver THD<10% complete all as specified and directed..
Material and labour for sub main wiring with 06 Sqmm nominal cross sectional area, two single core, 1100 Volts grade, stranded, PVC insulated FR-LSH, unsheathed, copper conductor cable with and including continuous earth wire of size 06 Sqmm nominal cross sectional area, single core, PVC insulated FR-LSH, unsheathed,copper conductor cable drawing into and including rigid no
n metallic PVC concealed conduit of 25 mm dia, medium grade with all conduit accessories / fittings, brass screws, washers etc and connected to common earth dolly including all cutting / chases etc in wall, making good to walls etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing incl taking down old u/s submain wiring complete all as specified & directed.
Material and labour for sub main wiring with 10 Sqmm nominal cross sectional area, four single core, 1100 Volts grade, stranded, PVC insulated FR-LSH, unsheathed, copper conductor cable with and including continuous earth wire of size 10 Sqmm nominal cross sectional area, single core, PVC insulated FR-LSH, unsheathed,copper conductor cable drawing into and including rigid non metallic PVC concealed conduit of 25 mm dia, medium grade with all conduit accessories / fittings, brass screws, washers etc and connected to common earth dolly including all cutting / chases etc in wall, making good to walls etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing incl taking down old u/s submain wiring complete all as specified & directed.
Supply and fixing sheet metal enclosure double door, single pole and neutral, AC, 240 volts, 08 way, with 200 Amps rated copper bus bar and IP - 43 protection with metal double door and flush to wall including all cutting on wall and making good including two coats of white/colour washing/distempering etc to match the existing disturbed surfaces incl taking down old u/s DB's complete all as directed by Engineer - in -charge.
Supply and fixing sheet metal enclosure double door, tripple pole and neutral, AC, 240 volts, 04 way, with 200 Amps rated copper bus bar and IP - 43 protection with metal double door and flush to wall including all cutting on wall and making good including two coats of white/colour washing/distempering etc to match the existing disturbed surfaces incl taking down old u/s DB's complete all as directed by Engineer - in -charge.
Supply and fixing Vertical Loadline sheet metal enclosure double door, Triple pole and neutral (TP&N vertical loadline) AC, 415 volts, 04 way, with 200 Amps rated copper bus bar and IP - 43 & IK 09 protection, with the inbuilt provison for fixing of 1 No MCCB of XT1160 frame suitable upto 125 Amp and 12 Nos MCB'S inside of DB, with metal door and flush to wall including grouting and cutting in existing wall and making good disturbed surface with two coats of white / colour washing / distempering etc to match the existing one and taking down the old distribution board along with mcb,mccb complete all as directed by Engineer - in - Charge. Note:- MCB's,MCCB will be measured and paid separately as required.
supply and fix wall fancy light fixture made up of polycarbonate including 8 to 10 watt LED lamp complete all as specified & directed.
Supply and fixing 35W LED building security light energy saving & environmental friendly long life luminaire with high power LEDs as light source and electronic driver including all material required for fitting complete all as specified & directed.
Material & labour for earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level steel earth plate connected with GI wire 04mm dia by means of lug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15mm bore light grade all as shown in elect plate No.3 of SSR part I connecting to main switch board / Main DB’s including excavation, earth work, salt and charcoal dust mixed and packed 150mm thick around GI earth plate, GI pipe medium grade 20mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover in PCC 1:2:4 type B1 duly reinforced with MS Bars 6mm dia at the rate of 150mm center to center both way with suitable lifting handle and pit / chamber in PCC 1:3:6 type C1 , Angle iron 40x40x5mm frame for pit cover including testing on completion complete all as specified and directed.
Supply and fixing MCB, SP, AC, 240 volts "C" series capacity of 06 to 32Amps, 10kA and making connections complete all as specified & directed.
Supply & fixing of ceiling rose, 2 phase/PVC/polycarbonate isolated body complete all as spe
cified & directed.
S&F MCB SPN 40 A, AC, 240V, 10KA, ISI Marked 'C' curve incl thimble etc complete all as specified and directed.
Supply and fix MCB 4P 63Amps,10KA C curve complete all as specified & directed.
Supply and fix MCCB 100A, 4P 415V fixed type 16KA breaking capacity complete all as specified & directed.
S&F Isolator TPN, 63A, AC, 415V, ISI/CE Marked complete all as specified and directed.
S&F in repairs 1 module SPN metallic enclosure with a two pin and earth plug and socket with one MCB SP 20 Amps complete all as specified and directed.
supply and fixing Exhaust fan with louver PVC and fixing accessories 230 Volt and 200 mm sweep mounted on aluminium frame complete all as specified & directed.
Supply and fix PVC (SWR) bends 110 mm bore, any radius complete all as specified & directed.
Excavation in trenches not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr in depth and getting out including foming of bottom surface for laying of cable / pipe etc in soft/loose soil.
Supply and fix electric water heater, storage type glassline coated inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection pipes,hanging assembly etc connecting with 3 core flexible Cu conductor cable of appropriate size from power point to the geyser including plug top,writing MES No. ,complete all as specified and directed.
Taking down existing ceiling fan of any size, CeiIing cable end,dismentalling blades ,make one set of three blades and keep them safe to deposited to E/M yard complete all as specified & directed.
Material and Labour for 10mm thick cement paster in CM 1:4 mixed with WPC @200 ml by weight of 50 kg cement bag finised even and smooth without using extra cement on roof surface when concreate is green and wall complete all as specified & directed. Note :- WPC will be measured and paid seperately as supply only rate.
Supplying & laying burnt clay fly ash old size bricks, straight or curved on plan, laid flat with width equal to length of brick, laid dry over under ground cable for protection complete all as specified and directed.
Taking down existing geyser of any size,keep them safe to deposited to E/M yard complete all as specified & directed.
S&F BLDC ceiling fan 1200mm sweep with remote, 220CMM air delivery,BEE 5 star energy rated minimum service value≥6,copper winded motor ,anti rust powder coated aluminium blade,double ball bearing, dynamically balanced including canopy,down rod,shackel assembly,safety pin,nut bolt etc electrical connection with flexible Cu conductor cable of appropriate size from ceiling rose/junction box to the fixture complete incl writing MES No. all as specified and directed by the engineer-in-charge.
Supply and fix electric instant water heater, storage type glassline coated inner tank and heating element upto 3 KW, capacity 3 litre, complete with all accessories such as safety valve, thermostate, NRV, connection pipes,hanging assembly etc connecting with 3 core flexible Cu conductor cable of appropriate size from power point to the geyser including plug top,writing MES No. ,complete all as specified and directed.
Returning filling in including spreading levelling, watering and well ramming in layers not exceeding 25 cm complete all as specified & directed.
S & F modular type 1 module TV socket M/F connector including terminal box complete all as specified and directed.
S&F RG6 copper coaxial cable for TV including concealed 20 mm rigid non-metallic PVC conduit inclusive of boxes (junction/terminal) , all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc complete all as specified and directed. Make:- Polycab,Finolex,Havells
Removing surplus soil to a distance not exceeding 50 Mtr and depositing where directed at a level not exc 1.5M above the starting point complete all as specified & directed.
GI light grade tubing 40mm dia laid in trenches, road crossing , pasing through pipe or laid in wall/pole complete all as specified & directed.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.35 MB
TD1.pdf
Tender Documents • 0.41 MB
TD2.pdf
Tender Documents • 0.26 MB
TD3.pdf
Tender Documents • 0.24 MB
TD4.pdf
Tender Documents • 1.49 MB
BOQ_820065.xls
BOQ • 3.49 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .