Loading…
Loading…
Tender Value
Refer Docs
EMD Value
₹21.8 L
Closing Date
22 May 2026, 12:30 pmClosed
Yes (up to 3 members)
No
Two Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
90 days
Expenditure
Capital (Works)
Upgradation of Datacom equipment's (UTN devices) and network connectivity in connection with PRS/UTS Modernisation at Tier - 2, 3, & 4 locations of Izzatnagar, Lucknow, Varanasi Division and HQ Gorakhpur over N. E. Railway.
N-235-62TeleTender04-2026
N-235-62TeleTender04-2026
Open
Works - General
6 Months
Gorakhpur, Uttar Pradesh
₹0
₹21.8 L
22 May 2026
24 Apr 2026
8 May 2026
256 items across 4 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 3,66,39,630.3 | ||
| — | 13.00 | — | — | ||
| Supply of Pre-lubricated HDPE Telecom duct, 40 mm OD, 33 mm ID in Drum length of 500/ 1000 meter length as per RDSO specification No. RDSO/SPN/TC/45/2013 Rev. 2.0 Amdt.3 or latest or TEC GR No. G/CDS 08/02 NOV-2004 OR with latest amendments as available either from RDSO or TEC approved firms along with test report of manufacturer with and following accessories supplied a) End Plugs- 2no for each km b) Cable sealing plugs -2 no. for each km of duct (c ) Plastic couplers slip fit/push fit type - 2no for each km of duct d) collars, bends to be provided along with drum for each km of drum etc. . HDPE duct should be Bright yellow or Bright blue colour [As per Railway Board's letter No. 2006/Tele/TP/1(3359379) dt. 02.01.2026]. The item also includes supply of all the accessories of HDPE duct like end caps, collars, bends, couplers etc. (Inspection: RDSO/RITES) | — | — | — | 7,33,351.71 | |
| — | 25.00 | — | — | ||
| Supply of thermoshrink jointing kit (RTSF-4) as per RDSO Specification No.IRS:TC 77/ 2012 Rev. 3 or latest. Jointing kit must be procured from RDSO approved vendor along with OEM test & warranty certificate. (Inspection: Consignee) | — | — | — | 64,341.25 | |
| — | 25.00 | — | — | ||
| Installation of thermoshrink jointing kit (RTSF-4) as per RDSO specification IRS/TC/77/2012 Rev. 3 or latest and as per direction given by Engineer at site. Railway will supply only thermoshrink jointing kit. | — | — | — | 34,012.25 | |
| — | 100.00 | — | — | ||
| Supply of OFC Joint closure for 24 fibres as per RDSO specification no. RDSO/ SPN/ TC/ 68/ 2025 Revision 2.0 or latest. (Inspection: Consignee) | — | — | — | 2,48,217 | |
| — | 50.00 | — | — | ||
| Supply of LC to SC Single Mode Simplex/Duplex Fibre Optic Patch Cable 5m length. Make: 3M, Huber- Shuner, R&M, TE Connectivity/Raychem/D- Link or Superior. (Inspection: Consignee) | — | — | — | 8,550 | |
| — | 50.00 | — | — | ||
| Supply of SC to SC Single Mode Simplex/Duplex Fibre Optic Patch Cable 5m length. Make: 3M, Huber- Shuner, R&M, TE Connectivity/Raychem/D- Link or Superior. (Inspection: Consignee) | — | — | — | 8,450 | |
| — | 20.00 | — | — | ||
| Supply of 2 MBPS E1 to Ethernet Convertor can operate on 230 VAC & 48 VDC as per Technical Specification in Annexure A attached. Make/ Brand: Techroute TD-CNV-ETH-E1/MROTEK/Cygnus/Team link/RAD/Anda Telecom/D-link. (Inspection: RITES) | — | — | — | 6,07,054.6 | |
| — | 200.00 | — | — | ||
| Supply of Single Mode Single Fiber Optical Media Driver 20KM, wavelength supported 1310 & 1550 nm, 10/100/1000 (Giga) RJ-45 with inbuilt power supply 230VAC/-48VDC as per Technical Specification in Annexure A attached. Make & Model: Tech routes TD-FMC-20KM/DIGISOL DG-MC6123S/DRON EDGE/Syrotech/D-Link/TP Link/Digisol or superior. (Inspection: RITES) | — | — | — | 8,47,776 | |
| — | 10.00 | — | — | ||
| Supply of Single fiber SFP L1-1 compatible to Tejas STM-1. (Inspection: Consignee). | — | — | — | 54,506.3 | |
| — | 10.00 | — | — | ||
| Supply of PSU (Power supply) Card suitable for PUNCOM. Make-Mux model V-Mux 100. (Inspection: Consignee). | — | — | — | 2,53,986 | |
| — | 10.00 | — | — | ||
| Supply of Loop Protection (LPC) Card suitable for PUNCOM Equipment Make: PUNCOM. (Inspection: Consignee). | — | — | — | 1,98,733.1 | |
| — | 10.00 | — | — | ||
| Supply of TME CARD FOR PRIMARY MUX MODEL NO. V-MUX 100 MAKE:- PUNCOM. (Inspection: Consignee). | — | — | — | 3,76,015.1 | |
| — | 10.00 | — | — | ||
| Supply of Power supply unit (PSU Card) for Webfil PD -MUX as per RDSO Spec -IRS-TC-68/12 or with latest amendment compatible with existing WEBFIL PD-MUX. Make-WEBFIL. (Inspection: Consignee). | — | — | — | 3,18,205.4 | |
| — | 10.00 | — | — | ||
| Supply of 2W/4W E&M VF Interface card (4 circuits/card) as per RDSO spec. no IRS-TC-68/2012 with latest amendment of Webfil make. (Inspection: Consignee). | — | — | — | 3,57,243.1 | |
| — | 10.00 | — | — | ||
| Supply of TRIBUTARY card as per RDSO Spec. no. IRS-TC 68/2012 with latest amendment of Webfil make. (Inspection: Consignee). | — | — | — | 5,08,001.4 | |
| — | 10.00 | — | — | ||
| Supply of NIM card as per RDSO Spec. no. IRS-TC 68/2012 with latest amendment of Make-Webfil. (Inspection: Consignee). | — | — | — | 3,41,774.5 | |
| — | 9000.00 | — | — | ||
| To Horizontal boring of dia. 120 mm under Railway Track/ Road/ Culvert etc. laying of cables at a minimum depth of 2 meter extending up to 2.5 meter from formation level as per drawing and directed by trenchless technology excluding the cost of DWC pipes. The bore should be capable enough for insertion of 120 mm dia DWC pipes (a) The Cost shall includes horizontal boring through any intermediate obstruction either natural of man made or any boundary strata. (b) The rate is inclusive of all materials, equipment's and labour required for doing trenchless horizontal boring under the railway track. To this extra shall be admissible on any account than the rates as per above. All necessary arrangements are to be provided and all precautions are to be taken so that bore coming out at other end is not deviated from the horizontal level line by more than 250 mm horizontal or vertical location. (d) The rates shall be inclusive of detection and protection of underground utilities encountered during boring. The bore shall be done at the depth of minimum 2000 mm from the ground level [As per Railway Board's letter No. 2006/ Tele/ TP /1 (3359379) dt. 02.01.2026]. The bore should be capable enough for insertion of 120 mm dia DWC pipes. | — | — | — | 32,34,960 | |
| — | 13.00 | — | — | ||
| Laying of HDPE duct (40/33mm) as per Technical Specification in Annexure A attached | — | — | — | 78,284.96 | |
| — | 50.00 | — | — | ||
| Splicing of fibre (Splicing machine and machine operator shall be given by contractor including all T & P items and labour required). | — | — | — | 2,33,144.5 | |
| — | 5000.00 | — | — | ||
| Excavation of cable trench of 110 cm depth and 30 cm wide in all kinds of soil with in station limit and block section for main cable as per direction of site engineer and its refilling with same excavated soft soil as per Technical Specification in Annexure A attached. | — | — | — | 1,54,400 | |
| — | 13.00 | — | — | ||
| Blowing/drawing of OFC cables in the HDPE duct along with all the protective work as per instructions of engineer incharge at site | — | — | — | 1,13,418.24 | |
| — | 13.00 | — | — | ||
| Laying of OFC/ PIJF cable/ Quad cables in trenches, in HDPE pipe etc. All protective works & meggering of all cables take provided by contractor as per Technical Specification in Annexure A attached. (All cables will be supplied by Railway) | — | — | — | 66,245.66 | |
| — | 25.00 | — | — | ||
| Supply and fixing of 20 PAIR CT BOX made of Cast Aluminium with in built locking system should double outlet with leading in brass nozzles and main tag block plate is mounted on the inner aluminium chamber with 40 brass terminals 3.8 mm thickness 2A type studded in the hylam sheet 4 mm thickness and superior quality. Make/Brand :RUDRA GLOBAL POWER or superior. (Inspection :Consignee) | — | — | — | 57,800.25 | |
| — | 6000.00 | — | — | ||
| Supply of Single mode 6 Fiber Armoured Optic Fibre Cable as per Technical Specification in Annexure A attached. Make: MOLEX, AMP, Schneider, Systemax, Panduit, D-Link,Finolex. (Inspection: RITES) | — | — | — | 1,57,680 | |
| — | 6100.00 | — | — | ||
| Supply of STP CAT-6 Cable (Shielded Twisted Pair) of 305 Mtr box compliant with latest EIA/TIA-568-B2-1 as per Technical Specification in Annexure A attached. Make: DLink/ DAX/ Lucent/ Crone/ Amp./ Sterlite/ Finolex/ Digilink/Dogisol. (Inspection: RITES) | — | — | — | 2,07,034 | |
| — | 500.00 | — | — | ||
| Supply & Installation of PVC conduit pipe (minimum 25 mm dia./1.55 mm thick, 3 metre long and ISI brand) with flexible pipes fixing /laying materials and all other accessories as per requirement. Make: D Plast, Polypack, Polycab or superior. (Inspection: Consignee) | — | — | — | 75,100 | |
| — | 50.00 | — | — | ||
| Supply & Installation of 2 x 6 Fiber (SC type) FMS having capacity to be included inside pole mounted rack as per Technical Specification in Annexure A attached. Make: Molex/ iball/D-Link/ Syrotech/ Commscope/ Digisol/PANDUIT/3M/Raychem/TYCO. (Inspection: Consignee | — | — | — | 1,54,422.5 | |
| — | 100.00 | — | — | ||
| Supply of STP/UTP RJ 45 Connectors. Make: D-Link/Digisol or superior. (Inspection: Consignee) | — | — | — | 389 | |
| — | 50.00 | — | — | ||
| Supply of UTP CAT 6 Patch Cord, 2 Meters long factory crimped with suitable connector at both ends. It Shall comply to TEC GR No. TEC/GR/SLC - 01/02.AUG 05 (TEC Standard Number: TEC 52010:2005) with latest amendments,Version. Make: Schneider, Systemax, Panduit, D-Link, Molex. (Inspection: Consignee) | — | — | — | 4,903.5 | |
| — | 4.00 | — | — | ||
| Trenching on pucca road/platform upto a depth of 1.20 Meter & 30 Cm. wide and refilling with soil including leveling of trenches and repairing to the original condition. The responsibility of obtaining permission from civil authorities, like -Municipality, PWD, Forest etc. rests with the tenderer (All the materials required for repairing of road / platform shall be supplied by the contractor. | — | — | — | 2,82,304.72 | |
| — | 2.00 | — | — | ||
| Supply, Installation, Testing & Commissioning of 10 KVA UPS including suitable Rack as per Technical Specification in Annexure A attached. Make:APC/ Uniline/ Microtek/ Amararaja /Luminous/Numeric/TATAlibert/Emerson. (Inspection: RITES) | — | — | — | 4,68,660 | |
| — | 35.00 | — | — | ||
| Supply of Maintenance Free Valve Regulated Lead Acid (SMF-VRLA) 12V/120AH Battery consisting of 6 Cells of 2V 120AH Battery as per RDSO Specification No. IRS:S-93/96 with Amendment-1 or latest. Make-EXIDE/ AMARRAJA/ AMRON/ HBL/ OKAYA or similar. (Inspection: RDSO) | — | — | — | 5,86,880 | |
| — | 2000.00 | — | — | ||
| Supply of power cable 3 core 2.5 sq mm multi strand (36/0.3 mm dia) cable as per IS 694:1990 reaffirmed 1995 or latest suitable for railway electrification area shall be of reputed make like Delton/LAPP/Finolex/Havells/Polycab/Mescab or superior. (Inspection: Consignee) | — | — | — | 67,960 | |
| — | 10.00 | — | — | ||
| Supply & Installation of Sealed Maintenance free VRLA Battery set of standard make similar to Exide / Amararaja, 2V per cell, 200 AH capacity in stack of 24 cells for giving a out put voltage of 48V complete with associated base plates interconnecting cables, connectors for the rows and cells with all accessories as per RDSO Specification No. IRS 93/96(A) Amdt.1 or latest with cuticle steel/hylem tray battery rack to install/house batteries. (Inspection: RDSO) | — | — | — | 10,23,660.8 | |
| — | 10.00 | — | — | ||
| Supply & Installation of SMPS based battery charger 48 Volt DC/25 Amp in N+1 Configuration module of 25 Amp (3 Nos) with ultimate expendable capicity 75 Amp with automatic switching between the module as per RDSO/SPN/TC/23/1999 Ver.4 Amnd.1 or latest. (Inspeciton: RDSO) | — | — | — | 10,57,596.1 | |
| — | 10.00 | — | — | ||
| Supply of managed expandable rack type STM-1 ADM as per Technical SPEC No -TEC GR No GR/ SDH-04/02 MARCH-02 with latest amendment with STM-1 aggregate interface 21 E1s and 4Nos of 10/100 BASE T Ethernet Port, Order Wire, Power Supply Unit sub rack, installation material and accessories, Manual and Software etc.. The Equipment should be fully wired for its ultimate capacity. It should be fully compatible with existing OFC system (Make- PUNCOM). (Inspection: RDSO) | — | — | — | 21,72,322.7 | |
| — | 10.00 | — | — | ||
| Supply of programmable Primary Digital Drop Insert MUX with conference facility fully wired for 30 channels complete with all accessories and power supply etc. asper IRS-TC-68-2004 or latest. The MUX shall be equipped for 16 E&M VF circuits, two 64KBPS circuits, 12 subscriber interface circuits (Make- PUNCOM / Webfill). (Inspection: RDSO) | — | — | — | 14,10,877.6 | |
| — | 10.00 | — | — | ||
| Installation, wiring, testing & commissioning of managed SDH (STM-1 Add/Drop MUX and upgradeable to STM-4) fully wired for 2 X 63 MB and equipped for 21E1s and a Virtual Container (VC)-12 with STM-1(L1.1) aggregate interface including power supply, order wire, Ethernet card, sub rack, inbuilt DDF, installation material and all other accessories, manuals etc. as per TEC. Specification GR SDH 04/02, March 02 or with latest amendment. The contractor will install all other accessories as mentioned in the above said TEC Specifications and system will have provision of different redundancy cards as per the TEC Specifications. Note: It shall be possible to increase capacity from 21E1 to 63E1s by adding / inserting tributary cards. This includes connecting all pig tails, optical patch cords etc. to the SDH equipment. This also includes connecting the SDH equipment with all cards to the 48V Bus including supply of wires and connectors. Termination of all E1s on DDF taking PVC cable over runway or a wall. At the terminal station, one port may be disabled if required as per instructions given by site engineer incharge. | — | — | — | 5,51,228.6 | |
| — | 20.00 | — | — | ||
| Supply, installation & fixing of FDMS as per RDSO Spec. No. RDSO/SPN/TC/37/2020 Revision 4.0 or latest suitable for terminating of 24/48 fibre OFC. Splicing of 24/48 fiber Optic Fibre Cable on the splice trays with provision of taking out 24/48 fiber of OFC. Pigtail with connector etc. 10 meter & 5 meter length as per Technical Specification in Annexure A attached and as advised by railway engineer as per requirement shall be supplied by contactor. This includes fixing of FDMS inside rack. Make: 3M/ Raychem/ TYCO (Inspection: RDSO/RITES) | — | — | — | 9,71,346.4 | |
| — | 32.00 | — | — | ||
| Supply, installation and Fixing of 19 inch rack of 17U size (HxWxD) 931mm x 600mm x 600mm with required accessories for mounting the equipment's as per Technical Specification in Annexure A attached. Make: APW President or Rittal or HCL or APW or Comrack or Valrack or Schneider or Dataracks or D-Link or superior. (Inspection: RITES) | — | — | — | 5,75,764.8 | |
| — | 9.00 | — | — | ||
| Supply of 4 Port LAN Extender 30MBPS Fast Ethernet on 4W/2Wconfigurable & it should support 230V AC/48V DC working with AC Power cord as per RDSO Specification No. RDSO/SPN/TC/82/2020 Rev. 2.0 or latest. Make: MROTEK/ TEAMENGINEERING/ Cygnus/ Team link/D-link or superior. (Inspection: Consignee) | — | — | — | 1,71,187.65 | |
| — | 10.00 | — | — | ||
| Supply and installation of 24 Ports Managed PoE+ Layer-2 Access Switch 24 10/100/1000 BASE-T PoE, 10G 4 SFP ports and RJ-45 console port with supply of 0 4 Nos. compatible 10G SFP as per Technical Specification in Annexure A attached. (Switch should be TTP approved and to be procured from TTP approved sources). Make: Cisco/Juniper/HP/Zyxel/Digisol or superior. (Inspection: RITES). | — | — | — | 5,32,191.2 | |
| — | 70.00 | — | — | ||
| Supply & Installation of layer-2 switch (minimum 8+2 manageable) with 08 Nos. 10/100/1000 Mbps ethernet port POE and 02 nos.1000 base X SM SFT port with optical modules complete with all accessories etc. as per clause 14.0 (III) of RDSO specification no. RDSO/ SPN/ TC/ 65/ 2021 Rev 6.0 Amendment No. 1, 2 & 3 or latest and as per Technical Specification in Annexure A attached. (Switch should be TTP approved and to be procured from TTP approved sources). Make: Cisco/Juniper/HP/Zyxel/Digisol or superior. (Inspection : RDSO) | — | — | — | 11,72,210.9 | |
| — | 140.00 | — | — | ||
| Supply of SFP Optical/Electrical 1 Gbps or 100/1000 Mbps Electrical as per Technical Specification in Annexure A attached and as per site requirement. Make: Syrotech/CISCO/ JUNIPER/ D-Link or superior. (Inspection: Consignee) | — | — | — | 4,22,690.8 | |
| — | 45.00 | — | — | ||
| Supply, Installation, Configuration, Testing and Commissioning of Tier-3/4 Router (04 WAN ports) with all associated accessories, power cable, console cable, manuals, mounting hardware etc. All other specification as per CRIS letter no. CRIS/HQ/NTWG/26/2023 CN dated 20.10.2023 & Railway Board's letter no. 2024/Tele/6(3)/1 dated 06.02.2026 . Detail Specification in Annexure A attached. This item should be compatible with Tier 1 Router which will be installed by CRIS. Make: CISCO/ Juniper/ Nivetti/ HP/Techroutes or superior. (Inspection : RITES). | — | — | — | 1,14,92,939.7 | |
| — | 12.00 | — | — | ||
| Supply, Installation, Configuration, Testing and Commissioning of Tier-2 Router (08 WAN ports) along with all associated accessories, power cable, console cable, manuals, mounting hardware etc. All other specification as per CRIS letter no. CRIS/HQ/NTWG/26/2023 CN dated 20.10.2023 & Railway Board's letter no. 2024/Tele/6(3)/1 dated 06.02.2026. Detail Specification in Annexure A attached.This item should be compatible with Tier 1 Router which will be installed by CRIS. Make: CISCO/ Juniper/ Nivetti/ HP/Techroutes or superior. (Inspection : RITES). | — | — | — | 30,81,332.16 | |
| — | 5.00 | — | — | ||
| Supply and installation of Maintenance and Administrative Console (in form of Laptop) for programming and maintenance of system as per Technical Specification in Annexure A attached. Make - HP/Dell/Lenovo/Acer. (Inspection: Consignee) | — | — | — | 3,96,475.85 | |
| — | 5.00 | — | — | ||
| Supply & Installation of NMS Maintenance Console (in form of Desktop) Intel Core i5 and MS Office with license pre installed with Standard Display 23 inch or higher & Onsite OEM warranty- Min. 3 Years as per Technical Specification in Annexure A attached. Make: HP ProOne 440 G9 AIO I5 13500 Win11P /DELL/LENOVO/ACER. (Inspection: RITES) | — | — | — | 3,50,000.05 | |
| — | 5.00 | — | — | ||
| — | 5.00 | — | — | ||
| Supply & Installation of NMS All in one InkJet Color printer (Multi- Function: Print, Scan & Copy) with Fax, Wi-Fi & Auto Duplex facility as per Technical Specification in Annexure A attached. Make/Model: CANON All in One Printer G4780/HP/Epson/Brother. Inspection: Consignee | — | — | — | 1,24,000 | |
| — | — | — | 4,27,07,430.57 | ||
| — | 12.00 | — | — | ||
| Supply & Installation/Testing of Terminal Server( TS), with 16 Terminal ports with 1500 V AC isolation on each terminal port, each unit supplied one AC power cord & one user manual as per Technical Specification in Annexure A attached. Make: Cygnus/team link or equivalent specification to Team Link-5088 16 Port. (Inspection: Consignee) | — | — | — | 3,65,300.04 | |
| — | 23180.00 | — | — | ||
| Supply of STP CAT-6 Cable (Shielded Twisted Pair) of 305 Mtr box compliant with latest EIA/TIA-568-B2-1 and as per Technical Specification in Annexure A attached. Make: DLink/ DAX/ Lucent/ Crone/ Amp./ Sterlite/ Finolex/ Digilink/Dogisol. (Inspection: RITES) | — | — | — | 7,86,729.2 | |
| — | 20.00 | — | — | ||
| Supply, Installation, Configuration, Testing and Commissioning of Tier-3/4 Router (04 WAN ports) with all associated accessories, power cable, console cable, manuals, mounting hardware etc. All other specification as per CRIS letter no. CRIS/HQ/NTWG/26/2023 CN dated 20.10.2023 & Railway Board's letter no. 2024/Tele/6(3)/1 dated 06.02.2026 . Detail Specification in Annexure A attached. This item should be compatible with Tier 1 Router which will be installed by CRIS. Make: CISCO/ Juniper/ Nivetti/ HP/Techroutes or superior. (Inspection : RITES). | — | — | — | 51,07,973.2 | |
| — | 24.00 | — | — | ||
| Supply, Installation, Configuration, Testing and Commissioning of Tier-2 Router (08 WAN ports) along with all associated accessories, power cable, console cable, manuals, mounting hardware etc. All other specification as per CRIS letter no. CRIS/HQ/NTWG/26/2023 CN dated 20.10.2023 & Railway Board's letter no. 2024/Tele/6(3)/1 dated 06.02.2026. Detail Specification in Annexure A attached.This item should be compatible with Tier 1 Router which will be installed by CRIS. Make: CISCO/ Juniper/ Nivetti/ HP/Techroutes or superior. (Inspection : RITES). | — | — | — | 61,62,664.32 | |
| — | 50.00 | — | — | ||
| Supply, Installation, Testing & Commisioning of Gigabit Ethernet Media Converter Single Mode Single Fiber, SM, Sc, 1310nm, Transmission Type: 10/100/1000M FDX/HDX, Wavelength: Single mode: 1310/1550nm up to 20Km, Power Supply:External 1A,+5VDC, Connector: UTP: RJ-45 connector,Optical: SC connector (Single Fiber), with all accessories like power adaptor. All installation material and suitable optical patch cord should be supplied by contractor. Make: DRON EDGE DE-SMBIDI-2025/Tech routes/Syrotech/D-Link/TP Link/Digisol or superior. (Inspection: Consignee) | — | — | — | 2,74,428 | |
| — | 50.00 | — | — | ||
| Network Cable Tester POE Wire Checker Launcher & Receiver UTP & STP Cable Continuity Tester for RJ45/CAT5/CAT6/CAT7 Cable. Make: FEDUS or superior. (Inspection: Consignee) | — | — | — | 84,960 | |
| — | 65.00 | — | — | ||
| Supply, Installation, Testing and Commissioning of 2 KVA on line UPS 120 Minutes backup with suitable battery stand as per Technical Specification in Annexure A attached. Make: APC/Numeric/Emerson/Uniline/Vertive/ Microtek/ Amararaja /Luminous//TATAlibert/V Gaurd/BPE. (Inspection: RITES) | — | — | — | 40,65,100 | |
| — | 590.00 | — | — | ||
| Supply of 10 m long OFC patch cord single mode simplex of different configuration SCAPC/ SC-FC/LC-LC/LC-FC/LC-SC/SC-SC/FC-FC etc. as per site requirement. Make: 3M, Huber- Shuner, R&M, TE Connectivity/Raychem/D-Link or Superior (Inspection Consignee). | — | — | — | 3,28,311.4 | |
| — | 44.00 | — | — | ||
| Supply, installation and Fixing of 19 inch equipment rack of 24U size and minimum depth of 650mm with cable tray for accomdating modems, power strips and fan for proper ventilation with required accessories for mounting the equipment's as per Technical Specification in Annexure A attached. Make: EPI or President or Netcell or Valrack or Rittal or Netrack or SVTel or Rackom or Schneider or D-Link or superior. (Inspection: RITES) | — | — | — | 11,24,469.72 | |
| — | 4400.00 | — | — | ||
| Supply and fixing of capping casing of size 25 mm X 10 mm X 0.3mm press fit on wall, as per site requirement all fixing materials will be supplied by the contractor. (Inspection: Consignee) | — | — | — | 92,268 | |
| — | 13200.00 | — | — | ||
| Supply of Power Cable 3 Core, 2.5 sq. mm, multi strand copper conductor, PVC insulated, armored, confirming to IS: 1554 Part-I or latest as per Technical Specification in Annexure A attached. Make: Delton/ LAPP/ Finolex/ Havells/ Polycab /Mescab or superior. (Inspection: RITES) | — | — | — | 12,51,756 | |
| — | 4500.00 | — | — | ||
| Laying and drawing of data/OFC / Power cable through PVC Pipe, Casing Capping & conduit Pipe as per Instruction of Engineer Incharge. | — | — | — | 1,23,705 | |
| — | 88.00 | — | — | ||
| Supply of Power Board (3 No's 5 Amp & 1 No. 15 Amp socket total -4 points). (Inspection: Consignee) | — | — | — | 49,724.4 | |
| — | 88.00 | — | — | ||
| Supply of C series MCB 2 POLE 32 AMP with metal enclosure. Make: Legrand (Model No.: 4086 36) or Havells or L&T or Anchor. (Inspection: Consignee) | — | — | — | 51,178.16 | |
| — | 5.00 | — | — | ||
| Supply and installation of Professional Large Format UHD Display unit, Size minimum 139 cm (55 inch). Non Touch screen duty cycle 24x7 as per Technical Specification in Annexure A attached. Make: LG 55UH7J-H/Samsung/Sony/Panasonic or superior. (Inspection: Consignee) | — | — | — | 3,87,475 | |
| — | 1.00 | — | — | ||
| Supply of Online UPS of Rating 5.0 KVA With Battery Of Backup Time 120 Minutes as per Technical Specification in Annexure A attached. Make: BPE- MFIL1105L200/APC/ Uniline/Vertive/ Microtek/ Amararaja /Luminous/Numeric/TATAlibert/Emerson or superior. (Inspection: Consignee) | — | — | — | 2,15,500 | |
| — | 53.00 | — | — | ||
| Supply, Installation, Testing & Commissioning of rack mountable 24 port manageable Layer-2 switch 24 x 10/100/1000 BASE-T PoE Ports and 4x1 G (minimum) SFP+ ports with supply of compatible 2 Nos of Single Mode 1G SFP Modules, minimum PoE Power Budget of 370W or better with all accessories as per RDSO spec. No:RDSO/SPN/TC/65/2021 Version 6.0 or latest. (Switch should be TTP approved and to be procured from TTP approved sources). All the accessories and fixing materials required for this installation are to be supplied by contractor within the same cost. Make: Cisco/Juniper/HP/Zyxel/Digisol or superior. (Inspection : RDSO) | — | — | — | 13,39,464.76 | |
| — | 22.00 | — | — | ||
| Supply. Installation and commissioning of CEL-1 Card consist 04 port 10/100 Mbps Ethernet port for TJ1400 model with associated accessories (Suitalbe for Tejas STM-TJ1400 ). (Inspection: RDSO) | — | — | — | 10,23,278.3 | |
| — | 22.00 | — | — | ||
| Supply of cross connect XA140T5 Card compatible with STM-4 TJ1400. Note- XA140T5 card should be compatible with existing STM-4.(Suitalbe for Tejas STM-TJ1400 ). (Inspection: RDSO) | — | — | — | 21,09,250 | |
| — | 22.00 | — | — | ||
| Supply of 63 E1 interface card Suitable for TJ1400 (Suitalbe for Tejas STM-TJ1400 ). (Inspection: RDSO) | — | — | — | 18,44,964.22 | |
| — | 22000.00 | — | — | ||
| Supply of Single mode 6 Fiber Armoured Optic Fibre Cable as per Technical Specification in Annexure A attached. Make: MOLEX, AMP, Schneider, Systemax, Panduit, D-Link,Finolex. (Inspection: RITES) | — | — | — | 5,78,160 | |
| — | 4700.00 | — | — | ||
| Supply of Pre-lubricated HDPE Telecom duct, 40 mm OD, 33 mm ID in Drum length of 500/ 1000 meter length as per RDSO specification No. RDSO/SPN/TC/45/2013 Rev. 2.0 Amdt.3 or latest or TEC GR No. G/CDS 08/02 NOV-2004 OR with latest amendments as available either from RDSO or TEC approved firms along with test report of manufacturer wiitth and following accessories supplied a) End Plugs- 2no for each km b) Cable sealing plugs -2 no. for each km of duct (c ) Plastic couplers slip fit/push fit type - 2no for each km of duct d) collars, bends to be provided along with drum for each km of drum etc. . HDPE duct should be Bright yellow or Bright blue colour [As per Railway Board's letter No. 2006/Tele/TP/1(3359379) dt. 02.01.2026]. The item also includes supply of all the accessories of HDPE duct like end caps, collars, bends, couplers etc.. Inspection: RDSO/RITES | — | — | — | 2,65,127 | |
| — | 4500.00 | — | — | ||
| Blowing/drawing of OFC cables in the HDPE duct along with all the protective work as per instructions of engineer incharge at site. | — | — | — | 39,240 | |
| — | 88.00 | — | — | ||
| Supply of 12 port loaded LIU rack mountable as per Technical Specification in Annexure A attached. Make: Molex/ iball/D-Link/ Syrotech/ Commscope/ Digisol/PANDUIT/3M/Raychem/TYCO. (Inspection: Consignee) | — | — | — | 3,17,468.8 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
TD_UTN_NER.pdf
ATTACHMENT
ACS1to11_compressed.pdf
ATTACHMENT
TechnicalSpecificationAnnexure-A.pdf
ATTACHMENT
CirculationofTheTelecommunicationsFrameworktoNotifyStandardsConformityAssessmentandCertificationRules2025_ComplianceRequirements3.pdf
ATTACHMENT
CRIS-TechnicalSpecificationofRouters.pdf
ATTACHMENT
GCC_April-2022_2022_CE-I_CT_GCC-2022_POLICY_27_04_22.pdf
ATTACHMENT
JPOforearthworkdiggingwork-NER.pdf
ATTACHMENT
MII_Revision_Order_19July20241.pdf
ATTACHMENT
MTCTEandITSARCertificationfortelecomnetworking.pdf
ATTACHMENT
PreferencetoMakeinIndiaOrder2017.pdf
ATTACHMENT
systemimprovementregardingelaboratingtheissuesofcompatibilityperformanceofthetelecomequipments.pdf
ATTACHMENT
Tele_Cir_12-2023UseofTrustedProductsfromTrustedSourcesforbackbonetelecom.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .