Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹8.0 LAccepted-Finance NULL | 1 | Accepted-Finance L1 | |
| 2 | 2₹8.7 L+₹72,244.51 (9.03%)Rejected-Finance UC I USHA PARK HARI NAGAR NEW DELHI 64 | NEW DELHI | DELHI | 110001 | 2 | Rejected-Finance L2 | |
| 3 | 3₹8.8 L+₹81,737.87 (10.2%)Rejected-Finance | 3 | Rejected-Finance L3 | |
| 4 | Rejected-Technical 1 3104 KUNJ GALI RAM NAGAR EXTN LONI ROAD SHAHDARA DELHI 32 | SHAHDARA | DELHI | 110032 | - | Rejected-Technical Affidavit is not in order |
Tender Value
₹9.5 L
EMD Value
₹19,000
Closing Date
20 Mar 2026, 3:00 pmClosed
Executive Engineer (Elect)/KBZ
OFFICE OF THE EX. ENGINEER (ELECT)-IV/KBZ TOURIST CAMP SITE, J.L. NEHRU MARG, DELHI-02
Rewiring in MC Primary School, 28 Block, West Patel Nagar in Ward No 86 under Karol Bagh Zone
2026_MCD_271062_4
NIT No 52/EEE/KBZ/MCD/2025-26
Open Tender
Electrical Works
Percentage
90 days
Karol Bagh Zone
Please refer Tender documents.
5 documents required · 5 mandatory
₹590
₹19,000
7 Apr 2026
14 Mar 2026
20 Mar 2026
14 Mar 2026
20 Mar 2026
14 Mar 2026
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required Group C
Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. (a) 5/6 amp switch
(b) 3 pin 5/6 amp Socket Outlet
(c) 15/16 amp switch
(d) 6 pin 15/16 amp socket outlet
(e) Bell Push
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. (a) 25 mm
Wiring for curcuit/ submain wiring alongwith earth wire with the following size FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as reqd. 2X2.5 mm+1X2.5 mm earth wire.
Wiring for curcuit/ submain wiring alongwith earth wire with the following size FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as reqd. 2X6 mm+1X6 mm earth wire.
Supplying and fixing following rating, four pole, (three phase and neutral), 415 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63A
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way, Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C"curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C"curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole with Neutral
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63A
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and laying earth connection from earth electrode with 6SWG dia GI wire in 15mm dia GI pipe with earth electrode as required.
S&L 25mmX5mm GI strip at 0.5 metre below ground as strip earth electrode,including connection/terminating with GI nut,bolts,spring, washer etc as reqd. (Jointing shall be done by overlapping and with 2 sets of GI nut bolt & spring washer spaced at 50mm)
SITC of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal ( Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9,Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS :374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as req 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
SITC of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range 15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/ 6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineerin-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). LED Batten light (System lumen efficacy >135 lm/Watt) 18- 22 watt
P/F 4.5 kg Co2 type fire extinguisher sqeeze type, trolly wheel as well mounting type complete in all respect with isi mark i/c fixing arrangement etc. as reqd.
P/F ABC (Aluminium Phosphate) Power type fire extinguisher of 6 kgs capacity complete in all respect with isi mark i/c fixing arrangements etc as reqd.
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as reqd. Upto 450 mm sweep
Supplying and fixing following size GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 4 Module
Supplying and fixing following size GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 8 Module
Supplying and fixing following size GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 12 Module
Supply of 15" (380mm) sweep 1400 rpm exhaust fan heavy duty complete with shutter, blade etc as reqd.
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 200 A,36KA,FPMCCB
stage.html
html • 0.04 MB
techsummary_316064.pdf
BOQ Comparative Chart
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.47 MB
Tendernotice_2.pdf
PDF • 0.36 MB
BOQ_316064.xls
BOQ • 0.26 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .