Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.1 LAccepted-AOC C O BABA GULKARI FLAT NO C 57 SHANKARRAO PADHYE APARTMENT WARDHA ROAD SAVITRI VIHAR SOMALWADA NAGPUR 440025 MH | NAGPUR | MAHARASHTRA | 440025 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹21.1 L+₹1.9 L (10.1%)Rejected-Finance 146 CP COLONY 7 NO CHOURAHA KALPANA NAGAR MORAR GWALIOR 474006 | GWALIOR | MADHYA PRADESH | 474006 | L2 | Rejected-Finance Not L1 | |
| 3 | Rejected-Technical | - | Rejected-Technical Agency does not fulfill the eligiblity criteria |
Tender Value
₹19.7 L
EMD Value
₹39,415
Closing Date
4 Sept 2023, 11:00 amClosed
ASSISTANT MANAGER ELECTRICAL
GM ENG PROJECT AAI NTB SITE LEH AIRPORT
Internal wiring and providing Hot and cold ac units
2023_AAI_163204_1
AAI/ENGGE/LEH/NTB/2023-24/01
Open Tender
Electrical Works
Item Rate
60 days
LEH AIRPORT NTB PROJECT OFFICE
As per NIT
17 documents required · 17 mandatory
₹1,180
₹39,415
15 Sept 2023
8 Aug 2023
5 Sept 2023
8 Aug 2023
4 Sept 2023
8 Aug 2023
8 Aug 2023 - 14 Aug 2023
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bellpoint with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required
Group C
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.
Group B
Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed Steel conduit as required.
a) 2 x 2.5.sq. mm+1 x 2.5 sq.mm earth wire
b) 2 x 4.0 sq. mm+1 x 4 sq.mm earth wire
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
Telephone socket outlet
Supplying and fixing following size/modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
1 or 2 Module (75mmX75mm)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required .
a) 8 way (4 + 24), Double door
b) 12 way (4+36), Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supply of wireless calling bell complete as required.(Make: anchor or equivalent)
Supplying and drawing of CAT 6 cable conforming to ANSI/TIA/EIA-568 C.2 latest or ISO/IEC:11801 latest in suitable PVC conduit as required.
SITC of RJ45 CAT 6 Information outlet/Data Access point including backbox with base plate suitable for 2 Module GI box.
Supply and installation of 36 watt recess mounting low depth LED 2X2 ft recessed mounting lumaniries, efficacy 100 lm/W , with driver, suitable to operate on 230 volt 50Hz AC Supply complete as required as per EIC.(make: Bajaj model-BZRSQL 36 W LED GX WH or equivalent)(05 years guarantee shall be provided for complete fitting including controller by manufacturer in favor of AAI)
SITC of 2 Ton 3 Star Hot and Cold Inverter Split AC-Ez Clean Filter including providing of Suitable outdoor stand for outdoor. Cooling Power: 5200 Watts and as per the specifications enclosed. (Make: LG dual inverter model: H&C split Air conditioner or equivalent.)
Supply installation testing and commissioning of 400mm sweep, Wall mounting fan suitable for 230 volt AC Supply with all accessories etc as required. (Make M/s Bajaj ,Model sameera or equivalent)
Supply of 21Ltr Capacity of Microwave Oven as per the specifications mentioned.
Supply of 250Ltr Double door Refrigerator as per the specifications mentioned.
Manish Electricals
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .