Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.2 LAccepted-AOC | L1 | Accepted-AOC REASONABLE | |
| 2 | L2₹36.9 L+₹72,335 (2.00%)Rejected-Finance 11 753 1 HABIBULLA STREET KADAPA CUDDAPAH ANDHRA PRADESH 516001 | Y S R | ANDHRA PRADESH | 516001 | L2 | Rejected-Finance HIGH RATE | |
| 3 | L3₹39.2 L+₹3.0 L (8.30%)Rejected-Finance | L3 | Rejected-Finance HIGH RATE | |
| 4 | L4₹39.9 L+₹3.7 L (10.2%)Rejected-Finance 171 NARAYAN PETH PUNE PUNE MAHARASHTRA 411030 | PUNE | MAHARASHTRA | 411030 | L4 | Rejected-Finance HIGH RATE | |
| 5 | L5₹44.8 L+₹8.6 L (23.7%)Rejected-Finance | L5 | Rejected-Finance HIGH RATE |
Tender Value
₹43.7 L
EMD Value
₹87,360
Closing Date
14 Nov 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SHRI PRAVEEN KUMAR, IDSE
GE NDA Khadakwasla
PROVN OF DEFICIENT GEYSERS AT VARIOUS MD ACCNS AS PER AUTH AT NDA KHADAKWASLA
2022_MES_558144_1
8655/E8
Open Tender
Civil Works
Works
180 days
GE NDA Khadakwasla
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
Yes
GE NDA Khadakwasla
₹87,360
Yes
24 Nov 2022
17 Oct 2022
16 Nov 2022
17 Oct 2022
14 Nov 2022
31 Oct 2022
17 Oct 2022 - 30 Oct 2022
Amount
Supply and fixing vertical Stationary type electric water heater closed/vented type , inner body made up of MS coated with glassline coating capacity 25 Litres suitable for 230 volts , single phase AC 50 HZ Supply with BEE Star (5 Star Rating) complete with Seven years warranty on tank and two year warranty on geyser including grouting with nut bolts/fastners of suitable size complete all as specified and directed. Make: Racold Model Omnis Lux/Havells Model Monza Digi/Bajaj Model Montage Note: Fastners of suitable size for mounting geyser is to be provided separately for each geyser and the cost of same is deemed to be included in the quoted rate.
Supply and fixing GI mesh flexi connection pipes 15mm dia suitable for hot & cold water not less than 450 mm long with brass metallic flexi nuts on both ends of pipe.
Supply and fix stop valves 15 mm bore cast copper alloy high pressure with crutch of butterfly handle screwed down, screwed for iron pipe, fancy type, chromium plated all as specified and directed.
Ditto all as per item No 3 above but fancy type chromium plated.
Supply & fix Brass CP mixer for mixing hot & cold water screwed down for iron pipe 18 mm dia all as specified and directed.
Supply and fix GI tubes medium grade galvanized, with all fittings and fixed complete to wall and ceilings or laid in floors of size 15 mm dia all as specified and as directed.
M&L for sub main wiring with PVC insulated FRLS cable. LT 1100 volts grade with multistranded copper conductor and drawn into and including surface non metallic rigid PVC casing caping with all accessories alongwith one continious earth wire and connected to common earth dolly of 2x4 sqmm (2 single run) with one continuous PVC insulated FRI copper conductor cable as earthing lead of size 4 sqmm etc. complete all as specified and directed.
M&L for sub main wiring with PVC insulated FRLS cable. LT 1100 volts grade with multistranded copper conductor and drawn into and including surface non metallic rigid PVC casing caping with all accessories alongwith one continious earth wire and connected to common earth dolly of 2x2.5 sqmm (2 single run) with one continuous PVC insulated FRI copper conductor cable as earthing lead of size 2.5 sqmm etc. complete all as specified and directed.
S &F Sheet metal enclosure factory made (double door) 8 way, SPN suitable for MCBs 240 volts with 200 Amps, rated bus bar, neutral & earthing link bar, flush/surface mounting complete including
Supply and fix MCB SPN 40 Amps, 240 volts, 50 HZ, AC Supply, 10 KA `C' series.
Supply and fix MCB SP 20 Amps, 240 volts, 50 HZ, AC Supply, 10 KA `C' series.
S&F Modular AC Box for 20 A SP MCB, with Unbreakable Heavy Duty Plastic Enclosure & ISI marked Plug Top complete all as specified and directed. Make: Roma Cat part no 98491 or equivalent in Vinay/Havells
Disconnecting and taking down existing MCB DB SPN 6 way from OR accn complete with its accessories by removing from existing circuits and refixing same circuits in new DB all as specified and directed. Note: Old 6Way DB deposied in MES Store yard
Disconnecting & taking down existing sub main wiring with 2.5 sqmm copper cables between bldg main MCB DB and indl house DB at OR qtrs and depositing into MES store yard.
Dismantalling floor hearth and wall tiling incl cement mortar bedding but not backing complete all as specified.
M&L ceramic tiles as in vertical surfaces of size 350 x 450 x 7mm thick set and jointed in neat cement slurry and pointed in coloured cement to match designed incl 10 mm thick backing plaster in CM (1:4) as specified and directed.
M&L for cutting chases, pinning in making good to facing where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades shelves, lintlesetc and cutting chases for concealed water tubing and making good cutting not exc 10 cm girth as in stone walls all as directed
M&L for preparation newly plastered surfase of wall and applying two coats of OBD including 3mm thick wall care putty complete all as specified
Disconnecting of LT/HT power cables, Earthing strips etc of 100 KVA Transformer and loading, unloading of same Transformer from E Sub Stn to MES store yard (distance approx 1 KM) by taking proper safety precautions for working team complete all as directed. Note: - If any damage occured to the transformer during this course of action, the damaged parts of the Tranby sformer shall be replaced by the contractor without any extra cost to the Dept.
Labour for shifting, loading, unloading and transporting of 200 KVA, 11000/433 volts. 50 Hz, AC outdoor type distribution Transformer from MES store yard to E Sub Stn of NDA (distance approx 1 KM) and installed the same Transformer at Transformer plinth including termination of its both HT/LT side power cables, Earhing strips etc by taking proper safety precautions for working team complete all as directed. Note: - If any damage occured to the transformer during this course of action, the damaged parts of the transformer shall be replaced by the contractor without any extra cost to the Dept.
Supply and fix cable jointing kit for 11 KV grade cable for outdoor termination, heat shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 50 sqmm to 95 sqmm.
Deccan Enterprises
Sneha Aircool
KESARI AND SONS
CHAITANYA WINDWELL
TIMES HYDRO-ELECTRIC COMPANY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .