| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹94.5 LAccepted-AOC H NO 18 7 599 32 A VIVEKANANDA NAGAR CHATRINAKA HYDERABAD 500 053 | HYDERABAD | HYDERABAD | TELANGANA | 500053 | L1 | Accepted-AOC L1 | |
| 2 | L2₹97.5 L+₹2.0 L (2.09%)Rejected-Finance | L2 | Rejected-Finance Not L1 | |
| 3 | L3₹1.0 Cr+₹4.9 L (5.14%)Rejected-Finance | L3 | Rejected-Finance Not L1 | |
| 4 | L4₹1.1 Cr+₹10.5 L (11.0%)Rejected-Finance | L4 | Rejected-Finance Not L1 | |
| 5 | L5₹1.2 Cr+₹22.2 L (23.3%)Rejected-Finance | L5 | Rejected-Finance Not L1 |
Tender Value
₹1.1 Cr
EMD Value
₹2.1 L
Closing Date
2 Dec 2020, 6:00 pmClosed
COMMANDER WORKS ENGINEERS No.2, SECUNDERABAD
COMMANDER WORKS ENGINEERS No.2, SECUNDERABAD
SPECIAL REPAIRS TO SEWAGE LINES CLEANING OF SEPTIC TANKS FILTER BED AND MANHOLES OF VARIOUS UNIT AT ASIF NAGAR UNDER GE GOLCONDA
2020_MES_389541_1
81030/E8
Open Tender
Civil Works - Others
Item Rate
180 days
Hyderabad
As per tender documents
5 documents required · 5 mandatory
₹1,000
GE GOLCONDA, HYDERABAD
₹2.1 L
Yes
30 Dec 2020
24 Oct 2020
8 Dec 2020
24 Oct 2020
2 Dec 2020
19 Nov 2020
Amount
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m deep and getting out in hard/dense soil complete all as specified and as directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m deep and getting out in soft/loose soil complete all as specified and as directed.
S&F 200 mm dia Reinforced concrete pipes, class NP2, (confirming to IS-458:2003 and ISI marked) laid and jointed with collars in trenches including demolition and breaking up of old drain pipes (salt glazed ware, AC, RCC or any other type) set in cement mortar complete all as specified and directed.
All as per SI item No 3 above but for 150 mm dia pipe
M&L 100 mm dia salt glazed stone ware drain pipes grade "A" (confirming to IS-651:2007 and ISI marked) laid in trenches and jointed as specified including demolition and breaking up of old drain pipes (salt glazed ware, AC, RCC or any other type) complete all as specified and directed. .
M&L for PCC 1:3:6 type C2 (using 40 mm graded granite stone aggregate) as in concrete bed to drain pipes for pipes of 200 mm bore complete all as specified and directed.
All as per SI item No 6 above but for 150 mm dia pipe
All as per SI item No 6 above but for 100 mm dia pipe
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed.
Removing excavated soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Demolition of brick work or stone/boulder masonry built in cement mortar or cement lime mortar complete all as directed.
M&L for brickwork with fly ash bricks in CM 1:4 straight or curved on plan exc 6 m mean radius all as specified and directed.
M&L for rendering 15 mm thick in fair faces of brick work or concrete surfaces in CM 1:4 finished even and smooth with out using extra cement all as specified and directed.
S&F in repair 110 mm bore PVC vent cowl complete all as specified and as directed.
S&F in repair 75 mm bore PVC vent cowl complete all as specified and as directed.
S&F in repair 110 mm bore PVC (SWR) bend any radius complete all as specified and as directed.
S&F in repair 75 mm bore PVC (SWR) bend any radius complete all as specified and as directed.
S&F in repair 110 mm bore PVC (SWR) pipe single socketed in any length with rubber ring joints, laid in floors, trenches or similar nature complete all as specified and as directed.
All as per SI item No. 18 above, but fixed to walls.
S&F salt-glazed stoneware gully traps, 150x150 mm square or round mouthed, type 'P' or 'S' in cement concrete complete all as specified and directed.
Demolition of cement concrete (un-reinforced) in ground floors and pavings not exceeding 15 cm thickness (below or above ground level), complete all as specified and directed.
M&L for PCC 1:4:8 , type D2 using 40mm graded stone aggregate as in foundations etc., complete all as specified and as directed.
M&L for PCC 1:2:4, type B1 (using 20 mm graded stone aggregate), as in benching to manholes/drain surfaces, complete all as specified and as directed.
M&L for PCC 1:2:4 type B1 using 20 mm graded stone aggregate as in copings, surface channels and drains, manholes benching/haunching etc. including necessary form work etc complete all as specified and as directed.
Demolition of cement concrete (reinforced) in ground floors and pavings not exceeding 15 cm thickness (below or above ground level), complete all as specified and directed. (Reinforcement cut as required to facilitate demolition)
M&L for MS TMT bars 6 to 10 mm dia cut to length bend to shape required including cranking, bending, sprillay for hooping for columns, hooking ends and binding with and including MS wire (annealled) not less than 0.90 mm dia complete all as specified and as directed.
M&L for precast cement concrete 1:2:4, type B1 (using 20 mm graded stone aggregate), as in man hole cover slabs etc including necessary form work and set in CM 1:4, complete all as specified and as directed. (Reinforcement will be measured and paid seperately)
M&L for PCC 1:3:6 type C2, (40 mm graded aggregate) 100 mm thick as pavings, plinth protection, hard standing finished even and smooth without using extra cement including necessary form work etc complete all as specified and directed.
M&L for PCC 1:3:6 type C2, (40 mm graded aggregate) 75 mm thick as pavings, plinth protection, hard standing finished even and smooth without using extra cement including necessary form work etc complete all as specified and directed.
Dismantling of stone slabs and tiles of any description or thickness in floors, aprons etc. laid, bedded and pointed in any mortar etc complete all as specified and directed.
M&L for screed bed or bedding layers of cement mortar 1:6, 15 mm thick for laying floor finishes all as specified and directed.
M&L for 250x250x25 mm thick PVC moulded chequered coloured glossy tiles (confirming to IS: 13801-2013 and shall contain ISI mark) with grey cement and pigments, set and jointed in neat cement slurry in floors and pointed with coloured cement to match the shade complete all as specified and as directed.
Cleaning of septic tanks completely by empting the liquid/semi solid foul contents by mechanically or manually, including cleaning of inlets and outlets pipes and disposal of soil complete all as specified and directed. Note: The measured quantity at site shall be reduced by 20% for bulkage.
Labour only for cleaning of filter media material from filter bed of any size and depth including bailing out water, removing the filter media out of septic tanks, scarying, washing and screening to sizes as directed and loose filling back in the filter bed including old and new materials complete all as specified and directed.
Supply only broken stone aggregate for loose filling of gauge 40 to 80 mm graded.
Supply only broken stone aggregate for loose filling of gauge 20 mm graded.
Supply only broken stone aggregate for loose filling of gauge 12.50 mm graded.
Amutha Constructions
SANJEEV CONSTRUCTIONS
Sri Lakshmi Enterprises
Sri Associates
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .