| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.0 CrAccepted-AOC | ₹2.0 Cr | L1 | Accepted-AOC Being lowest and reasonable |
| 2 | L2₹2.5 Cr+₹46.4 L (23.2%)Rejected-Finance 13 29 304 IIIRD FLOOR EAST PATEL NAGAR OPP HOTEL SIDDARATHA NEW DELHI 110008 | WEST | DELHI | 110008 | ₹2.5 Cr+₹46.4 L (23.2%) | L2 | Rejected-Finance Not being lowest |
| 3 | L3₹2.5 Cr+₹48.2 L (24.1%)Rejected-Finance OFFICE NO 304 305 3RD FLOOR PLOT NO 1 USHA CHAMBERS L S C NEW RAJDHANI ENCLAVE DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | ₹2.5 Cr+₹48.2 L (24.1%) | L3 | Rejected-Finance Not being lowest |
| 4 | L4₹3.3 Cr+₹1.3 Cr (66.9%)Rejected-Finance 15 HOSHIYAR SINGH PARK KIRBY PLACE DELHI CANTT 110010 | NEW DELHI | DELHI | 110010 | ₹3.3 Cr+₹1.3 Cr (66.9%) | L4 | Rejected-Finance Not being lowest |
| 5 | Rejected-Technical | - | - | Rejected-Technical Not Approved not fulfills the eligibility the criteria |
Tender Value
Refer Docs
EMD Value
₹2.5 L
Closing Date
11 Nov 2021, 6:00 pmClosed
CHIEF ENGINEER DELHI ZONE
HQ CHIEF ENGINEER DELHI ZONE
PROVN OF SINGLE LIVING ACCN FOR DSC PL AT ARMY HOSPITAL R AND R DELHI CANTT
2021_MES_424703_2
CEDZ-45 OF 2020-2021
Open Tender
Civil Works
Lump-sum
365 days
HQ CHIEF ENGINEER DELHI ZONE
MES contractor enlisted in MES under class b cat a i having deposited Standing Security of Rs 4.00 lakh with department. Contractors not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class and category
9 documents required · 9 mandatory
₹1,000
GE (P) WEST
₹2.5 L
Yes
8 Dec 2021
10 Jun 2021
13 Nov 2021
10 Jun 2021
11 Nov 2021
14 Jun 2021
Amount
INTERNAL ELECTRIC SUPPLY S&F MCB SP 6 AMPS 'B' curve 10 KA complete all as specified and directed.
S&F MCB SP 10 AMPS 'B' curve 10 KA complete all as specified and directed.
S&F MCB SPN 32 AMPS 'B' curve 10 KA complete all as specified and directed.
S&F MCB SPN 40 AMPS 'B' curve 10 KA complete all as specified and directed.
S&F of VTPN distribution board 4 way with provision of MCCB 4 pole, 63 Amp, 25 KA as incomer and MCB SP/TP as outing having IP-20 protection complete all as specified and directed.
S&F on wall/ceiling of surface type 20 W LED Tube light with lamp and driver circuit complete with standard fitting/accessories (as applicable) the luminarie connecting up with 3 core , 1.5 sq mm pvc insulated but unsheathed , FRLS, multistranded copper conductor, cable IS-694 marked form ceiling rose to fitting complete all as specified
All as per item No 6 above but 10 W LED Tube lilght
S&F LED lamp 1x9 watt, 230v retrofit type complete all as specified and directed.
S&F exhaust fans of 300 mm sweep, heavy duty suitable for SP 230/250V, 50 Hz AC supply complete with louvre shutters including fixing/grouting of frame in wall and cutting opening complete and including 3 core 1.5 sq mm, PVC insulated but unsheathed FRLS cable with multistranded copper conductors from ceiling rose to fan completing all as specified and directed
All as per item No 9 above but exhaust fans of 450 mm sweep
S&F ceiling fans (1400 mm sweep) including fixing of fan regulators and down rods and connecting up with 3 core 1.5 sq mm PVC insulated but unsheathed, FRLS cable with multistranded copper conductors IS 694 marked from ceiling rose to fan complete all as specified and directed
All as item No 11 above but 1200 mm sweep
S&F modular stepped type electronic fan regulator 120 W flush type, one module complete all as specified and directed
S&F street light LED fittings of 36 watt suitable for mounting on pole/wall including MS clamps nut bolt/washers and GI pipe 40 mm dia medium grade of appropriate length complete all as specified and directed.
AREA DRAINAGE
S&F steel fiber reinforcement concrete (SFRC) cover of medium duty 70-75 m thick with perforated holes 50 mm dia and set in CM 1:6 complete all as specified and directed.
EXTERNAL WATER SUPPLY
M&L for extension of existing CI/MS header of 200 mm dia bore in position for insertion of one no 'Tee'/ CI special of required size and bore, connecting piece/flanged of suitable bore and connection complete for making ringmen
M&L for construction of brick/stone masonary vavle pit/chamber of size 600x600x600 all as shown in drawing CEDZ/TD 16/95 including necessary excavation and earth work, PCC plaster in CM 1:6 on inside and outside (above ground) MS angle iron 40 x 40 6 mm thick frame work with PCC cover & hold fasts, complete all as specified and directed.
EXTERNAL ELECTRIC SUPPLY
Supply, Installing & testing and commissioning factory made and tested (incl CPRI type test certified) LT feeder pillar box out door type, platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated copper bus bar 250 Amps rating installed on porcelain insulators. The panel shall be dust and vermin proof. IP 55 class protection and made of SS-316 Stainless steel sheet complete with grinding and polishing on welding spots to avoid rusting at later stage and 40 x 0 x 6 mm thick angle iron frame work, front opening type with aprons for cable entry with double door shutter and locking arrangement (including provn of 65mm Godrej Freedom) lock with 2 keys, internal wiring with PVC insulated solid copper conductor FRLS cable IS 694 marked of adequate size but not less than 4 Sqmm. The scope of work includes the following :- (Main Feeder)
(a) INCOMING
(i) MCCB 4 Pole 415 volts grade 100 Amps rating and 25 KA rupturing capacity -01 No
(ii) Voltmeter 0-500 volts, Square 96 mm,digital type -01 No
(iii) Ammeter , square 96 mm, digital type of range 0-200 Amps with rotary switch -01 No
(iv) CTs ratio 160/5 class ISI marked set of three
(v) Indicating lamp-01 set of three
(b) OUTGOING
(i) Astronomical timer with contactor 32A TPN-1No
(ii) MCCB 3 Pole, 415 volts grade 63 Amps rating and 10 KA rupturing capacity -02 Nos
(iii) MCCB 3 Pole, 415 volts grade 15 Amps rating and 10 KA rupturing capacity -02 Nos
Supply and fix LED street light fittng, suitable for 60 Watts versatile pressure die cast aluminium IP65 roadway luminaire with high power LEDs as light source and electronic divert incl suitable size GI pipe med grade not less than 1 mtr lenght and clamp, nut & bolts of suitable size for fixing of light on pole and connecting up PVC flexible cable 3 core 1.5sqmm from pole box to LED lightcomplete all as specified and as directed
S&F street light pole box of size 200x160x98mm , made of high quality thermostting plastic polystyrene, dust and jet water proof, chemical/acid corrosion resitant impact and shook proof IP-65 with internally imbedded gasket (PUR) including 1 No SP MCB 6 Amps alongwith door arrangement and pre-moulded knok out all the sides including back of the base. The box must be fitted with 10 sqmm stud type terminal 04 Nos including Elmex stud type TB 04 Nos complete all as specified and as directed
HOT WATER SUPPLY
Supply, install, testing and commissioning of water heater storage type Electric ,capacity 25 Ltr BEE 5 star rated complete including PVC connection for inlet and outlet, grouting of nut,bolts/anchor fastner for installation etc all as directed.
Supply and installation of solar water heating sytem flat plate collector type with heat exchanger of 500 ltr per day capacity with electical heating backup and service tank of 750 ltr capacity with stage and ladder fabricated with angle iron 50x50x5mm complete all as directed.
SUMMER APPLIANCES
Supply and install refrigerator electric driven (single phase) of capacity 200 ltrs. Make :- Godrej, Wherlpool, LG
Supply& install storage type Water cooler, electric driven single phase having approx storage capacity 80 ltr and nominal cooling capacity 40 ltrs per hour
Supply and install Voltage stablizer for automatic operation , single phase naturally air cooled indoor type & designed for input variation between 170V to 250 V with output voltage stablized at 230 V with accuracy ± 2.5% and capacity 0.5 KVA(for refrigerators 200 litres)
AIR COOLING SYSTEM
Supply and install Voltage stablizer for automatic operation , single phase naturally air cooled indoor type & designed for input variation between 170V to 250 V with output voltage stablized at 230 V with accuracy ± 2.5% and capacity 2 KVA(for water coolers )
Supply, installation testing and commissioning of a Ambiatory tystem 3 phase (2 stage evaporator cooling unit) front throw 10000 CFM , with mech door guard cable entry and with inlet/outlet complete with anti vibration pad, PCC foundation all as per manufacturer specification comprising the following as specifed and directed :-
(a) AHU Box construction
(i) Double skin AHU Box (ii) Extruded aluminium profile structure with nylon connectors (iii) Double Skin panle of 0.6mm pre coated GI outer skin 0.6mm GI plain inner skin (iv) CFC free PUF in situ injection to density of 40+/-2Kg/Cum (v) Base frame of GI 14 SWG (2mm) with die cast aluminium connector (vi) Blower door provided with mechanical guard for additional safety
(i) Double skin AHU Box (ii) Extruded aluminium profile structure with nylon connectors (iii) Double Skin panle of 0.6mm pre coated GI outer skin 0.6mm GI plain inner skin (iv) CFC free PUF in situ injection to density of 40+/-2Kg/Cum (v) Base frame of GI 14 SWG (2mm) with die cast aluminium connector (vi) Blower door provided with mechanical guard for additional safety
(b) Blower - Type of blower - backward curve DIDW dynamically balanced
(i) Make/Model : Kruger BDB 630 CM or equivalent (ii) Air flow machine outlet in CFM/CMH : 1000/16900 (iii) fan outlet velocity MPS : 10.33 (iv) Blower motor BKW : 5.3 (Toal stiatic Pr.Mm Wg) (v) Blower motor KW : 7.5 (Toal stiatic Pr.Mm Wg) (vi) Fan RPM :1141 (Make : ABB/CG/Havells)
(c) Blower motor specification -EFF2, TEFC, 4 P class 'F' insultion duty S1 contineous, IP 55 protection and should meet IS-12165 specification/Standards.
(d) Type of drive : 'V' Belt drive 2 SPB
(e) Sensible heat exchanger -Make HMX or equivalent (i) Material for heat exchanger - Engineering polymer cartridge with thermally fused Non woven Make HMX or equivalent.
(f) Adiabatic heat exchanger- Thickness of 150mm in case of 5mm flute. 300mm in case of 7mm flute Material-Treated and impregnated special cellulose material with saturation upto 95% Make :- Munters/Exo cool
(g) Filters:- (i) Make /Type /Size :- HMX or equivalent, Panel filter eff.90% down to 20 microns /610x610x50 (ii) Nos of filters /face velocity in MPS -8/2.2 (iii) Media filter used -HCPE sandwitched
(h) Make of pump -CG/Kirloskar or any other approved make.
(j) Head in mtrs-6 capcity 0.18 KW (02 Nos) single phase (Total 0.36 KW)
(k) UV treatment unit-250 LPH single phase 8 W
(l) Dimension -WxDxH (mm) -2150x2450x1950 Weight -1100 Kgs
(m) cable for wiring between machines and control panels of both machines
(n) PVC piping of suitable size for inlet water connetions of machines
(o) PCC foundation as per mfr specification
Supply, installation, testing and commissioning of electical starter cum control panel with micro controllers for ambiator complete all as specified and directed
Supply, fabrication, installation, testing and commissioning of rectangle sheet metal ducts through wall, floor/open complete all as ditected and shown in drgs for the following :- (a) Size 1.2mtr to 1.5 mtr 20 SWG TDF
(b) Size 1.0mtr to 1.2 mtr 22 SWG
(c) Size less than 1.0 mtr 24 SWG
(d) 9mm thick nitrile rubber duct insulation with 26 gauge aluminium foil for exposed duct and in corridor.
(e) Fire damper with fusible link
(f) 18G volume control dampers (made out of 1.25 mm thick galvanized steel, grame and blades of 1.2 mm galvanized steel sheet)
(g) Double deflection power coated extruded, supply Air aluminium grills with opposed blades dampers
(h) MS flange for duct support
(j)Canvas connection between machines
Note :- Any other associated civil work and other connected materials for insullation of Ambiator unit and connected works shall deemed to be included in the quoted rates.
S&F rotational moulded PVC water storage tank of capacity 5000 ltr (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and ditected.
M&L for compound grider for staging of water tank and cooling units etc including cutting, drilling, welding fitting riveting, nut bolts etc complete all as specified and directed.
Description of Work / Item(s)
Amount
Total amount of Sch 'A' Section I (Building work) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section I)
Total amount of Sch 'A' Section II (Internal Water Supply) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section II)
Total amount of Sch 'A' Section III (Internal Electric Supply) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section III)
Total amount of Sch 'A' Section IV (Road, Path, and Culvert) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section IV)
Total amount of Sch 'A' Section V (Sewage Disposal) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section V)
Total amount of Sch 'A' Section VI (Area Drainage) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section VI)
Total amount of Sch 'A' Section VII (External Water Supply) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section VII)
Total amount of Sch 'A' Section VIII (External Electric Supply) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section VIII)
Total amount of Sch 'A' Section IX (Hot water Supply ) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section IX)
Total amount of Sch 'A' Section X (Rain Water Harvesting) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section X)
Total amount of Sch 'A' Section XI (Excavation and site clearance) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section XI)
Total amount of Sch 'A' Section XII (Retaining Wall) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section XII)
Global Enterprises
G and G Infratech Private Limited
Shivom Projects Private limited
G and G Infratech Private Limited
Leo Network power systems
Shivom Projects Private limited
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .