Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.4 CrAccepted-AOC 1027 SECTOR 21B CHANDIGARH 160022 | CHANDIGARH | CHANDIGARH | CHANDIGARH | 160022 | ₹5.4 Cr | L1 | Accepted-AOC BEING LOWEST BIDDER L1 |
| 2 | L2₹5.4 Cr+₹2.3 L (0.42%)Rejected-AOC | ₹5.4 Cr+₹2.3 L (0.42%) | L2 | Rejected-AOC RATE QUOTED HIGHER SIDE |
| 3 | L3₹5.5 Cr+₹15.9 L (2.95%)Rejected-AOC 00 00 NAPASAR ROAD NENO KA BASS BIKANER RAJASTHAN BIKANER RAJASTHAN 334022 UDYAM RJ 08 0001676 | BIKANER | RAJASTHAN | 334022 | ₹5.5 Cr+₹15.9 L (2.95%) | L3 | Rejected-AOC RATE QUOTED HIGHER SIDE |
| 4 | L4₹6.2 Cr+₹86.6 L (16.1%)Rejected-AOC | ₹6.2 Cr+₹86.6 L (16.1%) | L4 | Rejected-AOC RATE QUOTED HIGHER SIDE |
| 5 | L5₹6.3 Cr+₹96.1 L (17.8%)Rejected-AOC STREET NO 11 SECTOR NO 04 TILAK NAGAR SAGAR ROAD BIKANER RAJASTHAN 334001 | BIKANER | RAJASTHAN | 334001 | ₹6.3 Cr+₹96.1 L (17.8%) | L5 | Rejected-AOC RATE QUOTED HIGHER SIDE |
Tender Value
₹5 Cr
EMD Value
₹5.8 L
Closing Date
26 Jul 2022, 6:00 pmClosed
CE CHANDIGARH ZONE
HQ CE CHANDIGARH ZONE,N AREA OLD AIRPORT ROAD CHANDIGARH PIN-160003
CA NO CECHZ/CHM/T-04/2022-23 PROVN OF PRE ENGINEERED BUILDING HANGAR AT CHANDIMANDIR MIL STATION
2022_MES_522784_1
CE CHZ/CHM/T-04/2022-23
Open Tender
Civil Works
Lump-sum
365 days
CHANDIMANDIR
CLASS A CATEGORY a(i)
9 documents required · 9 mandatory
₹2,000
GE(U) CHANDIMANDIR
₹5.8 L
Yes
10 Sept 2022
11 May 2022
28 Jul 2022
11 May 2022
26 Jul 2022
20 Jul 2022
11 May 2022 - 23 May 2022
Amount
Schedule 'A'Section-I (Building Works)
Design, supply and erect pre-engineered building steel structure for Hangar of size 35mx25mx10m (clear side height) and Annexe both sides as shown in drawing with Alu-zinc colour profiled steel roofing sheets 0.55mm thick (TCT) (minimum) and yield strength of 550 Mpa in wall cladding and roofing including RCC foundation, anchor bolts, base plates and all structural steel items, rain water eaves gutters and down take pipes complete all as specified. Annexe both sides shall be designed and constructed with framed structure,RCC roofing(minimum 150 mm thick RCC flat slab) and one brick thick wall including provision of finishes,roof treatment,ATT floorings,sanitary fittings,aluminium doors and windows neccessory plumbing,750 mm wide plinth protection with saucer drain all around Annexe. NOTE: Aluminium doors, windows and windows to annexe shall be provided as per openings given in the drawings.Design/pattern are to be got approved by GE.(Note:Bird proofing net,electricity operated sliding door with steel frame, turbo air ventilators and flooring of hangar & ramp shall be paid separately).
S&F polyolefin bird proof netting for Hangar of size 35m x 25 m ,all weather proof co-polymer Method of knotting : Machine knotting using CNC machine with DSLS technology for anti slip knotting. Heat setting : Stream set for greater dimensional stability knot firmness. Diameter of the twine 1mm. Mesh size 25mm X 25mm (+ or - 2mm). Type of mesh :square mesh. TBS (Twine breaking strength): 22 KGF minimum. MBS (Mesh breaking strength) : 15 KGF. KBS (Knot breaking strength) 28 KGF. Colour : UV Black. Including framed work with iron angle, flat and weld mesh including painting for bird profing etc.
S&F Stainless steel turbo ventilator type Air ventilator of 4.2 kg - 12.5 kg weight with Glossy finished all as specified.
S & F one set of B 1 parting type power operated on steel sliding doors complete with top and bottom tracks to suit a clear opening of width and height (size 25m X 7.9m) all as per specification including safety beam/rail on either side of sliding gate.
Static water tank for fire fighting of capacity 50,000 Ltrs (Drwg No : STD-1394(STR) sh 1/1)
RCC Septic tank convetional type designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation,RCC M-30 Design Mix in walls,Base Slab,Baffle walls and Roof Slab including beams etc with vent shaft,manhole opening with cover, connection etc, complete with effective depth of 1.5 meter and overall depth of 3 meter for 25 users.
Sokage wells of internal dia 1.80m including excavation, in any type of soil, foundation in PCC 1 : 3 : 6, walls of honey combed masonry with top ring of M-25 concrete including intercepting chamber and screen chamber made of brick masonry in CM, RCC cover slab in M-25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size.
Schedule 'A'Section-II (Site Clearance And Devolpment & Earthwork)
Lump sum price worked out by the Contractor for "Site Clearance And Devolpment & Earthwork" as listed in Sch 'A' Sec II
Schedule 'A'Section-III (INTERNAL ELECTRIFICATION WORKS)
Lump sum price worked out by the Contractor for "Internal Electrification Works" as listed in Sch 'A' Sec III
Schedule 'A'Section-IV (INTERNAL WATER SUPPLY WORKS)
Lump sum price worked out by the Contractor for "Internal water supply works" as listed in Sch 'A' Sec IV
Schedule 'A'Section-V (SEWAGE DISPOSAL WORKS)
Lump sum price worked out by the Contractor for "Sewage Disposal Works" as listed in Sch 'A' Sec V
Schedule 'A'Section-VI (RETAINING WALL WORKS )
Lump sum price worked out by the Contractor for "RETAINING WALL WORKS " as listed in Sch 'A' Sec VI
Schedule 'A'Section-VII (CHAIN LINK FENCING WORKS )
Lump sum price worked out by the Contractor for "CHAIN LINK FENCING WORKS " as listed in Sch 'A' Sec VII
Schedule 'A'Section-VIII ( EXTERNAL WATER SUPPLY WORKS)
Lump sum price worked out by the Contractor for " EXTERNAL WATER SUPPLY WORKS" as listed in Sch 'A' Sec VIII
Schedule 'A'Section-IX( LIGHTENING PROTECTION WORKS)
Lump sum price worked out by the Contractor for "LIGHTENING PROTECTION WORKS" as listed in Sch 'A' SecI IX
Schedule 'A'Section-X (EXT ELECTRIC SUPPLY WORKS)
Lump sum price worked out by the Contractor for "EXT ELECTRIC SUPPLY WORKS" as listed in Sch 'A' Sec X
Schedule 'A'Section-XI ( DEMOLITION / DISMANTLING WORKS)
Lump sum price worked out by the Contractor for "Demolition/dismantlng works" as listed in Sch 'A' Sec XI
Schedule 'A'Section-XII(Misc Items of Works) Note : This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col. 5 siginifies this fact only.
INTERNAL ELECTRIC SUPPLY WORKS
Point wiring using approved colour coding as per IS, with stranded copper conductor 1.5 Sq. mm (nominal area), single core, flame retardant low smoke (FRLSH), PVC insulated and unsheathed cable 1100 volts grade, ISI 694 marked TEC and FIA approved in and including heavy duty PVC concealed conduit and its fittings, ISI marked, PVC junction boxes, mild steel sunken boxes (Terminal boxes) with earth dolly, duly painted internally & externally with two coats of anti-corrosive paint over a coat of red oxide primer, covered with 3mm thick hylem sheet including flame retardant low smoke (FRLSH) PVC insulated unsheathed stranded copper conductor 1.5 Sq. mm (nominal area) single core cable as earth continuity conductor to common earth and connected to earth dolly complete all as specified, for the following: -
(a) One light point controlled by one switch or one (Ceiling/ Wall/ Exhaust) fan point controlled by one switch and regulator and one bell point controlled by one bell push
(b) One 3 pin 5 Amps socket outlet on independent board
(c ) One 3 pin 5 Amps socket outlet on same board
One socket outlet point, 16 Amp, independent, with 2.5 sqmm (nominal area) cable for phase & neutral and 2.5 sqmm (nominal area) cable as earth continuity conductor.
One socket outlet point, 16 Amp, independent, with 4 sqmm (nominal area) cable for phase & neutral and 4.0 sqmm (nominal area) cable as earth continuity conductor.
Point wiring for flame proof light fitting using approved colour coding as per IS, with stranded copper conductor 1.5 Sq. mm (nominal area), single core, flame retardant low smoke (FRLSH), PVC insulated and unsheathed cable 1100 volts grade, ISI 694 marked TEC and FIA approved in and including heavy duty steel conduit and its fittings, ISI marked, mild steel sunken boxes (Terminal boxes) with earth dolly, duly painted internally & externally with two coats of anti-corrosive paint over a coat of red oxide primer, covered with 3mm thick hylem sheet including flame retardant low smoke (FRLSH) PVC insulated unsheathed stranded copper conductor 1.5 Sq. mm (nominal area) single core cable as earth continuity conductor to common earth and connected to earth dolly complete all as specified.
Point wiring for flame proof light fitting using approved colour coding as per IS, with stranded copper conductor 2.5 Sq. mm (nominal area), single core, flame retardant low smoke (FRLSH), PVC insulated and unsheathed cable 1100 volts grade, ISI 694 marked TEC and FIA approved in and including heavy duty steel conduit and its fittings, ISI marked, mild steel sunken boxes (Terminal boxes) with earth dolly, duly painted internally & externally with two coats of anti-corrosive paint over a coat of red oxide primer, covered with 3mm thick hylem sheet including flame retardant low smoke (FRLSH) PVC insulated unsheathed stranded copper conductor 2.5 Sq. mm (nominal area) single core cable as earth continuity conductor to common earth and connected to earth dolly complete all as specified.
Point wiring for flame proof light fitting using approved colour coding as per IS, with stranded copper conductor 4 Sq. mm (nominal area), single core, flame retardant low smoke (FRLSH), PVC insulated and unsheathed cable 1100 volts grade, ISI 694 marked TEC and FIA approved in and including heavy duty steel conduit and its fittings, ISI marked, mild steel sunken boxes (Terminal boxes) with earth dolly, duly painted internally & externally with two coats of anti-corrosive paint over a coat of red oxide primer, covered with 3mm thick hylem sheet including flame retardant low smoke (FRLSH) PVC insulated unsheathed stranded copper conductor 4 Sq. mm (nominal area) single core cable as earth continuity conductor to common earth and connected to earth dolly complete all as specified.
Sub main wiring using approved colour coding as per IS with five single core, PVC insulated, unsheathed FRLSH multistranded copper conductor cables of size 10.00 sqmm (nominal area) 1100 volts grade, drawn through & including heavy duty PVC concealed conduit of suitable bore and connected to main board complete all as specified and directed. Note: (i) Five runs each of one RM of 10.00 sqmm cable together with conduit shall be considered as 1 running meter for payment purpose.
Sub main wiring using approved colour coding as per IS with three (two for main & one for earth) single core, PVC insulated, unsheathed FRLSH multistranded copper conductor cables of size 6.00 sqmm (nominal area) 1100 volts grade, drawn through & including heavy duty PVC concealed conduit of suitable bore and connected to main board complete all as specified and as directed. Note: (i) Three runs each of one RM of 6.00 sqmm cable together with conduit shall be considered as 1 running meter for payment purpose.
Sub main wiring using approved colour coding as per IS with three (two for main & one for earth) single core, PVC insulated, unsheathed FRLSH multistrand copper conductor cables of size 4 Sqmm (nominal area) 1100 volts grade, drawn through & including heavy duty PVC concealed conduit of suitable bore and connected to main board complete all as specified and as directed. Note: Three runs each of one RM of 4.0 Sqmm cable together with conduit shall be considered as 1 running meter for payment purpose.
Sheet metal Triple pole and earth enclosure with a three pin and earth plug and socket complete with one Triple pole MCB 20 Amp ( For AC ) complete all as specified and as directed
Sheet metal enclosure MCB DB, Triple pole and neutral 8 way 415 Volts,IP-43 protection, double door type grouting in wall in CM, flush mounted complete with 200 Amp rated bus bar complete all as specified and as directed.
Sheet metal enclosure MCB DB,single pole and 12 way 240 Volts.,IP-43 protection, double door type grouting in wall in CM, flush mounted complete with 200 Amp rated bus bar complete all as specified and as directed.
Sheet metal enclosure MCB DB, single pole and 8 way 240 Volts.,IP-43 protection, double door type grouting in wall in CM, flush mounted complete with 200 Amp rated bus bar complete all as specified and as directed.
LED light fitting 1x45 Watt flame proof,weather proof well glass fitting with IP-66 Protection Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and directed.
Supply and fixing LED Flood light fitting 1x120 Watt flame proof,Wheather proof well glass fitting with IP 65 Degree of protection Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size. complete all as specified and directed.
MCB SPN, 'C' series. 10 KA, 240 Volts 40 Amps capacity,complete all as specified and directed.
MCB SPN, 'C' series. 10 KA, 240 Volts 32 Amps capacity ,complete all as specified and directed.
MCB SP, 'C' series. 10 KA, 240 Volts, 6-32 Amps capacity ,complete all as specified and directed.
MCB TPN, 'C' series. 10 KA, 415 Volts, 16-32 Amp (20 Amps) capacity , complete all as specified and directed.
Supply and fixing LED light fitting 1x15 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass, with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size. ,complete all as specified and as directed.
MCCB 4 Pole of capacity 40Amp , 16 KA , 415V , IP-43, IK-09 ,complete all as specified and as directed
MCCB 4 Pole of capacity 63Amp , 16 KA , 415V , IP-43, IK-09, complete all as specified and directed.
Ceiling fan AC single phase 240 Volt 50 Hz of size 1200 mm sweep, with Squirrel cage induction motor complete in white colour having service value more than or equal to 4 with canopy and hanging rod with all accessories incl nuts,bolts,clamps etc, complete all as specified and directed
Supply and fixing Exhaust fan flame proof heavy duty 457mm sweep, 1440 rpm, 240 volts, with louver shutter , minimum power consumtion ,rigid frame with rubber mounting for silent operation , epoxy powder coating , including with core flexible cable of sutaible size from exhaust fan to ceiling rose complete all as specified and directed alongwith PVC twin flexible wire upto point including making suitable opeining in existing wall and accessories complete all as specified and directed.
Fan regulator 2 Module stepped type (electronic ) made of polycarbonate/remote control suitable for 1200/1400mm sweep AC ceiling fan complete all as specified and directed.
Supply and fix flame proof air circular fans 230 volts single phase oscillating 457mm sweep suitable for wall mounting complete all as specified and directed.
Supply and fixing LED lights fitting 1x 18W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. all as specified and directed.
Supply and fixing Flame proof 8 way distribution board for mounting MCBs/RCBOs/ELCB etc.as per IS specification and CMRI approved of factory made fabcricated out of cast aluminium alloy LM-06 gray appoxy powder coated finish,fitted with DIN Channel neutral link and 200 Amps rated busbar complete all as specified.
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V ACdecorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
Supply and fix Modular blank plate one module. complete all as specified and directed.
Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, hermostate, NRV, connection piece etc. complete all as specified and directed.
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32X6 mm galvanised iron stripcomplete all as specified and directed.
Earthing with 600x600x6mm galvanised steel earth plate electrode buried vertically in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of the plate at a depth of not less than 1.5m below ground level, connected to and including G.I. Strip of size 32x6 mm by means of bolts,nuts and check nuts and washers of galvanised steel to the extent of 7.5 metres as earthing lead and connecting to the eqpt/machinery etc. incl charcoal dust and common salt packed all around the earth plate in alternate layer in the earth pit all as per electrical plate No. 3 of SSR Part I-2009 including chamber made up of PCC 1:2:4 type B1 with M.S. angle iron frame, C.I. Cover, 20mm dia light grade G.I. Pipe from top edge of the earth plate upto M.S. funnel with wire mesh provided inside the concrete earth pit for watering arrangement incl excavation and earth work in any type of soil and testing complete all as specified and directed. Note :- GI Strip more than 7.5 mtr will be measured and paid separately (for int elec/ext elect and lightning protection)
DISPERSAL/TAXI AREA
Providing, Laying, compaction of granular sub-base by providing close graded Material conforming to specifications i.e Grading V, conforming to MORT&H Specifications for Road and Bridge Works (Fifth Revision), mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller of capacity 8 to 12 tonne to achieve the desired density, 200 mm thick compacted thickness, complete all as specified and directed by Engr-in-Charge.
Providing, Laying. compaction of Wet Mix Macadam conforming to MORT&H Specifications for Road and Bridge Works (Fifth Revision) , 150 mm thick (compacted thickness,75 mm thick in two separate layers) with mechanically crushed graded stone aggregates and granular material ,grading of aggregates as per MORT&H Specifications for Road and Bridge Works (Fifth Revision) ,including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paverfinisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 12 tonne capacity to achieve the desired density , required gradient and camber etc., complete all as specified and directed by Engineer-in-Charge. NOTES: 1. The WMM shall be laid in two layers i.e each layer of 75 mm thick (compacted thickness). 2. For payment purpose,both layers shall be considered as one unit.
M& L for providing 125 mm thick (compacted thickness) DLC (Dry Lean concrete), grade M-20 (Design Mix) using graded stone aggregate including spreading, rolling and consolidating to required gradient and camber using mechanical paver complete all as specified and directed.
M & L for supply and laying of one layer of polythene film (black colour) 400 micron thickness as per ASTM D2103/IS 2508 laid over and including 10mm thick sand layer(compacted thickness) with side and end overlapping not less than 300 mm all as approved by GE. note:- (i) Laps shall be deemed to be included in the quoted rate and will not be measured separately. (ii) Sand layer shall also be deemed included in the quoted rate.
Material and labour providing 250 mm thick pavement quality concrete (PQC) of flexural stength 45 kilogram per sq.cm using min 400 kg of cement per cubic metre, ( with maximum size of coarse aggregate upto 40mm) as per mix design, including non-circular synthetic fibre @ 0.25 kg/wt of OPC 43 grade cement polyester triangular fibre 6/12 mm long with circum diameter 30-35 micron, designed for melting point of 240-260 degree celsius and having specific gravity 1.34 to 1.4 as secondery reinforcement in concrete and necessary form work for laying in bays complete all as specified and as shown on drawings all as specified and directed. Notes:- (i) construction joints, dummy joints (contraction joints) and expansion joints shall be measured and paid separately under respective items. (ii) Deduction shall be made in computing concrete quantity for expansion joints. (iii) The PQC shall be laid using slip form paver cum vibrator of requisite capacity (iv) Necessary finishing of concrete surface by brooming while the concrete is green all as specified and directed v) Numbering/Date of casting of PQC slabs shall be done by engraving brass letters of approved size and thickness. (vi) No price adjustment shall be made for increase in quantity of cement content during execution work as per approved design.
Providing and laying expansion joint 25mm thick full depth of concrete using expanded polythylene form expansion joint filler pad in sheet form of brand 'Supreme capcell HD 100" or equivalent as approved by the GE and 30mm dia non cross linked Expanded polyethylene armour rod as per manufactures specifications. Density of expansion pad shall be 100 Kg/cum ± 10% and density of 30mm dia armour rod shall be 24 to 26 Kg/cum and filled with 10mm deep polysulphide (pour grade) RDL 941 EH, including painting of sides with polyethyelene primer applied in two coats with brushes on the sides of joint at an interval of 30 minutes, armour rods of approved quality fixed with suitable arrangements complete as per directions of Engineer-in-charge. Polythylene shall be confirm to BS 5212-1990 and primer shall be graded RDL-942 of Cholsey or equivalent as approved by the GE.
Material and labour for forming construction joint 8mm wide upto 25mm depth of concrete to form joint using diamond cutter and filled with slab filled with polyurathene joints sealant compound using mechanical means to a depth of 10mm (depth min above the back up rod) with min performance gurantee of 10 years and min movement accomanadances factor (MAF) + 30 % conforming to the requirment of BS 5212 AND EN-141875-2003 for hydrolysis/water resistance test inculding two coats primer and providing 12mm dia, approved quality closed cell polythene back up rod, applying masking tape on edge of joint to prevent accidnental slipage of seleant on top surfaces and to give a neat finish to the seleant and removing the masking tape after seleant is applied complete all as specifed and directed
Material and labour for forming contraction joint (dummy joint) upto 1/3rd to 1/4th depth of concrete slab (PQC) x 8 mm wide (using diamond cutter) an filled with polyurathene joints sealant compound using mechanical means to a depth of 10mm (depth min above the back up rod) with min performance gurantee of 10 years and min movement accomanadances factor (MAF) + 30 % conforming to the requirment of BS 5212 AND EN-141875-2003 for hydrolysis/water resistance test inculding two coats primer and providing 10mm dia, approved quality closed cell polythene back up rod, applying masking tape on edge of joint to prevent accidnental slipage of seleant on top surfaces and to give a neat finish to the selant and removing the masking tape after seleant is applied complete all as spcifed and directed
M&L Painting lines , dashes, arrows, letters etc. on pavement , roads and the like exceeding 10 cm width with aqua based road marking paints in two coats over a coat of primer including preparation of surfaces etc. all as specifed and directed.
M&L for soil stabilisation by mixing with cement upto 2% of cement by weight of dry soil ot improve the subgrade modulus (K Value) to 4 Kg/Cm2/cm and compacted to 98% of MPD(As achieved by feild test). Mix to be done with mechanical means, spread and compacted with power vibrating roller to achieve 'K' value of 4 Kg/Cm2/cm and CBR value 98% of Modified Proctor Density complete all as specified and directed.
AIR CONDITIONING
Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in copper coiling condensor unit built air ioniser and Plasma filter for better indoor air quality with minimum 4 star rating and EER 3.2.of capacity 2.00 TR
Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2.of capacity 1.50 TR.
Supply and fix voltage stablizer for automatic operation,single phase naturally air cooled indoor type & desined for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of +-2.5% and capacity 5 KVA.
REFRIGERATION WORKS
Supply, installation and commissioning refrigerator, electric driven (single phase), capacity upto to 195 Litres, BEE frost free five star rating complete all as specified and directed .
Water purifier,advanced RO purifier with digital display of purity,9 ltr storge tank with UV including zero water wastage complete all as specified and directed .
Supply, instalation, testing and commissiong of Water cooler partially stainless steel electric driven single phase having approx storage and nominal cooling cap 60/120 ltr complete all as specified and directed.
Supply and installation of Desert cooler electric driven (single phase) with outer body made of PGI (Plain Galvanised Iron) sheet not less than 1.20 mm thickness for fixed part,thickness of PGI (Plain Galvanised Iron) sheet for shutter not less than 0.80 mm thickness,front grill made of PGI (Plain Galvanised Iron) sheet with minimum weight 2.80 kgs,overall outer size not less than 66 cm X 66 cm X 99 cm (Height) ,copper wounded fan motor having nominal air flow capacity of 4000 cum per hour and submersible pump for required flow of water complete all as specified and directed.
Voltage stabilizer for automatic operation single phase naturally air cooled indoor type and designed for input variation between 170 V to 250V copper wound with output voltage stabilized at 230 V with accuracy of + 2.5 % and of capacity 0.5 KVA.complete all as specified and directed.
Voltage stabilizer for automatic operation single phase naturally air cooled indoor type and designed for input variation between 170 V to 250V copper wound with output voltage stabilized at 230 V with accuracy of + 2.5 % and of capacity 3 KVA complete all as specified and directed
EXTERNAL WATER SUPPLY
Supplying, laying, jointing & testing ductile iron pipe of nominal dia 100mm, centrifugally cast, ISI marked (IS : 8329 amended upto date) class K-7 socket and spigot (S&S) and with and including push on type EPDM ISI marked (IS : 5382) rubber gasket jointing including zinc coating with finishing layer of bitumen coating on outside of pipe and ordinary portland cement lining from factory from inside of pipe complete all as specified and directed by Engineer-in-Charge. NOTE: (i) DI fittings and earth work shall be measured and paid separately. (ii) The measurement of pipes shall be net as fixed between the fittings incuding short lengths, without any allowance for cutting & waste and for the portions entering the sockets of the pipes & fittings. (iii) No separate payment for cutting of pipes and no allowance for cuts necessiated during the work shall be made. Cost of all the above aspects shall be deemed to include in the quoted rates of above items. (iv) During Excavation any damsge to electric,water,BSNL,any communications cables repair cost may included in quated rate.
Construction of brick masonary valve pits of size 900 mm x 900 mm x 900 mm (internal dimension of chamber), depth of chamber to be recokoned from the top of PCC in foundation to top of MS cover as shown in drg with and including MS sheet cover fabricated from 3 mm thick MS sheet and frame of angle iron 40 mm x 40 mm x 5 mm with fixing arrangement hinges and locking arrangement and painting two coats of synthetic enamel paint over a coat of red oxide primer after preparation of surfaces on MS cover and frame including necessary excavation and earth work in any type of soil, returning, filling in approved soil, disposal of surplus soil to a distance not exceeding 50 metre, 150 mm thick PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in foundation, brick work using bricks as mentioned in PS clause 5.1 in cement mortar 1:6, 15 mm plastering in cement mortar 1:4 both internally and externally 30cm below GL, 100 mm thick PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in flooring complete all as specified and directed by Engineer-in-Charge.
Construction of brick masonary valve pits of size 600 mm x 600 mm x 600 mm (internal dimension of chamber), depth of chamber to be recokoned from the top of PCC in foundation to top of MS cover as shown in drg with and including MS sheet cover fabricated from 3 mm thick MS sheet and frame of angle iron 40 mm x 40 mm x 5 mm with fixing arrangement hinges and locking arrangement and painting two coats of synthetic enamel paint over a coat of red oxide primer after preparation of surfaces on MS cover and frame including necessary excavation and earth work in any type of soil, returning, filling in approved soil, disposal of surplus soil to a distance not exceeding 50 metre, 150 mm thick PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in foundation, brick work using bricks as mentioned in PS clause 5.1 in cement mortar 1:6, 15 mm plastering in cement mortar 1:4 both internally and externally 30cm below GL, 100 mm thick PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in flooring complete all as specified and directed by Engineer-in-Charge.
Ductile iron fittings such as bends (any type, radius and angle) Tapers any type (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch, 'Y' junction, double branch, cross (all sockets or socket and spigot) collars, tail pieces with one end flanged (integrally cast) and one end socket/spigot caps and plugs suitable upto 200 mm bore ductile iron pressure pipes of K-9 classification and push on flexible rubber gasket joints complete all as specified.
Earthing complete with and including galvanised steel earth plate electrode 600 mm x 600 mm x 6 mm surrounded by a mixture of charcoal and salt in alternate layers burried directly in ground vertically in a pit of depth not less than 2.25 m deep below ground level with top edge of earth plate at a depth of not less than 1.5 m below ground level, connected with and including galvanised iron or steel earth wire, 4mm dia (No. 8 SWG) by means bolts, nuts, check nuts and washers made out of galvanised iron, 15 mm bore (light grade) GI pipe for protection of earthing lead, 20 mm bore (light grade) GI pipe for watering with funnel, wire mesh and including necessary excavation and earth work, PCC 1:2:4 type B-1 pit and 50 mm thick RCC M-25(Design mix) reinforced with XPM (weight not less than 3 kg/sq m) pit cover, C.I frame, charcoal and comman salt filling in alternate layers, complete all as shown and specified in electrical plate No. 3 of SSR Part-I (2009) complete all as specified and directed by Engineer-in-Charge. Note : (i)The unit rate includes for protecton pipe 15mm and GI earth strip 4mm from top of earth plate upto 7.50 metre above ground level. (ii) If desirable earthing result not found re done earthing without any extra charge until get required earth resistance. (iii) The result sheet of earthing may submit to sub division level by contractor.
Supply, installation, testing and commissioning 3 phase and neutral, 415 volts out door type, factory made free standing, floor mounting, dust and vermin proof cubical type, LT Panel fabricated from 3.15 mm thick CRCA sheet with anti corrosive coating and finally epoxy polyester powder coating of flint Grey shade (RAL-7032), fully compartmentalized design with 4 Nos of copper bus bar with colour code of 200 Amps capacity each and supply and fixing the following :-Incoming (a) MCCB 100 Amps , 4 pole, ultimate breaking capacity 25 KA with fixed magnetic release for short circuit and adjustable thermal release for overload (Range 70% to 100% of nominal current) and under voltage release conforming to IEC-60947-2 and IS-13947-3 complete all as specified – 01 Nos (b) Change over switch 100 Amp 415 Volts 4 pole complete-1 Nos Outgoing (a) MCCB 63 Amps , 4 pole, ultimate breaking capacity 25 KA with fixed magnetic release for short circuit and adjustable thermal release for overload (Range 70% to 100% of nominal current) and under voltage release conforming to IEC-60947-2 and IS-13947-3 complete all as specified – 01 Nos (b) MCCB 63 Amps 4 Pole,25 KA, 415 V-01 Nos. (c) MCCB 40 Amps 4 Pole,16 KA, 415 V-03 Nos. (d) MCCB 16 Amps 4 Pole,10 KA, 415 V - 01 Nos.(For street Light) (e) Suitable size of Timer analog type for street light complete.
LED street light luminaire with unique peanut optics to ensure uniform distribution .higher spacing between poles and maintenance free system lumen output 4500 Lm with colour temp 5700 k LED suitable optical lens as secondary optics covered light source with glass IP-66 inbuilt electronic drivers 230 Volts 45 Watt cap including suitable size of bracket made out of 40 mm GI light grade tubing 1.20 mtr long bent to shape with 02 Nos of clamps, nuts & bolts reqd complete all as specified and directed.
S&F M S Box with Aluminum bus bar 32 Amp 1100 V complete of size 90mmX90mmX60mm of 3.15 mm thick sheet complete all specified.
Supply, jointing, testing and commissioning cable end termination jointing kit 415 Volts (earthed) grade cable for outdoor termination cold shrinkable type straight through joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured alluminium conductor cbale of size 185 Sq mm complete all as specified and directed by Engineer-in-Charge.
Cable route indicator shown "LT UG cables" painted in blue colour and root of cable with aero made of CI in suitable eleiptical shape and fixed in MS rod 12mm dia 70 cm long ( all word embosed) and embaded in PCC block of size 30 x 30 x 60cm in ground complete all as specified and directed.
DG SET WORKS
Supply, erecting, testing and commissioning complete static silent (Sound Proof enclosure) Diesel Engine Driven Generating Set capable of delivering 62.5 KVA , water cooled, 415 Volts (AC three phase, 4 Wire system of supply) 50 Hz at power factor 0.8 minimum with AMF panel. The DG Set shall consists of diesel engine coupled to a matching alternator, through flexible coupling and mounted on common base frame and complete with control panel standardized by manufacturer, fuel tank with mounting arrangements and inlet , outlet return inlet oil arrangement, exhaust pipe complete and suitable for conditions prevalent at Chandigarh (Capacity of Engine, alternators shall be worked out taking all derating factors into consideration) anti-vibration pads, including all features to comply with latest CPCB guidelines and Comprising of followings:- (i) ENGINE (Prime Mover) : Diesel Engine 1500 RPM , direct injection ,4 cylinders ,four stroke, confirming to ISO3385TCIGM-C2/BS 5514, water cooled, naturally turbo charged, capable of giving adequate BHP to drive Alternator capable of delivering 62.5 KVA at outdoor atmospheric conditions at Chandigarh (NTP), (Taking all derating factor into consideration) complete with fly wheel all standard fittings/fixtures as per OEM recommendations and including suitable panel with tachometer, lub oil temperature, pressure gauge and frequency meters and also including self starter system including batteries with electronic governor and Engine protection system (Shut down, High water temperature, low lub oil, oil pressure, over speed etc) fuel tank and first fill of lub oil and other consumables etc complete all as specified and directed by Engineer-in-Charge.(Cont..)
(ii) Alternator : Brushless AC alternator, 3 Phase, 415 Volt, 4 wire, rated for output of 62.5 KVA Minimum power factor 0.8, 1500 RPM, IP 23 Protection class enclosure, insulation Class "H", salient pole, revolving field, single bearing automatic voltage regulator coupled through flexible coupling with and to match the above engine. (iii) BASE PLATE : Made out of structural steel as per manufacturers recommended design/specification. (iv) AMF Panel: AMF control panel suitable for 62.5 KVA DG set consisting of overlod relay, under current relay, phase failure detector, battery charger, delay timer consisting of quick auto or manual mode with bypass system.AMF panel shall be floor mounted, front operated cubical paneloutdoor type fabricated out of 2mm thick CRCA sheet including meter connection and copper busbar suitable for use at 415V, 3 Phase,4 wire, 50HZ system comprising of the MCCB 100Amp, 4 pole, 25KA breaking capacity, overload, short circuit and earth fault protection alongwith LCD display. Digital multifunction metering alongwith CTs and RYB indicating lam, Copper Bus bar of rating 250Amp. (v) The contactor shall supply two year maint spares for the above Gen set: (a) Fuel fitler element -12 Nos. (b) Lub oil filter - 12 Nos. (c) Element air cleaner outer-06 Nos. (d) Element air cleaner Inner-06 Nos. (e) Filter lub oil by pass - 02 Nos. (f) V Belt -02 Nos. (vi) Fuel Tank: Inbuilt fuel tank of suitable capacity as per manufactures recommendation capble to store 12 hrs running of DG sets with all pipes, oil level indicating gauge, drain and air vent blug etc. (vii) Warrenty for Battery shall be two year from installatoin fo Gen Set.
Note: For the purpose of arriving at lumpsum amount, the amount of credit sch for buildings and other services i.e Sch 'A' section XIII (i.e Rs 9993.60 shall be deducted from the total amount arrived.
Total of Schedule 'A' Section-XII Rs.
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .