| Sl No | Description | Qty | Unit | BHATNAGAR ASSOCIATES L4 | omsai thermax engineers L5 | Indu Electricals L8 | Srinivasa Consructions L3 | SUN LIGHT HOUSE L9 | S.S.ENGINEERING CORPORATION L6 | CHITRA ENGINEERING CORPORATION L1 | EXELLENT POWER CORPORATION L2 | SRI SAI ENTERPRISES L7 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Draining out the old existing unserviceable compressor oil from the AC plant compressor of any capacity and type, supply and Charging of suitable/ same as existing make Compressor Oil complete all as directed by Engineer-in-Charge. | 45 | Ltr | 1,800 ₹81,000 | 2,000 ₹90,000 | 1,000 ₹45,000 | 320 ₹14,400 Lowest | 900 ₹40,500 | 1,025 ₹46,125 | 900 ₹40,500 | 3,267 ₹1,47,015 | 1,005 ₹45,225 |
| 2.00 | Supply and re-filling of Refrigerant gas R-134A / R-22 / 407 complete all as directed.
Make : Refron/Mefron/Freon | 549 | KG | 1,440 ₹7,90,560 | 1,530 ₹8,39,970 | 2,300 ₹12,62,700 | 450 ₹2,47,050 Lowest | 2,444 ₹13,41,756 | 1,300 ₹7,13,700 | 650 ₹3,56,850 | 535 ₹2,93,715 | 2,310 ₹12,68,190 |
| 3.00 | S&F new hermetically sealed scroll compressors suitable for package type air conditioner of 5.5 TR capacity, after taking down the old unserviceable compressor, with mounting assembly such as rubber springs etc., after disconnecting all electric connections, including alteration of refrigerant piping suction and discharge, pressure testing the complete system with nitrogen after carrying out repairs, flushing out the complete system, vaccumising and gas charging with R-22 refrigerant gas to obtain designed cooling closing of suction and discharge valves complete all as specified and directed.
Notes:1. The unit rate quoted shall be deemed to include for Copper Brazing rods, Nitrogen Gas, LPG Gas Tins, copper filter and capillary, pin type valves as required at site
2. Refrigerant Gas will be measured & paid separately under relevant items of this BOQ. | 1 | Each Job | 54,000 ₹54,000 | 54,000 ₹54,000 | 65,000 ₹65,000 | 5,00,000 ₹5,00,000 | 66,000 ₹66,000 | 75,000 ₹75,000 | 55,000 ₹55,000 | 38,223 ₹38,223 Lowest | 65,250 ₹65,250 |
| 4.00 | All as per item No. 3 above but for 11 TR capacity package type air conditioner. | 1 | Each Job | 90,000 ₹90,000 | 91,000 ₹91,000 | 75,000 ₹75,000 | 10,00,000 ₹10,00,000 | 77,000 ₹77,000 | 85,000 ₹85,000 | 65,000 ₹65,000 | 56,409 ₹56,409 Lowest | 75,250 ₹75,250 |
| 5.00 | All as per item No. 3 above but for 22 TR capacity package type air conditioner. | 1 | Each Job | 1,53,000 ₹1,53,000 | 1,53,000 ₹1,53,000 | 95,000 ₹95,000 | 12,00,000 ₹12,00,000 | 96,000 ₹96,000 | 1,25,000 ₹1,25,000 | 1,10,000 ₹1,10,000 | 87,543 ₹87,543 Lowest | 95,255 ₹95,255 |
| 6.00 | Supply and Fix V belts of any size all as specified and directed. | 65 | Each | 900 ₹58,500 | 1,000 ₹65,000 | 500 ₹32,500 | 1,000 ₹65,000 | 555 ₹36,075 | 650 ₹42,250 | 450 ₹29,250 | 363 ₹23,595 Lowest | 508 ₹33,020 |
| 7.00 | Supply and Fix water flow /water pressure cut out switch all as specified and directed. | 10 | Each | 3,330 ₹33,300 | 3,450 ₹34,500 | 2,000 ₹20,000 | 1,000 ₹10,000 Lowest | 2,222 ₹22,220 | 3,750 ₹37,500 | 2,500 ₹25,000 | 4,192 ₹41,920 | 2,150 ₹21,500 |
| 8.00 | Suppy and fix 3 pole 315 amps MCCB having current carrying capacities with adjustable thermal and magnetic settings,50 hz with 16 KA rupturing capacity at 415 volts, including provision of copper cable/extended terminals of suitable rating from MCCBs to busbar and connection LT cables with suitable size aluminium lugs including dismantling the unserviceable MCCBs from panel boards complete all as specified and a directed as per site requirement. | 3 | Each | 27,000 ₹81,000 | 27,000 ₹81,000 | 35,000 ₹1,05,000 | 27,000 ₹81,000 | 36,000 ₹1,08,000 | 34,250 ₹1,02,750 | 19,500 ₹58,500 | 11,898 ₹35,694 Lowest | 35,250 ₹1,05,750 |
| 9.00 | All as per item No. 8 above but for capacity 200 Amps | 4 | Each | 16,200 ₹64,800 | 15,500 ₹62,000 | 25,000 ₹1,00,000 | 2,000 ₹8,000 Lowest | 24,000 ₹96,000 | 25,200 ₹1,00,800 | 14,450 ₹57,800 | 6,719 ₹26,876 | 25,255 ₹1,01,020 |
| 10.00 | All as per item No. 8 above but for capacity 160 Amps | 4 | Each | 14,400 ₹57,600 | 15,000 ₹60,000 | 20,000 ₹80,000 | 16,000 ₹64,000 | 19,000 ₹76,000 | 19,800 ₹79,200 | 12,500 ₹50,000 | 5,918 ₹23,672 Lowest | 20,255 ₹81,020 |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
13 Oct 2025, 6:00 pmClosed
GE(I) R AND D RCI, HYDERABAD
GE(I) RND RCI, MILITARY ENGINEER SERVICES, VIGNYANAKANCHA, RCI, HYDERABAD
REPAIR MAINTENANCE OF SCREW TYPE AND SEALED TYPE COMPRESSORS CONDENSERS AND CHILLER CONNECTED PIPE AND PUMPS AT RCI UNDER GE I RND RCI HYDERABAD
2025_MES_730931_1
8329
Open Tender
Electrical and Maintenance Works
Item Rate
335 days
GE(I) R AND D RCI
MES enlisted Class D category c i Un enlisted Meeting enlistment criteria of D class in MES and having no recovery pending. For further details ref NIT
8 documents required · 8 mandatory
₹500
Yes
GE(I) R AND D RCI, HYDERABAD
₹96,000
Yes
17 Oct 2025
15 Sept 2025
15 Oct 2025
15 Sept 2025
13 Oct 2025
29 Sept 2025
Amount
Draining out the old existing unserviceable compressor oil from the AC plant compressor of any capacity and type, supply and Charging of suitable/ same as existing make Compressor Oil complete all as directed by Engineer-in-Charge.
Supply and re-filling of Refrigerant gas R-134A / R-22 / 407 complete all as directed. Make : Refron/Mefron/Freon
S&F new hermetically sealed scroll compressors suitable for package type air conditioner of 5.5 TR capacity, after taking down the old unserviceable compressor, with mounting assembly such as rubber springs etc., after disconnecting all electric connections, including alteration of refrigerant piping suction and discharge, pressure testing the complete system with nitrogen after carrying out repairs, flushing out the complete system, vaccumising and gas charging with R-22 refrigerant gas to obtain designed cooling closing of suction and discharge valves complete all as specified and directed. Notes:1. The unit rate quoted shall be deemed to include for Copper Brazing rods, Nitrogen Gas, LPG Gas Tins, copper filter and capillary, pin type valves as required at site 2. Refrigerant Gas will be measured & paid separately under relevant items of this BOQ.
All as per item No. 3 above but for 11 TR capacity package type air conditioner.
All as per item No. 3 above but for 22 TR capacity package type air conditioner.
Supply and Fix V belts of any size all as specified and directed.
Supply and Fix water flow /water pressure cut out switch all as specified and directed.
Suppy and fix 3 pole 315 amps MCCB having current carrying capacities with adjustable thermal and magnetic settings,50 hz with 16 KA rupturing capacity at 415 volts, including provision of copper cable/extended terminals of suitable rating from MCCBs to busbar and connection LT cables with suitable size aluminium lugs including dismantling the unserviceable MCCBs from panel boards complete all as specified and a directed as per site requirement.
All as per item No. 8 above but for capacity 200 Amps
All as per item No. 8 above but for capacity 160 Amps
All as per item No. 8 above but for capacity 125 Amps
All as per item No. 8 above but for capacity 100 Amps
All as per item No. 8 above but for capacity 63 Amps
All as per item No. 8 above but for capacity 32 Amps
Supply and Fix LP/HP Transducer all as specified and directed.
Supply and Fix Fan motor pcb all as specified and directed.
Supply and Fix Fan motor mcb all as specified and directed.
EXPANSION TANK FOR CHILLED WATER AND S & F in replacement of PVC/HDPE expansion tank of 1000 litre capacity with pressure rating to suit the system pressure and sized adequately to compensate for water expansion due to operating temperature variations, conforming to IS: 2825- 1969 for 'non-fired pressure vessels' complete with inter-connection piping, non-return valve, safety relief valve and pressure gauge, insulated with 50 mm thick elastomeric insulation and cladded with 26 gauge aluminium complete with accessories as specified and directed by the engineer-in-charge.
Supply and Fix HRC fuse of 125 Amps capacity of any model after removing old unserviceable hrc fuse of same capacity as per site requirement
All as per item No. 19 above but for capacity 63 Amps
All as per item No. 19 above but for capacity 32 Amps
Supply and Fix pressure gauge of any rating 0 to 150/ 300 psi or eqyivalent in kgs/cm2 any model after removing old unserviceable pressure gauge of same capacity as per site requirement
Supply and Fix cable connectors of capacity 32/63 Amps of any model/type after removing old unserviceable hrc fuse of same capacity as per site requirement
Supply only as in replacement over load relay range 14 to 25 Amps, 415 Volts.
Supply only as in replacement over load relay range 9 to 15 Amps, 415 Volts.
Supply, laying and testing XLPE,Insulated,screened,pvc bedded gs strip or wire armoured electricpower cable of heavy duty,1100 volts grade with stranded aluminium concustor of size 10 sqmm 4 core all as specified and a directed by Eng in charge.
All as per item No. 26 above but of size 16 sqmm 4 core
Supply, installation, testing and balancing of factory fabricated four bolt with TDF flanges rectangular GSS ducting of thicknessm 22 gauge including neoprene rubber gaskets, supports, hangers, nut bolts, splitter dampers, vanes, canvas connections complete as per specifications etc
Supplying and fixing of duct thickness 13 mm duly laminated aluminum foil of mat finish closed cell Nitrile rubber (Class "O") insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required.
Disconnecting and isolating the compressor upto 20 to 45 TR capacity AC plant of any make electrically and mechanically from the system. After pumping down the system, opening the end cover gear system, checking of the high speed gears, low speed gears, male & female rotors, bearings, overhauling of the same, replacing of the wornout spare parts, supply only unserviceable spares like trust anchor, roller, tapers, Gasket set re-assembling, refixing back to the system, flushing of the system with dry nitrogen (N2), charging of the oil checking of the oil pressure, leak testing and gas charging complete all as directed by Engr-in-Charge. Note :- (a) Supply of crank shaft, pistons, piston rings, Piston pin, connecting rods, half bearing, suction / discharge reeds, brass washer, thrust washer, shaft seal, internal oil filter, section filter, SH 68 Oil, suction / loading springs, wall plates, gasket seal etc which are mentioned in the scope of work and deemed to the amounte quoted. (b) Compressor oil and Refrigerant gas shall be measured and paid separately. Labour charges,pressure testing/leak testing deemed to be included in the scope of the work.
All as per item No. 30 above but of compressor in 50 to 95 TR capacity AC plant.
All as per item No. 30 above but of compressor in 100 to 150 TR capacity AC plant.
Descaling of condenser any capacity by circulating descaling agent (DC-96) through condensers by forced feed method by removing the end covers of the condensers, cleaning the each tube of condenser thoroughly by brushing, re-fixing the end covers with new rubber gasket, nuts bolts, washers and testing complete all as directed.
Opening covers of AHU, descaling of the AHU coil/ Condensor coil to bring down the high pressure, cleaning of the dust particles formed on the coil system with diluted 'ASFOCLEAN' chemical or Caustic Soda by pouring on the coil with leg pump or mechanical system till the clearing of the dust on the coil as primary wash and using detergent powder or surf water as final wash, testing complete all as directed.
Engineering charges for inspection, testing, programming & commissioning, draining, vacuumising, re-filling including replacement of spares, re-commissioning, pressure testing of 20 to 50 TR capacity AC plant of any type ( including packaged type ) and make to run the smooth functioning all as specified and directed (work should be carried out through OEM) Notes:1. The unit rate quoted shall be deemed to include for Copper Brazing rods, Nitrogen Gas, LPG Gas Tins, copper filter and capillary, pin type valves as required at site 2. Refrigerant Gas and major spares will be measured & paid separately under relevant items of this BOQ.
All as per item No. 35 above but of capacity 50 to 95 TR
All as per item No. 35 above but of capacity100 to 150 TR
Leak / pressure testing of the system of water cooled chiller unit of 20 to 45 TR capacity of AC Plant with nitrogen (N2) pressure. After evacuating of existing gas from the system in to empty cylinder by separating the entire system like compressors, condensors, cooling coil and refrigerant lines and rectifying of the leakage including cutting, welding, brazing etc and reconnecting with ‘O’ rings, washers, gaskets etc and flushing out the Nitrogen and vacuumising, recharging the taken out refrigerant gas complete all as directed.
All as per item No. 38 above but of capacity 50 to 95 TR
All as per item No. 38 above but of capacity100 to 150 TR
Disconnecting the unserviceable VFD panel from the existing position, supply and fixing in replacement to VFD drive a new Star Delta starter of capacity suitable for 20 HP motor complete all as specified and directed by the Engr-in-Charge.
Taking down micro process based control panel (PCB) of chiller package 25 to 45 TR, of ANY Model,Type and Make of AC plant and replace the unserviceable PCB, supply and fix new PCB to micro process based control panel of same capacity and refixing to chiller package and programing to the entire panel for smooth functioning, testing complete all as directed. Note : The work shall be executed through OEM of make Blue Star.
All as per item No. 42 above but of capacity 50 to 100 TR
EXELLENT POWER CORPORATION (BID ID -3444246)
Srinivasa Consructions (BID ID -3449340)
BHATNAGAR ASSOCIATES (BID ID -3442972)
omsai thermax engineers (BID ID -3448821)
S.S.ENGINEERING CORPORATION (BID ID -3449783)
SRI SAI ENTERPRISES (BID ID -3449339)
Indu Electricals (BID ID -3448973)
SUN LIGHT HOUSE (BID ID -3449585)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .