Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical | Admitted-Fee/PreQual/Technical |
| 2 | Admitted-Fee/PreQual/Technical | Admitted-Fee/PreQual/Technical |
| 3 | Admitted-Fee/PreQual/Technical | Admitted-Fee/PreQual/Technical |
| 4 | Admitted-Fee/PreQual/Technical | Admitted-Fee/PreQual/Technical |
Tender Value
₹10.5 Cr
EMD Value
₹21.0 L
Closing Date
10 Aug 2026, 6:00 pmClosed
Additional Chief Engineer
ACE PHED Region Kota
Work of Water Supply Scheme for Augmentation of UWSS Chhabra under District Baran including 05 years O and M after 01 year Defect Liability period under AMRUT 2.0
2026_PHCJA_573997_1
04/2026-27
Open Tender
Civil Works - Water Works
Percentage
Chhabra District Baran
Please refer Tender documents.
2 documents required · 2 mandatory
₹10,000
Executive Engineer PHED Division Chhabra
₹21.0 L
Yes
ACE PHED Region Kota
11 Aug 2026
9 Jul 2026
11 Aug 2026
9 Jul 2026
10 Aug 2026
9 Jul 2026
17 Jul 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Providing, lowering, laying in trenches, aligning, fixing in position and jointing Ductile Iron (DI) ISI marked K-7 grade S&S pipes as per IS:8329-2000 (amended up to date), with internal cement mortar lining suitable for potable water with rubber ring (EPDM) joints as per IS: 5382-1985 including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges, including cost of labour and material, specials (Tee, bend etc.) satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge. (excluding earth work) Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. | |||||
| 1.01 | 100 mm | - | Rmt. | 1,464 | - |
| 2.01 | 150 mm | - | Rmt. | 2,082 | - |
| 3.01 | 200 mm | - | Rmt. | 2,554 | - |
| 4.01 | 250 mm | - | Rmt. | 3,307 | - |
| 5.01 | 300 mm | - | Rmt. | 4,221 | - |
| 6.01 | Providing and fixing of flanged/ plain ended MS Specials made from MS sheet strips of relevant IS specification of approved thickness by welding, lowering, laying, aligning, fixing in position at all level/ depths in trenches complete including all taxes, material, labour, inside lining, outside coating, testing and commissioning along with pipe line as per technical specifications and
direction of Engineer-in-charge. | - | - | - | - |
| 7.01 | MS pipe specials up to 600mm dia (with minimum 5mm thickness sheet) | - | kg | 126 | - |
| 8.01 | Providing Household Tap Connection as per technical specification and approved drawing as per relevant IS code (amended up to date) from uPVC/DI/AC/MS/GI pipe line up to consumer meter/premises by using PP/MS saddle piece (Complete job).This job includes digging out suitable size of pits and trench for laying service line in all kinds of soil (excluding road); depositing and refilling of pit & jhiri with watering & ramming /compacting in layers and disposal of surplus excavated soil as directed with in a lead of 100 meter ; providing & fixing of all fitting duly approved in accordance with specification for potable water including MS/PP saddle piece, gunmetal ferrule 4.0 mm , GM Full-way Valve (IS:778 Mark) or ball valve (min. weight 165 gm) and specials, below ground level 20 mm nominal dia MDPE pipe PE 80 PN 16 as per ISO 4427 / 20 mm nominal dia PPR-C (Three layered) pipe PN16 SDR 7.4 (IS:15801:2008) (ISI mark) and above ground level using 20 mm dia PPR-C pipe with standard PPR fittings/ 15 mm dia GI pipe with fittings in the premises for fixing a tap / meter box (excluding) ,including accessories with flushing, cleaning, disinfecting and testing of pipe line complete required for making of service connection complete in all respect including labour charges . The service line should be laid at least 45 cm below ground level.
Note: Road cut and restoration is not part of this item and paid separately. | - | - | - | - |
| 9.01 | For connection with 20 mm dia MDPE/PPR-C pipe length up to 05
mtr. | - | Each | 1,658 | - |
stage.html
html • 0.02 MB
tech_bid_open.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.02 MB
TD04.pdf
Tender Documents • 18.48 MB
BOQ_1021042.xls
BOQ • 0.36 MB
Corri01.pdf
PDF • 0.25 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .