| 1 | L1₹26.8 LAccepted-AOC SAS NAGAR MOHALI PUNJAB | S A S NAGAR | PUNJAB | 140103 | L1 | Accepted-AOC Award of Contract M/s Manveer Energy by the committee for the Lower Bidder than others | |
| 2 | L2₹27.9 L+₹1.2 L (4.32%)Rejected-Finance S O MAKHAN SINGH | L2 | Rejected-Finance Higher tender rates from the lowest bidder |
Tender Value
₹24.5 L
EMD Value
₹49,000
Closing Date
28 Aug 2023, 10:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer, Abohar Canal and Ground Water
Executive Engineer, Abohar Canal and Ground Water Division Water Resources, Abohar
Estimate for Construction of V.R. Bridge at RD 8400 of Muradwala Minor
2023_WR_107210_1
E-Tendering Notice No.13/Abohar Canal Ground Wat
Open Tender
Civil Works - Canal
Item Rate
Sri Muktsar Sahib
Please refer Tender documents.
6 documents required · 6 mandatory
₹2,000
Yes
₹49,000
Yes
6 Dec 2023
11 Aug 2023
28 Aug 2023
12 Aug 2023
28 Aug 2023
12 Aug 2023
Dismanteling of old bridge C.C 1:4:8
Dismanteling of old bridge Brick work
Dismanteling of old bridge RCC
PCC 1:3:6 (M-10) nominal mix with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by viberation i/c curing for 14 days as per drawing and technical specification.
Laying RCC M-30 for solid slab superstructure using batching plant, Transit mixer and concrete pump including cenetering & shuttering laid in position complete in all respects. (upto 5 m height)
Providing and fixing drainage spout complete as per drawing and Technical specification.
Providing and laying filter media with granular materials/ stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2 of MORTH specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall/return wall to the full height compacted to a firm condition complete as per drawing and Technical specification.
Providing weep holes in brick masonry/Reinforced concrete abutment, wing wall/return wall with 100 dia PVC pipe, extending through the full width of the structure with slope of 1V:20H towards drawing face complete as per Drawing and Technical Specifications.
Providing and applying two coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ 1 Litre for 2 sqm.
Cautionary sign board 600 x 600 x 600 mm triangular as per IRC 67 - 2001 with retro reflective high intensity microprismatic grade sheeting fixed over 2 mm thick aluminium sheet with 25 x 25 x 3 mm angle iron frame supported on a mild steel angle iron post 65 x 65 x 6 mm without cost of definition plate firmly fixed to ground in foundation cconcrete 1:2:4 of size 0.45 x 0.45 x 0.60 m for vertical post complete as per technical clause 801 MORT&H specifications.
Mandatory sign board 600 mm circular as per IRC 67 - 2001 with retro reflective high intensity microprismatic grade sheeting fixed over 2 mm thick aluminium sheet with 25 x 25 x 3 mm angle iron frame supported on a mild steel angle iron post 65 x 65 x 6 mm without cost of definition plate firmly fixed to ground in foundation cconcrete 1:2:4 of size 0.45 x 0.45 x 0.60 m for vertical post complete as per technical clause 801 MORT&H specifications.
Informatory sign board 600 x 600 mm square as per IRC 67- 2001 with retro reflective high intensity microprismatic grade sheeting fixed over 2 mm thick aluminium sheet with 25 x 25 x 3 mm angle iron frame supported on a mild steel angle iron post 65 x 65 x 6 mm without cost of definition plate firmly fixed to ground in foundation cconcrete 1:2:4 of size 0.45 x 0.45 x 0.60 m for vertical post complete as per technical clause 801 MORT&H specifications.
Excavation in soil using hydraulic jcb and hydraulic trolley with disposal upto 2.50 Km including cutting and loading in trolley, trimming bottom and side slopes in accordance with requirements of lines, grades and cross sections and transporting to embankment location within all lifts and lead.
Extra for laying earthwork as per specifications for compaction in 20 cm layer and dressing including cost of rolling and watering as per specifications.
Earthwork for lip cutting for irrigation of channel inclusive of all allowances leads and dressing 0 to 1.5 mtr depth.
Earthwork for lip cutting for irrigation of channel inclusive of all allowances leads and dressing 1.50 to 3.00 mtr depth.
Earthwork excavation in foundation, trenches etc. in all kinds of soil where pick jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and side of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm, layers with compaction including disposal of all surplus soil as directed within a lead of 30 metres.
Laying 1st class brick lining 75 mm thick laid in 1:3 CSM over 10 mm thick cement Plaster 1:3 over 12.5 mm thick cement plaster 1:5 over dressed sub grade (for side slopes) including supply carriage, loading and unloading of material from source to site of work complete in all respects as per PWD specification.
Laying 1st class brick on edge coping 229 mm wide and 115 mm thick in cement sand mortar 1:3 complete in all respects as per PWD specification.
Extra allowance for providing templates in curved portions of lining.
Extra allowance for scaffolding in lining for side slopes only.
Dismantling brick work, tile masonry or tile lining (in cement mortar).
PCC (M-15) nominal mix with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by viberation i/c curing for 14 days as per drawing and technical specification.
(25.4) Providing running & maintenance of pumping set 8 H.P/Generator set for dewatring arrangement complete in all respect.
CHAPTER NO. 21 BRIDGES- FOUNDATIONS & SUB-STRUCTURE (21.33) Supplying, fitting and placing HYSD bar reinforcement in sub-structure complete as per drawing and Technical Specifications.
(21.1) Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with excavated surplus soil. In Ordinary soil (B) Mechanical Means (a) Depth upto 3 m
(21.32) Plain/Reinforced cement concrete in sub-structure complete as per drawing and Technical Specifications (F) RCC Grade M25 ((a)) Height upto 5m ((ii)) With Batching Plant, Transit Mixer and Concrete Pump
(21.25) Cement Concrete for Reinforced Concrete in Pile Cap complete as per Drawing and Technical Specification (C) RCC Grade M30 ((ii)) Using Batching Plant, Transit Mixer and Concrete Pump
CHAPTER NO. 22 BRIDGES-SUPER STRUCTURE & PROTECTION WORK (22.2) Supplying, fitting and placing HYSD bar reinforcement in super-structure complete as per drawing and technical specifications.
CHAPTER NO. 22 BRIDGES-SUPER STRUCTURE & PROTECTION WORK (22.12) Crash Barriers (A) Provision of an Reinforced cement concrete crash barrier at the edges of the Bridge,road, approaches to bridge structures and medians, constructed with M-40 grade concrete , with HYSD reinforcement conforming to IRC:21 and dowel bars 25 mm dia, 450 mm long at expansion joints filled with pre-moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclosure to MOST circular No. RW/NH - 33022/1/94-DO III dated 24 June 1994 as per dimensions in the approved drawing and at locations directed by the Engineer, all as specified-with concrete mixture.
Any other item
GURPREET SINGH CONTRACTOR
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .